Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.3 LAccepted-AOC | L1 | Accepted-AOC Accepting being lowest | |
| 2 | L2₹36.9 L+₹2.2 L (6.22%)Rejected-Finance PLOT NO 76 CIV SOCIETY MUKUND NAGAR AHMEDNAGAR 414001 | AHMEDNAGAR | AHMEDNAGAR | MAHARASHTRA | 414001 | L2 | Rejected-Finance Rejected being other than lowest | |
| 3 | L3₹38.1 L+₹3.3 L (9.53%)Rejected-Finance | L3 | Rejected-Finance Rejected being other than lowest | |
| 4 | L4₹38.4 L+₹3.6 L (10.4%)Rejected-Finance | L4 | Rejected-Finance Rejected being other than lowest | |
| 5 | L5₹39.2 L+₹4.4 L (12.6%)Rejected-Finance | L5 | Rejected-Finance Rejected being other than lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
10 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Pramod Kumar Tripathi
Military Engineer Services, Garrison Engineer (South) Ahmednagar - 414002
REPAIRS TO ROOF OF 321 MED REGT, 5 MED REGT, ASC SUPPLY DEPOT AND CERTAIN OTM ACCN AT AURANGABAD UNDER GE (S) AHMEDNAGAR
2023_MES_574694_1
8943/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Aurangabad
Class D cat a (i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (South) Ahmednagar
₹1 L
Yes
17 Feb 2023
12 Jan 2023
13 Feb 2023
12 Jan 2023
10 Feb 2023
27 Jan 2023
12 Jan 2023 - 19 Jan 2023
Amount
Demolition of brickwork/stone masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and as directed.
Dismantling asbestos cement sheets in roof (corrugated or semicorrugated) including ridges complete all as specified and as directed.
Taking up or down steel tubing and connections of 15 mm bore complete all as specified and as directed.
Taking up or down steel tubing and connections of 20 mm bore, complete all as specified and as directed.
M&L for brick work with old size bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed.
All as per serial item No 6 but except bricks Note : Old bricks obtained from demolition shall be reused.
M&L for rolled mild steel in roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections conforming to Fe 410-W(Gde-E250) quality A) including distance pieces, cleats etc. all as specified and as directed.
M&L for mild steel work in tubular pipe as in post , purlins, trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 all as specified and as directed.
M&L for plates (plain or chequered) channels. Square cut or notched ) (ordinary and counter sunk) forming holes, without any attachment all as specified and as directed.
M&L for mild steel flat iron for wind ties in roof sheeting including securing bolts, drilling holes all as specified & as directed.
M&L for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long and dia of neck 5 to 10mm all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1: 4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed.
M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of cement paint white or tinted over & including a coat of cement wash complete all as specified and as directed.
M&L for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of colour as approved by GE, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed.
M&L for pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of colour as approved by GE, having tensile strength of 550 Mpa as in roof covering/ridges/valley gutters/cladding to wall, fixed with self tapping screws as specified, coloure and design as approved by GE
M&L for cutting out cracks to V-section in existing roofs or terracing, cleaing out and filling solidly with a hot mixture of bitumen and clean dry sand in ratio 1:1 (by weight) all as specified and as directed.
M&L in repairs, for water proofing treatment to RCC roof slab, including parapet, comprising with the following treatment/specification from bottom to top:- (i) Taking out old roof treatment including levelling concrete/plaster if any and roughening the old concrete slab by picking, sweeping clean and washing down with water to remove dust etc and disposal of rubbish n exceeding 500 mtr distance from starting point as directed. (ii) M&L for 25 mm (average) thick PCC 1:2:4, type B-0, using 12.5 mm graded stone aggregates as levelling course on roof surfaces, mixed with water proofing compound as per manufacturer's instructions, laid to required slope including finishing the concrete surface smooth for laying water proofing treatment. (iii) Cleaning of roof surface and applying one coat of cold bituminous primer @ 0.30 ltr /Sqm conforming to IS:3384-1986. (iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) shall be applied over bituminous primer as specified above by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (v) Applying two coat of aluminium paint over the APP modified membrane @ 0.11Kg/sqm. Note: Water proofing compount will be measured & paid seperatly.
Supply only integral water proofing compound, ISI mark all as specified and as directed.
M & L for preparing surfaces thoroughly by cleaning, washing and removing dust, dirt, oil, grease and loose particles and fill fine crack up to 1 mm with Dr.Fixit roofseal top coat directly by brush or roller after cleaning the cracks stir well prior to application. all joints/corners/drainage outlets and penetration points shall be treated prior to all application of two coat of Dr.Fixit Roofseal Top Coat. all corners, gaps, joints, protrusions and outlets should be coated with an extra coat incorporating reinforcing fabric. Dr.Fixit Roof Seal Coat may be applied by roller,brush. Apply a coat of Dr.Fixit Roof Seal Coat (diluted with water in ratio 2:1) as self priming 9-10 Sq.mtr/Litre. Allow coating to dry for 3-4 hours prior to applying first coat and second coat. Apply two coats of Dr.Fixit Roof Seal Coat @ 2 -2.2 Sq mtr /litre/coat, without water dilution,the rate of application being the same for both the coats. This would ensure correct consumption of material that will deliver a total DFT of 450=500 micron. Allow the system to air cure for 3 days minimum all as specified and as directed.
Disconnecting existing water tank, exc 500 ltrs but n.exc 1000 ltrs capacity, setting aside (or lowering if required) for other repair work, cleaning, etc. and hoisting if required, reconnecting and re-fixing in position all as specified and as directed.
Disconnecting existing water tank, exc 1000 ltrs but n.exc 2000 ltrs capacity, setting aside (or lowering if required) for other repair work, cleaning, etc. and hoisting if required, reconnecting and re-fixing in position all as specified and as directed.
S&F 15mm bore steel water tubes, medium grade, galvanized with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and as directed.
Refixing old steel tubing 15mm bore, with and including new fittings (connections) in new or old position (walls, ceiling, floors, etc) complete all as specified and as directed.
S&F 20mm bore steel water tubes, medium grade, galvanised with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and as directed.
Refixing old steel tubing 20mm bore, with and including new fittings (connections) in new or old position (walls, ceiling, floors, etc) complete all as specified and as directed.
HG PATHAN CONSTRUCTION COMPANY
M/S Tirupati Goroba Shendge
M/s S.R lahoti
R. T. Saluji
sonu enterprises
M/s.M G Kulkarni
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .