Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC 27 1ST STREET PERIYAR NAGAR 1ST STREET PERIYAR NAGAR ADAMBAKKAM KANCHIPURAM TAMIL NADU 600088 | CHENNAI | TAMIL NADU | 600088 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹7.7 L+₹39,650 (5.45%)Rejected-AOC PLOT NO 15 JAYASURIYA STREET GANGAI NAGAR KALLIKUPPAM AMBATTUR CHENNAI 600053 | CHENNAI | CHENNAI | TAMIL NADU | 600053 | L2 | Rejected-AOC Other than lowest bidder |
Tender Value
₹7.8 L
EMD Value
₹15,600
Closing Date
3 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE(I) Navy Chennai
AGE(I) Navy Chennai Military Engineer Services Fort St George Rajaji Salai Chennai 600 009
REPAIR/MAINTENANCE OF UPS AND BATTERIES AT VARIOUS LOCATION UNDER AGE(I) NAVY CHENNAI
2022_MES_563049_2
AGE(I)/NAVY/CHN/8352 of 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
Chennai
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE(I) Navy Chennai
₹15,600
Yes
17 Jan 2023
14 Dec 2022
4 Jan 2023
14 Dec 2022
3 Jan 2023
15 Dec 2022
Amount
Maintenance of online UPS 5 KVA at TS Avadi for smooth running and functioning as per schedule of maintenances complete all as specified and directed
Notes for Sl item No. 1 to 4 : (i) The above maintenance include complete maintenance of existing UPS by regularly and systematically examining adjusting fabricating as and when required for smooth and efficient functioning of the UPS. (ii) After complaint lodging within 02 hours technician required to reach on site including Sundays and Holidays. (iii) The contract including 100% repairing of spare parts like PSDR CARD ,CNTL CARD, CHARGER CARD,control and power transformer ,electrical switchgear, fuses (if applicable), dust filters, indicating lamps, however repairing of above components will be part of scope if repairable (Except batteries). (iv) Disconnecting,Fixing and testing charges of battery will be included in the quoted rate.Old battery should be deposited to E/M store . (v) Monthly check shall be carried out by contractor (vi) Contractor have to submit mainanence report duly signed for each UPS separately as per performa.
Notes for Sl item No. 1 to 4 (Contd) : PREVENTIVE MAINTENANCE SERVICE AS FOLLOWS:- (a) Cleaning up of unit, Visual Inspection to check any deformation. (b) Checking and Adjustment (if needed) of Power parameters like input, output, DC voltage and AC voltage. (c) Checking and Adjustment (if needed) of Control parameters on different PCBs. (d) Tightness of all connection, if unit shut down possible. (e) Functional Checking up of Rectifier, Inverter and Static Switch Section. (f) With customer approval, perform operational test of the system including unit transfer and battery disharge. (g) Install or perform Engineering Field Change Notices (FCN) as necessary. (h) Battery health check ups 04 times during the comprehensive maintanence period for which shut down shall be co-ordinated with the approval/ permission of User
Maintenance of solar panel operated online UPS 5 KVA at 2 N Det Vellachi for smooth running and functioning as per schedule of maintenances including attending to jobs as mentioned under item No.1 here in before complete all as specified and as directed.
Maintenance of solar panel operated online UPS 10 KVA at 2 N Det Vellachi for smooth running and functioning as per schedule of maintenances including attending to jobs as mentioned under item No.1 here in before complete all as specified and as directed.
Maintenance of online UPS 10 KVA at COMCEN for smooth running and functioning as per schedule of maintenances including attending to jobs as mentioned under item No.1 here in before complete all as specified and as directed.
Supply only charger card for 5 KVA UPS
Supply only charger card for 10 KVA UPS
Supply only PCB of invertor for 5 KVA UPS
Supply only PCB of invertor for 10 KVA UPS
Supply only capacitor suitable for 5 KVA UPS
Supply only capacitor suitable for 10 KVA UPS
Supply only control and power transformer for 5 KVA UPS
Supply only control and power transformer for10 KVA UPS
Supply maintenance free sealed type, Inverter battery of 200 AH capacity and electro volume: 10.4 litres, charging current 10.5, complete all as specified and directed. Makes: Exide IP 2000 FIPO- IP 2000 or equivalent
Supply maintenance free sealed type, Inverter battery of 150 AH capacity and electro volume: 10.4 litres, charging current 10.5, complete all as specified and directed. Makes: Exide IP 1500 FIPO- IP 1500 or equivalent
Supply and fixing bracing supports, clamps and back plates,flats fabricated from structural steel sections (angles) including nuts,bolts,washers,welding, bending cold or hot, drilling holes for bolt, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint, complete all as specified and directed.
Banyan Engineers and Contractors
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .