SUPERINTENDING ENGINEER, EDC, BANDA
Chilla Road, Indira Nagar, Banda
Increasing capacity work of 33/11 KV Sub-Stations as Baberu, Chilla Road and Bhooragarh under EDD/EUDD, Banda
2023_DVVNL_781273_1
EDCBNDA-34/2022-23
Open Tender
Electrical Works
Item Rate
30 days
BANDA
As per annexured
2 documents required · 2 mandatory
₹1,180
DVVNL
₹5,000
O/O SE, EDC, BANDA
28 Jul 2023
4 Mar 2023
21 Mar 2023
4 Mar 2023
21 Mar 2023
4 Mar 2023
18 Mar 2023
The work of increasing capacity of Power Transformer from 8 MVA to 10 MVA installed at 33/11 KV S/S BABERU (Block-BABERU) under BUSINESS PLAN SCHEME 2023-24 under EDD, BANDA, including carriage of all required material/Transformers from ESC/Workshop BANDA to work site, alongwith its loading, unloading & dragging at the respective ends and also safe carriage of old T/Fs from site to store centre/workshop, if any. Material like cable box, hoisting clamps of appropriate size is to be arranged by contractor on his own cost, details of the work as given below ;-
Safe removal of following capacity old transformer from existing plinth as new transformer will be replaced by store and after installation reconnecting transformer to circuit -
8 MVA Transformer
Fixing of 11 KV Indoor type cable jointing kit of size 3x300 sq.mm. with fitting of all accessories as per RESSPO manual (arranged by tenderer at his own cost).
Fixing of 11 KV Outdoor type cable jointing kit of size 3x300 sq.mm. with fitting of all accessories as per RESSPO manual (arranged by tenderer at his own cost).
Repairing of plinth for 10 MVA Power Transformer as per site condition. The contractor shall be responsible to complete the work as per direction of Supervising Engineer.
Making two body earthing and one neutral earthing for transformers as per standard RESSPO norms.
Delta Earthing.
Boring type earthing upto water level (90 Mtr.).
Repairing cable trench from switchgear to transformer and upto 33 KV breacker.
Replacement of OTI, WTI relay cable connections, if required.
4 Core 2.5 Sq.mm.
2 Core 2.5 Sq.mm.
Installation of 33 KV breacker
Installation of 33 KV CT
Installation of 33 KV Control panel
Interconnection with Control panel for proper tripping.
The work of increasing capacity of Power Transformer from 5/8 MVA to 10 MVA installed at 33/11 KV S/S Chilla Road, Banda & Bhooragarh (Block-Badokharkhurd) under BUSINESS PLAN SCHEME 2023-24 under EUDD, BANDA, including carriage of all required material/Transformers from ESC/Workshop BANDA to work site, alongwith its loading, unloading & dragging at the respective ends and also safe carriage of old T/Fs from site to store centre/workshop, if any. Material like cable box, hoisting clamps of appropriate size is to be arranged by contractor on his own cost, details of the work as given below ;-
Safe removal of following capacity old transformer from existing plinth as new transformer will be replaced by store and after installation reconnecting transformer to circuit :-
8 MVA Transformers
5 MVA Transformers
Fixing of 11 KV Indoor type cable jointing kit of size 3x300 sq.mm. with fitting of all accessories as per RESSPO manual (arranged by tenderer at his own cost.)
Fixing of 11 KV Outdoor type cable jointing kit of size 3x300 sq.mm. with fitting of all accessories as per RESSPO manual (arranged by tenderer at his own cost.)
Repairing of plinth for 10 MVA Power Transformers as per site condition. The contractor shall be responsible to complete the work as per direction of Supervising Engineer.
Making two body earthing and one neutral earthing for transformer as per standard RESSPO norms.
Delta Earthing
Boring type earthing upto water level (90 Mtr.)
Repairing cable trench from switchgear to transformer and upto 33 KV breacker
Replacement of OTI, WTI relay cable connections, if required -
4 Core 2.5 mm.Sq.
2 Core 2.5 mm.Sq.
Installation of 33 KV breacker.
Installation of 33 KV CT.
Installation of 33 KV Control panel,
Inter-connection with Control panel for proper tripping.
MAA ELECTRICAL ENERGY
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .