| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹12.6 L+₹88,872 (7.58%)Admitted-Finance VILLAGE PO KOTHI TEH KALPA DISTT KINNAUR HP 172107 | KINNAUR | HIMACHAL PRADESH | 172107 | L2 | Admitted-Finance | |
| 3 | L3₹14.4 L+₹2.7 L (22.7%)Admitted-Finance H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L3 | Admitted-Finance | |
| 4 | L4₹16.7 L+₹5.0 L (42.4%)Admitted-Finance | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S Gopal Singh L2 | RR Jain Associates L4 | R B TRADERS L3 | JAMDAGNI ENGG WORKS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr in depth in soft/loose soil for laying underground cables / erection of steel tubular poles / stay pit etc all as specified and directed by Engineer - in - Charge. | 110 | Cum | 350 ₹38,500 | 398 ₹43,780 | 250 ₹27,500 Lowest | 451 ₹49,610 |
| 2.00 | Returning and filling in two parts (i) using riddled soil obtained from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil complete all as specified and directed.
Note- Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS - 1255-1983 and refilling in trenches as in cable cushioning. | 105 | Cum | 90 ₹9,450 | 148 ₹15,540 | 50 ₹5,250 Lowest | 151 ₹15,855 |
| 3.00 | Removing excavated surplus material to a distance n exc 50m and depositing where directed at level n. exc 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge. | 5 | Cum | 70 ₹350 Lowest | 198 ₹990 | 100 ₹500 | 251 ₹1,255 |
| 4.00 | M&L for laying dry bricks old size with subclass 'B' made of burnt clay best quality locally available with permissible tolerance, laid straight trench for protection of cable all as specified and directed | 7 | Per 1000 | 12,500 ₹87,500 | 11,800 ₹82,600 Lowest | 15,000 ₹1,05,000 | 12,551 ₹87,857 |
| 5.00 | M&L for Cleaning and preparation of surface of MS Tubular pole 9.00 Mtr long and applying, Painting of two coat with aluminium paint over a coat of red oxide primer on MS tubular pole 9 Mtr long. Writing of Pole Nos on 1.5 mtr height from coping of pole, with synthetic enamel paints in 25 CM height complete all as specified & directed by Engr-in-Charge. | 100 | Nos | 600 ₹60,000 | 998 ₹99,800 | 500 ₹50,000 Lowest | 551 ₹55,100 |
| 6.00 | Dismatiling, Taking out, Supplying, laying, jointing & testing cable XLPE insulated in repair, IS 7098 (Part-I)-1988, marked, screened, PVC sheathed armoured electric power cable ( heavy duty) with aluminium conductor for working voltage upto and including 1100 Volts of croos sectional area 10 Sqmm 2 core with aluminium stranded, laid in trenches / fixed on pole / wall / passed through pipe complete with jointing material of LT Cable all as specified and directed by Engineer - in - Charge, Make : Havells / Polycab / Plaza / KEI / GLOSTER. Note :- Road cutting involved any to be filled with PCC and PCC to be measured separately. | 200 | RM | 165 ₹33,000 | 218 ₹43,600 | 210 ₹42,000 | 111 ₹22,200 Lowest |
| 7.00 | All as per item no 06 above but size 16 sqmm 4 core | 100 | RM | 250 ₹25,000 | 318 ₹31,800 | 300 ₹30,000 | 151 ₹15,100 Lowest |
| 8.00 | All as per item no 06 above but size 25 sqmm 3.5 core | 100 | RM | 328 ₹32,800 | 418 ₹41,800 | 400 ₹40,000 | 211 ₹21,100 Lowest |
| 9.00 | All as per item no 06 above but size 35 sqmm 3.5 core | 100 | RM | 372 ₹37,200 | 518 ₹51,800 | 470 ₹47,000 | 231 ₹23,100 Lowest |
| 10.00 | All as per item no 06 above but size 50 sqmm 3.5 core | 150 | RM | 505 ₹75,750 | 718 ₹1,07,700 | 600 ₹90,000 | 311 ₹46,650 Lowest |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
19 Oct 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 863 EWS, PIN-913863, c/o 56 APO
GE 863 EWS, c/o 56 APO
REPAIR / MAINTENANCE TO EXTERNAL ELECTRIC SYSTEM, LT PANELS AND OTHER CONNECTED WORKS AT SUMDO UNDER AGE E/M (WE) IN GE 863 EWS
2026_MES_790391_1
GE/863/EWS-T-80 OF 2026-27
Open Tender
Civil Works
Works
180 days
Sumdo
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 863 EWS
₹28,000
Yes
5 Nov 2026
22 Sept 2026
26 Oct 2026
22 Sept 2026
19 Oct 2026
6 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr in depth in soft/loose soil for laying underground cables / erection of steel tubular poles / stay pit etc all as specified and directed by Engineer - in - Charge. | 110 | Cum | - | - |
| 2 | Returning and filling in two parts (i) using riddled soil obtained from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil complete all as specified and directed.
Note- Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS - 1255-1983 and refilling in trenches as in cable cushioning. | 105 | Cum | - | - |
| 3 | Removing excavated surplus material to a distance n exc 50m and depositing where directed at level n. exc 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge. | 5 | Cum | - | - |
| 4 | M&L for laying dry bricks old size with subclass 'B' made of burnt clay best quality locally available with permissible tolerance, laid straight trench for protection of cable all as specified and directed | 7 | Per 1000 | - | - |
| 5 | M&L for Cleaning and preparation of surface of MS Tubular pole 9.00 Mtr long and applying, Painting of two coat with aluminium paint over a coat of red oxide primer on MS tubular pole 9 Mtr long. Writing of Pole Nos on 1.5 mtr height from coping of pole, with synthetic enamel paints in 25 CM height complete all as specified & directed by Engr-in-Charge. | 100 | Nos | - | - |
| 6 | Dismatiling, Taking out, Supplying, laying, jointing & testing cable XLPE insulated in repair, IS 7098 (Part-I)-1988, marked, screened, PVC sheathed armoured electric power cable ( heavy duty) with aluminium conductor for working voltage upto and including 1100 Volts of croos sectional area 10 Sqmm 2 core with aluminium stranded, laid in trenches / fixed on pole / wall / passed through pipe complete with jointing material of LT Cable all as specified and directed by Engineer - in - Charge, Make : Havells / Polycab / Plaza / KEI / GLOSTER. Note :- Road cutting involved any to be filled with PCC and PCC to be measured separately. | 200 | RM | - | - |
| 7 | All as per item no 06 above but size 16 sqmm 4 core | 100 | RM | - | - |
| 8 | All as per item no 06 above but size 25 sqmm 3.5 core | 100 | RM | - | - |
| 9 | All as per item no 06 above but size 35 sqmm 3.5 core | 100 | RM | - | - |
| 10 | All as per item no 06 above but size 50 sqmm 3.5 core | 150 | RM | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
TD80.pdf
Tender Documents • 2.20 MB
BOQ_886341.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .