REPAIR/ MAINT OF DISTRIBUTION TRANSFORMER AND CONNECTED WORK UNDER GE (UTILITY) BATHINDA AT BATHINDA MIL STN
2021_MES_487878_1
CWE BTD 8236/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BATHINDA
AS PER NIT
7 documents required · 7 mandatory
₹500
GE (U) Bathinda
₹80,000
Yes
6 Jan 2022
12 Nov 2021
18 Dec 2021
12 Nov 2021
16 Dec 2021
3 Dec 2021
12 Nov 2021 - 27 Nov 2021
Amount
Disconnecting HT/LT connections of burnt / defective copper / aluminum wound transformer of capacity varying from 25 KVA to 100 KVA, taking down from site of installation, opening up the top cover, draining out transformer oil from transformer in suitable containers (containers to be provided by the contractor ) inspection / assess the defective / burnt parts, core assembly of transformer in the presence of AGE / GE and prepare list and then shifting the transformer to trade / contractor's workshop for repair, cleaning and making good surface and rewinding the same with existing size of new copper / aluminum conductor, strip wound coils, limb for HT / LT , fixing of class 'E' insulation in core assembly etc. including internal cleaning, removing sludge, washing and painting with one coat of zinc chromate paint to inner side of the transformer body and one coat on outer side with synthetic enameled Grey paint (spray painting) after cleaning and removing oil spot from the body and re assembling, reinstalling, commissioning the transformer to its original place and testing at site on full load after connecting the HT / LT connections complete all as specified and directed by Engineer-in-Charge.
All as per srl item No. 1 above but capacity varying from 125 KVA to 200 KVA complete.
All as per srl item No. 1 above but capacity varying from 250 KVA to 315 KVA complete.
All as per srl item No. 1 above but capacity varying from 400 KVA to 630 KVA complete.
Notes for item No. 1.00 to 4.00:- (i) HT/LT copper/aluminum coil, transformer oil and other required parts as mentioned here-in-after shall be measured and paid separately under appropriate item of this BOQ. (ii) The T & P/ vehicles and minor parts/nut bolts etc. will be arranged by the contractor and the cost of same shall be deemed to be included in the quoted rates. (iii) The rates quoted is deemed to be included in the unit rate for cutting/chipping of RCC /PCC / plastering of foundation/ platform and minor grill work/welding work. .
Shifting transformer up to 500 KVA capacity from store yard /site of installation of any description / any position and shifting to other site of installation distance up to 15 kilometer including fixing on 2/4 pole structure or on plinth and connecting with HT/LT side of existing system and testing complete all as specified and directed by Engineer-in-Charge. Note:- The T & P vehicles and minor parts/nut bolts etc. will be arranged by the contractor and the cost deemed to be included in the quoted rates.
Disconnecting HT/LT connections of the pole mounted/plinth mounted outdoor type/indoor type transformer of capacity 25 KVA to 100 KVA, opening up the top cover for checking the conditions to carryout repairs at site, including draining out oil from the transformer in suitable container (containers to be provided by the contractor) and the transformer repair with replacement of parts (as required), check the lead connection from winding to bus rods including necessary soldering/jointing etc. and after complete repair refilling the dehydrated oil and testing on full load after connecting the HT/LT connections complete all as specified and directed by Engineer-in-Charge.
All as per srl item No. 6 above but capacity of transformer from 160 KVA to 200 KVA complete
All as per srl item No. 6 above but capacity of transformer from 250 KVA to 315 KVA complete
All as per srl item No. 6 above but capacity of transformer from 400 KVA to 750 KVA complete all as specified and directed by Engineer-in-Charge.
Notes for item Nos. 6.00 to 9.00:- (i) Major parts (as required) shall be measured and paid separately under appropriate item of this BOQ. (ii) Dehydrated transformer oil shall be measured and paid separately under appropriate item of this BOQ. (iii) The T & P and minor parts/nut bolts etc. shall be arranged by the contractor and the cost of the same shall deemed to be included in the quoted rates.
Taking out the unserviceable breather assembly complete from 100 kVA to 750 KVA transformer indoor/outdoor type and supply & fixing new breather assembly complete filled with fresh blue colored silica gel including connecting with proper rubberized gasket complete all as specified and directed by Engineer-in-Charge.
Supply only new copper LT coils made out of proper size of DPC copper wire/strip super enameled of high quality matching with existing impedances and providing class 'E' insulation suitable for transformer 25 KVA to 630 KVA complete all as specified and directed by Engineer-in-Charge.
Supply only new copper HT coils made out of proper size of DPC copper wire/strip super enameled of high quality matching with existing impedances and providing class 'E' insulation suitable for transformer 25 KVA to 630 KVA complete all as specified and directed by Engineer-in-Charge.
Supply only new double paper covered aluminum strip/wire wound coils for LT winding of the transformer of capacity 25 KVA to 630 KVA with suitable size/gauge so as to match with existing working capacity of the transformer and all as per manufactures design/specifications including providing class 'E' insulation complete all as specified and directed by Engineer-in-Charge.
Supply only new double paper covered aluminum strip/wire wound coils for HT winding of the transformer of capacity 25 KVA to 630 KVA with suitable size/gauge so as to match with existing working capacity of the transformer and all as per manufactures design/specifications including providing class 'E' insulation complete all as specified and directed by Engineer-in-Charge.
Note for item Nos. 11.00 to 14.00:- (i) The rate quoted is deemed to be included in the unit rate for varnishing, sleeving and insulating materials and the Contractors shall not have any claim on this account at a later sage.
S & F new cork sheet gasket 6mm thick & 40mm width superior quality on top cover plate of the transformer capacity 25 KVA to 750 KVA complete all as specified and directed by Engineer-in-Charge.
S & F new silica gel complete all as specified and directed .
S & F in replacement LT bush assembly brass complete with double check nuts, washers and oil seal all accessories with bushing insulators for transformer capacity 25 KVA to 160 KVA complete .
S & F in replacement LT bush assembly brass complete with double check nuts, washers and oil seal all accessories with bushing insulators for transformer capacity 200 KVA to 315 KVA complete.
S & F in replacement LT bush assembly brass complete with double check nuts, washers and oil seal all accessories with bushing insulators for transformer capacity 400 KVA to 750 KVA complete.
S & F in replacement HT bush assembly brass complete with double check nuts, washers and oil seal all accessories with bushing insulators for transformer capacity 25 KVA to 160 KVA complete.
S & F in replacement HT bush assembly brass complete with double check nuts, washers and oil seal all accessories with bushing insulators for transformer capacity 200 KVA to 315 KVA complete.
S & F in replacement HT bush assembly brass complete with double check nuts, washers and oil seal all accessories with bushing insulators for transformer capacity 400 KVA to 750 KVA complete.
Supplying and filling new mineral grade transformer oil EHV type confirming to IS-3357 of 1983 for filling and for topping up in transformer/OCB's duly filtered with filtration plant to obtain high dielectric strength not less than 60 KV (Gap 2.5mm) complete all as specified and directed by Engineer-in-Charge. Note:- (i) Empty barrel will be property of contractor and same will be returned to contractor when barrel will be empty. (ii) Wastage of burnt oil shall be considered as 30% of total oil and 70% qty of total oil shall be considered in schedle of credit.
Dehydration & filtration of transformer oil with portable filtration cum dehydration machine to improve the dielectric strength not less than 40 KV within 1 minute with 2.5 mm gap at site of any installation in cantt area and any capacity / make of transformer installed on pole mounted, indoor/out door plinth mounted. Testing of dielectric strength of dehydrated transformer oil of each transformer will be carried out in the presence of Engineer-in-Charge complete all as specified and directed by Engineer-in-Charge. Note:- (i) Contractor shall ensure no wastage of transformer oil. (ii) Contractor shall ensure that the conservator tanks are full to its level before starting the dehydration.
Cleaning and preparation of old painted surface of transformer ( Exposed external surface only) installed at site of any installation in cantt area capacity 25 KVA to 160 KVA transformer installed on pole mounted , indoor / out door plinth mounted by using course cloth/wire brush and painting with one coat of synthetic enamel grey paint with the help of spray gun including writing the SM No/MES No. on transformer with white paint in the existing style/pattern complete all as specified and directed by Engineer-in-Charge.
All as per srl item No. 26 above but capacity of transformer from 200 KVA to 315 KVA complete.
All as per srl item No. 26 above but capacity of transformer from 400 KVA to 750 KVA complete .
M & L for earthing complete with galvanized iron or steel earth plate electrode of size 60 cm x 60cm x 6.0mm thick buried directly in ground, vertically to a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth of not less than 1.5 mtr below normal ground level surrounded from all sides with alternate layers of charcoal and common salt and connected to GI earth strip 32 x 6 mm thick by means of GI bolts, nuts washers & check nuts and soldering the strip, electrode connected to panel board or on poles or on transformer (including making of test point with GI strip of size 32 x 6 mm) including GI protection pipe 40 mm bore light grade dia for protection of strip upto the extent of 7.5 mtr all as directed, GI pipe light grade 20 mm bore for watering including providing funnel and wire mesh, GI frame with suitably reinforced RCC pit cover, PCC chamber pit with PCC (1:3:6) type C2 using 40 mm graded stone aggregates complete including excavation and earth work in any type of strata , all as specified and shown in electrical plate No 3 of SSR-2009 Part - I, PCC pit shall be provided at least 50 cm away from the earth pit and not just on earth pit including testing on completion and dismantling of old earthing. Note:- The rate quoted by the contractor shall be deemed to be included of earth strip 32x6mm and pit protection pipe 40mm dia light grade up to 7.5 mtr distance. Earth strip beyond 7.5 mtr will be measured and paid separately under relevant items.
M & L for earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/ pipe for loop earthing etc. or any other indicated situation as required by using 32 x 6 mm GI strip complete.
S & F of nominal 2.5mm + 10% thick insulated synthetic Mat conforming to IS 15652:2006 alongwith suitable adhesive/chemibound, Pu resin, water proofing compound and sealing material and similar tape of matching colour and matching design, tapes should be used to maintain aesthetic look of the insulation over the joints and corner as per service recommendation and suitable for Class-B upto 11KV with HT trolley movement all as specified and directed by Engineer-in-Charge.
M & L taking sample of transformer oil from power transformer 12.5 MVA carefully in suitable container of capacity not less than 1 ltr for chemical testing from authorised dealer/ firm. Note:- Rate quoted by contractor deemed to be included for taking sample to testing charges etc.
S & F in replacement HT/LT side cable box, cover plate made out of MS sheet of 14 gauge complete with MS nuts, bolts and washer suitable for indoor/outdoor type transformer capacity 25 KVA to 160 KVA complete all as specified and directed by Engineer-in-Charge.
S & F in replacement HT/LT side cable box, cover plate made out of MS sheet of 14 gauge complete with MS nuts, bolts and washer suitable for indoor/outdoor type transformer capacity 200 KVA to 630 KVA complete all as specified and directed by Engineer-in-Charge.
Surface excavation with labour only for removal of grass/roots cleaning of inside complete area of substation with outside along with fencing upto width 1 meter and complete outer orbit of the station approximate minimum area of each Sub station 100 Sqm in contract period including white wash & repair to transformer plinth and earth pit , panel foundation etc. all as specified & directed by Engr -in-Charge ( Note :- Any T&P required to carry out work shall be arranged by the Contractor.)
M & L for INDIAN / INTERNATIONAL SANDARDS IS; 13573/1992/IEC; 60502/ CENELEC; HD 628.1 629.1/ IEEE;48/VDE;0278 heat shrinkable end termination joint Outdoor/ indoor type dielectric strength 15 KV/mm, tensile strength 1x10E12 N/Sqmm, Elogation 300%, Volm Resist 1x10E11 Ohm.cm suitable for HT XLPE cable of size 95 sqmm 3 core armoured 11000 volt grade heavy duty complete all as specified and directed by Engineer-in-Charge.
M & L for INDIAN / INTERNATIONAL SANDARDS IS; 13573/1992/IEC; 60502/ CENELEC; HD 628.1 629.1/ IEEE;48/VDE;0278 heat shrinkable end termination joint Outdoor/ indoor type dielectric strength 15 KV/mm, tensile strength 1x10E12 N/Sqmm, Elogation 300%, Volm Resist 1x10E11 Ohm.cm suitable for HT XLPE cable of size 120 to 185 Sqmm 3 core armoured 11000 volt grade heavy duty complete all as specified and directed by Engineer-in-Charge.
M & L for INDIAN / INTERNATIONAL SANDARDS IS; 13573/1992/IEC; 60502/ CENELEC; HD 628.1 629.1/ IEEE;48/VDE;0278 heat shrinkable end termination joint Outdoor/ indoor type dielectric strength 15 KV/mm, tensile strength 1x10E12 N/Sqmm, Elogation 300%, Volm Resist 1x10E11 Ohm.cm suitable for HT XLPE cable of size 240 to 300 Sqmm 3 core armoured 11000 volt grade heavy duty complete all as specified and directed by Engineer-in-Charge.
M & L for INDIAN / INTERNATIONAL SANDARDS IS; 13573/1992/IEC; 60502/ CENELEC; HD 628.1 629.1/ IEEE;48/VDE;0278 Cold shrinkable end termination joint Outdoor/ indoor type dielectric strength 15 KV/mm, tensile strength 1x10E12 N/Sqmm, Elogation 300%, Volm Resist 1x10E11 Ohm.cm suitable for HT XLPE cable of size 95 sqmm 3 core armoured 11000 volt grade heavy duty complete all as specified and directed by Engineer-in-Charge.
M & L for INDIAN / INTERNATIONAL SANDARDS IS; 13573/1992/IEC; 60502/ CENELEC; HD 628.1 629.1/ IEEE;48/VDE;0278 Cold shrinkable end termination joint Outdoor/ indoor type dielectric strength 15 KV/mm, tensile strngth 1x10E12 N/Sqmm, Elogation 300%, Volm Resist 1x10E11 Ohm.cm suitable for HT XLPE cable of size 120 to 185 Sqmm 3 core armoured 11000 volt grade heavy duty complete all as specified and directed by Engineer-in-Charge.
M & L for INDIAN / INTERNATIONAL SANDARDS IS; 13573/1992/IEC; 60502/ CENELEC; HD 628.1 629.1/ IEEE;48/VDE;0278 Cold shrinkable end termination joint Outdoor/ indoor type dielectric strength 15 KV/mm, tensile strength 1x10E12 N/Sqmm, Elogation 300%, Volm Resist 1x10E11 Ohm.cm suitable for HT XLPE cable of size 240 to 300 Sqmm 3 core armoured 11000 volt grade heavy duty complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable burnt / defective air break gang operated, triple pole switch from two/ four pole structure by cutting old nuts, bolts etc of any make / any size of 11 KV
S&F switch air break gang operated, triple pole, mechanically operated, mounted on insulator and steel frame with operating mechanism worked from ground level using heavy duty GI pipe, for current rating 200 Amps, outdoor type (conforming to IS specifications) HT 11 KV, triple pole with fixed contacts of phosphorous and bronze and a set of drop out HT fuse assembly, fuse carrier fitting, 12 insulator type mounted on MS channel operating rod with 7 lever pad lock arrangement complete including dismantling old unserviceable switch air break gang operated device. Make JAIPURIA BROTHERS / PACTIL/ BHEL
All as per srl item No. 42 above but for current ratng 400 Amps.
M & L in replacement of Danger notice plate of 1.6mm thick mild steel sheet of size 25x20 cm, vitreous enameled white with letters, figures and conventional skull and bones size, for HT complete all as specified and directed by Engineer-in-Charge.
M & L for Hard core using crushed stone aggregate of gauge not exc. 40mm, deposited spread and leveled in layers not exc. 150 mm thick, rammed to a true surface complete all as specified.
Supply, installation, testing & commissioning in replacement of maintenance free Earth (grounding) electrode of size 85 mm Dia x 03 Meter long with 17.2 mm Copper bonded MS conductor in high purity electrically conductive granular material having ultra low resistive value of 0/001 Ohm-meter. Electrode made of conductive earth enhancing material mixed with Cement in the ration 3:1 backfill the voids surrounding the 17.2 mm copper bonded MS conductor or other metal components placed in augured bore hole of of 100mm dia x 3 meter depth, resulting to increase in the effective surface area of the earth electrode or grids to lower the resistance. Earth enhancing material should not leach chemical into the adjacent soil or underground water channels and should be in pH neutral range. Earth enhancing material should permanently protect the encased metal components of the earthing system, copper bonding on MS rod should be minimum 250 microns. All hardware like nuts, bolts and washers should be of stainless steel. Electrode should withstand fault current upto 35 KA for 1 second. Electrode's top terminal be sealed permanently packed with conductive concrete and copper bonded inclusive of copper strip of size 32 x 6 mm taken out be terminated on to earth test point and equipment terminal upto 7 mtr length. Test certificate of NABL Laboratory shall be submitted by the contractor, test link of size 50mmx6mmx200mm, RCC pit cover test point complete, all as specified and directed by Engr-in-charge. Make:- Elancrete/ ABB/ L&T/ Schneider Note:- I) Test certificate of earthing material from certified NABL laboratory shall be submitted & verified by GE. II) Test Reports should not be more than 07 years old. III) Test Report for Fault current, Rohs compliance, Resistivity value from NABL certified/ CPRI LAB is most and it as to be verified by Engr-in-Charge or GE
Attending minor transformer complaints/ Preventive maint of Transformer by taking proper shutdown of HT feeder from concerned power house, checking, testing and locating faults of HT side/LT side of transformer of any make / any capacity kept on four / two pole structure etc., opening/ disconnecting HT electric connections, removal of old jumpers by cutting of old rusted nuts, bolts & washers etc, replacement of unserviceable jumpers, tightening connections, checking load balancing etc including routine maintenance such as checking minor leakage of transformer silica jell , breather, oil level including replacement of LT /HT side bushing rod etc all as specified and directed by Engineer-in-Charge. Note :- (i) Transformer oil / silica jell / breather if replaced shall be measured and paid separately under appropriate item. (ii) The Supply only spare parts excluding minor parts shall be measured and paid for under relevant items. (iii) T & P and minor repair i.e. replacement of nut/bolts etc. shall be arranged by the contractor and the cost deemed to be included in the unit quoted rates. During currency period of contract, contractor shall depute high skilled trades men for attending the complaint of transformer regularly as and when called with in 24 hours & maintenance shall be carried out accordingly for smooth functioning of transformer and cost of the same shall be deemed to be included in the above coated rates. Please note one time payment shall be made to contractor for these items and if any fault / defects occurred again, contractor shall rectify / replace the same without any extra cost in terms of condition 46 of IAFW-2249 of General condition of contracts..
S & F in replacment lightening arrester metal oxide non-linear expulsion type rupturing capactiy 65 KA, porcelain, conforming to IS-3070 Pt-I suitable for 11 KV , HT over head line complete including nuts, bolts, clamps, brackets etc and connecting with GI wire, discharge capacity 65 Kilo Amps complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of Current transformer (CT) ratio 900/450/577-1A, 50 Hz, 15 VA, accuracy class-I & 5P-10 , short cut time 18.4 KA for 1 sec, as per IS-2705 epoxy type suitable for 11 KV, VCB breaker including all necessary fixing arrangements and proper wiring and connections complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of Current transformer (CT) ratio 900/450/5-5A, 50 Hz, 15 VA, accuracy class-I & 5P-10 , short cut time 18.4 KA for 1 sec, as per IS-2705 epoxy type suitable for 11 KV, VCB breaker including all necessary fixing arrangements and proper wiring and connections complete all as specified and directed by Engineer-in-Charge.
M/s Dashmesh Electrical Engg Works
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .