| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.3 LAccepted-AOC | L1 | Accepted-AOC Contract is awarded to M/s N D Karande | |
| 2 | L2₹48.1 L+₹58,838.50 (1.24%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than lowest quoted rate | |
| 3 | L3₹48.5 L+₹99,532.50 (2.09%)Rejected-Finance | L3 | Rejected-Finance Rejected being other than lowest quoted rate | |
| 4 | L4₹48.6 L+₹1.1 L (2.25%)Rejected-Finance | L4 | Rejected-Finance Rejected being other than lowest quoted rate | |
| 5 | L5₹49.3 L+₹1.8 L (3.77%)Rejected-Finance | L5 | Rejected-Finance Rejected being other than lowest quoted rate |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
1 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Ankur Goyal IDSE Garrison Engineer
Military Engineer Services, Garrison Engineer (South) Ahmednagar - 414002
PROVISION OF GUARD ROOM WITH TOILET/ BATHROOM AND 20 MEN TOILET/ URINAL BLOCK AT MAC GP, MIC and S UNDER GE (S) AHMEDNAGAR
2024_MES_673764_1
8181/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Ahmednagar
Class D Cat a(i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (South) Ahmednagar
₹1 L
Yes
17 Jan 2025
10 Sept 2024
3 Oct 2024
10 Sept 2024
1 Oct 2024
24 Sept 2024
10 Sept 2024 - 17 Sept 2024
Amount
Surface dressing not exc 15 cm deep in soft / loose soil complete all as specified and as directed.
Excavation in trenches not exc 1.5m wide and not exc 1.5 m deep & getting out in any type of soil for foundations etc and getting out complete all as specified and as directed.
Excavation in trenches not exc 1.5m wide and exc 1.5m but not exc 3 m deep & getting out in any type of soil for foundations etc and getting out complete all as specified and as directed.
Excavation in trenches not exc 1.50m wide and not exc 1.50m depth in hard rock for foundation etc and getting out complete all as specified and as directed.
Excavation in trenches n. exc 1.50m wide and exc 1.50m but not exc 3m in depth and getting out in hard rock for foundation and getting out complete all as specified and as directed.
Excavation by mechanical means in any kind of soil (hydraulic excavator) over areas (exc 30 cm in depth, 1.5 m in width and exc 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, complete all as specified and as directed.
Excavation over areas not exc 1.50 m deep and getting out in any type of soil all as specified and as directed.
Excavation by mechanical means in any kind of soil (hydraulic excavator) over areas (exceeding 1.5m but not exceeding 3m in depth, exc 1.5 m in width and exc 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m inclu necessary lift and complete all as specified and as directed.
Returning filling in including spreading, levelling, watering and well ramming in layers in any type of soil not exc 25cm complete all as specified and as directed.
Removal excavated soil not exc 50m and depositng where directed at a level not exc 1.5m above the starting point complete all as specified and as directed.
Removal excavated soil exc 250m but not exc 500m and depositng where directed at a level not exc 1.5m above the starting point complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation and mass concrete complete all as specified and as directed.
Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete complete all as specified and as directed.
Use and waste formwork to sides of pillars, posts, struts, piers, columns and stanchions squre, rectangular or polygonal for rough finished surfaces of concrete complete all as specified and as directed.
Use and waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams,etc for rough finished surfaces of concrete complete all as specified and as directed.
Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exc 200mm thick (Horizontal or sloping) for rough finished surfaces of concrete complete all as specified and as directed.
Use and waste formwork to edges of concrete roofs n exc 20cm wide for fair finished surfaces and similar work for rough finished surfaces of concrete complete all as specified and as directed
Use and waste formwork to chajjas, trough and simmilar items including edges for rough finished surfaces of concrete complete all as specified and as directed
M&L for reinforced cement concrete, M-25 Design mix (20mm graded stone aggregate) as in foundations including rafts, footings, foundation beams; plinth beams; bases for columns, etc complete all as speified.
M&L for reinforced cement concrete, M-25 design mix (20mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and as directed
M&L for reinforced cement concrete, M-25 Design mix (20mm graded stone aggregate) as in beams, cantilevers, bressummer lintel over 1.5m span complete all as specified and as directed
M&L for reinforced cement concrete, M-25 Design mix (20mm graded stone aggregate) as in chajjas complete all as specified and as directed
M&L for reinforced cement concrete, M-25 Design mix (20mm graded stone aggregate) as in shelves and the like complete all as specified and as directed
M&L for reinforced cement concrete, M-25 Design mix (20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for precast reinforced cement concrete, 1:2:4, type B-1, using 20mm graded stone aggregate as in precast manhole covers including necessary forms and moulds complete all as specified and as directed.
M&L for moorum filling in floors or paving, laid in layers not exc 15cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
M&L for hardcore of gauge not exc 63 mm size of broken stone or boulder, deposited, spread and levelled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 75mm thick plain cement concrete, 1:4:8 type D2, using 40 mm graded stone aggregate as in sub base complete all as specified and as directed.
M&L for brick work with old size fly ash bricks, as in half brick thick walls straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and as directed.
M&L for precast cement concrete block masonry with PCC 1:5:8 (using 20 mm graded aggregate) solid blocks exc 10 cm in width and setting in cement mortar 1:6 complete all as specified and as directed.
M&L for AAC block massonry exc 10cm in width of grade-I (Min compressive strength 5N/Sqmm), Density 651-750Kg/Cum and shall be laid using polymer modified and curing free ready mix jointing mortar of joint thickness 3mm to 4mm complete all as specified and as directed. Note : Make of ready mix jointing mortar shall be as approved by GE
M&L for reinforced cement concrete,1:2:4 Type B0 (using 12.5mm graded stone aggregate) as in cills, seismic and other similar bands and the like including use of form work complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified as directed.
M&L for mild steel TMT bars 5mm and over upto and including 10mm dia, cut to length, bent to shape required, including crankng as in stirrups with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and as directed.
M&L for rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished surfaces even & smooth without using extra cement complete all as specified and as directed.
M&L for rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished surfaces even & smooth without using extra cement including a layer of sagol finish complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even & fair without using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on brick or concrete surfaces finished surfaces even & smooth without using extra cement complete all as specified and directed.
M&L for rendering 5mm thick on ceiling surfaces in cement mortar 1:3 on fair faces of concrete surfaces including finishing even & smooth without using extra cement all as specified and as directed.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint over one coat of primer all as specified and as directed.
M&L for preparation of new plastered surfaces of walls and applying 1.5 to 2mm thick wall care putty to achieve smooth surface and applying two coats of oil bound distemper of approved shade/tint over a coat of compatible priming paint complete all as specified and as directed.
M&L for preparation of new plastered wall surfaces and applying three coats of white wash complete all as specified and as directed .
M&L for preparation of new plastered ceiling surfaces and applying three coats of white wash complete all as specified and as directed .
M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top:- (i) Surface roughening concrete slab by picking, sweeping clean and washing down with water to remove dust etc and applying cement slurry @3kg/Sqm. (ii) Screed bed or bedding layer of mortar 1:4 in 15 mm thick for laying as in roof slab with mixing of WPC (3% of cement content) and surface finished fare and smooth without using extra cement. (iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr /Sqm conforming to IS:3384-1986. (iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be laid/ applied over bituminous primer as specified above, an application of polymeric membrance shall by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (v) Applying one coat of aluminum paint over the APP modified membrance @ 0.11Kg/sqm. Note: WPC shall be measured and paid for under separate item.
Supply only water proofing compound complete, ISI mark all as specified and as directed.
M&L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in plinth protection, etc finished the surface even and smooth without using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic joint filling at every 3m length and at corners complete all as specified and as directed.
M&L for 18 to 22 mm thick machine cut kota stone flooring (size of kota stone slab 18"x22") laid over and including 20 mm thick bedding layer of cement mortar 1:6 jointed with grey cement slurry mixed with pigments to match the shade of slab including cutting, rubbing and mirror polishing complete all as specified and as directed.
All as per serial item No. 47 but 18 to 20 mm thick kota stone on vertical surfaces such as in skiting /dado of size as required at site over and including 10 mm thick backing coat of cement mortar 1:4.
M&L for 20-25 mm thick, machine cut Cudappah stone slab flooring, jointed with grey cement slurry mixed with pigments to match the shade of slab including cutting, rubbing complete all as specified and as directed.
M&L for 18-20mm thick Granite (of any type ) work (table rubbed and polished ) in steps, jambs, pillers, window cills, coocking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marbel dust with admixture of pigment to match with shade of granite all as specified and as directed.
Providing edge moulding to 18-20 mm thick granite stone of counters, vanities etc. including machine polishing to edge to give high gloss finish etc complete all as specified and as directed.
M&L for 7-8mm thick non skid coloured ceramic tiles (square or rectingular) area of each tile exc 0.06 sqm but not exc 0.11 sqm in floors etc, colour/shade as approved by GE, set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles over & including 15mm thick screed bed in cement mortar 1:6 complete all as specified & as directed.
M&L for 7 to 8 mm thick non-skid ceramic colour tiles, (square/rectangular), area of each tiles exc 0.11 Sqm but not exc 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 15 mm thick screed bed in cement sand mortar 1:6 complete all as specified and as directed.
M&L for glazed coloured ceramic tiles of size 450x300x7mm thick in vertical surfaces, colour/shade as approved by GE, set and jointed in neat cement paste and pointed in white or coloured cement to match with the tiles over & including 10mm thick rendering in cement mortar 1:4 complete all as specified & as directed.
M&L for 60mm thick factory made, chamfered edge, cement concrete interlocking paver blocks with glossy finish of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed
M&L for plain cement concrete, 1:2:4 type B1, using 20mm graded stone aggregate as in kneelers, apex stones, bed plates, kerb not provided for water trough and the like including weathering, slightly rounded or chemfered angles and throating, complete all as specified and as directed.
M&L for plain cement concrete 1:3:6, type C1 using 20 mm graded stone aggregate as in coping etc including form work complete all as specified and as directed.
S&F pressed steel doors frames of size 105mm x 60mm x 1.25mm thick, with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete as specified and as directed.
S&F 35 mm thick, second class hard wood glazed and skeleton shutters, factory made, open rebated and prepared to receive glass, gauze, etc., divided in to squares with plain, chamfered or rounded mitred and rebated sash bars any numbers, edges of framing plain, chamferesd or rounded, fitted with cut and mitred beads for securing glass etc., for windows and ventilators, etc are provided with stiles and rails as specified in SSR Pt I Section 8, clause 8.24 (a) complete all as specified and as directed.
S&F 35mm thick, second class hard wood, plain framed, factory made, panelled shutter (two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated all as specified and as directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reiforced with mild steel square tube , supplying & fixing in opening as per specifications all as specified and as directed.
S&F fatory made solid panel PVC door shutter, 30mm thick (stiles), consisting of frame made out of mild steel tubes for top and bottom rails mild steel frame shall be covered with heat moulded feathered edges plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struk inside with solvent cement for stiles and plain colour feathered edges PVC sheet for top rail,lock rail and bottom rail on either side & as gap insert for top rail & bottom rail, panneling of plain colour PVC sheet to be fitted in the mild steel frame welded /sealed to the stiles & rails with suitable for feathered edges PVC sheet, and jointed together with solvent cement, suppling and fixing in the frame at site as per specifications & drawing complete all as specified and as directed.
S&F 150 mm size aluminium anodised, barrel tower bolts of extruded section and fixed all as specified and as directed.
S&F 250 mm long aluminum alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of steel, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy complete all as specified and as directed.
S&F 100 mm size butt hinges medium weight, stainless steel and fixed all as specified and as directed.
S&F 150mm size aluminium anodised handle, extruded section complete all as specified and as directed.
M&L for preparation of new wood or wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.
S&F mild steel windows, side hung, including projecting type hinges with steel handles and steel peg stay complete with glazing bars dovetailed or welded complete all as specified and as directed.
S&F mild steel windows, side hung, including projecting type hinges with steel handles and steel peg stay complete without glazing bars dovetailed or welded complete all as specified and as directed.
S&F mild steel ventilators, fixed type with glazing bars all as specified and as directed.
S&F mild steel framed work such as grills, framed guard bars and similar work conforming to Fe-290.Gde-E-165, welded to steel ventilators & window complete all as specified and as directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aparture 1.40 mm, fixed with stainless steel wire staples to steel / wooden frame complete all as specified and as directed.
S&F 3mm thick frosted/figured glass, pin headed type and glazing with oil putty in square not exc 0.5Sqm in each pane and fixed to steel windows including glazing pins etc. complete all as specified and as directed.
S&F 3 mm thick plain sheet glass and glazing with oil putty in square not exc 0.5 Sqm in each pane and fixed to steel windows including glazing pins etc. complete all as specified and as directed.
M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified and as directed.
M&L for 20mm bore GI tubing, medium grade with all fittings and fixed complete on walls and ceilings or laid in floors etc complete all as specified and as directed.
S&F 15mm UPVC pipes of pressure rating 10 Kgf/sqcm fixed complete to wall, ceilings or in floors etc all as specified and as directed.
Cutting chases n. exc 10 cm in girth, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing etc complete all as specified and as directed
S&F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top), 500 litres capacity, tripple layered, hoisted and fixed in position including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to iron pipe and connecting all as specified and as directed.
All as per serial item No 79 above but 1000 ltr capacity with 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball.
S&F bib tap, 15mm dia, cast copper alloy chromium plated, fancy type with capstan head screwed down for iron pipe or for brass ferrule complete all as specified and as directed.
S&F brass crominium plated wall mixer for mixing hot and cold water and bend for connecting to shower, screwed down for iron pipe 15 mm bore and fixed complete all as specified and as directed.
S&F stop valves/angle valve, 15mm dia, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with capstan head, screwed both ends for iron pipe or unions complete all as specified and as directed.
S&F stop valves/ angular stop valve, 20mm dia, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with capstan head, screwed both ends for iron pipe or unions complete all as specified and as directed.
S&F 110 mm bore, PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixd to wall or laid in trenches or in floors all as specified and as directed.
S&F PVC (SWR) pipes 75 mm dia single socketed in any length with rubber ring joints fixed to walls or laid in floors complete including clamps for securing pipe complete all as specified and as directed.
S&F 110 mm dia PVC (SWR) bends of any radius complete all as specified and as directed
S&F PVC (SWR) 110mm dia in junction single, (Single T) equal or unequal complete all as specified and as directed.
S&F PVC (SWR) 75mm dia in junction single, (Single T) equal or unequal
S&F 110 mm dia PVC (SWR) bends with access door of any radius, complete all as specified and as directed
S&F PVC (SWR) 110 mm bore vent cowl all as specified and as directed
M&L for PVC (SWR) floor trap with dia of outlet 75mm, plain with grating including jointing with solvent cement to waste pipe fixed in cement concrete type (1:2:4) type B1 using 20mm graded stone aggregate all as specified and as directed.
M&L for PVC (SWR) multi floor trap with dia of outlet 75mm, plain with grating including jointing with solvent cement to waste pipe fixed in cement concrete type (1:2:4) type B1 using 20mm graded stone aggregate all as specified and as directed.
S&F Chromium plated health faucet (hand shower) with 8mm dia, 1200 mm long flexible tube, wall mounted / hooked all as specified and as directed.
S&F chromium plated shower rose with or without swivel joints, 125mm size, including fixing to steel pipe or union etc complete all as specified and as directed.
S&F Aluminium anodised tubular towel rail 600mm long between the flanges and 20mm dia complete all as specified and as directed.
S&F vitreous China, white, squatting pan, Orissa pattern of size 580 X 440 mm width with integral foot rest, set in cement concrete including flush pipe and connecting to trap with and including 10 ltr capacity PVC valveless syphonic action type flushing cistren low level, white or coloured, with inlet, ball valve, float and handle including brackets, including PVC connections 15mm dia with PTMT nuts of length 450mm and making good to floor complete all as specified and as directed.
S&F vitreous china wash down water closet (Pedestal pattern) including connection to drain (or outgoing pipe) with and including 10 ltr capacity PVC valveless syphonic action type, flushing cistren low level, white or coloured, with inlet, ball valve, float and handle including brackets, including PVC connections 15 mm dia with PTMT nuts of length 450mm trap set and including white or black seat cover for pedestal pan with mild steel chromium plated aluminium hinging device, fixed to pan with suitable screws etc complete all as specified and as directed.
S&F vitreous china wash hand basin, white flat back of size 550 mm x 400 mm including brackets with and including pillar tap, 15 mm bore chromium plated, fancy type, cast copper alloy with capstan head, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks, 32 mm waste coupling brass chromium plated suitable for wash hand basins, with long screwed shanks and fly nuts and PVC waste pipe15mm dia, PVC connection pipe 450mm long complete all as specified and as directed.
M&L for vitreous China bowl urinal flat back of size 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe) with and including urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) including PVC connection 15mm bore and 450mm long , 40mm PVC waste pipe & 40 mm waste coupling providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plug, with and including 60mm long screws, pointing around urinal back in cement, fixing flush pipe, complete all as specified and as directed.
M&L for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and as directed.
M&L for PCC 1:4:8 type D-2, using 40 mm graded stone aggregate as in concrete bed to drain pipes, any type, 150 mm internal dia including packing under and haunching against the sides of the pipes after they are laid & tested complete all as specified and directed.
M&L for 150 mm bore reinforced concrete pipes of approved make , class NP2, laid and jointed complete with collars complete all as specified & as directed. Notes:- (a) Before laying the pipes, the site of work shall be approved GE. (b) Purchase vouchers of RCC pipes shall be produced at the time of payment duly verified.
M&L for cutting into existing manhole for connecting new drains, making good to pipes & rendering, cutting out existing benching & forming branch channel 1, ½ round or ¾ section in PCC 1:2:4 type B1, smooth finished for 150 mm bore pipe complete all as specified and as directed.
M&L for point wiring complete, concealed type with two runs of 1.5 sqmm for phase and neutral single core multistranded copper conductor cable of 1100 Volts grade PVC insulated and unsheathed, FRLS cable drawn through and including PVC rigid conduit not less than 20 mm dia with its accessories (ISI marked) and PVC box and fixed with brass screws, cup washer for mounting switches, sockets, fan regulators etc with and including 1.5 Sqmm copper conductor cable (multistranded) PVC insulated and unsheathed FRLS cable as earth wire connected to common earth dolly at one end and metalic bodies of luminaire/ fan at other end all as specified and as directed for One light point and one fan point controlled by one, one way swtich. NOTES: (a) Proper colour coding shall be adopted for wiring (for Phase- RED, YELLOW, BLUE for Earth - Green and Neutral - Black. (b) All points shall be earthed up to fixtures i.e holdrs, tube lights all lights, ceiling lights, bldg security lights etc.
All as per serial item No. 106 above but one 6 Amp 5 pin socket outlet point on same board with other switches including earth wire as specified and as directed.
All as per serial item No. 106 above but on independent board.
All as per serial item No. 106 above but with 2.5 Sqmm, PVC copper stranded cable FRLS type for phase, neutral and earth for one 16 Amp, 6 pin socket on independent board.
M&L for switch piano flush button 6 Amp single pole one way 230 volts white finish all as specified & as directed.
S&F socket outlet flush type 3 pin 6 Amp multipurpose 230 volts single pole one way suitable for 3 pin/ 2pin 6 Amp plug top white/ivory finish all as specified & as directed.
S&F switch socket combination, flush type, 3 pin, 6 Amp, multipurpose, 230 volts, single pole, one way, suitable for 3 pin/2 pin 6 Amp plug top white/ivory finish all as specified & as directed.
S&F switch socket combination, multipurpose, flush type, 2 in 1 type (6 pin ) 6/16 Amps, 230V, AC all as specified & as directed.
S&F ceiling rose surface type, PVC, 50mm dia, 3 terminals including PVC mounting block white/ivory finish all as specified & as directed.
S&F square profile LED lighting fixture with extruded polycorbonate, environmental friendly, energy efficient ready to use pack LED tube light fitting, 20 Watt with LED light source 6500k with uniform light output with all accessories including its connection from ceiling rose to light fittings complete with all as specified and as directed. Make : HAVELLS LED PRIDE ESSENTIAL Cat No LHEXAWP71N1W020 or equivalent model of makes as specified and as approved by GE.
S&F sheet metal enclosure (Factory made), double door shutter type for distribution board (when MCBs are to be used), single pole and neutral, 240 volts, 8 way, protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming as per IEC 61439-3, suitable for flush mounting and surface mounting with 200 Amps rated copper busbar, with neutral bar, earthbar and cable alley for cable managment, fully shouldered, neutral bars, prefittes masking sheet complete all as specified and as directed.
S&F MCB SP, AC 240 V,6 to 32 Amps 10 KA capacity,'C' series making connection with suitable size of copper lugs etc complete all as specified and as directed.
S&F MCB TPN, AC 240 V, 40 Amps 10 KA capacity, 'C' series making connection with suitabl size of copper lugs etc complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm thick, buried directly in ground earth pit not less than 2.25 meter in depth with top edge of the plate not less than 1.5 meter below normal ground level, connected to galvanized iron wire 4 mm dia earthing lead by means of bolts, nuts, check nuts and washers etc. Earth wire connected upto main earth point/DBs alongwith 15mm dia earth protection pipe from top edge of earth plate to main earth point to be connected and 20 mm bore medium grade GI tubing watering pipe with funnel and provision of PCC using cement concrete (1:2:4) mix type B1 (using 20 mm grade stone aggregate ) and RCC pit cover 50 mm thick precost RCC (1:2:4) mix type B1 duly reinforced with 8 mm dia of mild steel bars @ 15 mm centre to centre with both way lifting arrangement complete including all necessary excavation & earth work etc complete all as specified and as directed.
S&F metallic exhaust fans, AC, single phase, 230/240 volt of size 300 mm sweep with blades, frame, louver with and including making hole and making good the surface as per existing finish complete all as specified and as directed.
S&F security light of building with single piece, new generation energy saving and environmental friendly long life LED 35W made up of pressure die cast aluminium housing with acrylic covers as diffuser with IP66 protection and impact resistance of IK07 including one bracket made of Light grade GI Pipe 25 mm dia 1.5 mtr long fixed to wall/ pole with two clams made out of MSFI 40 mm x 5 mm and connect to nearest electric supply by three core 1.5 sqmm aluminium cable all as specified and as directed. Make : Havells Cat No ENDURACITYLITEPLAT PLUSSL35WLED757SASYBOPC or equivalent model of makes specified.
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep minimum air delivery 210 CFM with five star rated with brushless direct current motor (BLDC) all as specified and as directed.
Supply, installation, testing and commissioning of vertical water heater storage type steel body with copper inner tank and heating element upto 2 KW of capacity 25 litres,BEE 5 star rated AC, 50 Hz, 230 Volts complete with thermostate, temperature control knob, NRV, safety valve, inlet and outlet ports, connection piece and all acessories and connections complete all as specified and as directed.
M&L for double walled corrugated (DWC) HDPE Pipe of 50mm bore including 90 degree bends with coupler and rubber ring, with all accessories, laid in trenches suitable for LT cable protection all as specified and as directed .
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core all as spesipied and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 3.5 core all as specified and as directed.
M&L for 40mm GI tubing, medium grade laid in trenches / floors or fixed to wall in any length with screwed and socket joints together with all galvanised GI fitting such as sockets, bends, elbows, tees, reducers, unions, jointing materials etc and pressure testing, washing out complete all as specified and directed.
M&L for 25mm GI tubing medium grade laid in trenches / floors or fixed to wall in any length with screwed and socket joints together with all galvanised GI fitting such as sockets, bends, elbows, tees, reducers, unions, jointing materials etc and pressure testing, washing out complete all as specified and as directed.
M&L for 40mm gun metal or bronze globe/gate valve, ISI marked, screwed both ends suitable for GI tubing with side way operating GI lever handle complete all as specified and as directed.
M&L for 25mm gun metal or bronze globe / gate valve, ISI marked, screwed both ends suitable for GI tubing with side way operating GI lever handle complete all as specified and as directed.
M&L for cutting/ drilling existing pipe line & taking branch connection complete including all necessary GI fittings, jointing materials, excavation and earth work etc complete all as specified and as directed.
DHANANJAY BABAN KALANE (BID ID -3120525)
M/s Meher Construction (BID ID -3124251)
AMAR CONSTRUCTION (BID ID -3123419)
NATHKRUPA CONSTRUCTION (BID ID -3123881)
M/s Mauli Construction (BID ID -3123440)
Poojan Infra and Developers (BID ID -3123472)
MATOSHREE CONSTRUCTION (BID ID -3123826)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .