| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.8 LAccepted-AOC RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | 1 | Accepted-AOC LOWEST | |
| 2 | 2₹12.6 L+₹55,875 (4.64%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | 2 | Rejected-Finance NOT LOWEST | |
| 3 | 3₹12.9 L+₹88,370 (7.34%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | 3 | Rejected-Finance NOT LOWEST | |
| 4 | 4₹13.8 L+₹1.8 L (14.8%)Rejected-Finance | 4 | Rejected-Finance NOT LOWEST | |
| 5 | 5₹14.9 L+₹2.9 L (23.9%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | 5 | Rejected-Finance NOT LOWEST |
Tender Value
₹31 L
EMD Value
₹62,000
Closing Date
20 Jul 2024, 6:00 pmClosed
GE (AF) PALAM
GE (AF) PALAM DELHI CANTT-10
REPAIR/ REPLACEMENT / MAINTENANCE OF STREET LIGHTS / SECURITY LIGHTS AND ALLIED WORKS AT AF STN STN PALAM UNDER GE (AF) PALAM DELHI CANTT-10
2024_MES_661375_1
8024/A/T-25/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) PALAM DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) PALAM
₹62,000
Yes
30 Oct 2024
22 Jun 2024
27 Jul 2024
22 Jun 2024
20 Jul 2024
6 Jul 2024
Amount
Taking down unserviceable light fittings from the tarmac/ dispersal / taxi track by removing glass cover and checking the unserviceable parts like copper wire, capacitors & control gear box and LED light connetror copper, copper wire, electric driver, states of servicability etc and re-fixing the fittings back to its original position after carried out all necessary repairs to make the fitting serviceable complete all as specified and as directed. Note:- The spare parts to be replaced shall be measured and paid separately under respective items here-in- after.
Taking down unserviceable light fittings from the high mast by lowering the high mast by winch & motor including checking the unserviceable parts like electronic driver, copper wire link, unserviceable hight mast light, overhauling rope wire, rope wire, nut, bolt, clamp and re-fixing the fittings back to its original position after carried out all necessary repairs to make the fitting serviceable complete all as specified and as directed. Note:- Light fitting, connecting wire, driver etc to be replaced shall be measured and paid separately under respective items here-in- after.
S&F in replacement of LT 3 phase 4 wire 415 volts transparent Kiosks cubical pole box moulded in single piece of size 350mmx250mmx150mm, shock proof, rust proof, fire retardant with 4 Nos aluminium bus bar of capacity 100 Amps mounted on DMC unbreakable insulators complete all as specified and as directed.
Supply only in replacement of electronic driver for LED flood light 100/120 watt, as per existing flood light model complete all as specified and as directed.
Supply only in replacement of electronic driver for LED flood light 150/250 watt, as per existing flood light model complete all as specified and as directed.
S&F in replacement of traffic light LED type red/green/white/Blue/Orange, 24 hrs operation 300 mm round light source, visibility> 500 mtrs, operating voltage 230 Volt AC complete with polycarbonate enclosure and clear diffuser complete all as specified and as directed.
S&F in replacement LED Aviation 6 W Obstruction Light with yellow painted die cast aluminium alloy housing with polycarbonate enclosure complete all as specified and as directed.
S&F in replacement of analog type time switch 3P module, DIN 24 hours programmable every 30 minutes of current capacity 16 Amps with one change over including connecting to existing power contactor complete all as specified and as directed.
S&F in replacement of digital type time switch 3P module, DIN 24 hours programmable every 30 minutes of current capacity 16 Amps with one change over including connecting to existing power contactor complete all as specified and as directed.
Supply and fixing in replacement of Power contactor 40 A, 4 pole of timer panel complete all as specified and as directed.
Excavation in trenches in soft/loose soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep and getting out for taking out /laying cable, poles & stay etc complete all as specified and as directed.
Returning, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid and tested complete all as specified and as directed.
Removal of excavated surplus soil to a distance not exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed.
M&L for sand cushioning to under ground cable provided with layer of sand (8 cm deep before laying the cable and 15 cm deep after laying the cable i.e total 23 cm) complete all as specified and as directed.
M&L for brick of burnt clay sub class ‘B’ laid dry flat in trenches for cable protection complete all as specified and as directed.
Taking out old unserviceable LT under ground cable of any type/ size from trenches, pipes & poles complete all as specified and as directed.
S&F cable XLPE insulated under ground 1100 volt grade with stranded aluminium conductor of 16 Sqmm 4 core sizes in trenches /passing through pipes/ on poles etc complele all as specified and as directed.
S&F cable XLPE insulated under ground 1100 volt grade with stranded aluminium conductor of 25 Sqmm 4 core sizes in trenches /passing through pipes/ on poles etc complele all as specified and as directed.
S&F cable XLPE insulated under ground 1100 volt grade with stranded aluminium conductor of 50 Sqmm 3.5 core sizes in trenches /passing through pipes/ on poles etc complele all as specified and as directed. Note for ser item No. 17.00 to 19.00:- Excavation, earth work and protection of cable shall be measured and paid seperately under respective items of BOQ.
S&F in replacement LED flood light fitting 100 watt with internally prewired including electronic driver and connecting up with three core flexible copper conductor 1.5 sqmm cable complete all as specified and as directed.
S&F in replacement of LED flood light fitting 120 watt with internally prewired including electronic driver and connecting up with three core flexible copper conductor 1.5 sqmm cable complete all as specified and as directed.
S&F in replacement of LED flood light fitting 150 watt with internally prewired including electronic driver and connecting up with three core flexible copper conductor 1.5 sqmm cable complete all as specified and as directed.
S&F in replacement of LED flood light fitting 200 watt with internally prewired including electronic driver and connecting up with three core flexible copper conductor 1.5 sqmm cable complete all as specified and as directed. (for High mast lights).
S&F in replacement of LED flood light fitting 250 watt with internally prewired including electronic driver and connecting up with three core flexible copper conductor 1.5 sqmm cable complete all as specified and as directed. (for High mast lights).
Supply and fixing of high efficient LED flood light fitting with thermal management and equipped with IP66 protection of 300 Watts complete with driver, control box etc and connection with suitable size copper wire etc complete all as specified and as directed.
S&F in replacement of control cable PVC insulated copper conductor 2.5 sqmm 3 core complete all as specified and as directed.
S&F in replacement of control cable PVC insulated copper conductor 4.0 sqmm 3 core complete all as specified and as directed.
M&L in replacement of PVC insulated service cable flat or round sheathed, aluminium, multistranded conductor 1100V grade size 16 Sq mm 2 core complete all as specified and as directed.
M&L in replacement of PVC insulated service cable flat or round sheathed, aluminium, multistranded conductor 1100V grade size 10 Sq mm 2 core complete all as specified and as directed.
Supply and fixing in replacement of electric motor 2 HP heavy duty capacity 415 volts 50Hz , 900 RPM with gear 100 mm dia and chain machanism suitable to existing system to drive the high mast light up and down complete all as specified and as directed.
S&F in replacement of MCCB 3 pole, 415 volts, 16 kA rupturing capacity 125 Amps complete all as specified and as directed.
S&F in replacement of MCCB 63 A, 4 pole 10 kA of timer panel complete all as specified and as directed.
S&F in replacement MCB TPN 40 Amp rating, 240V, 10kA, with connection testing and commissioning complete all as specified and as directed.
S&F in replacement MCB TPN 63 Amp rating, 240V, 10kA, with connection testing and commissioning, complete all as specified and as directed.
S&F in replacement MCB TP 63 Amp rating, 240V, 10KA, with connection testing and commissioning complete all as specified and as directed.
Taking down unserviceable street/ security/ light fittings complete (HPSV/HPMV/MH/LED) from the pole, tower, bldg etc for repair and refixing the same back to its original position after making the fitting serviceable complete all as specified and as directed. Note:- Spare/ parts like ballast, igniter, control gear box, lamp, electronic driver etc required for making the fitting serviceable shall be measured and paid seprately under relevant items of the BOQ.
S&F in replacement of LED 60 watt consisting of a high efficient LED street light made of aluminium die cast aluminium housing with lens, IP66 complete all as specified and as directed.
S&F in replacement of LED 90 watt consisting of a high efficient LED street light made of aluminium die cast aluminium housing with lens, IP66 complete all as specified and as directed.
S&F in replacement of LED 120 watt consisting of a high efficient LED street light made of aluminium die cast aluminium housing with lens, IP66 complete all as specified and as directed.
S&F in replacement of LED 45 watt consisting of a high efficient LED street light made of aluminium die cast aluminium housing with lens, IP66 complete all as specified and as directed.
S&F GI pipe light grade 40 mm dia bracket (min length 1.2 mtr) to make L type for bldg light fittings complete all as specified and as direted.
S&F of MS flat clamp of size 30mm x 5mm thick including nuts, bolts and washer suitable for bldg light fitting complete all as specified and as directed.
S&F LED bollard light fitting 10W with opal diffuser and aluminium reflector, with all accessories internally prewired and including connecting up with twin core copper conductor cable complete all as specified and as directed.
M/S Anand Enterprises (BID ID -3068277)
Commercial Traders (BID ID -3059869)
M/s Prakash Enterprises (BID ID -3059826)
Saini Enterprises (BID ID -3058900)
friends associeates (BID ID -3058660)
AMIT ENTERPRISES (BID ID -3069161)
Ridhi engineers and builders (BID ID -3059934)
GILL ENGINEERS (BID ID -3060825)
RS GREEN INDIA CONSTRUCTION (BID ID -3068824)
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .