| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.7 LAccepted-AOC 121004 | L1 | Accepted-AOC Being lowest bidder and reasonable | |
| 2 | L2₹44.0 L+₹1.2 L (2.87%)Rejected-Finance 165 UTTAR KASTODANGA ROAD KOLKATA 700 061 | KOLKATA | KOLKATA | WEST BENGAL | 700061 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹44.9 L+₹2.1 L (4.89%)Rejected-Finance 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹46.6 L+₹3.8 L (8.90%)Rejected-Finance P 45 KHIRODE VIDYA BINOD AVENUE KOLKATA 700003 | KOLKATA | WEST BENGAL | 700003 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹46.7 L+₹3.9 L (9.20%)Rejected-Finance 17 1A BALLYGUNGE CIRCULAR ROAD KOLKATA 700 019 | KOLKATA | WEST BENGAL | 700019 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹38.8 L
EMD Value
₹77,600
Closing Date
3 Mar 2023, 6:00 pmClosed
GE(FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
SPL REPAIR TO MAIN WATER SUPPLY CI/DI/GI DISTRIBUTION PIPE LINES FROM DIFFERENT PUMP HOUSES (QUEENS BK PH, SO-II, GANNERY PH, DALHOUSIE PH, COMD MESS PH, AOI PH) TO MD OTM ACCN AND CONVERSION OF OLD RUSTED GI PIPE LINES INTO PPR LINES AT VARIOUS PH I
2023_MES_580130_1
8985/FW/E8
Open Tender
Civil Works - Water Works
Item Rate
180 days
GE(FW) Kolkata
Ref tender documents
7 documents required · 7 mandatory
₹500
GE(FW) Kolkata
₹77,600
16 Mar 2023
10 Feb 2023
4 Mar 2023
10 Feb 2023
3 Mar 2023
24 Feb 2023
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation or for shafts, wells cesspits, manholes etc., not exceeding 10 sqm on plan and getting out in soft/loose soils, complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing excavated material not exceeding 50 metre and deposited where directed at a level not exceeding 1.5 metre above the starting point in soil complete all as specified and directed.
Taking up/down CI/DI water mains and connections/ fittings of any type from trenches /walls/floors/(or any other location) for replacement /reuse in old/new location/ diversion by burning out /removing of lead joints/ tyton joints/rubber gasket joint complete all as specified and directed for the following size of pipes :- (Note: Necessary earthwork, if any shall be measured and paid separately under relevant item.
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supply, laying, connecting and testing of ductile iron pipe, spigot and socket ends, class K-7 in standard working length conforming to IS-8329 laid in trenches, complete all as specified and directed for the following size :-
Burning out lead joints in position of cast iron pipes, fittings and re-making joints using old retrieved lead complete all as specified and directed for following size of pipes :-
80mm bore
100mm bore
150mm bore
200mm bore
Note for Item No 6.01 to 6.04: In case, inadequate lead is retrieved from burning out, for remaking joints, additional lead required shall be measured and paid separately as "Supply only".
Supply only lead confirming to IS 782 complete all as specified and as directed.
S&F CI bends upto 200 mm bore (any type, radius and angle) taper any type (straight, bend, increasing, decreasing or double socket etc) tee pieces, 'Y' junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete all as specified and as directed.
S&F DI bends upto 200 mm bore (any type, radius and angle) taper any type (straight, bend, increasing, decreasing or double socket etc) tee pieces, 'Y' junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete all as specified and as directed.
Taking up or down GI Steel Water Tubing including Connections and Fittings, Segregating Serviceable Pipes & Fittings, Stacking properly at Site(s) and keep in Safe Custody for re-use, complete all as specified and as directed for the following size of pipes :-
100mm bore
80mm bore
50mm bore
40mm bore
25mm bore
20mm bore
15mm bore
Supply, Laying and testing Steel Water Tubing, Galvanised, ‘Medium Grade’ with all Fittings, laid in trenches or any other Situation, complete as all specified and directed for the follwing size of pipes :-
100mm bore
80mm bore
50mm bore
40mm bore
25mm bore
20mm bore
15mm bore
Supply, laying and testing of 3- layer PP-R Polypropylene random copolymer) pipes SDR 11 UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed by Engr-in-Chargefor the following sizes:-.
110mm bore outer dia
90mm bore outer dia
63mm bore outer dia
50mm bore outer dia
32mm bore outer dia
25mm bore outer dia
20mm bore outer dia
Supply and fixing PPR Gate valve with brass insert and brass working parts suitable for PPR pipe, complete all as specified and directed for the following sizes:-
63mm bore outer dia
50mm bore outer dia
32mm bore outer dia
25mm bore outer dia
20mm bore outer dia
S&F Cast Iron Sluice valve of Class PN-1.6 long body type, heavy duty, ISI marked (IS 1538) flanged end with iron wheel and brass spindle including rubber gasket joints, nuts, bolts etc as in repair complete all as specified and directed for the following size of pipes :-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
S&F in repair, Cast Iron non-return valve, with bypass arrangement, ISI marked, with flanged ends including rubber gasket joints, nuts, bolts etc complete all as specified and directed for the following size of pipes :-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
300 mm bore
S&F Gun metal gate valve as per IS : 778-84 Class-1 Pressure tested 2.4 Mpa with iron wheel head, screwed both ends for iron pipes or for unions as in repairs, complete as all specified and as directed for the following size of pipes :-
50 mm bore
40 mm bore
25 mm bore
20 mm bore
S&F in repair Buller fly valve DI body with stainless steel disc & Stem , nitrile/EPDM liner, level operated, ISI marked, with necessary rubber gaskets, nuts and bolts and washers of suitable size complete all as specified and directed for the following size of pipes :-
40mm bore
50mm bore
65mm bore
80mm bore
100mm bore
150mm bore
200mm bore
S&F in repair CI butterfly valve, BS-5155 Gear operated with necessary rubber gaskets, nuts and bolts and washers of suitable size complete all as specified and directed for the following size of pipes :-
80mm bore
100mm bore
150mm bore
200mm bore
Construction of valve chamber of size 750x750x750mm internal size suitable for housing sluice valve/ gate valve etc with PCC 1:4:8 type D2 for foundation 15mm thick with an offset of 5 cm on all sides, 230mm thick brick work in CM 1:4, 15mm thick rendering in CM 1:4, 50mm thick PCC 1:2:4 type B1 coping all over brick work around, including provision of MS angle iron frame 40x40x6mm embedded in concrete with suitable hinges 5mm thick MS sheet cover and locking arrangements including two coats of synthetic enamel paint over a coat of red oxide metal primer on exposed steel surfaces, with and including demolition of existing damaged valve chamber and necessary excavation & earth work etc., all as specified and directed
M&L for cutting of road/hard standing not exc 30cm in width and not exc 60cm in depth for removal/laying of water tubing including returning filling and making good the disturbed surfaces with PCC 1:2:4 type B1 using 20mm graded aggregates, 100 mm thick, on top, finishing surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate for coping/ encasing around of ole including necessary form work finished even and smooth without using extra cement all as specified and directed by Engineer-in-Charge.
Taking out suction pipe of 200mm bore with defective CI foot valve/stainer of 200 mm dia and replace foot valve (ISI marked) including necessary nut, bolt, washers and cutting threading of GI pipe if required and lowering in the sump complete all as directed by the Engr-in-Charge.
Taking out suction pipe of 150mm bore with defective CI foot valve/stainer of 150 mm dia and replace foot valve (ISI marked) including necessary nut, bolt, washers and cutting threading of GI pipe and lowering in the sump complete all as directed by the Engr-in-Charge.
Taking out suction pipe of 100mm bore with defective CI foot valve/stainer of 100 mm dia and replace foot valve (ISI marked) including necessary nut, bolt, washers and cutting threading of GI pipe and lowering in the sump complete all as directed by the Engr-in-Charge.
S&F 100mm bore double orifice Air Release valve in CI body, ISI marked, including bolts, nuts & washers and packing material, as in repair complete all as specified and as directed.
MS AP CONSTRUTION AND CO
RAJ ENTERPRISE
UNIVERSAL TRADING CENTRE
M A ENTERPRISES
Somani Builders
DEB AND COMPANY
JAGATMATA ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .