Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹31.2 LAccepted-Finance | 1 | Accepted-Finance L1 | |
| 2 | 2₹32.4 L+₹1.2 L (3.87%)Accepted-Finance | 2 | Accepted-Finance L2 |
| Sl No | Description | Qty | Unit | M/s USR Transport L1 | S Rajan L2 |
|---|---|---|---|---|---|
| 1.00Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 min width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, withina lead of 50 m. | |||||
| 1.10 | All kinds of soil | 7.2 | Cum | 817 ₹5,882.4 Lowest | 889 ₹6,400.8 |
| 2.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | 4.6 | Cum | 267 ₹1,228.2 Lowest | 300 ₹1,380 |
| 3.00Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. | |||||
| 3.10 | 1:3:6 (1 Cement: 3 coarse sand (zone-III) derived from natural sources:6 graded stone aggregate 20 mm nominal size derived from natural sources). | 2.5 | cum | 17,537 ₹43,842.5 Lowest | 18,000 ₹45,000 |
| 3.20 | 1:4:8 (1 Cement:4 coarse sand (zone-III) derived from natural sources:8 graded stone aggregate 40 mm nominal size derived from natural sources) | 0.8 | Cum | 16,207 ₹12,965.6 Lowest | 17,000 ₹13,600 |
| 4.00Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: | |||||
| 4.10 | 1:1.5:3 (1 cement: 1.5coarse sand (zone-III) derived from natural sources:3 graded stone aggregate 20 mm nominal size derived from natural sources). | 1.9 | Cum | 23,007 ₹43,713.3 | 23,000 ₹43,700 Lowest |
| 5.00Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: | |||||
| 5.10 | 1:1.5:3 (1 cement: 1.5coarse sand(zone-III) derived from natural sources:3 graded stone aggregate 20 mm nominal size derived from natural sources). | 1.4 | Cum | 24,007 ₹33,609.8 Lowest | 24,500 ₹34,300 |
Tender Value
₹30.0 L
EMD Value
₹60,031
Closing Date
26 Sept 2025, 10:00 amClosed
Executive Engineer
Office of the Executive Engineer CD, APWD, Campbell Bay.
Major renovation of GPA Type-II quarter 17/18, 65/66 at Babulane, Campbell Bay
2025_APWD_20002_1
NIT No. 35 /EE/CD/CB/2025-26
Open Tender
Civil Works - Others
Item Rate
150 days
Executive Engineer CD, APWD, Campbell Bay
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹60,031
25 Nov 2025
19 Sept 2025
29 Sept 2025
19 Sept 2025
26 Sept 2025
19 Sept 2025
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 min width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, withina lead of 50 m.
All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level.
1:3:6 (1 Cement: 3 coarse sand (zone-III) derived from natural sources:6 graded stone aggregate 20 mm nominal size derived from natural sources).
1:4:8 (1 Cement:4 coarse sand (zone-III) derived from natural sources:8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:
1:1.5:3 (1 cement: 1.5coarse sand (zone-III) derived from natural sources:3 graded stone aggregate 20 mm nominal size derived from natural sources).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement:
1:1.5:3 (1 cement: 1.5coarse sand(zone-III) derived from natural sources:3 graded stone aggregate 20 mm nominal size derived from natural sources).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Centering and shuttering including strutting, propping etc. and removal of form for:
Foundations, footings, bases of columns, etc. for mass concrete.
Suspended floors, roofs, landings, balconies and access platform.
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Posts and Struts.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of1stclass hard wood andwell matched commercial3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
30 mm thickincluding ISI markedStainless Steelbutthinges with necessary screws.
Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of5 mm, made outofextruded5 mm rigid PVC foam sheet, mitred at corners and joined with2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer's specification and direction of Engineerin- Charge.
Providing and fixing factory made panel PVC door shutter consisting of frame made outofM.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm fortop& bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with5 mm thick heat moulded PVC ‘C’ channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out ofwhich 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail& bottom rail, paneling of5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles& rails with7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer's specification& drawing.
30 mm thick plain PVC door shutters
Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and lnline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for (i) Sites with basic wind speed > 45 m/sec as per IS 875 — Part 3 (ii) Sites with structure height more than 20m for all wind speeds. Fixed window/ventilator without mullion/ transom.
Using R1 series with frame (33mm & above) X(35mm & above). Height upto 0.90 meter)
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS: 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry@ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm ormore (thickness to be specified by the manufacturer), of1stquality conforming toIS: 15622, ofapproved make, in coloursWhite, Ivory, Grey, Fume RedBrown, laid on 20 mm thick cement mortar 1:4(1 Cement:4 Coarse sand), jointing with grey cementslurry@ 3.3 kg/ sqm including grouting thejoints with white cemen and matching pigmentsetc., complete.
Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately).
6 mm thick Cement fiber board as per IS: 14862
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 micron epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer?in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete.
Ridges plain (500 - 600mm).
12 mm cement plaster of mix :
1:4 (1 cement: 4 fine sand)
6 mm cement Plaster of mix:
1:3 (1 cement: 3 fine sand)
Finishing walls with Acrylic Smooth exterior paint of required shade .
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm
Distempering with 1st quality acrylic distemper (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade :
Old work (one or more coats)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade.
One or more coats on old work
Finishing walls with Acrylic Smooth exterior paint of required shade :
Old work (One or more coat applied @ 0.90 ltr/10 sqm)
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
With cement mortar 1:4 (1 cement : 4 fine sand)
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:
Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm).
Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
Of area 3 sq. metres and below
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :
Of area 3 sq. metres and below
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:
Asbestos cement sheet
Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead.
Thickness above 10 mm up to 25 mm
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.
W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap.
Providing and fixing Stainless SteelA ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink with drain board
510x1040 mm bowl depth 250 mm
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
32 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work.
20 mm nominal dia pipe
25 mm nominal dia Pipes
Providing and fixing brass bib cock of approved quality :
20 mm nominal bore
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
150 mm diameter
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in?charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately).
Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer-in-charge.
Extra for providing and fixing flat aluminum wind ties of 40x 6 mm.
Providing and fixing chrome plated health faucet of approved quality with 1.0/1.20 m flexible tube and hook complete as per the direction of engineer in charge.
Providing and fixing in positions facia or eaves board with 18mm thick and 30cm wide wooden polymer composite (wpc) board including fixing with nuts/screws/washers and bolts etc.
Providing and fixing 20mm CPVC ball valve of approved quality.
Providing and fixing UPVC (SWR) Nahani trap 110mm inlet and 110mm outlet with cover including necessary cutting, fitting and sealing, complete as per the direction of EIC:
Providing and fixing CPVC tank connector 25mm dia nominal dia in (SDR 11) of approved quality as per the direction of EIC.
Providing and fixing 35 mm thick glazed shutters for doors,windows and clerestory windows using 10 kg/sqm (4mm thick) Float glass panes including anodised aluminium butt hinges (Anodix coating not less than grade AC 10 as per IS:1868)with necessary screws etc, complete.
With Kiln seasoned and Chemicaly treated Superior Hardwood Cat-II(A)
Providing wooden polymer composite (WPC) board 12mm thick including fixing with nuts/screws/washers and bolts etc.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fastners of required dis & length (hold fast lugs or dash fastner shall be paid for seperately).
With Kiln seasoned and Chemicaly treated Superior Hardwood Cat-II(A)
S Rajan (BID ID -58991)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .