Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.2 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹11.7 L+₹53,475.50 (4.79%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹12.6 L+₹1.4 L (12.9%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹12.6 L+₹1.5 L (13.1%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹12.5 L
EMD Value
₹24,920
Closing Date
9 Feb 2023, 6:00 pmClosed
AGE (I) AIR FORCE STATION AMRITSAR
ASST. GARRISON ENGINEER (I) AIR FORCE STATION AMRITSAR -143001
RENOVATION AND UP-GRADATION OF OPS ROOM AND OTHER MISC BUILDING AT AIR FORCE STATION AMRITSAR
2023_MES_577181_1
AGE (I) AF/ASR/T-20/2022-23
Open Tender
Civil Works
Item Wise
120 days
AGE (I) AIR FORCE STATION AMRITSAR
Class E and category a(i) and b(i)
8 documents required · 8 mandatory
₹500
Yes
AGE (I) AIR FORCE STATION AMRITSAR
₹24,920
Yes
15 Mar 2023
25 Jan 2023
11 Feb 2023
25 Jan 2023
9 Feb 2023
27 Jan 2023
Amount
M&L 15mm thick cement plastering in cm 1:6 on brick or concrete surfaces other than fair surface, finished the surfaces even and smooth without using extra cement and applying two coats of oil bound distemper over a coat of primer on plastered surfaces including taking down complete all as spd
M&L 5mm thick cement plastering on ceiling in CM 1:3 and applying three coats of white wash plastered surfaces including taking down complete all as spd
M&L 15mm thick cement plastering on fair faces in cm 1:4 on brick or concrete surfaces fair finished the surfaces even and smooth without using extra cement but with using water proofing compound including taking down Complete all as spc upto height 12 mtr . Note : WPC shall be measured and paid separately.
M&L preparation of new plaster surface and applying two coats of cement base paint all as spd upto height 12 mtr.
Demolition of brick work built in cement mortar incl all quoins, arches, pillars etc complete all as specified and directed .
M&L Brick work with sub class "B" bricks, straight or curved on plan exc 6 m mean radius , built in CM 1:4 complete all as specified and directed .
M&L 15mm thick cement plastering in cm 1:6 on brick or concrete surfaces other than fair surface, finished the surfaces even and smooth without using extra cement and applying two coats of oil bound distemper over a coat of primer on plastered surfaces complete all as spd
S&F Anodised aluminium frames for doors ,window ,ventilators, partition with one or more rebates inclding jointing cleat for fixing ect complete all as specified with powder coating complete all as specified and directed
S&F Anodised aluminium door sutter , alumn. Section weighting 0.55 Kg /m including clips ,rubber neoprene packing ,handles 2 Nos in each door ,hinges anodised alumn. snap beading screw etc complete all as specified with powder coating complete
S&F Sheet glass 4.8mm thick ordinary quality, in squares, exceeding 0.50 sqm in each pane including oil putty complete all as specified and directed
S&F Mild steel Mortice lock, vertical type size 100mm 2 level .complete all as specified and directed
S&F in repairs door closer hydraulicaly regulated, aluminium(Die cast ) body Designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed
S&F Joist, channel, angle or tee section, fixed independently, without connecting plates, etc, (out to ordinary lengths i.e within 20 mm of length indicated ) Fe-410 W (Gde E-250 Qlty B). All as specified and directed
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
M&L for two coat synthetic enamel paint over a coat red oxide primer on new steel surface of any description over 10 cm width or girth not otherwise described including prepratio of surface complete all as specified and directed
S&F pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet of thickness 0.5mm thick in roofcovering/wall cladding, fixed withself tapping screws/fastners as per manufacturers instruction complete all as specified and directed
Roughing/ brushing the surface of old concrete/cement floor picking sweeping clean and washing down with water to remove dust/mud etc Supply and Application of 3 Layer SHR Waterproofing Coating System on non-leaking concrete surface by thorough surface preparation followed by one absorption coat of Thermacool WP 51, nano-tech modified, UV resistant elastomeric clear coat having min. 50% solids, then overcoating with 2 Coats of Thermacool 0.3C pure acrylic based, UV resistant, non-yellowing, bio-organism resistant (anti-fungal, anti-bacterial) Solar IR Heat Reflective coating conforming to BIS STD IS 17218:2019 with Pull off Adhesion 2.8 Mpa, passes 2000 hrs accelerated durability test, suitable for all types of cementitious surfaces, white colour, matt, surface coverage 3.25 sqm/Ltr/2 coat, DFT 100 - 120 microns using brush, roller, airless spray gun as applicable incl M&L Screed bed or bedding layer of mortar over brick tile 15 mm thick screed bed in cm 1:4 for laying floor finishes complete as per manufacture's instruction complete all as specified and directed by Engr-in-charge (Note:-The work should be executed through the auth applicator after approval from Engg-in-charge)
M&L for Cement concrete 1:2:4 type B-0 using 12.50mm graded stone aggregate as in roof padding but with using water proofing compound complete all as specified. Note : WPC shall be measured and paid separately.
Supply only integral water proofing compound
M&L for PCC 1:2:4 type B1 (using 20mm graded stone agg) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
Demolition Stone slabs and tiles of any description or thickness in floors, aprons etc.
M & L for Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. complete all as specified and directed and approved by Engg-in-charge
S & F 4-6 mm thick PVC hollow profile sheet as in wall pevelling incl all necessary frame work of clolur/ design as approved by Engr-in- Charge.
Providing and fixing in repair 6mm non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screwss (Frame work for ceiling shall be measured and paid separately) complete all as specified.
S&F in repair Hangers 6mm dia GI (upto 1200mm length 0 adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40X3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified.
Dismantling of ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets
Hacking out existing tile and M&L for Virified Ceramic tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tiles exc 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured ,light shade cement to match including 15 mm thick screed bed in CM 1:6 all as specified.
Material and labour in repair for Point wiring for One light point, controlled by one switch 5 Amp one-way complete with 1.5 Sq mm (nominal area) PVC insulated, unsheathed and multi strand copper conductor FRLS cable (ISI marked) drawn into and including in PVC casing & caping (medium quality) and conduit fittings including 1.5 Sq mm PVC insulated unsheathed and multi stranded copper conductor FRLS cable as earth wire to common earth and connecting to earth dolly including MS sunken box covered with 3mm thick bakelite laminated sheet top cover and machine made brass screw and washers etc complete all as specified and directed;-
(a) All as per item No. 1 hereinbefore but wiring for one 3 pin 6 Ampere socket outlet point on the same board, controlled by other switch complete all as specified and directed.
(c) All as per item No. 1 hereinbefore but wiring for one 3 pin socket outlet 6 amps independent board.
Material and labour in repair for Point wiring for one 5 pin socket outlet 16 amps independent board, controlled by one switch 15 Amp one-way complete with 2.5 Sq mm (nominal area) PVC insulated, unsheathed and multi strand copper conductor FRLS cable (ISI marked) drawn into and including in PVC casing & caping (medium quality) and conduit fittings including 2.5 Sq mm PVC insulated unsheathed and multi stranded copper conductor FRLS cable as earth wire to common earth and connecting to earth dolly including MS sunken box covered with 3mm thick bakelite laminated sheet top cover and machine made brass screw and washers etc complete all as specified and directed
S & F of in repair switch piano flush type single pole one-way 6 Ampere complete all as specified and directed.
S & F in repair of switch piano flush type single pole one-way 16 Ampere complete all as specified and directed.
S & F in repair of 6 Ampere socket outlet flush type, multi purpose suitable for 2 and 3 pins (Total 5 Pins) complete all as specified and directed.
S & F in repair of socket outlet two-in-one, 5 pin each suitable for 16 Ampere flush type with shuttered complete all as specified and directed.
M&L for sub main wiring two single core 6 Sqmm(nominal area) multi-strand copper conductor FRLS PVC insulated and unseathed cable drawn in and including non metalic PVC regid conduit medium grade of suitable size with all standerd fittings, concealed including one run of continous PVC insulated stranded copper conductor FRLS cable 6 Sqmm for earth continuty, including taking out and removal of old sub main wiring, complete all as specified and directed. Note:- Rate quoted shall be deemed to include cutting chases for concealed conduit and making good incement mortar(1:4) or PCC (1:2:4)
S & F in repair sheet metal enclosure for DBs (Single door type) when MCBs to be used single pole and neutral 12 ways including blanking plate as required with 200 Amps rated bus bar, 240 volts fixed sunk/flush to the wall or niche complete all as specified and as directed including necessary brick work and plaster to match with the existing surface complete all as specified and directed.
S & F in repair MCB DP, 240 Volts, AC, B curve, 10 KA, 63 Amps (10 KA 'B' rupturing capacity) complete all as specified and as directed
S & F in repair MCB single pole, 240 Volts, AC, B curve, 10 KA, 6 to 32 Amps (10 KA 'B' rupturing capacity) complete all as specified and as directed.
S & F sheet metal enclosure 63 Amp Triple pole and earth encolsure with a three pin and earth plug with socket complete withone triple pole MCB
S & F sheet metal enclosure 32 AmpTriple pole and earth encolsure with a three pin and earth plug with socket complete withone triple pole MCB
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 4 core
S & F automatic Change over timer switch of split type AC 1.5/2 Ton with all fitting and fixture complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrods of size 60cmx60cmx6mm thick burried directly in ground vertically(earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized iron or steel earth wire 4 mm dia by means of bolts nuts check nuts and GI washers of Galvanised iron protected by steel pipe 15mm (light grade) all as shown in elecrrical plate No.3 of SSR Part-I and connecting to earthing test point (earth test point to be provided at 5 mtr distance from earth pit) and testing on completion including necessary excavation and earth work. The rate also include charcoal dust and salt in alternate layers 25 mm dia light grade GI pipe,funnel,wire mesh.concrete 1:3:6 type C-1 for pit and RCC pit cover. PCC pit shall be provided 50 cm away from earth pit and not on the earth pit itself. The extra cost of the water- ing pipe,bends,elbows shall be included in the unit rate.Note : RCC pit cover shall be precast of RCC 1:2:4type B-1 80mm thick reinforced with XPM weighing not less than 4 Kg/Sqm. Complete all as specified and directed by Engr-in-Charge.
Supply and fixing pre-casted RCC earth pit cover for replacing broken/ unserviceable pit cover including cleaning the surronding area (60 x60 60 cm) complete all as specified and directed
Supply and fixing funnel alongwith wire mesh in replacement of missing/ unserviceable item all as specified and directed
Supply & fixing porcelain supporting insulator of existing size / adequate size fixing on wall / roof for insulating and supporting the lightning arrestor strips to protect during lightning.
Material and labour for brazzing (welding) on Copper strip of existing earthing/lightening arrestors including strip cleaning complete at various location all as specified and directed
Material and labour for shifting outdoor / indoor unit split type and window type AC of any capacity from existing position to other location including civil work, copper pipe, PVC pipe and other material requirement at site, complete with making good disturbed surface of wall by providing brickwork, plastering colour so as to match with the colour of existing wall and necessary arrangement for fixing of AC, complete all as specified and directed.
Supply & fixing for fire alarm system including all fitting & wiring of following item complete all as specified and directed.
(a) S&F Photoelectric type Smoke detectors,
(b) S&F Fire alarm panel
(c) S&F Battery 12 volt 7AH
Material and labour for providing chemical earthing of advance system of Copper pipe Chemrode 3 mtrs long 50mm dia and inner strip of copper as earthing electrodesand filled with conducting concrete back fill compounds with the permanent sealings at both the ends. Top of the earth electrode shall be compressed to form an extended lead with 2 holes for connecting the strip/wire to the load. To ensure the moisture content and electrical conductivity, each earthing pit shall be provided with minimum 03 bags of 25 kgs chemical compound. An arrangement for connection of copper cable suitable size from rod to be made with given Terminal point with SS Nut Bolts, provision of polymer chamber with cover, including necessary excavation in any type of soil, returning, filling in, removal of surplus soil, the desired value of resistance should be less than 1 Ohm, Entire work will be executed by OEM, complete all as specified and as directed.
Note : The total amount shall subject to adjustment of Credit for old materials as per Schedule of Credit.
M/S SIMRAN WALIA ENTERPRISES
KABEER CONSTRUCTIONS
M/S BANSAL ENGINEERING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .