Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59.9 LAccepted-Finance 1 C NEPAL BHATTACHARJEE STREET KALIGHAT KOLKATA 700026 | KOLKATA | WEST BENGAL | 700026 | ₹59.9 L | L1 | Accepted-Finance L1 |
| 2 | L2₹64.0 LRejected-Finance 143 C DR RAJENDRA ROAD KOLKATA 700020 | KOLKATA | KOLKATA | WEST BENGAL | 700020 | ₹64.0 L | L2 | Rejected-Finance L2 |
| 3 | L3₹70.0 LRejected-Finance 13 11 MOTILAL GUPTA ROAD KOLKATA 700 008 | KOLKATA | WEST BENGAL | 700008 | ₹70.0 L | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | SHREE GANESH ENTERPRISE L1 | S. K. CHATTERJEE ELECTRICALS PVT LTD L3 | BIKASH ENTERPRISE L2 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling steel tubular pole embedded in CC foundation incl. excavation, filling of holes, restoring surface, loading at site and delivering, unloading, sorting, stacking properly at any place as per direction upto a lead of 1.6 km | 15 | Nos | 775 ₹11,625 | 820 ₹12,300 | 2,000 ₹30,000 |
| 2.00 | Dismantling Feeder Pilar Box embedded in brick foundation incl. excavation, filling of holes, restoring surface, loading at site and delivering, unloading, sorting, stacking properly at any place as per direction upto a lead of 1.6 km | 6 | Nos | 1,788 ₹10,728 | 1,945 ₹11,670 | 1,500 ₹9,000 |
| 3.00 | Dismantaling the existing Sodium vapour light fittings from existing pole with great care & with the help of ladder, sufficient man power& buy back the same and S & F complete LED street light fittings of 250W(min)with necy specification as given below (3.1 to 3.15) | 47 | Nos | 10,891 ₹5,11,877 | 11,235 ₹5,28,045 | 14,000 ₹6,58,000 |
| 3.01Input voltage - 90 V - 270V | ||||||
| 3.02LED lamp efficiency - Min 150 lumen/watt Illumination Min 37500 lumen | ||||||
| 3.03Power facter - > 0.90 | ||||||
| 3.04Expecting life - 50000 Hours(Min) | ||||||
| 3.05High Power LED (2.5 to 4 Watt), IESNALM- 80-08 CERTIFICATE, LED should not drive over current | ||||||
| 3.06Working Humidity - 10% - 90% | ||||||
| 3.07Colour Temperature- 5700 - 6000K with Certificate | ||||||
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
5 Dec 2025, 12:00 pmClosed
The Executive Engineer, Kolkata Electrical Div
The Executive Engineer Kolkata Electrical Division P.W.Dte. BlockI (1st Floor) Writers Buildings, Kolkata 700 001
Restoration of street lights at Mayo Road 2 and Outram Road due to construction of Park Street Underground Metro Station.
2025_WBPWD_945361_1
WBPWD/EEKED/eNIQ-18Q3rd/25-26
Open Tender
ELECTRICAL WORKS ORG
45 days
Park street metro station
Please refer Tender documents.
6 documents required · 6 mandatory
₹1.2 L
O/O The Executive Engineer Kolkata Electrical Divi
21 Jan 2026
11 Nov 2025
8 Dec 2025
11 Nov 2025
5 Dec 2025
20 Nov 2025
19 Nov 2025
Amount
Dismantling steel tubular pole embedded in CC foundation incl. excavation, filling of holes, restoring surface, loading at site and delivering, unloading, sorting, stacking properly at any place as per direction upto a lead of 1.6 km
Dismantling Feeder Pilar Box embedded in brick foundation incl. excavation, filling of holes, restoring surface, loading at site and delivering, unloading, sorting, stacking properly at any place as per direction upto a lead of 1.6 km
Dismantaling the existing Sodium vapour light fittings from existing pole with great care & with the help of ladder, sufficient man power& buy back the same and S & F complete LED street light fittings of 250W(min)with necy specification as given below (3.1 to 3.15)
Input voltage - 90 V - 270V
LED lamp efficiency - Min 150 lumen/watt Illumination Min 37500 lumen
Power facter - > 0.90
Expecting life - 50000 Hours(Min)
High Power LED (2.5 to 4 Watt), IESNALM- 80-08 CERTIFICATE, LED should not drive over current
Working Humidity - 10% - 90%
Colour Temperature- 5700 - 6000K with Certificate
Ingress proctection- IP66 as per IEC60529 - 2001 with test certificate
Colour rendering index- Ra≥80
Working Temperature - 0 deg C to 50Deg C
Control Circuit /Driver - : BIS apporoved, Dry & Damp protection ,IS 15885(part 2/Sec 13) , 10 KV surge protection & atleast combination of 2 drivers.Total Driver rating should be higher than luminare rating
Luminary Casing - Pressure Die cast Aluminium with toughened glass cover & water proof fixture IP66
LED Thermal manegement : LED shall be mounted on heat sink conductive aluminium with fins to dissipate the heat to ambient air,Minimum weight per watt 0.036Kg
Warranty for Illumination level - 5 years & Illumination level should not be less than 80% after 5 years
Supply of 12 mtr long ST MS pole (Model-410 SP 60).Overall length 12 mtrs & planting depth 2 mtrs.Length of section bottom-5.80 mtr,middle-3.10 mtr and top 3.10 mtr long out side thickness of section bottom 165.1X 5.40 mm,middle-139.7 X 4.50 mm and top 114.3X 3.65 mm with base plate as per direction of EIC. Approx weight of pole-208 Kg. without arm bracket (Make -Calcutta Pole/Bansal/Utkarsh)
Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick net cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly. above 9 mtr. pole.
Extra on item 5 above, for providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) suitable for alkathene/ polythene pipe entry as directed for street light wiring, incl. S & F 25cmx25cmx10cm GI Loop box, 16SWG & incl. drilled hole in pole
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint Above 9.0 mtr. long pole One coat of red lead/Zinc chromate priming. 1st coat of synthetic enamel paint over the primer. 2nd coat of synthetic enamel paint over the 1st coat.
Painting Block Letters or Digits within a circle/square as required-Size 50 mm and upto 75 mm.
Supply and Fixing of single arm header assembly fabricated from 40mm dia. 2 mtr long GI Pipe arm (ISI-M) rigidly welded with 88.9 mm dia. GI Pipe arm bracket (ISI-M) of 0.3 Mtr. long as pole sleeves at an angle of 90⁰ including S/F 3Nos ½” MS jam nut each with 1No. ½” dia. through bolt and painting of the entire assembly as to GS.
Supply and Fixing of double arm header assembly fabricated from 40mm dia. 1.5 meter long GI Pipe arm (ISI-M) rigidly welded with 170 mm dia. GI Pipe arm bracket (ISI-M) of 0.3 Mtr. long as pole sleeves at an angle of 90⁰ including S/F 3Nos ½” MS jam nut each with 1No. ½” dia. through bolt and painting of the entire assembly as to GS.
S & Drawing 3 core 2.5 sqmm PVC insulated multisranded copper cable from Loop Box to pole Fixture (Make- Havells, RR Kabel, Polycab).
Excavation of soil for installation of Earth Electrode and filling & ramming (for soft soil).
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level by ISI Medium GI pipe.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe .
Connecting the equipments to earth busbar including S & F 4 SWG GI (Hot Dip) wire on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.
Supply & Delivery of 1.1 Kv grade 4 Core 16 Sqmm XLPE Armoured Aluminium Cable (Make- Polycab / RR Kabel / Havells / Gloster)
Supply& Delivery of 1.1 Kv grade 4 Core 35 Sqmm XLPE Armoured Aluminium Cable. (Make- Polycab / RR Kabel / Havells / Gloster)
Supply& Delivery of 1.1 Kv grade 4 Core 50 Sqmm XLPE Armoured Aluminium Cable. (Make- Polycab / RR Kabel / Havells / Gloster)
Supply & Delivery of 1.1 Kv grade 4 Core 70 Sqmm XLPE Armoured Aluminium Cable (Make- Polycab / RR Kabel / Havells / Gloster)
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core.
Laying only Cable above 50 sqmm but not exceeding 400sqmm through existing RCC/ Hume/GI Pipe/open masonary trench for single, 2, 3, 3½ and 4 core.
Laying of one No. cable upto 50 sqmm through microtunneling with 50 mm OD HDPE (5 mm thick) pipe 1 mtr below the ground and laying the cable through the pipe by cutting entry prockets at both ends a depth of 1 mtr and 0.3 mtr width and making masonary pit at both ends at each location for at least eight locations by brick, sand , cement etc incl. top cover as required as per direction of EIC.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below.
4 core 16 sq.mm
4 core 35 sq. mm
4 core 50 sq. mm
4 core 70 sq. mm
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc.
4 core 16 sq.mm
4 core 35 sq. mm
4 core 50 sq. mm
4 core 70 sq. mm
Supplying & fixing 80 mm dia medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required.
Supplying and fixing 415V,125A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.(PWD approved make)
Supplying and fixing sheet steel (16SWG) cable end box on 125A TPN SFU enclosure with nuts bolts etc incl. powder coated painting.
Supply and fixing of LED rope(without Adapter) in spriral manner at a gap of 6'' with blue and white colours on existing steel tubular pole/iron Structure including necessary fixing arrangements, cleaning and mending good the damages, with the specification as - LED Count: 60 Nos/Mtr, Power-Min 6Watt/Mtr, Lumen: 6-8 Lumen/Mtr, (Make: philips/Crompton/Wipro) with a warranty of minimum three year.Those damaged Strip needs to be replaced as and when called for, free of cost.This will be connected by original company provided connector as per direction of EIC(White-550mtr,Blue-550mtr)-DLP- 3 years.
Supply & Fixing of Power adapter for stream IP65 LED strip(Make: Philips/Crompton/Wipro)-DLP- 3 years.
Supply & fixing of 250V, 2pin 6A capacity male female plug set for exixting LED strip light.
Design, Manufacturing, Supply, Installation, Testing and Commissioning of a outdoor type (Min. IP66 rated) feeder pillar box having size 1650(H) X1450(W) X900(D) mm as per GTP-Annexure-I (An AutoCAD drawing of the feeder pillar should be approved by EIC before starting fabrication of feeder pillar).
Design, Manufacturing, Supply, Installation, Testing and Commissioning of a outdoor type (Min. IP66 rated) feeder pillar box having size 1650(H) X1450(W) X750(D) mm as per GTP.-Annexure-I (An AutoCAD drawing of the feeder pillar should be approved by EIC before starting fabrication of feeder pillar).
Supply & fixing of 4 way , 250V, 32A capacity porcelain connecter in existing pole header and connecting the same with the incoming cable and outgoing wires incl necessary socketing.
Charges for removing the paver blocks and cutting the cement concrete 300mm wide x 200 mm average depth and refixing the paver blocks as to orginal finish with cc mixure & sand after laying the cable as per direction of EIC.
Supplying & fixing of 300/350 mm dia (as per existing pole dia) insulating PVC heat sleeve of blue colour on existing ST pole for insulation purpose upto a height of 2 mtr above muffing. The sleeve is to be fixed on pole body firstly by cutting along the length and to be wrapped around the pole upto desired height and then the cut portion is to be sealed firstly by applying cyanoacrylate based instant super glue along the cut length and then applying heat by heat gun for shrinking effect as per direction of EIC.
Special Terms and conditions
In case of defective / less illumination within DLP of LED fittings the agency should replace the fittings at pole end with it’s own cost.
The agency must procure the materials form manufacturer /OEM/or from their authorized sales channel so that the warranty / support of the manufacturer /OEM becomes applicable to the products to be delivered and installed by them.
Documents that authenticates such procurement from the Manufacturer /OEM and standard warrenty/ support for 5 years should be sent from the e-mail of the Manufacturer /OEM /authorised sales channel to the e-mail of Engineer -in- Charge mentioning NIT/NIQ and hard copy of it to be submitted during execution of work /submission of bill.
BIKASH ENTERPRISE (BID ID -7787414)
S. K. CHATTERJEE ELECTRICALS PVT LTD (BID ID -7758888)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.47 MB
Tendernotice_2.pdf
PDF • 0.72 MB
2911.pdf
Tender Documents • 0.54 MB
BOQ_2246292.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid