Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC SNEH NAGAR COLONY NEAR ABKARI OFFICE SHIVAJI WARD SAGAR MP 47000 | SAGAR | SAGAR | MP | 47000 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹15.2 L+₹49,690 (3.38%)Rejected-Finance BUNGLOW NO 1 RAJPOOT VILLA BARARU ROAD PATKUYI BARARU SAGAR MP 470002 | SAGAR | SAGAR | MADHYA PRADESH | 470002 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹17.4 L+₹2.7 L (18.2%)Rejected-Finance 28 AVANTIBAI MARKET MAKRONIA SAUGOR MP 470004 | SAUGOR | SAGAR | MP | 470004 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹17.5 L+₹2.8 L (19.1%)Rejected-Finance M 78 GARU HARKISHAN NAGAR PASCHIM VIHAR NEW DELHI 110087 | NEW DELHI | WEST DELHI | DELHI | 110087 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹19.2 L+₹4.5 L (30.6%)Rejected-Finance | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
1 Apr 2025, 6:00 pmClosed
GARRISON ENGINEER SAUGOR
Military Engineer services Garrison Engineer Saugor MP- 470001
REPAIR AND REPLACEMENT OF APFC PANELS, LT PANEL, POLES, MCCB AND MISC ALLIED WORKS UNDER GE SAUGOR
2025_MES_700249_1
GE/SGR/TOK-69 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Saugor
Class E category b (i) and as per tender documents
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER SAGAR
₹50,000
Yes
8 May 2025
5 Mar 2025
3 Apr 2025
5 Mar 2025
1 Apr 2025
20 Mar 2025
6 Mar 2025 - 14 Mar 2025
Amount
M & L for steel tubular swaged pole 410 SP-31 (9.0 metre long) including CI base plate, finial taper plug, bolts, nuts & screws as per IS 2713 Part -I & II including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer on exposed portion and making strips of width 30 cm upto 1.5 m from the ground level in black and white shade in alternate layer with two coat of synthetic enamel paint over primer on embeded portion/coping of pole and writing pole number, including taking out of old steel pole and making good to match existing area complete all as specified and as directed.
Supply and erection of pre-stressed concrete pole in vertical position 9 meter long 102mm X 172mm at top and 102mm X 279mm at bottom class-10 confirming to IS-1678 and including marking alternate white and black strips 30cm height with two coats of synthetic enamel paint over a coat of primer and writing pole number, including taking out of old PCC pole and making good to match existing area complete all as specified and directed.
Excavation in trenches in soft/ loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and directed.
All as per srl item No 3.00 above but depth exceeding 1.5Mtrs and n,exc 3.00 mtrs complete all as specified and directed.
Returning, filling, including spreeding leveling watering and well ramming in layers not exceeding 25 cm apart complete all as specified and directed.
Removing of surplus excavated soil to distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtrs above the starting point complete all as specified and directed.
M&L for local river sand coushioning with dry and clean sand over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable and filling the sand in cable duct of inside the sub station building complete all as directed. Note:- Punned thickness shall be measured for payment purpose.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size 250mm x 150mm x 40mm complete all as specified and directed.
M & L for plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate in foundation of PCC poles/ struts, etc. including form work complete all as specified and directed.
M & L for plain cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation of stay assy/ pole etc, including form work complete all as specified and directed.
M & L for plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate for coping/plinth of poles, including necessary form work finished even & smooth without using extra cement complete all as specified and directed.
M&L for aluminium conductors steel reinforced (ACSR) conforming to IS : 398 Part-II -1976 for HT/LT over head lines on PCC/ steel/rail poles including Aluminium binding wire of existing size including taking down old ACSR conductor complete all as specified and directed.
Material and labour for GI wire 4mm dia (8 SWG) stretching and fixing on pole for continious earth conductor, Guard wire 3.2 mm (10 SWG) for cradle (Hexagonal/rectangular) including binding wire for LT/HT OH conductor including taking down old GI wire complete all as specified and directed.
Supply and fixing stay assembly complete with accessories shown in electrical plate No 1 with stay rod of 16 mm dia including loop insulator suitable for 1.1 KV (size 65x90 mm) with clearance of hole 16 mm and MS stay plate size 230 x 230 x 6mm, stay clamps etc complete all as specified and directed.
M&L for galvanised stay strand 7/3.15 mm or 7/4.00 mm size with minimum tensile strength of 700 N/ Sqmm and conforming to IS : 2141-1979 complete all as specified and directed.
S&F pin type polymer/porcelain, vitreous, white, brown or green insulator including Galvanised Mild Steel spindle, two Galvanised iron washers and one GI nut 100 mm height , 65 mm dia suitable for 1100 Volt working pressure grade (LT) complete including taking down old insulators complete all as specified and directed.
S&F shackle type polymer/porcelain, vitreous, white, brown or green insulator including Galvanised Mild Steel straps, washers, suitable bolts, washers and nuts of size 100 mm height, 115 mm dia for 1100 volts working pressure grade including taking down old insulators complete all as specified and directed.
S&F in replacement danger notice plate 1.6 mm thick mild steel sheet, viterous enamelled white, with letters , figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for LT of size 20x15 cm complete all as specified and directed.
S&F in replacement danger notice plate 1.6 mm thick mild steel sheet, viterous enamelled white, with letters , figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for HT 11 KV of size 25x20 cm complete all as specified and directed.
S&F in replacement danger notice plate 1.6 mm thick mild steel sheet, viterous enamelled white, with letters , figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for HT 33KV of size 25x20 cm complete all as specified and directed.
Supply only electric hand gloves rubber suitable for 11 KV line complete all as specified and directed.
Supply only electric hand gloves rubber suitable for 33 KV line complete all as specified and directed.
Supply only safety Helmet with slide-strap adjustment yellow complete all as specified and directed.
Supply only telestone type fibre glass discharge rod suitable for 11/33 KV line complete all as specified and directed.
Supply only lineman safety belt for electrician weary at waist level as approved by Engr-in-Charge for working on overhead line/pole complete all as specified and as directed.
M&L for rubber mat of size 1mtrx2mtrx19mm suitable for 11KV sub station complete all as specified and directed.
M&L for rubber mat of size 1mtrx2mtrx10mm suitable for 11KV sub station complete all as specified and directed.
Supply, laying, connecting and testing cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 120 Sqmm 3.5core including taking down old cable of any type/size complete all as specified and directed.
Supply, laying, connecting and testing cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 70 Sqmm 3.5core including taking down old cable of any type/size complete all as specified and directed.
Supply, laying, connecting and testing cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 50 Sqmm 3.5core including taking down old cable of any type/size complete all as specified and directed.
M&L for earthling complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 meters below normal ground level surrounded from all sides by mixture of charcoal & common salt & electrode connected to and including galvanised earth lead 4.0 mm dia as earthling lead by means of bolts, nuts, check-nuts, and washers of galvanised iron and GI protection pipe light grade 15 mm dia connected to earth point , GI pipe light grade 20 mm dia for watering funnel with wire mesh all as specified & indicated in Electric plate no 3 of SSR 2009 part I complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600X600X6 mm thick, burried directly in ground,earth pit not less than 2.25 meter deep below ground level with top edge of earth plate not less than 1.5 meter below ground level, steel earth plate connected with 25x4 mm GI strip by means of bolts, nuts, check nuts and washer of galvanised iron or steel as shown in electrical plate No. 5 connected to earth test point all as described in MES schedule part II including excavation earth work concreate pit with 50 mm thick RCC cover in RCC 1:2:4 type B-I duly reinforced with MS bars 6 mm dia @ 150 C/C both ways and pit chamber in PCC 1:2:4 type B-I with 2 Nos suitable lifting handles of 12 mm MS bar and GI protection pipe of suitable size,and watering pipe 20 mm dia with water funnel test point and extra length up to 7.5 meter connected to Panel board complete all as specified and directed. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
S&F for pipe galvanised iron light grade ( ISI marked )with all fittings laid in trenches or on pole, crossing of road,fixed on wall for protection of cables complete all as specified and directed of 50 mm dia complete all as specified and directed.
S&F for pipe galvanised iron light grade ( ISI marked )with all fittings laid in trenches or on pole, crossing of road,fixed on wall for protection of cables complete all as specified and directed of 80 mm dia complete all as specified and directed.
M&L for cutting of vegetation surrounding transformer, two poles, four pole structure, LT panel at various sub station / E&M installation and remove to a distance not exc 50 mtr complete all as specified and directed.
Taking down of existing panel cover and refixed including fabrication of existing panel cover with new hing, nut and bolt with and including applying two coat of hi-gloss synthetic enamel paint complete all as specified and directed.
S&F in replacement framed work as indoors or gates of angle made out of FE 410-W Gde E-250 quality -A or other section with gusset plates, rails, fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
Supply and fixing in replacement of MCCB 4 pole , 250 amp fixed thermal and fixed magnetic type of rating 35 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed.
Supply and fixing in replacement of MCCB 4 pole , 200 amp fixed thermal and fixed magnetic type of rating 35 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed.
Supply and fixing in replacement of MCCB 4 pole , 160 amp fixed thermal and fixed magnetic type of rating 16 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed.
Supply and fixing in replacement of MCCB 4 pole , 100 amp fixed thermal and fixed magnetic of rating 16 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed.
Supply and fixing in replacement of MCCB 4 pole , 63 amp rating of 16 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed.
S&F in replacement of MCCB 3 pole , 63 amp rating of 16 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed.
M&L for checking of existing APFC panel every month at different location (Barthuma filtration plant, Chittora pump hosue and Rajghat pump house) should be capable of improvement of PF upto 0.99 on the average of monthly consumption in each phase, at the different loads of Pump set and during the off load entire installation in matching with Metering Equipment of MPEB overall the maintaining the PF 0.99 in APFC panel as well as MPEB meter including checking of all internal wiring and connection with relay, contactor, CT etc all as per site requirement of APFC panel complete all as specified and directed. Note :- (i) Checking of all three panels in a particular months to be considered as one unit. (ii) Quoted rates shall be deemed to include minor repairs and opening of panel accessories and taking the defective items to the approved workshop for relay adjustment with reference to variable capacitor acoording to load requirement. (iii) Spare parts if any shall be measured and paid separately under relevant items of BOQ as supply only. (iv) Record of checking of existing APFC panel should be submitted by the contractor duly signed by the Engr-in-Charge in every month.
M&L for checking of Thyristor based APFC panel of any size and any capacity with minimum requirement of material like relay, contactor, CT etc all as per site requirement complete all as specified and directed. Note :- (i) Quoted rates shall be deemed to include opening of panel accessories and taking the defective items to the approved workshop for relay adjustment with reference to variable capactior acoording to load requirement, entire APFC panel should be capable of capable of improvement of PF upto 0.995 on the average of monthly consumption, at the different loads of Pump set and during the off load entire installation even at No Load. (ii) Spare parts if any shall be measured and paid separately under relevant items of BOQ as supply only.
M&L for checking of APFC panel of any size and any capacity with minimum requirement of material like relay, contactor, CT etc all as per site requirement complete all as specified and directed. Note :- (i) Quoted rates shall be deemed to include opening of panel accessories and taking the defective items to the approved workshop for relay adjustment with reference to variable capactior acoording to load requirement, entire APFC panel should be capable of capable of improvement of PF upto 0.995 on the average of monthly consumption, at the different loads of Pump set and during the off load entire installation even at No Load. (ii) Spare parts if any shall be measured and paid separately under relevant items of BOQ as supply only.
Supply only contactor duty contactors type MO C 25 with add on accessories suitable for capacitor bank of existing APFC panel including thimbles connection complete all as specified and directed.
Supply only contactor duty contactors type MO C 20 with add on accessories suitable for capacitor bank of existing APFC panel including thimbles connection complete all as specified and directed.
Supply only contactor duty contactors type MO C 15 with add on accessories suitable for capacitor bank of existing APFC panel including thimbles connection complete all as specified and directed.
Supply only contactor duty contactors type MO C 12.5 with add on accessories suitable for capacitor bank of existing APFC panel including thimbles connection complete all as specified and directed.
Supply, fixing, connecting and testing for replacement of power factor relay RM-12/NAAC 3P12 for APFC panel of any size and any capacity including adjusting and setting up the power factor till 0.99 complete all as specified and directed.
Supply, fixing, connecting and testing for replacement of power factor relay RM-8/NAAC 3P8 for APFC panel of any size and any capacity including adjusting and setting up the power factor till 0.99 complete all as specified and directed.
Supply only MCB three pole 63 Amp 240 Volts 'C' series 10 KA complete all as specified and directed.
Supply only heavy duty capacitor cylindrical/box type 1 KVAR, 440V suitable for existing capacitor bank at site complete all as specified and directed.
Supply only heavy duty capacitor cylindrical/box type 2 KVAR, 440V suitable for existing capacitor bank at site complete all as specified and directed.
Supply only heavy duty capacitor cylindrical/box type 3 KVAR, 440V suitable for existing capacitor bank at site complete all as specified and directed.
Supply only heavy duty capacitor cylindrical/box type 4 KVAR, 440V suitable for existing capacitor bank at site complete all as specified and directed.
Supply only heavy duty capacitor cylindrical/box type 10 KVAR, 440V suitable for existing capacitor bank at site complete all as specified and directed.
Supply only heavy duty capacitor cylindrical/box type 12.5 KVAR, 440V suitable for existing capacitor bank at site complete all as specified and directed.
Supply only heavy duty capacitor cylindrical/box type 15 KVAR, 440V suitable for existing capacitor bank at site complete all as specified and directed.
Supply only heavy duty capacitor cylindrical/box type 20 KVAR, 440V suitable for existing capacitor bank at site complete all as specified and directed.
Supply only heavy duty capacitor cylindrical/box type 25 KVAR, 440V suitable for existing capacitor bank at site complete all as specified and directed.
S&F in repairs flat cable flexible copper of size 2.5 sqmm 3 core, 1100 volt grading complete all as specified and directed.
S&F in replacement of MS Chequered plate of 5 mm thick or over in thickness in available of Fe - 290 Gde E165 and fixed in substation building including painting with black colour over one coat of red oxide primeover and making provision for lifting the plate from duct complete all as specified and directed.
M&L for repalcement of Cross arms,Bracings,Supports,Clamps and back Plates fabricated from structural steel Sections including Nuts, bolts, Washers, Welding nuts, bolts, washers welding bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of Synthetic enamel paint complete all as specified and directed.
dipangashu barick and associates (BID ID -3274954)
SHRI RAM ELECTRICALS ENTERPRISES (BID ID -3274400)
SALUJA CONSTRUCTION CO (BID ID -3270384)
M/S Sai supplier (BID ID -3275059)
S.R ENGINEER WORKS (BID ID -3275152)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .