Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.2 LAccepted-AOC 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | ₹36.2 L Quoted ₹37.5 L | L1 | Accepted-AOC AOC |
| 2 | L2₹38.9 L+₹1.4 L (3.65%)Rejected-Finance | ₹38.9 L+₹1.4 L (3.65%) | L2 | Rejected-Finance Other than lowest quoted tenderer |
| 3 | L3₹47.1 L+₹9.5 L (25.4%)Rejected-Finance 12 L I G PRITAM NAGAR PRAYAGRAJ U P PIN 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | ₹47.1 L+₹9.5 L (25.4%) | L3 | Rejected-Finance Other than lowest quoted tenderer |
| 4 | L4₹48.2 L+₹10.7 L (28.4%)Rejected-Finance | ₹48.2 L+₹10.7 L (28.4%) | L4 | Rejected-Finance Other than lowest quoted tenderer |
| 5 | L5₹50.2 L+₹12.7 L (33.7%)Rejected-Finance | ₹50.2 L+₹12.7 L (33.7%) | L5 | Rejected-Finance Other than lowest quoted tenderer |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
27 Feb 2021, 6:00 pmClosed
GE WEST ALLAHABAD
GE WEST NEW CANTT ALLAHABAD
REPAIR / MAINTENANCE OF LT PANELS/FEEDER PILLAR BOXES AMP PANELS AND CONNECTED WORK NEW CANTT ALLAHABAD
2020_MES_408277_2
8950/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
NEW CANTT
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE WEST ALLAHABAD
₹90,000
Yes
19 Mar 2021
18 Feb 2021
1 Mar 2021
18 Feb 2021
27 Feb 2021
22 Feb 2021
Amount
M&L for checking all connections and Mechanism, cleaning, servicing, overhauling, testing complete and repair for at automatic power factor correction panel (APFC) upto 250 KVAR by taking out 4mv heavy duty capacitor banks of existing rating/Size/Steppings 3 Phase 415 suitable for having losses not less than 0.5 w/KVAR with discharge registors. Including Replacement of minor/major parts if required for smooth functioning complete all as specified & directed by Engi-in-charge. NOTE:- (i) Cost of major/minor parts required for replacement shall be measured and paid separately as supply only under relevent item of this schedule/BOQ from SI No. 1.01 to 1.14. (ii) All the instruments and T&P required for the above jobs shall be arranged by the contractor at site and cost of the deemed to be included in the above rates. (iii) The all above checking, inspection, installation & testing work shall be performed by authrised manufacturer or expert electrical engineer of company.
Supply only capacitor 5 KVAR capacity Make : L&T/Schneider electric/or as approved.
Supply only capacitor 7.5 KVAR capacity Make : L&T/Schneider electric/or as approved.
Supply only capacitor 10 KVAR capacity Make : L&T/Schneider electric/or as approved.
Supply only capacitor 12.5 KVAR capacity Make : L&T/Schneider electric/or as approved.
Supply only capacitor 15 KVAR capacity Make : L&T/Schneider electric/or as approved.
Supply only capacitor 20 KVAR capacity Make : L&T/Schneider electric/or as approved.
Supply only capacitor 25 KVAR capacity Make : L&T/Schneider electric/or as approved.
Supply only capacitor 50 KVAR capacity Make : L&T/Schneider electric/or as approved.
Supply only MCCB TPN 160 Amp, 25 KA capacity Make : L&T/Schneider electric/or as approved.
Supply only MCCB TPN 200 Amp, 25 KA capacity Make : L&T/Schneider electric/or as approved.
Supply only MCCB TPN 250 Amp, 25 KA capacity Make : L&T/Schneider electric/or as approved.
Supply only LED phase indicator lamp.
Supply only contactor having current lighting resistors suitable for capacitor Switching off variable KVAR correctiong of specification as approved.
Supply only Varlogic APFC Relays of exhisting size/capacity.
Disconnecting & dismentling of damaged/unserviceable cable any type /make and Supply & laying (in repair) cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor using lugs bothe end of cable& wrapping pvc tape over XLPE insulation cable and testing complete all as directed for following size :- (Note :- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid seperately)
10 Sqmm 4 core
50 Sqmm 3.5 core
70 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
400 Sqmm 3.5 core
Excavation in trenches in soft/ loose soil n.exc 1.5 m wide and n.exc. 1.5 mtr deep and getting out and laying LT UG Cable complete all as specified and directed .
Returning filling in with the soil obtained from item above here-in-before includiing spreading , leveling and well ramming in layers n.exc 25 cm thick complete all as specified and directed.
Removal of surplus excavated soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc.1.5 mtr above starting point complete all as specified and directed
Supply and laying sub class 'B' brick old size laid flat in trenches across the length for protection of cable as cable cover complete all as specified and directed .
M& L for sand cushioning in trenches for protection of under ground cable provided in layers of sand as 8 cm before laying the cable and 15 cm deep after laying cable complete all as specified and directed.
M&L (in replacement) for GI tubing 'light grade' eith all necessary fittings laid in treches/under road crossing/fixed on pole/wall/under floor including suitable mild steel FI clamps of required size complete for following sizes:-
50 mm bore
80 mm bore
Dismantling & taking out defective LT PVC/XLPE cable from trenches with cutting and removing defective parts and supply & making cable joint using straight through joint heat shrink type ad making connection of LT cables, megering & re-storation of electric supply complete including jointing material for the following sizes of cable :- Joint make - Reychem
25 Sqmm 3.5 core to 70 Sqmm, 3.5 core
95 Sqmm 3.5 core to 240 Sqmm, 3.5 core
S&F (in replacemement) following items in the existin out door/indoor LT panels and connetion with using aluminum lugs/ferruls incl disconnection & connection of cable and making necessary alteration in panel/door using welding wk and cutting as required for proper fixing & connection complete all as specified and directed as below :- (Note :- Make of MCCB/MCB : Schneider/L&T/ABB)
MCCB 4 pole 100 amps rating, 35 KA breaking capacity, with separator at both side
MCCB 4 pole 150/160 amps rating, 35 KA breaking capacity, with separator at both side
MCCB 4 pole 200 amps rating, 35 KA breaking capacity, with separator at both side
Microprocessor based MCCB 4 pole 250 amps rating, 35 KA breaking capacity with spreader at both side
Microprocessor based MCCB 4pole315 amps rating, 35 KA breaking capacity with spreader at both side
Microprocessor based MCCB 400 amps rating, 50 KA breaking capacity with spreader at bothe side
Supply, fixing ( in replacement ), connecting to electrical system & testing of LT Panel, cubical types, for out door use, made out of 3.0 mm thick CRCA sheet factory made, totally enclosed of size not less than 1400x1000x600mm & supported with 4 Nos MS Angle legs , duly painted with two coats of powder coated paint over one coat of red oxide primer effectively PVC gaket &sealed and mounted on PCC blocks double door type with locking arragnedment with handle at front and openable at front &back bothe side with required hinges heavy duty, compartemtalised suitably including provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs glands and comprising of the following accessories :- (a) High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of 800 amps rating (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set. , (b) Phase indication lamp, LED type(set of 3) (c) MCCB 4 Pole 400 Amp 415 volt ,36 KA breaking capacity as incomer. ( Make : Schnieder/Havells/L&T/ABB) (d) Grouting of panel including earth work as required PCC (1:3:6) type D-2 using 20 mm gradeded stone & plastering with (1:4 )cement sand etc complete (e) MCCB 4 Pole 250 Amp 415 volt ,36 KA breaking capacity with spreader bothe side, as outgoing cotrol device : 02 Nos. ( Make : Schnieder/Havells/L&T/ABB) (f) MCCB 4 pole 160 Amp 415 volt rating & breaking capacity 25 KA with spreader at bothe side. : 3 Nos ( Make : Schnieder/Havells/L&T/ABB) (g) On Load Change over switch of 300/320 Amp, 4 Pole - 02 Nos ( Make : Schnieder/Havells/L&T/ABB)
Supply, fixing ( in replacement ), connecting to electrical system & testing of LT distribution panel board CPRI approved make ,cubical type for indoor use, made out of 3.0 mm thick CRCA sheet factory made, totally enclosed of size not less that 2300x2100x1000 mm and supported with 4 Nos MS Angle legs , duly painted with two coats of powder coated paint over one coat of red oxide primer effectively PVC gaket and sealed mounted on PCC blocks double door type with locking arrangment with handle at front and openable at front & back bothe side with required hinges heavy duty, compartemtalised suitably including provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs glands and comprising of the following accessories (a) High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of 1400 amps rating (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set. (b) Phase indication lamp, LED type(set of 3) -1 Set (c) Ammeter anolog type having measuring range (0-500) Amps with CTs etc including rotary switch to measure load of each phase : Schneider/Seimens/L&T
(d) Volt meter having measuring range (0-500) volt with rotary switch to measure voltage of phase R.Y.B make : L&T/AE (e) ACB 4 Pole 800 Amp 415 volt with 50 KA breaking capacity & spreader both side as Incomming cotrol device : 01 Nos.( Make : Schnieder/Havells/L&T/ABB) (f) MCCB 4 Pole 400 Amp 415 volt thermal adjustable, with microprocessor type with 36 KA breaking capacity & spreader both side as Incomming cotrol device : 04 Nos. ( Make : Schnieder/Havells/L&T/ABB) (g) MCCB 4 Pole 320 Amp 415 volt thermal adjustable , with microprocessortype with 36 KA breaking capacity & spreader both side as Incomming cotrol device : 02 Nos. ( Make : Schnieder/Havells/L&T/ABB) (h) MCCB 4 Pole 250 Amp 415 volt thermal adjustable , with microprocessor type with 25 KA breaking capacity & spreader both side as Incomming cotrol device : 01 Nos. (Schnieder/Havells/L&T/ABB) (i) Grouting of panel including earth work as required PCC (1:3:6) type D-2 using 20 mm gradeded stone & plastering with (1:4 )cement sand etc complete. (j) On Load Change over switch of 600 Amp, 4 Pole - 02 No (Schnieder/Havells/L&T/ABB)
Supply, fixing testing and commissioning battery bank of 30 volt DC lead acid chargeable stationary battery set comprising of 15 cells of 02 volts each having 90 Amp hour capacity with minimum maintenace free batteries complete all as specified and directed by Engi-in- charge.Make: Exide/Amron
Supply, fixing ( in replacement ), connecting to electrical system & testing of Busbar panel board ,cubical type for out door use, made out of 3.15 mm thick CRCA sheet factory made, totally enclosed of size not less that 900x600x500mm and supported with 4 Nos MS Angle legs , duly painted with two coats of powder coated paint over one coat of red oxide primer effectively PVC gaket and sealed mounted on PCC blocks double door type with locking arragnedment with handle at front and openable at front &back bothe side with required hinges heavy duty, compartemtalised suitably including provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs glands and comprising of the following accessories :- (a) High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of 300 amps rating (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set. , (b) Phase indication lamp, LED type(set of 3) -1 Set (c) Ammeter anolog type having measuring range (0-300) Amps with CTs etc including rotary switch to measure load of each phase : L&T/Seimens (d) Replacement of volt meter having measuring range (0-500) volt with rotary switch to measure voltage of phase R.Y.B make : L&T/AE (e) Grouting of panel including earth work as required PCC (1:3:6) type D-2 using 20 mm gradeded stone & plastering with (1:4 )cement sand etc complete. (f) MCCB 4 Pole 250 Amp 415 volt thermal adjustable ,type with 25 KA breaking capacity & spreader both side as Incomming cotrol device : 01 Nos. (Schnieder/Havells/L&T/ABB)
S&F in replacement of PVC insulated PVC sheathed stranded copper conductor cable 2.5 Sqmm two core complete all as specified and directed.
S&F rigid PVC conduite 'medium grade' of size 15 mm bore incl fittings, ISI marked, fixing with PCC pole/ steel tubular pole for wiring connection from pole box to light fitting and supporting with 03 Nos GI strip clamp , nut bolt and complete all as specified and directed.
S&F MS bracket for mounting flood light fitting made out of MS angle iron of size 40x40x6 mm of length not less than 1.o mtr, fixed to pole/ earth and grout using pcc & clamp, nut & bolts including painting of bracket with one coat of synthetic enamel paint over a coat of red oxide primer complete
S&F( in replacement) Pole box three phase of size 297x 250 x 130 mm made out of 2 mm MS sheet factory made with inbuilt locking arrangement, out door type , fix to pole with suitable MS clamp comprising of alluminium busbar 16 Amp 04 Nos fixe on epoxy insulated pole and MCB 6 Amp 10 kA 240 volt complete all as specified and directed.
S&F (in replacemement) of Changeover switch in the existing out door/indoor LT panels/wall and connetion with using aluminum lugs/ferruls incl disconnection & connection of cable and making necessary alteration in panel/door/wall using cutting/ chasing as required for proper fixing & connection complete all as specified and directed by Engi-in-Charge. Make:Havells/L&T/C&S/Indoasian)
On Load Change over switch of 200 Amp, 4 Pole
On Load Change over switch of 300/320 Amp, 4 Pole
On Load Change over switch of 400 Amp, 4 Pole
On Load Change over switch of 600 Amp, 4 Pole
Off Load Change over switch of 200 Amp, 4 Pole
Off Load Change over switch of 400 Amp, 4 Pole
Off Load Change over switch of 600 Amp, 4 Pole
Taking out stone aggregate from Sub Station and refilling evenly (any thickness) for neat look surfaces after surface dressing n.exc. 25 cm deep in soft/loose soil rough excavating of un-even surfaces and filled up in low patches with scraped soil to give even and neat look surfaces by removing/uprooting all vegetation hedges shrubs at sub stations and sprinkling of pesticide two times during the periods for preventing any growing of vegetation/shrubs complete all as specified and directed by Engi-in- Charge.
M&L for spreading and levelling evenly (any thickness) hard core using 40mm graded stone aggregate at sub-station complete all as specified & directed.
Titco Electricals
M/s SINGH CONTRACTOR WORKS
ASIA ENGINEERING WORKS
Avion Industries
M/s RAM LAKHAN GUPTA
SUNNY ELECTRONICS CORPORTAION
oasis contractor builder and supplier
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .