Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
12 Sept 2026, 6:00 pm
Sh Dharmendra Kumar Baitha
GE (AF) Pathankot
REPAIR MAINT OF PERIMETER HANGER SECURITY LIGHT ANDOTHER MISC WORK IN WSA AND TECHNICAL AREA AT AFS PATHANKOT
2026_MES_785986_1
GE/PAF-77/2026-27
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Pathankot
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Pathankot
₹98,000
Yes
22 Aug 2026
22 Aug 2026
14 Sept 2026
22 Aug 2026
12 Sept 2026
5 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down the Carefully unserviceable any type security lights /Hanger light/wall lights of any capaciy/size from pole/ bldgs/ walls light and refixing after repair unsv items such as choke/lamps/ignitors/ Surge protection, drivers complete all, as specified and directed by Engineer in Charge. Note:- (i) After completion of contract, contractor shall hand over all the security/perimeter lights conventional type" in perfect running/functioning condition to the department.(ii) Contractor shall provide his authorised Cell/mobile No. and local address to contact and communicate the message for any break down and contractor's rep will visit the office twice a day (0930 Hrs and 1430 Hrs) to collect the day to day complaints of any nature/type. (iii) Penalty for not rectifying the defect in time(within 72 hrs)will be charged to contractor and the amount of penalty @ Rs 500/- per complaint will deducted from the due payment of contract.(iv) Complaints will be treated as rectified only after user's "Satisfactory slip "will be produced by contractor to concerned JE E/M.(iv) Cost of attending day by day complaint is included in the rate quoted under this item, no extra payment for attending complaint shall be made.(v) Old material obtained from spares replaced under this item shall be contractor's property and will be measured as per credit schedule.(vi) Cost of minor spares i.e, wirnig inside light fittng, connecting wire upto terminal box, nut bolts washers or accessories as required for fixing light on pole, connector blocks are deemed to be included in the item rate, items other than mentioned will be measured and paid seperately under respective item of work,(vii) Cost of T&P i.e, ladders, tools, brazing, welding, soldering required and transportation is deemed to be included in quoted rates(viii) Area cleaning if required within vicininty of lighing poles is to be done by contractor only and rate for area cleaning is deemed to be included in quoted rates . (X) Contractor will be take proper shutdown before repaire with communation of IPSS team / Security section for repair of perimeter lights. | 180 | Each Day Job | - | - |
| 3 | Supply for repair/replacement of LED outdoor driver for 70 to 75 W LED light | 220 | Each | - | - |
| 4 | Supply for repair/replacement of driver for 90 W LED flood/ street light | 150 | Each | - | - |
| 5 | Supply for repair/replacement of LED outdoor driver for 120 to150 W LED flood light | 90 | Each | - | - |
| 6 | Supply for repair/replacement of voltage surge protection device for LED lights of wattage upto 75 W | 90 | Each | - | - |
| 7 | Supply for repair/replacement of voltage surge protection device for LED lights of wattage 75W to 150 W | 80 | Each | - | - |
| 8 | Supply for repair/replacement of street lights cable PVC insulated flexible copper conductor cable of size 2.5 Sqmm three core cut to pieces all as required, drawn into existing conduit/GI pipe of wall or pole as per direction given by Engg-in-Charge. | 1,200 | RM | - | - |
| 9 | Supply for repair/replacement of Timer Switch multifunctional digital Astronomical Rex3 D-21 conf to Cat Pt No 412654 of Legrand or equivalent of make L&T/GE including connecting electrically using copper conductor cable of appropriate size | 8 | Each | - | - |
| 10 | Supply for repair/replacement of air break contactor 3 pole 415 volts 50 Hz AC-3 duty, current rating 50 amps (normal life) with operating coil voltage 230 volts | 5 | Each | - | - |
| 11 | Supply for repair/replacement of air break contactor 3 pole 415 volts 50 Hz AC-3 duty, current rating 70 amps (normal life) with operating coil voltage 230 volts | 4 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
Tender.pdf
Tender Documents • 0.85 MB
BOQ_880774.xls
BOQ • 1.68 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].