| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.2 LAdmitted-Finance 993 14 VASANT VIHAR JIND HARYANA | JIND | JIND | HARYANA | -8.01% | ₹3.2 L | L1 | Admitted-Finance |
| 2 | L2₹3.2 L+₹3,509.27 (1.10%)Admitted-Finance HOUSE NO 156 VILLAGE CHAPRA P O BITHA AMBALA | AMBALA | AMBALA | HARYANA | -7.00% | ₹3.2 L+₹3,509.27 (1.10%) | L2 | Admitted-Finance |
| 3 | L3₹3.3 L+₹10,875.25 (3.40%)Admitted-Finance BOOTH NO 119 ECTOR 9 PANCHKULA | PANCHKULA | HARYANA | 133301 | -4.88% | ₹3.3 L+₹10,875.25 (3.40%) | L3 | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | - | Not Admitted-Fee/PreQual/Technical Others-The firm rejected due to the reason that the firm has not submitted Chief Electrical Inspector Haryana Chandigarh as required as per approved CBD. The firm has also not submitted the undertaking and affidavit as per approved CBD/NIT. |
Tender Value
₹3.5 L
EMD Value
₹6,940
Closing Date
14 Sept 2026, 10:00 amClosed
Ashok Kumar Rana
Electrical Panchkula
REPLACEMENT OF DAMAGED AIR CONDITIONERS IN HSVP OFFICE BUILDING SECTOR-8 AT U/E AMBALA CITY.(INCLUDING ONE YEAR FREE MTC AND DEFECT LIABILITY PERIOD FREE OF COST).
2026_HBC_545131_1
20264374EBD4 0BE8 4660 8F41 D3EFABBB111B245HSV
Open Tender
Electrical Works
Works
45 days
Ambala City
2 documents required · 2 mandatory
₹250
₹6,940
Yes
17 Sept 2026
2 Sept 2026
15 Sept 2026
2 Sept 2026
14 Sept 2026
2 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | [23.22.3.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 3.2. Supply and erection of sheet steel enclosures 1pole/2 pole/4 pole on wall/on existing pedestal complete as required. S.P.N. or DP enclosure suitable for DP MCB | 4 | Each | 356 | ₹1,424 |
| 2 | [23.22.5.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.4. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Double pole | 4 | Each | 677 | ₹2,708 |
| 3 | [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. | 60 | Metre | 32 | ₹1,920 |
| 4 | HSR 23.33.1.1 :- Supplying, installation, Testing and Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply etc 2 kva | 1 | Each | 66,334 | ₹66,334 |
| 5 | Less Credit of Old/Damaged 1.5/2.0 TR Split Type Air Conditioner complete in all respect. | 2 | Each | -4,000 | - |
| 6 | Providing and fixing of factory made heavy duty galvanised anodised with powder coating 60micron stand for AC outdoor unit on walls at all lvel including hardware complete in all respect | 4 | Each | 768 | ₹3,072 |
| 7 | Rate Analysis on HSR BASIS (25.10.14)
COPPER REFRIGERANT PIPING
Supplying, Installation, testing and commissioning including vaccumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
15.86 mm dia (OD)(SOFT) with tube thickness 1.2 mm
(25.10.14.4) | 50 | Metre | 521 | ₹26,050 |
| 8 | Rate Analysis on HSR BASIS (25.10.14)
COPPER REFRIGERANT PIPING
Supplying, Installation, testing and commissioning including vaccumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
9.5 mm dia (OD)(SOFT) with tube thickness 1.2 mm
(25.10.14.2) | 50 | Metre | 293 | ₹14,650 |
| 9 | Rate Analysis on HSR BASIS (25.11.2.4)
HI - WALL SPLIT SYSTEMS Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low and high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 °C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 °C (out door ambient temperature). Inverter Type- Cooling only
2.0 TR with 5 Star BEE Rating | 4 | Each | 48,641 | ₹1,94,564 |
| 10 | Supply and erection of 4 KVA Voltage Stabilizer for 1.5/2.0 TR Split A.C copper wound as per specification of make V-Guard, Microtek complete in all respect upto the entire satisfaction of Engineer in- Charge (Excluding GST. | 4 | Each | 4,860 | ₹19,440 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.92 MB
BOQ_624687.xls
BOQ • 0.33 MB
AD0172143.pdf
Additional Documents • 0.60 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .