Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 CrAccepted-AOC | ₹8.9 Cr Quoted ₹9.2 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹10.6 Cr+₹1.3 Cr (14.3%)Rejected-Finance 17 SADAR BAZAR JHANSI 284001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | ₹10.6 Cr+₹1.3 Cr (14.3%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹12.0 Cr+₹2.7 Cr (29.6%)Rejected-Finance | ₹12.0 Cr+₹2.7 Cr (29.6%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹12.6 Cr+₹3.4 Cr (36.3%)Rejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹12.6 Cr+₹3.4 Cr (36.3%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹13.6 Cr+₹4.3 Cr (46.9%)Rejected-Finance 200 C P COLONY MORAR GWALIOR M P 474006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | ₹13.6 Cr+₹4.3 Cr (46.9%) | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹10.0 L
Closing Date
27 Nov 2020, 6:00 pmClosed
Chief Engineer , Bhopal Zone, Bhopal
HQ , Chief Engineer , Bhopal Zone, Bhopal
ADDITION / ALTERATION AND SPECIAL REPAIR TO SELECTED JCOS/ORS MD ACCN AT JHANSI
2020_MES_359955_2
CEBZ/ JHA /TOKEN / 06 OF 2020-2021
Open Tender
Civil Works
Item Rate
540 days
Jhansi
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,000
GE Jhansi
₹10.0 L
Yes
4 Feb 2021
4 Nov 2020
30 Nov 2020
4 Nov 2020
27 Nov 2020
14 Nov 2020
Amount
Note: (i) Please refer schedule 'A' notes before quoting the tender. (ii) Amount of Schedule of credit shall be deducted off line by the department.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc.complete all as specified and directed.
Demolition of cement concrete in ground floor including terrazo flooring and paving n exc 15cm thickness (below or above the ground level) built in cement mortar.complete all as specified and directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
Demolition of brick work or stone/ boulder Masonry, built in cement mortar including all quoins, pillars etc., complete all as specified and directed.
Taking down eaves gutter and rain water pipes including all fittings any size and pattern ,complete all as specified and directed.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for Refixing or removal to store, complete all as specified and directed.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for Refixing or removal to store,complete all as specified and directed.
Taking down Chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sq. M each (Without taking off shutters from the frame), complete all as specified and directed.
Taking down Chowkats or frames Not exceeding 1.5 Sqm each (Without taking off shutters from the frame), complete all as specified and directed.
Taking down shutters of any description exc 1.0 Sqm but not exceeding 2.00 Sqm each, complete all as specified and directed.
Demolition of RCC Not exc 15cm thickness Roofs, floors (other than ground floors), beams staircases, landing, chajjas, Cover slab and similar suspended work, complete all as specified and directed.
Demolition of cement concrete of any description and in any position of WC’s/Bathroom etc in sunken portion area in and above ground floor, removing demolished material completely and old waste pipe from sunken portion and cleaning the side/bottom surface of sunken floor with wire brush, complete all as specified and directed.
Removing existing water proofing treatment by brushing with wire brush, cleaning of terracing by taking down cement concrete, existing plaster lime cova 80 to 100mm thick mud phuska/cement concrete/lime concrete etc, cleaning of all foreign material such as fungus mass dust etc, roughing surface of corner to roof by wire brush, complete all as specified and directed.
Dismantling for Stone slabs and tiles of any description or thickness in floors, aprons etc, laid dry and pointed in any mortar, complete all as specified and directed.
Dismantling water tank and removing to store exc. 250 litres & not exc. 500 litres capacity of tanks, complete all as specified and directed.
Dismantling of wall / ceiling boards of any thickness including cover fillets etc, complete all as specified and directed.
Dismantling Asbestos Cement Corrugated or Semicorrugate in Roof covering, complete all as specified and directed.
Dismantling of Framed timber scantling 40 sqcm and over in section in any position, complete all as specified and directed.
Dismantling of Framed timber fillet, rails, post, rafters, purlin etc n. exc 40sq cm in section in any position complete all as specified and directed.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for pipe line or for manholes not exceeding 10 Sqm on plan and not exceeding 1.5m in depth in any type of soil And getting out , complete all as specified and directed.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil , complete all as specified and directed.
Removal of excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 m above the starting point , complete all as specified and directed.
M&L Concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 150mm dia (bore) pipe all as specified in cement concrete 1:3:6 type C-2 (Nominal mix) using 40 mm graded crushed stone aggregate, , complete all as specified and directed.
M&L Salt glazed stoneware (SGSW) drain pipes 150 mm bore laid and jointed on concrete bed, complete including testing etc. , complete all as specified and directed.(Concrete bed shall be measured and paid for separately).
M&L Cement concrete 1:4:8, type D-2 (Nominal mix) using 40 mm graded crushed stone aggregates in foundation filling and mass concrete , complete all as specified and directed.
M&L for Precast cement concrete type B-1, 1:2:4 (Nominal mix) using 20 mm grade crushed stone aggregate, as in cover slabs (for manhole etc.) casted at site and setting in cement mortar 1:4 , complete all as specified and directed.
Cutting into existing manholes for connecting new drains,internal dia of pipe150 mm, making good to pipes and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required , complete all as specified and directed.
M&L Brick work with sub class 'B' bricks, old size bricks having crushing strength not less than 75 Kg/Sqcm, straight or curved on plan exceeding 6m mean radius with old size bricks built in cement mortar 1:6, to be below ground level, complete all as specified and directed.
Description all as per item No 29.00 above but except bricks (old bricks as retrieved from demolition as per item no 5.00 shall be reused).
M&L for Brick work with fly ash lime bricks (FALB),old size bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 to be above GL , complete all as specified and directed.
M&L for Brick work with fly ash lime bricks(FALB) confirming to IS 12894 ,old size bricks , straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4, complete all as specified and directed.
Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished fair & even, complete all as specified and as directed.
Rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces in two layers(first coat 10 mm & second coat of 5 mm ) mixed with WPC @ 150ml in 50Kg of Cement by weight , finished even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound shall be measured & paid separately under respective item only
Rendering 10 mm thick on fair faces of concrete surfaces in ceilings in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and as directed..
Rendering 10 mm thick on fair faces of brick work or concrete surfaces of manholes etc. in cement mortar 1:4 mixed with water proofing compound WPC @ 150ml in 50Kg of Cement by weight , finished fair & even , complete all as specified and as directed.Note: Note: Water proofing compound shall be measured & paid separately under respective item only
Supply only integral liquid water proofing compound, mixed in CM as per manufacturer instruction, , complete all as specified and directed.
Preparing newly plastered surfaces of new wall and applying two coats of weather proof exterior grade emulsion over and including a coat of exterior grade cement based primer complete all as specified and directed.
Preparing newly plastered surfaces of wall and applying two coats of oil bound distemper, over a coat of cement base primer over a coat of wall care putty preparing to make the surface to be plain and smooth before primer complete all as specified and directed.
Preparing newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
Preparing newly plastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed.
Complete removal of exisiting treatment, washing and rubbing of old treatment and applying three coats of white wash on wall sufaces complete all as specified and as directed.
Complete removal of exisiting treatment, washing and rubbing of old treatment and applying three coats of white wash on ceiling sufaces complete all as specified and as directed.
Complete removal of exisiting treatment, washing and rubbing of old distempered surfaces and applying two coats of oil bound distemper, over a coat of cement based primer over a coat of wall care putty on plastered surfaces, preparatory to distemering, complete all as specified and directed.
Complete removal of exisiting treatment, washing and rubbing of old surfaces of wall and applying two coats of weather proof exterior grade emulsion over and including a coat of exterior grade cement based primer complete all as sppecified and directed.
Preparation of New or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of red oxide primer, complete all as specified and directed.
Preparation of Old or previously treated steel surfaces of any description, not otherwise described, over 10 cm width or girth and one coat of synthetic enamel paint on old steel surface , complete all as specified and directed.
Preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of pink primer , complete all as specified and directed.
Preparation of Old or previously treated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth andapplying one coat of synthetic enamel paint on old wooden surface , complete all as specified and directed.
M&L for Non-skid cermaic coloured tiles of Size 300X300X7 to 8mm thick, each in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick screed bed in CM 1:6 complete.all as sppecified and directed.
M&L for Coloured Glazed ceramic tiles of size 300x 450 x 7 mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over & including 10mm thick redering in CM 1:4 on wall complete all as specified and directed.
M&L for Jointless Non-skid coloured cermaic tiles 7 to 8mm thick (square/ rectangular) area of each tiles exceeding 0.11 sqm but n.exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6.complete all as specified and directed.
M&L for Jointless Non-skid coloured cermaic tiles 7 to 8mm thick (square/ rectangular) area of each tiles exceeding 0.11 sqm but n.exceeding 0.18 sqm, in skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick backing coat in CM 1:4 on wall complete all as specified and directed.
M&L for machine cut Kota stone slab flooring 20 mm thick and laid over and incl 20 mm thick screed bed in CM (1:6), set and jointed with grey cement slurry mixed with pigment to match the shade of the slab, with and including Cutting ,Griding , mirror Polishing on Kota stone as per local trade practice, complete all as specified and directed.
All as per item here-in-above 54.00 but on vertical surfaces such as skirting/dado over & including 10mm thick rendering in CM 1:4. complete all as specified and directed.
M&L for Green marble 20mm thick and over & including 15mm thick screed bed in CM 1:6 as in steps, pillars, wndow cills, pillars, window cills, cooking platforms and like laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for factory made PU coated, machine pressed precast concrete interlocking paver block of any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with coloured pigment made of PVC moulded (or rubber mould) with vibrating system, with and including 50mm thick sand cushioning, complete all as specified and directed. Note : The cost of sand cushion is included in rate.
M&L for 75mm thick cement concrete type D-2, 1:4:8 (40mm graded aggregate), as in sub base complete all as specified and directed.
M&L for 75mm PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in plinth protection and path laid in alternate panels not more than 2 mtr in length, laid to slope 1:30 finished even and smooth without using extra cement including forming joints 10 mm wide and upto full depth of PCC and filled with bitumen mastic (1:3) 1 part bitumen 85/25 and 3 parts of sand complete all as specified and directed. Note:-Bitumen mastic will measured and paid seperately under ser item No 60.00 here in below.
M&L for grade A forming construction joint 10 mm wide & upto full depth of PCC or plinth protection and filled with bitumen mastic 1:3 ie one part of bitumen 85/25 and three parts of sand complete all as specified and directed.
S&F in repair Aluminium Hat and coat hooks, solid body, 175mm to 250 mm complete all as specified and directed
S&F of rotational moulded polyethylene cylindrical vertical with closed top water storage tank triple layered WHITE COLOUR 500 Ltr capacity with connecting nipple, hoisted and fixed in position on new or existing foundation and making GI tubing inlet or outlet connection, complete all as specified and directed.
S&F in replacement of 20 mm dia of Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (minium weight 20 mm-210 gms) etc, , complete all as specified and directed.
S & F in repairs 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S & F 15 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors , complete all as specified and directed.
S & F 20 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors , complete all as specified and directed.
Description all as per ser item no 65.00 above but fixing only. Note :- Old pipes as retrieved from taking down under ser item No 7.00 here in before shall be reused.
Description all as per item no 66.00 above but fixing only. Note :- Old pipes as retrieved from taking down under ser item No 8.00 here in before shall be reused.
M&L for cutting chases,pinning in brick walls for concealed water tubing n.exc 10cm girth and making good facing where required and pointing in CM 1:3 , complete all as specified and directed.
S&F in repair Vitreous China wash basin, white, flat back, size 550x400mm excluding taps, waste chain and plug and porcelain stopper but including brackets, CP waste copling, 32 mm PVC Waste pipe 600mm long complete all as specified and directed.
Supply & Fix in repairs Vitreous China Squatting pan, 'Orissa' pattern, size 580 x 440 mm white with integral foot rests , complete all as specified and directed.
Supply and Fix in repairs 10 Litres capacity, PVC, valve less, syphonic action type, Flushing Cistern, low level, white inlet, ball valve, float, chain and pull, and brackets including PTMT PVC connection 600mm long and PVC 32 mm dia flush pipe , complete all as specified and directed.
S & F in repairs 15 mm bore Bib taps, fancy type cast copper alloy,chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule , complete all as specified and directed.
S & F in repairs 15 mm bore Bib taps long body fancy type cast copper alloy,chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule , complete all as specified and directed.
S & F in repairs 15 mm bore stop/angle cock fancy type,chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule , complete all as specified and directed.
S & F in repairs 15 mm bore conceald stop cock fancy type,chromium plated with long shank and cup screwed down, screwed for iron pipe or for brass ferrule , complete all as specified and directed.
S&F in replacement of WHB mixer tap, 15 mm dia, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, complete all specified and directed.
S&F in replacement SS grating of square/round shape, overall size of 150x150mm with hinge type openable jali of 100 mm dia size with and incl fixing with CM to floor/nahani traps etc, complete all as specified and directed.
S&F in replacement of PVC connection 450 x 15mm dia PTMT (PVC), complete all as specified and directed.
S & F in replacement Chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union, complete all as specified and directed.
S&F in replacement SS Towel Rail 600mm Long fixed with and including chromium plated brass screws, complete all as specified and directed.
S&F in replacement of Brass CP connection 15mm dia and 45cm long with 2 Nos brass check nuts with washers for geyser, , complete all as specified and directed.
S&F of PVC shelves Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats , complete all as specified and directed.
S&F of Ringfit PVC (SWR) pipe of 110 mm nominal dia size, wall thickness of 3.5 mm, in any length, single socketed type as per IS : 13592-1992 with latest amendment, having one end of the pipe as plain and other end as self socketed with an integral groove to hold the rubber gasket, with and incl rubber tighten gaskets, ringfit sockets etc, complete pipe duly fixed to wall with PVC clamp complete, complete all as specified and directed.
S&F of PVC (SWR) pipe of 110 mm nominal dia size, wall thickness of 3.5 mm, in any length, single socketed type as per IS : 13592-1992 with latest amendment, having one end of the pipe as plain and other end socketed, duly fixed with cement solvent etc, complete pipe duly laid in trenches or in floors, complete all as specified and directed.
S&F of Ringfit PVC (SWR) pipe of 75 mm nominal dia size, wall thickness of 3.5 mm, in any length, single socketed type as per IS : 13592-1992 with latest amendment, having one end of the pipe as plain and other end as self socketed with an integral groove to hold the rubber gasket, with and incl rubber tighten gaskets, ringfit sockets etc, complete pipe duly fixed to wall with PVC clamp, complete all as specified and directed.
S&F of PVC (SWR) pipe of 75 mm nominal dia size, wall thickness of 3.5 mm, in any length, single socketed type as per IS : 13592-1992 with latest amendment, having one end of the pipe as plain and other end socketed, duly fixed with cement solvent etc, complete pipe duly laid in trenches or in floors, complete all as specified and directed.
S&F 110 mm bore PVC (SWR) bends with access door of any radius, complete all as specified and directed.
S&F 75 mm bore PVC (SWR) bends of any radius, complete all as specified and directed.
S&F 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal, complete all as specified and directed.
S&F 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal, complete all as specified and directed.
S&F PVC (SWR) vent cowl 75mm bore, jointing to waste pipe, complete all as specified and directed.
S&F PVC(SWR) vent cowl 110mm bore, jointing to waste pipe, complete all as specified and directed.
S&F PVC Nahani/ floor trap of 75 mm outlet, jointing to waste pipe, complete all as specified and directed.
M&L for 105x60mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, , complete all as specified and directed.
M&L for 125x60mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, , complete all as specified and directed.
M&L for mild steel framed work section as in cuboard door or gates of angle or other section & GI sheet with gusset plates,rails braces etc of grade Fe-290 (Gde E-165) including all necessary machine wks i.e. cutting, welding, grinding etc, complete all as specified and directed.
M&L for mild steel angles, bars, flats etc, as in supports for hold fasts, pipe clamps, plain angle cleats for securing purlins, stay clamps incl nut & bolts (as required) and similar small articles confirming to Fe-290 Gde E-165, complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-0 (12.5mm graded aggregate) for bed block for fixing of chowkhats, filling in pressed steel door frame, cills ,pre-cast lintel n.exc 1.5mtr, coping, benching Etc complete all as specified and directed.
M&L for factory made, kiln seasoned, chemically pressure treated, 35 mm thick Second class hard wood glazed & skeleton shutter for doors, open rebated & prepared to receive glass, gauge etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, size of members of shutters as specified in SSR Part-I section–8, clause 8.24(a) and conforming to IS-1003 Part-I & II, complete all as specified and directed.
S&F factory made 35 mm thick, flush shutter doors, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as specified and directed.
S&F Solid PVC door frame of size 50mm x 47 mm single side prelam PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with prelam sheet PVC sheet reinforced with MS square tube, supplying & fixing in opening as per specification & drawing complete all as specified in SSR Part-II 2010 section 8, complete all as specified and directed.
S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face, supplying & fixing in frame at site , complete all as specified and directed.
S&F factory made 25mm thick flush shutter for cup board door, solid core construction with block board core and prelamination one face with decorative face veneer with lipping/frame to match and other side prelamination with balancing white, with and incl min 5 mm thick wooden beading fixed all around, complete all as specified and directed.
S&F in repair Block boards 18/19mm thick, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame / MS frame work for cup board shelves, complete all as specified and directed.
S&F Box type steel windows with 80x40x1.25mm RHS frame with side hung shutters (double shutters for glass and gauze) with out sash bars jointed together with and including grills using 12mm square bars @ 10cm C/C Ref TD No CEBZ/TD/14/ 2011 including box type hinges with steel handle and steel peg stay complete with glazing bars dovetailed and welded complete all as specified and as directed.
S&F Box type steel Ventilator with 80x40x1.25mm RHS frame with side hung shutters (double shutters for glass and gauze) with out sash bars jointed together with and including grills using 12mm square bars @ 10cm C/C Ref TD No CEBZ/TD/14/ 2011 including box type hinges with steel handle and steel peg stay complete with glazing bars dovetailed and welded complete all as specified and as directed .
S&F of 100mm butt hinges medium weight cold rolled mild steel ISI marked and fixed with mild steel wood screws or welded to angle frame, complete all as specified and directed.
S&F of 100 mm size butt hinges, extruded aluminum alloy with galvanized mild steel pin type B-21 anodized complete all specified and directed
S&F of 75mm butt hinges medium weight cold rolled mild steel ISI marked and fixed with mild steel wood screws or welded to angle frame, complete all as specified and directed.
S&F of 200 mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed with screws, complete all as specified and directed.
S&F of 150mm long mild steel pressed handles, oval type, stove enamelled black and fixed with screws, complete all as specified and directed.
S&F of 300mm long mild steel, sliding door bolt plate type, stove enamelled black, with bright bolt not less than 12mm dia with and incl minimum of 6 bolts and nuts, complete all as specified and directed.
S&F 200 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F of 150mm long barrel tower bolt aluminum anodized extruded section fixed with cadmium plated screws complete all as specified and directed.
S&F of 100mm long barrel tower bolt aluminum anodized extruded section fixed with cadmium plated screws complete all as specified and directed.
S&F of 150mm aluminum handle cast type anodized complete all specified and directed.
S&F of 100mm aluminum handle cast type anodized complete all specified and directed.
S&F of mild steel ordinary rat tail rod pattern springs of size 300mm including roller and roller plate complete , all as specified and directed
S&F for floor door stopper 140 mm of aluminium alloy body anodised with tongue of rubber bush at one end fixed to door , complete all as specified and directed.
S&F Rubber bush of 25mm long fixed to door , complete all as specified and directed.
S&F 75 mm Hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws , complete all as specified and directed.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc 0.5 Sqm in each pane complete all as specified and directed.
S&F 3mm thick sheet glass frosted/figured and pin headed glazing with oil putty in squares not exc 0.5 Sqm in each pane complete all as specified and directed.
S & F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with tinned tacks or galvanized wire staples complete all as specified and directed
M&Lin repair for Aluminium anodised curtain rod 25mm dia with caps/lobs and wall mounting bracket cutting in to length required at site , complete all as specified and directed.
S & F for stainless steel kitchen plate rack size 750x 600x230 mm including fixing arrangement to walls with rawel plug or wooden plugs complete all as specified and directed.
S&F sinks made of stainless steel 1 mm thick kitchen with CP waste coupling , 40 mm , PVC waste pipe 600 mm long, 40 mm dia including fixing cantilever bracket and connecting union to pipe overall size 495mm x420mm with bowl size 410 mm x 330mm x 160mm , complete all as specified and directed.
M&L for RCC (nominal mix) Type A1 1:1.5:3 (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and directed.
M&L for RCC (nominal mix) Type A1 1:1.5:3 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc, complete all as specified and directed.
M&L for RCC (nominal mix) Type A1 1:1.5:3 (using 20mm graded stone aggregate) as in chajjas, complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
M&L for mild steel TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Description all as per Srl item No 133.00, mentioned here-in-before but mild steel TMT bars of 5mm dia and over upto and incl 10mm dia as in stirrups, spacers and binders , complete all as specified and directed.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exc 200mm thick (Horizontal or sloping), complete all as specified and directed.
Use and waste of form work to soffits of chajjas and similar work including edges complete for rough finished surface, complete all as specified and directed.
Use and waste form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, cantilevers, shelves incl supports, overhangs etc, complete all as specified and directed.
Use and waste of form work to edges of concrete flats, treads, breaks in floor, window cills, concrete railings, openings in concrete walls, floor and roofs not exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide, complete all as specified and directed.
Use and waste of form work to edges of concrete flats, treads, breaks in floor, window cills, concrete railings, openings in concrete walls, floor and roofs not exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 5cm but not exc. 10cm wide, complete all as specified & directed.
M&L for 15mm thick rendering in CM 1:3 on fair faces of brick work or concrete surfaces (to sunken floor & vertical surfaces) mixed with liquid water proofing solution @ 150ml in 50 Kg of Cement by weight, complete all as specified and directed. (Note : Water proofing compound shall be measured & paid separately under respective item only)
M&L water proofing treatment to toilet area of sunken floor complete all as specified and directed by Engr in charge with following course of description below :- (a) Applying first layer of cement slurry @ 0.488Kg/Sqm mixed with acrylic based polymer modified cementation composite compound coating @ 0.253Kg/Sqm of make as approved in technical instruction 5/2003 and be allowed to air cure for 4 Hours. (b) Second layer of cement slurry @ 0.242Kg/Sqm mixed with acrylic based polymer modified cementation composite compound coating @ 0.126Kg/Sqm and be allowed to air cure for 4 Hours. (c) Followed with water curing and testing for leak proof by ponding test for 48 Hours.
M&L for PCC 1:5:10 Type E2 using 40mm graded stone aggregate as in mass filling in two layer in sunken portion, complete all as specified and directed.
M&L for 50mm dia GI pipe as in spout to drain out if any leakage occures in the sunken portion, complete all as specified and directed.
S&F of exposed frame false ceiling system with GI powder coated grid consisting of interlocking arrangement of main T runner of 15mm size, suspended at 1200mm C/C and cross T runner of 15mm size suspended at 600mm C/C supported by 1.5mm dia GI wire from roof/Slab/truss incl wall/perimeter runner/channel of 15 mm size with and incl 4mm thick pre-painted non asbestos fiber reinforced cement board (E-board), designer type of size 595x595mm, duly fixed in ceiling frame work, complete all as specified and directed.
S&F of pre-painted 0.50mm thick Galvalume Aluminium Zinc coating GI based corrugated / semi corrugated / trapezoidal steel sheet of any colour having tensile strength 550 MPa and AZ 150 grade as in roof covering , fixed with self tapping screws, complete all as specified and directed.
S&F pre-painted Galvalume Aluminium Zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength 550 MPa and AZ 150 grade as in ridge of roof covering, fixed with self tapping screws, complete all as specified and directed.
M&L for structural steel, as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, Fe-410-W(Gde-E-250) quality-B, complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate as in padding, levelling to roof/sunken slab and roof kerbs etcwith liquid water proofing solution (mixed @ 150ml in 50 Kg of Cement by weight), finished even and fair with proper slope as prepatory works to water proofing treatment, complete all as specified and directed. Note : Water proofing compound, as required, shall be measured & paid separately under respective item only.
M&L of water proofing treatment to accessible roof slab, with APP based modified polymeric membrane, seven layered with centre core 100 micron HMHDPE, outer film 20 micron each, having thickness 3mm weight not less than 3kg/Sqm as per manufacturer’s instructions with torch application complete all as specified and directed with following course of description below :-
(a) 10 mm thick plaster in CM 1:4 with WPC will be applied over the roof slab when concrete is green. After the plaster is cured the roof will be tested for water tightness by ponding with water for seven days for any seepage is observed the rectification will be carried out by pressure grouting under the pressure of 5kg/sqcm using cement based cement grout. After the surface is repaireds the slab will be tested for water tightness again before proceeding with further treatment.
(b) the surface of roof, parapet and gutters, drain mouths, etc. over which waterproofing treatment is to be applied shall be cleaned of all foreign matter such as, fungus, moss, dust etc by wire brushing and dusting. For cast iron drain out lets a grove shall be cut around to tuck in the treatment. Concrete angle-fillets shall be provided at junctions between roofs and vertical faces of walls (parapet and other walls) around obstacles such as pipes, chimney stacks, etc. and other similar situation to ease up about corners.
(c) Bitumious based primer confiorming to IS: 3384 @ 0.3 kg/SM to be applied on prepared surface, till the surface is property impregnated.
(d) After the application of approved bituminous primer the water proofing membrane shall be laid on the primed surface by torch application method as per manufacturer's instruction. The overlap while toching shall be 100mm in longitudinal direction and 150 mm in transverse direction. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer.
(e) All joints and changes in direction should be curved with cement mortar 1:3 mixed with SBR latex @ 200ml per bag of cement and cured well before laying the membrane.
(f) A fillet of PCC (1:2:4) of type B-1 of size 100mm x 100 mm shall be provided at all junctions of vertical and horizontal surfaces and wherever there is changes direction. The membrane should not be taken over at any steep turns and hence all corners/ juctions should be rounded.
(g) Toping will be done with precast machine pressed cement concrete tiles of size 250x250mm, 20-25mm thick, conforming IS:1237 shall be laid over 15mm thick cement mortar screed in 1:4. The joints between the tiles will be 2-3 mm & will be filled with chemical as specified.
M&L of water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane, seven layered with centre core 100 micron HMHDPE, outer film 20 micron each, having thickness 3mm weight not less than 3kg/Sqm as per manufacturer’s instructions with torch application complete all as specified and directed with following course of description below :-
(a) 10 mm thick plaster in CM 1:4 with WPC will be applied over the roof slab when concrete is green. After the plaster is cured the roof will be tested for water tightness by ponding with water for seven days for any seepage is observed the rectification will be carried out by pressure grouting under the pressure of 5kg/sqcm using cement based cement grout. After the surface is repaireds the slab will be tested for water tightness again before proceeding with further treatment.
(b) the surface of roof, parapet and gutters, drain mouths, etc. over which waterproofing treatment is to be applied shall be cleaned of all foreign matter such as, fungus, moss, dust etc by wire brushing and dusting. For cast iron drain out lets a grove shall be cut around to tuck in the treatment. Concrete angle-fillets shall be provided at junctions between roofs and vertical faces of walls (parapet and other walls) around obstacles such as pipes, chimney stacks, etc. and other similar situation to ease up about corners.
(c) Bitumious based primer confiorming to IS: 3384 @ 0.3 kg/SM to be applied on prepared surface, till the surface is property impregnated.
(d) After the application of approved bituminous primer the water proofing membrane shall be laid on the primed surface by torch application method as per manufacturer's instruction. The overlap while toching shall be 100mm in longitudinal direction and 150 mm in transverse direction. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer.
(e) All joints and changes in direction should be curved with cement mortar 1:3 mixed with SBR latex @ 200ml per bag of cement and cured well before laying the membrane.
(f) Fourth course of Apply a coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance.
M&L for 0.8mm mild steel, plain, black sheet in Chullah hood or duct for exhaust and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. , complete all as specified and directed.
M&L for ATT ,providing and injecting chemical emulsion for Post Constructional along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. , complete all as specified and directed.
M&L for ATT , providing and injecting of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors , complete all as specified and directed.
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations etc , complete all as specified and directed.
Preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, not otherwise described,ends of posts, backs of chowkats, etc. and treated with tar or coal tar black paint , complete all as specified and directed.
Taking down carefully aluminum / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switches, sockets, aluminium conductor cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed.
M&L for Point wiring with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG, 60 mm deep with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass screws for mounting switches, sockets, fan regulator, etc. complete all as specified and directed for the following points :-
(a) One light / exhaust fan / ceiling fan/ bell point controlled by one switch
(b) One 6A socket point controlled by one switch on independent board
(c) One 6A socket point controlled by one switch on same board
Description all as per srl item no.158.00 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for one 16 Amp socket point controlled by one 16 Amp switch on independent board.
M&L for sub main wiring along with earth wire with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc complete all as specified and directed for the following sizes:- (Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length)
2runs x 4 sqmm(Ph & N) + 1run x 4 sqmm(earth wire)
2runs x 6 sqmm(Ph & N) + 1run x 6 sqmm(earth wire)
Notes for item No. 158.00 , 159.00, 160.00 (i) Quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface. (ii) If any beam / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & capping or surface conduit for drawing cables and surface PVC gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) No cutting shall be done on ceiling for laying PVC conduit for ceiling fan point wiring. Surface conduit or PVC casing capping may be used in that portion.
Supply and fix switch piano flush type 6 Amps, one way, 240V, 50Hz complete all as specified and directed.
Supply and fix socket 6 Amps, 2-in-1, 5 pin flush type universal 240V, 50Hz complete all as specified and directed.
Supply and fix switch piano flush type 16 Amps, one way, 240V, 50Hz complete all as specified and directed.
Supply and fix socket 16A & 6A, 2-in-1 flush type universal 240V, 50Hz complete all as specified and directed.
Supply and fix Lamp holder, angle type with metal ring, PVC/Polycarbonate body complete all as specified and directed.
Supply and fix bell push switch flush type 6 Amps, 240V, 50Hz complete all as specified and directed.
Supply and fix call bell ding dong, AC, 240V, 50Hz complete all as specified and directed.
Supply and fix ceiling rose 6 Amps, 3 plate, 240V, 50Hz complete all as specified and directed.
Supply and fix electronic fan regulator rotary type in 5 steps 240V, 50Hz complete all as specified and directed.
S & F 7 W LED lamp, retrofit type suitable for B-22 holder base with polycarbonate diffuser , complete all as specified and directed.
Supply and fix LED batten with CRCA sheet steel box type body pre-wired suitable for and including provision of 1x20/22 Watt (4 feet) retrofit LED tube with PC body, white light of CCT 6000°k, 100 lm / Watt lumens efficacy, and connecting up with twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed. Note : The cost of retrofit type 20 / 22 watt LED tube rod is deemed to be included in the quoted rate.
Supply and fix integrated LED batten 9/10 watt, 2 feet long, white light of CCT 6500°k, 100 lm / Watt lumens efficacy, in engineering plastic batten, acrylic cover with built-in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed by Engineer-in-Charge.
Supply and fix integrated LED bulkhead luminaire 10 Watt with built-in electronic driver, pre-wired white light of CCT 6000°k, 80 lm / Watt lumens efficacy, with & including making all electric connections with three core PVC insulated , PVC sheathed copper conductor flexible cable of 0.5 Sqmm from ceiling rose to connector of light, complete all as specified and directed.
Supply and fix LED street/security light fitting, 36 watt having greater than or equal to 100 lu / watt lumen efficacy, CCT 6000-6500° K of with high efficacy long life LEDs with In-built electronic driver complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including GI pipe bracket made up of 25mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core twisted flexible copper cable of size 0.5 sqmm from ceiling rose to connector of fitting complete all as specified and as directed. Note :- (a) The cost of MS clamps along with fixing accessories i.e. nuts, bolts, & washers etc. is deemed to be included in the quoted rate. (b) Notes for Ser item No 172.00,173.00,174.00,175.00 above : (i) LM-79 & LM-80 test certificates duly certified by NABL laboratories for all LED fixtures shall be submitted by the contractor. (ii) Written guarantee letters for 05 year warranty on contractors letter head alongwith warrant certificate given by the OEM's of LED shall be submitted by the contractor.
Supply and fix modular MCB protected plug and socket board with & incl modular sheet metal flush box of 04 module size 25A rated mini type MCB SPN and 25A rated 3 pin plug, 240 V, 50 Hz complete with & including cutting & chasing on the wall surfaces for flush mounting of socket board and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed. Note :- The cost of modular sheet metal flush box, mini type MCB , plug & socket are deemed to be included in the quoted rate.
Supply, installation & testing of Electric Water Heater storage type, vertical, 25 Liters capacity, 5 Star rated, with heating element, PUF insulation, multifunction safety valve, adjustable knob for temperature setting and vitreous enamelled inner tank conforming to IS -13273 and outer body suitable for operating on 230V, 50 Hz, single phase AC supply with & including mounting on wall with suitable size & No. of anchor bolts complete all as specified and directed.
Supply and fix exhaust fan of 300mm sweep size with 04 Nos of blade leafs, 70 W power consumption, 230 volts AC, 50 HZ, 1300 to1400 RPM, 100 % copper winding heavy duty type double ball bearings complete with & incl self closing pre-painted MS Louvers, mounted in suitable opening arrangement & fixing with 4 Nos 50 mm long MS fasteners, nuts & washers with & including making all electric connections with three core PVC insulated, PVC sheathed copper conductore flexible cable of 0.5 sqmm size from ceiling rose to connector of fan complete all as specified and directed. Make : (a) The cost of making round shape hole / opening in the existing wall & making good the disturbed surface of wall / ceiling etc. as required, is deemed to be included in the quoted rate . (b) The cost of pre-painted MS louvers, MS fasteners, nuts, & washers, etc. are deemed to be included in the quoted rate.
Supply and fix ceiling fan, 1200mm sweep, 3 blade, white colour, energy efficient, 50W / 52W power consumption, 230 volts AC, 370 RPM, 100% copper winding motor, double ball bearing, with and including down rod, canopy (02 Nos), GI fan clamp with rubber bush, GI nuts, bolts and split pins etc (without regulator) with & including making all electric connections with three core PVC insulated, PVC sheathed copper conductore flexible cable of 0.5 sqmm size from ceiling rose to connector of fan complete all as specified and directed.
Taking down ceiling fan of any size carefully, sealing cable end, dismantling blades and carry out complete servicing including supply replacing new bearings / bushings, capacitor incl capacitor holder, terminal connector, canopy , rubber bush, GI nuts, bolts, split pins suitable for any model of existing fan, with & incl cleaing all dust, oil , grease etc. including filling cavities with filler, applying one coat of synthetic enamel spray paint of existing colour, testing complete fan for satisfactory functioning & hanging in its existing or new location with & including making all electric connections with three core PVC insulated, PVC sheathed copper conductore flexible cable of 0.5 sqmm size from ceiling rose to connector of fan complete all as specified and directed. Note : The cost of all spares ,painting & new fixing accessories are deemed to be included in the quoted rates.
Supply and fix MCB distribution board, TPN, 4 way , 415 Volts, made out of sheet steel powder coated enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good of wall surfaces , complete all as specified and directed. Note: MCBs shall be measured and paid separately under respective items only .
Supply and fix MCB distribution board, SPN, 8 way, 230 volts in sheet steel powder coated enclosure, double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting & chasing of wall surfaces for flush mounting of DB and making good of wall surfaces , complete all as specified and directed. Note: MCBs shall be measured and paid separately under respective items only .
Supply and fix MCB distribution board, SPN, 4 way, 230 volts in sheet steel powder coated enclosure, double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting & chasing of wall surfaces for flush mounting of DB and making good of wall surfaces , complete all as specified and directed. Note: MCBs shall be measured and paid separately under respective items only .
Supply and fix MCB 63A, 10 KA, TPN, 'C' curve, 240 V, 50 Hz complete all as specified and directed .
Supply and fix MCB 40A, 10 KA, SPN, 'C' curve, 240 V, 50 Hz complete all as specified and directed .
Supply and fix MCB 6 - 32A, 10 KA, single Pole, 'C' curve, 240 V, 50 Hz complete all as specified and directed .
Supply, laying, testing, commissioning of LT UG cable, XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip & overall PVC sheathed , 16 sq. mm , 4 core size , 1100 voltsgrade confirming to IS: 7098 (Part-I), suitble for earthed system,with & including making connectins on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc, with & including taking down existing unserviceable cable of any size & description complete all as specified and directed. Note: The excavation ,earth work & protection pipe etc. will be measured & paid for separately under respective items.
M&L Double wall corrugated HDPE pipe, ISI marked of outer dia 50 mm , inner dia 38 mm with smooth internal & profiled external surface for cable protection for cable laid in trenches / floors / duct or fixed on walls / pole including all connections , accessories, like socket , couplers, bend etc. complete all as specified and directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m depth for laying of GI Pipe and getting out in any type of soil complete all as specified and directed.
M&L for cutting of existing road / hard standing up to 15 cm depth for laying of cables / pipe and making good the disturbed surfaces by providing PCC 1:2:4 after laying of pipes and returning filling of soil, complete all as specified and directed. Note:- Excavation and earth work below road / hard standing will be measured and paid under relevant items.
M&L for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to GI wire 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth wire up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II.
Supply and fix Hot Press Molded SMC meter box of size not less than 700mm X 480mm X 210mm, double door with transparent glass windows for viewing the meter reading without opening the door, minimum IP-43 degree of protection for indoor use for accommodating 04 Nos X 1 Phase 2 Wire energy meter including cutting the wall surfaces for flush mounting of meter box and making good with cement plaster, putty and paint to match with the existing surface etc as per site requirement complete all as specified and directed .
Garg Trading Co.
m/s meetu enterprises
Mata Builders
ATUL CONSTRUCTION CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .