Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.3 LAccepted-AOC 3 224 RUI KI MANDI SHAHGANJ AGRA 282010 | AGRA | UTTAR PRADESH | 282010 | 1 | Accepted-AOC Being lowest | |
| 2 | 2₹16.7 L+₹86,207.50 (5.46%)Rejected-Finance | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹16.9 L+₹1.1 L (7.22%)Rejected-Finance 59 100 AJIT NAGAR GATE KHERIA AGRA 282008 | AGRA | AGRA | UTTAR PRADESH | 282008 | 3 | Rejected-Finance Not being lowest | |
| 4 | 4₹18.2 L+₹2.4 L (15.4%)Rejected-Finance | 4 | Rejected-Finance Not being lowest | |
| 5 | 5₹20.5 L+₹4.7 L (29.6%)Rejected-Finance FLAT NO 404 BLOCK II NIRMAL HEIGHT SECTOR 12A OLD MATHURA ROAD AGRA 282007 UP | AGRA | AGRA | UTTAR PRADESH | 282007 | 5 | Rejected-Finance Not being lowest |
Tender Value
₹21.8 L
EMD Value
₹43,600
Closing Date
18 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE AGRA
112 Taj Road Agra Cantt
SPL REPAIR TO BLDG NO.P-31 (08 QTRS) AT WAC LINES OF COD AGRA UNDER GE (WEST) AGRA
2021_MES_423349_1
84204/E8
Open Tender
Civil Works
Item Rate
180 days
Agra
MES contractors enlisted in Class E category a(i) for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work
8 documents required · 8 mandatory
₹500
GE WEST AGRA
₹43,600
Yes
27 Mar 2021
18 Feb 2021
24 Mar 2021
18 Feb 2021
18 Mar 2021
4 Mar 2021
18 Feb 2021 - 25 Feb 2021
60 days
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (above or below ground level )complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of ( reinforced) cement concrete (reinforcement cut as required to facilitate demolition) for roof , floors( other than ground floors) beams, staircase,landing, chajjas and similar suspended work complete all as specified and directed
Supply only integral water proofing compound ISI Marked complete all as specified and directed.
Demolition of brick or stone boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone works and precast concrete articles, complete all as specified and directed
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing tiles and rubbish off the premises, complete all as specified and directed.
M&L Brick work with sub class B bricks, old size, straight or curved on plan exc 6m mean radius built in CM 1:6 Complete all as Specified and directed
M&L for brick work (except bricks), straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar 1:6 complete all as specified and directed. NOTE:- Old bricks retrived under item No.5 above shall be reused duly cleaning of motar etc.
M&L for cutting holes into or through brick walls built in cement mortar or cement lime mortar and super ficial area n.exc. 150 Sqcm and making good in cement mortar 1:3 or PCC 1:2:4 type B-1, as required complete all as specified and directed.
S&F rolled mild steel Joist, channel, angle or tee sections fixed independently without connecting plate etc. (cut to ordinory length i.e. within 20 mm of the length indicated) conforming to Fe-410-W (Gde- E- 250) quality A complete all as specified and directed.
M&L for second class hardwood hand rails rounded or shaped with splayed faces in straight length and fixed of size 75 x 60 mm complete all as specified and directed.
S&F 5.0 cm thick sand stone slabs in sun shades, chajjas, shelves, cills, landing etc n. exc. 2 m in length punched dressed on face and along exposed edges, self faced on other side and set and pointed in CM 1:4 complete all as specified and directed.
M&L for Cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in roof kerbs or mud stops, gola rounded or chamfered on edges complete all as specified and directed.
Taking down cement or cement lime plaster of any description including racking out joints, hacking for keys ,scrubbing down with water etc complete all as specified and directed.
M&L Rendering 15 mm thick in CM (1:6) on fair faces of brick work or concrete surfaces of wall and finishing the surfaces even and smooth (without using extra cement) complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of concrete/ brick surface in cement mortar 1:4 including finishing the surface fair and even with using water proofing compound as per manufacturer's instructions complete all as specified and directed. Note:- Water proofing compound shall be measured and paid for seperately under respective item of Schedule 'A'.
S&F galvanized welded steel wire fabric as extra reinforcement to RCC members like ceilings, chajjas,beams, columns parapet walls, waste slab etc including fitting to ceiling, all cutting and waste (wt not exc. 4.00Kg Per Sqm) complete all as specified and directed.
M&L for rendering 10 mm thick on fair faces of concrete surface in cement mortar 1:4 finished fair and even as on ceiling surface complete all as specified and directed.
M & L for applying three coats of white wash on wall including prepration of newly plastered surfaces of walls complete all as specified and directed.
M&L for applying three coats of white wash on ceiling including preparation of newly plastered surfaces complete all as specified and directed.
M&L preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of suitable primer on walls. complete all as specified and directed.
M&L for preparing newly plastered surfaces of wall & applying of Birla/JK white wall care putty 1 to 1.5 mm thick on prepared surface for smooth finishing and applying two coats of oil emulsion distemper over a coat of primer over putty surface complete all as specified and directed.
M&L for preparing old decorated surfaces of walls plastered or un-plastered by brooming down with steel or wire brush and scraping down smoke moulds moss & efflorescence salt etc & applying one coat of white wash complete all as specified and directed.
M&L for preparing old surfaces of ceiling plastered or un-plastered by brooming down with steel or wire brush and scraping down smoke moulds moss & efflorescence salt etc & applying one coat of white wash on ceiling complete all as specified and directed.
M&L for preparing old surfaces of walls plastered or un-plastered by brooming down with steel or wire brush and scraping down smoke moulds moss & efflorescence salt & removing all vegetation growth etc & applying one coat of cement base paint on old decorated cement based painted surfaces of walls complete all as specified and directed.
M&L for preparing of old surfaces of wall by rubbing down or stopping distempered or painted surfaces and applying one coat of distemper oil emulsion complete all as specified and directed.
M&L for preparing old decorated surfaces plastered or un-plastered (as in band strip in narrow width or similar work) by brooming down with steel or wire brush and scraping down smoke moulds moss & efflorescence salt etc & applying one coat of weather proof exterior paint silicon based on old decorated surfaces complete all as specified and directed.
M&L for glazed coloured ceramic tiles ,first quality ( of approved class , colour and design/ shade ) of size 350 x 250 x 7mm / 450 x 350 x 7mm thick in vertical surfaces, as in dado / skirting etc set & jointed in neat cement slurry & pointed in coloured cement to match with shade of coloured tiles, over and including 10 mm thick rendering in cement mortar (1:3), rough finish to receive the tiles complete all as specified and directed.
M&L for non skid coloured Ceramic tiles, joint free, first quality( of approved class , colour and design/ shade ) 7 to 8 mm thick (Square/ rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm, ,as in floor surface etc set and jointed in neat cement slurry and pointed in coloured cement to match with shade of coloured tiles over and including 15 mm thick screed bed in Cement mortar 1: 6 Complete all as specified and directed.
M&L for non skid coloured Ceramic tiles, joint free, first quality( of approved class , colour and design/ shade ) 7 to 8 mm thick (Square/ rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, ,as in floor surface etc set and jointed in neat cement slurry and pointed in coloured cement to match with shade of coloured tiles over and including 15 mm thick screed bed in Cement mortar 1: 6 Complete all as specified and directed.
M&L for machine cut kota stone slab as in flooring 20 to 25 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone slab including grinding, rubbing and polishing to mirror finish with & including screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and directed
M&L for machine cut kota stone slab 18 to 20 mm thick as in vertical surfaces, as in skirting etc(cut to required size) set and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing to mirror finish over and including 10 mm thick rendering in cement mortar (1:3), rough finish to receive the stone slab complete all as specified and directed.
Taking up or down existing 15 mm dia GI tubing and connections, including cleaning for refixing and making good the disturbed surface complete all as specified and directed.
Taking up or down existing 20 mm dia GI tubing and connections, including cleaning for refixing and making good the disturbed surface complete all as specified and directed.
Supply, fixing, laying & testing 15 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Supply, fixing, laying & testing 20 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
M&L for refixing old steel tubing and connections in new or old position (walls, ceiling, floors, etc.) for 15 mm dia pipes with and including all new fittings complete all as specified and directed. Note:- GI pipe shall be reused, received under Item No.33
M&L for refixing old steel tubing and connections in new or old position (walls, ceiling, floors, etc.) for 20 mm dia pipes with and including all new fittings complete all as specified and directed. Note:- GI pipe shall be reused, received under Item No.34
M&L for cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills sunshades, shelves lintels etc and cutting chases for concealed water pipe etc and making good cutting not exc 10 cm.complete all as specified and directed.
S&F in repair bib tap standard 15 mm bore high presure of PTMT, any colour, screwed, for iron pipe and fixed (minimum weight not less than 90 grams) complete all as specified and directed.
S&F in repair bib tap long body 15 mm bore high presure of PTMT, any colour, screwed, for iron pipe and fixed (minimum weight not less than 90 grams) complete all as specified and directed.
S&F in repairs PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic action type with inlet ball valve and float, handle with & including fixing arrangment and PVC flush pipe 32 mm bore complete all as specified and directed
S&F in repairs angle / stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handles, screwed both ends for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed.
S&F in repairs fancy type, stop cock regular body 15 mm nominal bore with flange, brass, chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butterfllly handles, screwed both ends for iron pipe or for brass ferrule or to GI socket complete all as specified and directed.
S&F in repairs swivel shower of PTMT any colour for fixing with 15 mm pipe (minimum weight not less than 40 gms) complete all as specified and directed.
S&F in repair for towel rail 600 mm long of PTMT (minimum weight 190 grm) fixed to rawl plugs with chromium plated brass screws & washers complete all as specified and directed.
S&F in repair PVC connection pipe 600 mm long suitable for 15 mm GI pipe with PTMT nuts & rubber washers complete all as specified and directed.
S&Fixed in repair vitreous china wash hand basin (flat back) of size 550x400mm with and including MS brackets 2 numbers including cutting for and pinning in ends of brackets complete all as specified and directed.
Taking out existing wash hand basin carefully and refixing is same or in other location with and including 02 Nos new MS bracket and cutting for and pinning in ends of brackets complete all as specified and directed.
S&F pillar tap 15 mm bore high presure of PTMT, any colour, screwed for iron pipe and fixed (minimum weight not less than 110 grams) complete all as specified and directed.
S&F 32mm dia waste coupling of PTMT (half or full threaded) minimum weight not less than 45 grams for WHB/sink complete all as specified and directed.
S&F PVC waste pipe flexible type 32 mm dia suitable for couplings 32 mm , 800 mm long for WHB/Sink complete all as specified and directed.
S&F in repair PVC waste pipe flexible type 32 mm dia suitable for couplings 32 mm , 800 mm long for WHB/Sink complete all as specified and directed.
S&F in repair PVC (SWR) pipe 75 mm bore, single socketed, in any length with rubber ring joints fixed on wall etc confirming to IS 13592 complete all as specified and directed.
S&F PVC (SWR) bend 75 mm dia any radius as required and jointed with approved adhesive complete all as specified & directed.
S&F PVC (SWR) junction single 75 mm bore single T (equal or unequal) complete all as specified and directed.
S&F in repair PVC (SWR) pipe 110 mm bore, single socketed, in any length with rubber ring joints fixed to wall conforming to IS 13592 complete all as specified and directed.
S&F PVC (SWR) branch piece,110 mm bore, double (double Y) equal or unequal and jointed with approved adhesive complete all as specified & directed.
S&F PVC (SWR) bend 110 mm dia, any radius as required and jointed with approved adhesive complete all as specified & directed.
Cleaning of roughened surface of sunken floor by brushing with wire brush to remove all dirt and apply a coat of cement slurry with 3.00 Kg of cement per Sqm and rendering 15 mm thick in CM 1:3 using WPC finished even and smooth (sunken floor / wall) and then following treatment as follow :- (i) Preparation of surface and applying one priming coat of oil based bituminous primer @ 0.30 kg / sqm. (ii) Applying one coat of hot blown bitumen grade 85/25 @ 1.2 Kg/Sqm . (iii) Laying APP modified polymeric water proofing membrane 3 mm thick of weight not less than 3.00 kg / sqm . (iv) 40 mm bore GI pipe for spout pipe length 0.75 m.
M&L for plain cement concrete 1:5:10 type E-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete, sub base complete all as specified and directed.
S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest (excluding flushing cistern and flush pipe) & including CI trap & connecting fitting as required set in plain cement concrete (1:3:6) type C-1 and connecting to flusing cistern and trap & connecting fittings as required and making good to floor, complete all as specified and directed.
S&F in repair rotational moulded polyethylene water storage tanks 500 lts capacity (cylinderical vertical with closed top) hoisted and fixed in position all as per SSR Part I complete all as specified and directed
S&F for ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm bore and fixed, minimum weight of float valve 210 gms complete all as specified and directed.
S&Fixed in repair ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm bore and fixed, minimum weight of float valve 210 gms complete all as specified and directed.
S&F in repair sinks with drainage board made of stainless steel 1.00 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm with & including one chromium plated suitable waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement ,with PVC coupling, PVC waste pipe 40mm bore 750mm long complete all as specified and directed.
S&F in repair Plate rack with & including shelves and hanging arrangements for utensil for kitchen , made of stainless steel 1 mm thick ,size 900 mm x 600mm x 250mm complete all as specified and directed.
Taking down Chowkhats or frames with shutter (without taking off shutters from the frame) n. exc. 1.50 sqm each complete all as specified and directed.
S&F steel windows with side hung shutters including box type hinges with steel handle, and 125 mm MS tower bolt 2 Nos in each leaf and steel peg stay complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F steel windows with side hung shutters including box type hinges with steel handle, and 125 mm MS tower bolt 2 Nos in each leaf and steel peg stay complete without glazing bars, dovetailed or welded complete all as specified and directed.
S&F steel ventilator with top hung shutters including box type hinges with steel peg stay complete complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces not exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
M&L for preparing of old painted steel surfaces n.exc 10cm width or girth & applying one coat of synthetic enamel paint complete all as specified and directed.
S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framed work and similar works conforming to Fe-290 Gd E-165 complete all as specified and directed.
M&L for 3 mm thick sheet glass ordinary quality and glazing with steel pin and oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed.
M&L for 3 mm thick figured glass pin headed type and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed.
Taking down Chowkhats or frames with shutter (without taking off shutters from the frame) exc. 1.50 sqm and n. exc. 4.00 sqm each complete all as specified and directed.
Taking down shutter of any description exc 1 Sqm and n.exc 2 Sqm each complete all as specified and directed.
M&L for resecuring or easing & adjusting shutters of any description (without taking down shutters of size exc. 1.00 Sqm and n.exc. 2.00 Sqm) complete all as specified and directed.
S&F in repair 100 mm size mild steel butt hinges, ISI marked, medium weight, cold rolled and fixed with screws/welded to frame complete all as specified and directed.
S&F rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, etc., drilled for fixing of steel sheeting or other covering to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe- 290.Gde-E-165 complete all as specified and directed.
S&F mild steel work as in bands, straps, supports or stays for rainwater, Ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three ways straps, plate washers and similar small articles conforming to Fe-290 or E-165 complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, copings, holdfast and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including necessary form work complete all as specified and directed.
S&F 100 mm size mild steel butt hinges, ISI marked, heavy weight, cold rolled and fixed with screws/welded to frame complete all as specified and directed.
M&L in repair for mild steel, plain, black sheet of 0.63 mm thickness in wall cladding, steel gates and similar work, cut to size, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc as required complete all as specified and directed.
M&L 300mm long MS sliding door bolts ISI marked bolt type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed all as specified and directed.
S&F for 30 mm thick flush shutters, solid core construction, with block board core and plywood face, pannels, commercial type on both sides including provision of suitable blocks for taking mortice locks, latches or other fittings complete all as specified and directed.
S&F 100 mm size mild steel butt hinges, ISI marked, medium weight, cold rolled and fixed with screws/welded to frame complete all as specified and directed.
S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed all as specified and directed.
S&F solid PVC door frame of size 50mmx 47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube as per specification & drawings specified in SSR Part-II 2010 complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement as per specification & drawings shown in section 8 of SSR Part-II 2010 complete all as specified and directed.
S&F 100 mm size stainless steel butt hinges, ISI marked, medium weight, cold rolled and fixed with screws/welded to frame complete all as specified and directed.
S&F aluminium anodised barrel tower bolt of extruded section 150 mm long and fixed complete all as specified and directed.
S&F extruded aluminium alloy handles, fabricated type, anodised 150 mm size complete all as specified and directed.
S&F factory made glazed and Skelton 35mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc; sizes of members of shutters as specified in SSR Part-I section 8, clause 8-24 (a) complete all as specified and directed..
S & F Galvanized mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned stacks, or galvanized wire staples complete all as specified and directed
S & F in repair Galvanized mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned stacks, or galvanized wire staples complete all as specified and directed
S&F 25 mm thick flush shutters, solid core construction, with block board core and plywood face, pannels, commercial type on both sides including provision of suitable blocks for taking mortice locks, latches or other fittings complete all as specified and directed.
S&F in repair 18/19 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws to timber frame work work as in shelves, partitions, shutters, cabinet of kitchen and sealing edges of board with 6mm thick wooden beading (teak) by chemical adhesive complete all as specified and directed.
S&F 75 mm size mild steel butt hinges, ISI marked, medium weight, cold rolled and fixed with screws/welded to frame complete all as specified and directed.
S&F aluminium anodised barrel tower bolt of extruded section 75 mm long and fixed complete all as specified and directed.
S&F in repair extruded aluminium alloy handles, fabricated type, anodised 100 mm size complete all as specified and directed.
S&F in repair 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed all as specified and directed.
S&F in repair aluminium anodised barrel tower bolt of extruded section 150 mm long and fixed complete all as specified and directed.
S&F in repair extruded aluminium alloy handles, fabricated type, anodised 150 mm size complete all as specified and directed.
S&F aluminium anodised hasp and staple, safety type including bolt to hinge plate 100 mm long and fixed with screws complete all as specified and directed.
S&F in repair drapery curtain rod 25 mm dia, high Strength aluminium rod with PVC coated with minimum 8 rings in each metre length of rod of ABS Plastic in matching colour & installations brackets of galvanised steel, powder coated paint in matching colour with all accessories complete all as specified and directed.
M&L for preparing of old painted wooden surfaces over 10cm width or girth & applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new or previously untreated wooden surfaces exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed.
S&F in repair PVC grating doom 125 mm dia of PTMT (minimum weight not less than 40 grams) with openable flap complete all as specified and directed.
Taking down carefully existing unserviceable copper / aluminum point wiring of any description & in any position with and including taking out existing unserviceable conduits or battens of any description with sunken boxes/junction boxes and all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings, lamp holders etc but excluding tube light fittings and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed.
Material and labour for point wiring for one light point or one fan or bell point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC (FRLS) insulated & unsheathed cable, 1100 volts grade in and including concealed PVC conduit (Medium grade) of suitable size all as directed with using new sunken type pressed steel box / terminal boxes for mounting fittings/junction boxes not less than 1.6mm thick duly painted with two coats of black bituminous paint over a coat of red oxide primer with 3mm thick bakelitelaminated sheet, and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed.
All as per Srl item No 114 here in above but point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board controlled by one switch.complete all as specified and directed.
All as per Srl item No 114 here in above but point wiring for 5 pin switch socket outlet, 5 Amps on same board with other switches omplete all as specified and directed.
All as per Srl item No 114 here in above but point wiring for one six pin socket outlet, 15 & 5 Amps (independent) controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor omplete all as specified and directed. Notes for item 114 to item 117 here in before : (i) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at RCC Columns/Beams/Ceilings shall be in surface conduit of suitable size fixed on surface with using PVC rawl plugs and provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick bakelitelaminated sheet fixed with suitable GI screws and cup washers) (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A' (iii) The size of conduits shall be determined on permissible No. of runs of wires as specified in SSR Part-I (2009) clause 19.125 (B). However minimum size of conduit shall be 20mm dia (Medium grade)
All as per item No.114 here in above but one light point controlled by two way switches complete all as specified and directed.
Supplying & fixing for piano switch flush type, 5/6 Amps, single pole, one way , 230 volts AC circuit complete all as specified & directed.
Supplying & fixing for switch bell, push type, 5/6 Amps single pole one way, 230 volts AC circuit complete all as specified and directed.
Supplying & fixing for piano switch flush type, 5 Amp, single pole, two way, 230 volts AC circuit complete all as specified and directed.
Supplying & fixing for piano switch flush type, 15/16 Amps, single pole, one way , 230 volts AC circuit complete all as specified & directed .
Supplying & fixing for socket outlet, five pin, 5/6 Amps, flush type, 230 volts AC circuit complete all as specified & directed .
Supplying & fixing for socket outlet, multipurpose, three pin, 15/16 Amps & three pin 5 Amps controlled by one switch , flush type, 230 volts AC circuit complete all as specified & directed.
Supply and fix ceiling rose, 3 phase / PVC / polycarbonate, isolated body surface bakelite 62.5 x 25 mm dia three terminals complete all as specified and directed.
S&F lamp holder / angle holder insulated body with black / white plate for batten fittings complete all as specified and directed.
Supply and fixing LED Bulb 15 watt suitable for lamp holder complete all as specified and directed.
Supply and fixing fan regulator electronic, step type, suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supply 100Watt complete all as specified & directed.
S&F in replacement LED battan surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption < 20W, luminaire lumens > 2000 lms, system efficiency of > 120 lumens / W, LED of make : Nichia / Cree / Everlite / Eclison / OSRAM / Lumiled, with LED binding as per ANSJ Bin C78377A, Ingress protection IP 20, colour rendering index CRI > 80, temp range 0 to 45 ºC, driver efficiency > 85%, power facor > 0.95 THD < 20% as per IEC 61000-3-2, colour temp - 6500 K Surge protection 2.5 KV, 50000 burning hrs (min) as per L 70 criteria, two stages isolated constant current operated driver with range 150 - 270 VAC and safety extra low voltage safe level < 60 VDC as per IEC standard with LM 70 & 80 certification complete all as specified Make :- Wipro Model No.LL20-281 - XXX-65AL1 or equivalent of philips / Balaj / Havells
Disconnecting and taking out existing street light fitting of any type,any description and in any position on poles or fixed on walls complete and Supply & fix LED security light compact & trendy of 30 watt with aluminium pressure diecast housing, high purcity PC Fresnel diffuser with silicon gasket for IP 65 protection, power consumption < 30W & luminaire lumens > 2500 lumens/W and system efficiency > 125 lumens/W, in built electronic driver prewire upto terminal block with driver efficiency > 85 %, power factor > 0.95 suitable for enternal pole upto 35 mm, LED make :- Nichia / Cree / OSRAM/Everlite/Lumiled / Eclison, CRI > 70, suitable for ambient temp range of 0-50 ºC, THD <20% as per IEC 61000-3-2, colour temp 5700 K Surge protection 3.5 KV, 50000 burning hrs (min) as per L70 Criteria, multi stage constant current operated driver with range 150-270 VAC and safety exra low voltage safe load < 60 VDC as per IEC standards with LM 70 & 80 certification complete all as specified, fixed to pole or wall of buiding with and including suitable Bracket made out of 40 mm dia GI light grade pipe, 1.20 m long bent to shape by cutting & welding as required & directed and fixed with two Nos of FI clamps 50x6 mm to be tightened with suitabe size of bolts, nut and washers and including painted with two coat of aluminium paint over a coat of red oxide primer, and including connecting the fitting to electric source with & including twin twisted copper flexible wire of size 0.75 Sqmm including all accessories and fixing arrangements for fixing the light fitting complete all as specified & directed. Cat part No :- LR02-331-XXX-57-XX of Wipro or equivalent of Philips / Bajaj / Havells
Supplying & fixing in replacement for electric bell (Ding dong), 230 volts AC circuit complete all as specified & directed.
Disconnecting & taking up or down existing unserviceable sub main wiring of copper/aluminium conductor with two run of single core cable with one run of single core earth conductor cable of any description, any size & in any position including taking out existing unserviceable conduits or battens of any description and making good the disturbed surfaces to the existing surfaces all as specified and directed. (NOTE : Two run of single core PVC cable with one run of earth conductor and conduit /batten shall be measured as one unit.)
M&L for sub main wiring using two single core PVC (FRLS) insulated, unsheathed stranded copper conductor cable of size 6 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of dia not less than 20 mm with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 2.5 Sqmm as earth continuity conductor connected to earth dolly complete all as specified and directed. (NOTE : Two run of single core PVC cable with one run of earth conductor and conduit /batten shall be measured as one unit.)
Disconnecting and taking down old unserviceable distribution boards any size any type including MCB TPN/SPN/SP etc and making good the disturbed surfaces to the existing surfaces complete all as specified and directed.
Supply, fixing, connecting & testing factory made, epoxy powder coated, distribution board (sheet metal encloser) , triple pole and neutral, 4 ways, (Vertical DB's) ,with metal door and fixed flush to wall and suitable for universal mounting with having copper bus bars of capacity 200 Amps rating, of suitable size , for double door and suitable for using MCCB, 4 Pole as incomer and SP MCBs as out going, conforming to IS : 13032 complete all as specified & directed, ( Note: Switchgears shall be measured and paid for separately under appropriate item of Sch ‘A’.
Supply, fixing, connecting & testing factory made, epoxy powder coated, distribution board (sheet metal encloser) , singe pole and neutral, 8 ways, (Horizontal DB's) ,with metal door and fixed flush to wall and suitable for universal mounting with having copper bus bars of capacity 200 Amps rating, of suitable size , for double door and suitable for using MCB, SPN as incomer and MCBs SP as out going, conforming to IS : 13032 complete all as specified & directed, ( Note: MCBs shall be measured and paid for separately under appropriate item of Sch ‘A’.
Supply and fix in replacement MCCB Triple pole Neutral, 415 volts 50 Hz of capacity 100 Amps with rupturing capacity 16 KA 'C' series suitable for mounting in vertical TPN DB including providing thimble for incoming cable complete all as specified and directed.
Supplying & fixing MCB single pole, 40 Amps (`C’ series ) having short circuit rating 10 KA, 240 volt complete all as specified and directed.
Supplying & fixing MCB SPN, 40 Amps (`C’ series ) having breaking capacity 10 KA, 240 volt complete all as specified and directed.
Supplying & fixing MCB single pole, 6-32 Amps (`C’ series ) having short circuit rating 10 KA, 240 volt complete all as specified and directed.
M&L for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel wire 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
Supply laying and testing of cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 4 core complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. including removing of cable, protection covers/ bricks complete all as specified and directed Note : (i) Excavation shall be made carefully in order to avoid damage of existing cables and protection cover/Bricks . (ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations
Material & labour for sand filling with clean dry find sand unwashed including gently punning around under ground cables in trenches/ducts for cable protection with layers of sand ( 8 cm deep before laying cable and 15 cm after laying cable ) complete all as specified and directed at site.
Supplying and laying reinforced precast concrete cable cover, Class LV, type 1, flat, size 250 mm x 150 mm x 40 mm for cable protection complete all as specified and directed.
Returning, filling in excavated soil including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and directed .
Removal of surplus excavated soils to a distance not exceeding 50 M and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M/S OMKAR SINGH YADAV
deva engineers
SahaDevSingh Constructions
saroj constructions
M/S Chadha Brothers
abha enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .