REPAIR REPLACEMENT OF INTERNAL ELECTRIFICATION ELECTRICAL FITTING FIXTURE AT OLD NEW APS COLONY ARJAN VIHAR AND ADJOINING AREA UNDER GE CENTRAL DELHI CANTT10
2020_MES_325918_1
GE/C-59/2019-20
Open Tender
Electrical and Maintenance Works
Works
240 days
GE (Central) Delhi Cantt
As per NIT
9 documents required · 9 mandatory
₹500
GE (Central) Delhi Cantt
₹98,000
Yes
18 Mar 2020
17 Feb 2020
18 Mar 2020
17 Feb 2020
16 Mar 2020
4 Mar 2020
17 Feb 2020 - 4 Mar 2020
Amount
Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete excl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc. complete all specified and directed by Engineer-in-Charge
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through Existing PVC conduit, including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty and fabricated branded modular metal flush box / M S Steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:-
One light/fan point controlled by one way switch
One bell / buzzer point controlled by one bell push
One light point controlled by two Nos two way switches
One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 2 but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board.
All as per item No 2 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4.0 Sqmm single core stranded copper cable for one AC/geyser point on independent board. Note for item No. 1 to 4 - PVC Cable Make:- "RR Kable, Havells & polycab"
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall/ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded modular metal flush box / M S steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:- (i) PVC conduit shall be Medium grade, ISI marked.Make:- " Polycab, Kalinga Premium and AKG" (ii) PVC Cable Make:- "RR Kable, Havells & polycab"
One light/Exh fan point controlled by one way switch
One bell / buzzer point controlled by one bell push
One light point controlled by two Nos two way switches
One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 5 but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board. (i) PVC conduit shall be Medium grade, ISI marked.Make:- " Polycab, Kalinga Premium and AKG" (ii) PVC Cable Make:- "RR Kable, Havells & polycab"
All as per item No 5 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4.0 Sqmm single core stranded copper cable for one AC/geyser point on independent board. Note for item No. 5 to 7 (i) PVC conduit shall be Medium grade, ISI marked.Make:- " Polycab, Kalinga Premium and AKG" (ii) PVC Cable Make:- "RR Kable, Havells & polycab"
M&L in replacement switch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge. Make:- Legrand/Havells/ ABB
M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge. Make:- Legrand/Havells/ ABB
M&L in replacement switch modular type 6 amp SP two way, 1 module ISI marked Make:- Legrand/Havells/ ABB
M&L in replacement Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge. Make:- Legrand/Havells/ ABB
M&L in replacement switch Modular type 16 Amps 1Way, 1 module with modular plate light marking 230V AC complete all as specified and directed by Engineer in charge. Make:- Legrand/Havells/ ABB
M&L in replacement Modular socket outlet 2/3 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge. Make:- Legrand/Havells/ ABB
M&L in replacement modular stepped type electronic fan regulator 120W, 2 module all as specified and directed by Engineer in charge. Make:- Legrand/Havells/ ABB
M&L in replacement switch piano flush button type single pole one way 6 Amps all as specified. Make:- Legrand/Havells/ ABB
M&L in replacement switch piano flush button type single pole Two way 6 Amps all as specified. Make:- Legrand/Havells/ ABB
M&L in replacement bell push single pole 6 Amps all as specified, Make:- Legrand/Havells/ ABB
M&L in replacement switch piano flush button type single pole 16 Amps.Make:- Legrand/Havells/ ABB
M&L in replacement socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole . Make:- Legrand/Havells/ ABB
M&L in replacement socket outlet 6 Amp flush button type all as specified. Make:- Legrand/Havells/ ABB
M&L in replacement regulator electronic switch/socket type 5 steps suitable for 1200/1400 mm sweep 230 volts all as specified and directed. Make:- Legrand/Havells/ ABB
M&L in replacement bell electric (dingdong) 230 volt, SP all as specified and directed. Make : Havells Reo/ legrand/Schneider/Polycab .
M&L in replacement Buzzer, AC, 230 Volts, single pole, all as specified and directed. Make : Havells / Crompton Greaves/ Bajaj.
M/L in replacement insulated body, angle holder (metal ring) with back plate ISI marked complete all as directed. Make : Havells / Crompton Greaves/ Bajaj.
S&Fin replacement ceiling rose surface PVC 65x50 mm type with three terminals. Make:- Havells/Polycab/Anchor.
M&L in replacement white cover plate with frame 1 module/ 2 module complete all as specified and directed by Engineer in charge.
M&L in replacement white cover plate with frame 3 module complete all as specified and directed by Engineer in charge.
M&L in replacement white cover plate with frame 6 module complete all as specified and directed by Engineer in charge.
M&L in replacement white cover plate with frame 8 module complete all as specified and directed by Engineer in charge.
M&L in replacement sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket 240 Volts grade 10Amps complete with one single pole MCB 'C' series 10A / 20 A capacity all as specified and directed. Make:- Legrand /siemens/ABB.
Supply and fix in replacementLED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed. Make:- Philips/Wipro/Jaquar/CLAIR/CG
Supply and fix in replacement LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. (Mirror light) Make:- Philips/Wipro/Jaquar/CLAIR/CG
Supply and fix in replacementL LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed. Make:- Philips/Wipro/Jaquar/CLAIR/CG
S&F in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base. Make:- Philips/Wipro/Jaquar/CLAIR/CG
Supply and fix in replacement LED 2 X 2 ft backlite surface mounted fitting 36/40 Watts not less than 3200lm with Metallic CRCA powder coated body with high efficiency opal/PMMA diffuser with system efficacy > 80 lm/W, CRI>80, color temperature >5700k, IP 20, Power factor<0.95, THD<10%, 50000 burning hours , Ambient temperature 0 to 500 DegC, Driver should meet IEC complaint for safety, with voltage variation range of 150-270 V and surge protection of 2.5 KV including necessary fixing arrangementsfixed complete all as specified and directed. Make:- Philips/Wipro/Jaquar/CLAIR/CG
Supply and fix in replacement surface ceiling mounted, LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed. Make:- Philips/Wipro/Jaquar/CLAIR/CG
Supply and Fix in replacement 45 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete as specified and directed. Make:- Syska/Wipro/Bajaj/CG/CLAIR
Supply and Fixing in replacemen LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base. Make:- Philips/Wipro/Jaquar /CLAIR
Supply and Fixing in replacemen LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base. Make:- Philips/Wipro/Jaquar/CLAIR
Supply & fix in repair factory made epoxy powder coated Load line Distribution Board TPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including insulated 200 Amp copper bus bar, Isolated neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 32 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623. Make:- Legrand/ IndoAsian/Havells/BALENO
Supply and fix in replacement MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge. Make:- Legrand/SEIMENS/ABB./BENLO)
Supply and fix in replacement MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge. Make:- Legrand/SEIMENS/ABB.
Supply and fix in repair MCCB 250 Amps, FP 415 volts 25 KA 50 HZ with thermal magnetic setting .Make:- Legrand/SEIMENS/ABB/Benlo
Supply and fix in replacement MCCB 160 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting .Make:- Legrand/SEIMENS/ABB/Benlo
Supply and fixin replacement MCCB 125 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting .Make:- Legrand/SEIMENS/ABB. /BENLO
Supply and fix in replacement MCB DP 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete. Make:- Legrand/SEIMENS/ABB./BENLO
Supply and fix in replacement MCB DP 20 Amps 240 volts 10 KA 50 HZ 'C' curve complete. Make:- Legrand/SEIMENS/ABB. /BENLO
Supply and fix in replacement MCB DP 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete. Make:- Legrand/SEIMENS/ABB.
Supply and fix in repair MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete. Make:- Legrand/SEIMENS/ ABB.
S & F exhaust fan 300 mm in replacement sweep metal type including provision of 3 core PVC insulated sheathed 1100 volts grade flexible cable with stranded copper conductor from ceiling rose to fan, length as per requirement at site. Make : Orient /Bajaj/Havells
Supply and fixing Ventilating Fan 250 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed. Make : Orient /Bajaj/Havells
Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed. Make : RR Kable, Havells & polycab, Note: Three runs of 6 sqmm cable shall be measured as one RM.
S&F in repair Sub main wiring with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls complete all as specified and directed. Make for wiring cable :-RR KABLE/Finolex/Havells/Polycab. Note:- PVC rigid conduit ISI marked FRLS Grade Make: POLYCAB/AKG/BAJAJ
Supply and fix in repair Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed. Make : RR Kable, Havells & polycab, Note: Three runs of 10 sqmm cable shall be measured as one RM.
Cutting the existing wall/removing existing steel bar to make a hole for fixing of exhaust fan through packing of wooden ply to support the ventilating/ air circulating fan including necessary nut and bolts of suitable size incl make good of disturbed surface complete all as directed by Engr-in charge.
S&F in relacement plug top 16 Amps 3 pin 230- volts Make:- Havells /Reo/Polycab.
S&F in replacement plug top 6 Amps 3 pin 230- volts Make:- Havells /Havells Reo/Polycab.
S&F in replacement plug top, 3 pin, 10amp / 20 amp earth metal clad (ISI marked) as directed.
S&F in replacement socket 3 pin 10 amp / 20 amp earth metal clad (ISI marked) as directed.
S & F PVC Gang box surface type heavy duty suitable for single switch 5 Amps (ISI Marked) . Make- Legrand /Havells/Crabtree/Polycab.
S & F Gang box surface type heavy duty suitasble for 15 Amps switch and socket (ISI Marked) Make- Legrand or equivalent in Havells/Crabtree/Polycab.
Supply only hylum sheets 3 mm thick (ISI marked) of the following sizes :-
Sheet 4" x 4" single cutting suitable for one piano switch
Sheet 4" x 4" two cuttings suitable for two piano switches
Sheet 4" x 7" three cuttings suitable for three piano switches
Sheet 4" x 7" one cutting for 6 Amp socket and two cuttings for piano switches
Sheet 8" x 10" incl cuttings for switches and sockets 6/16Amps as directed.
Sheet 10" x 12" incl cuttings for switches and sockets 6/16Amps as directed.
M & L for in replacement only single core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge. Make: RR cable/HavellsH/Polycab
M & L in replacement for only single core PVC insulated cable 2.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge. Make: RR cable/HavellsH/Polycab
M & L in replacement for only single core PVC insulated cable 4 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.Make: RR cable/HavellsH/Polycab
M & L in replacement for only single core PVC insulated cable 10 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.Make: RR cable/HavellsH/Polycab
M&L in replacement copper cable flexible 3 core PVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge. Make: RR cable/HavellsH/Polycab.
M&L in replacement copper cable flexible 3 core PVC insulated of size 40/.0076 ll as specified and directed by Engr-in-Charge. Make: RR cable/Havells/Polycab
S & F hole fastner madeup of MS 6" long with complete nut bolt all as specified.Make:as per sample
S & F hole fastner madeup of MS 4" long with complete nut bolt all as specified.Make:as per sample
S&F in replacement GI Pipe bracket bent to shape drilled welded made out of light grade GI pipe 32/40mm dia 1.5 mtr long and fixing on the wall where as directed by the Engr-in-Charge for fixing of building security light fitting including MS clamps, nuts, bolts and washers complete all as specified by the Engr-in-Charge . Make:As per sample
Refixing Ceiling fan / exhaust fan/ fresh air/ Wall mounted fan after necessary repairs/ replacement of unserviceable/ wornout part and testing the same as per entire satisfaction of Engr-in- Charge complete all as specified and directed. Note- Spare Parts shall be measured and paid separately under relevant item of supply only.
M&L for opening up the winding of ceiling fan 1200 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete. Testing of the ceiling fan to the entire satisfaction of Engr-in-Charge.
All as per item No 101 above but 1400mm sweep complete. Testing of the ceiling fan to the entire satisfaction of Engr-in-Charge.
S&F in replacement capacitor of 2.5 MFD, Make :Orient/Epcos/Havells.
S&F in replacement capacitor 3.15 MFD Make : Orient/Epcos/Havells.
Supply gun metal bush of any size and make sutiable for ceiling fans 1200/1400 mm compete all as specified and directed.
Supply ball bearing No. 6202, Make: SKF/NBC/TATA
Supply ball bearing No. 6203, Make: SKF/NBC/TATA
Supply worn out shaft, beyond economical repair of existing ceiling fan any make, type or size as per original one ceiling/exhaust fan complete all as directed.
Supply & fixing Ceiling fan blade suitable for 1200mm sweep of any make with suitable size as per site requirement as per existing complete all as specified and directed.
Supply Ceiling fan blade suitable for 1400mm sweep of any make with suitable size as per site requirement as per existingcomplete all as specified and directed.
M & L for painting of ceiling fans , in situ with synthetic enamel paint by spraying including filling cavities with filler, one or more coat to achieve even and smooth surface after cleaning all dust etc.and endorsement of fan no.with black synthetic enamel paint complete all as directed.
Supply Fresh air fan motor of capacity 1/6 HP 230 volts, 50 Hz, AC supply alongwith 1 MFD capacitor and cap suitable for 250/200 mm size Fresh air fan as per sample complete all as spd and directed.
Supply exhaust fan motor capacity 1/4 HP 230 volts suitable for 250 mm size exhaust fan complete all as directed.
Taking down unserviceable water heater (Geyser) of size 25/35/50 Ltrs for checking of defects and repairs including disconnecting water connction by unscrewing/cutting the existing GI pipe, threading as necessary for new connection (including GI tubing in short lengths/fittings) and refixing after carrying out repairs and replacement of spares including connecting to wate supply, electric connection using suitable size multistranded copper cables and testing complete all as specified and directed. Note : Spares shall be measured and paid separately under relevent Sch 'A' items.
Supply & fixing base plate assembly (confirming to ISI ) complete for 25/35 Ltrs capacity copper tank geyser including inlet, outlet and thermostat pipe with drain plug and screws for fixing the element inclusive of clamps for holding the elements with nut, bolts & air release valve suitable for any type/make of geysers installed at site as directed.
S & F thermostat suitable for geyser of any capacity, any make including taking down old unserviceable thermostat all as specified and as directed by EIC.
S & F heating elements for geysers of size 1.5 KW (Make - THEETA/BAJAJ/USHA) with nut bolt & washer including taking down the old unserviceable heating element. Note :- The element shall be round / triangular or any type as per sample or as directed by Engr-in-charge
S & F heating elements for geysers of size 2 KW (Make - THEETA/BAJAJ/USHA) with nut bolt & washer including taking down the old unserviceable heating element. Note :- The element shall be round / triangular or any type as per sample or as directed by Engr-in-charge
M & L for non return valve 15mm dia (ISI Marked) for Geysers of 50/35/25 Ltr capacity including GI Socket,Nipple, elbow ,bend etc and connecting up complete all as directed.
M&L for safety pressure valve of size 15 mm dia, ISI marked for geysers complete all as directed by Engineer-in-charge.
S&F SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 60 cm long with brass nuts and rubber washers complete all as specified and directed. Make - Havells / Jaquar / Bajaj.
M & L neon lamp/indicator lamp for geysers complete all as directed.
M&L for soldering and brazing inner copper tank 25/50 ltrs with brass solder and refixing complete .
Supply & fixing inner steel tank for geysers of capacity 25/35 ltr as per existing of approved make complete all as directed
M&L for earthing complete with galvanized steel earth plate 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel besides welding at all joints including excavation and earth work, GI pipe light grade 15mm bore for protection of G.I. wire from earth electrode to the Main switch/Distr Board, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B-1 using 20mm graded stone aggregate chamber and MS angle iron frame 40 x 40 x 3 mm and RCC cover 40 mm thick RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, round, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified & directed.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc 4 mm dia galvanised or steel wire complete all as specified.
S&F factory made epoxy powder coated switch disconnector fuse unit TPN with sheet metal enclosure confirming to IS 60947-3, 200Amps, positive isolation suitable for DIN & Bolted HRC fuse links fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts. Make :-Havells.
S & F electronic driver with high voltage protection upto 380 Volt AC suitable for LED building security light, 30/40/45 watt including connecting complete with connected accessories at given site complete all as specified and directed by engr-in-charge. Make:as per sample
S&F in replacement BUS BAR cable juction box made out of CRCA sheet not less than 1.6 mm thick with 200Amp rated aluminium 3 phase bus bar including connecting all cable with thimble on bus rail including nut and bolt and all required accessories complete all as specified and directed by engr-in-charge . Make :-Havells/legrand/Baleno
Note :- Total amount of Sch of credit is Rs 140428.00 as per Sch of credit. Net contract sum shall be total quoted amount of bidder (-) amount of Sch of credit.
M/S Sunil Steel Works
Pall Associates
M/S ANIL KUMAR
SANJEEV ENTERPRISES
M/s Sohanil Construction
M/s M M BAHL
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .