| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 LAdmitted-Finance | ₹2.8 L | L1 | Admitted-Finance |
| 2 | L2₹2.9 LAdmitted-Finance | ₹2.9 L | L2 | Admitted-Finance |
| 3 | L3₹3.0 LAdmitted-Finance | ₹3.0 L | L3 | Admitted-Finance |
| 4 | L4₹3.1 LAdmitted-Finance | ₹3.1 L | L4 | Admitted-Finance |
| 5 | L5₹3.2 LAdmitted-Finance | ₹3.2 L | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M.O.S ELECTRICALS L4 | SOWELL AGENCIES L2 | Jaima Electricals L1 | M/S SHANDAR ENTERPRISES L5 | AKHTAR ELECTRICALS L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Refilling / topping up of Transformer oil of as found necessary during inspection of the Transformer Substation including carriage as per site requirement. | 500 | Ltrs. | 180 ₹90,000 | 168 ₹84,000 | 155 ₹77,500 | 185 ₹92,500 | 175 ₹87,500 |
| 2.00 | Replacement of the damaged/ faulty Servo motor 10 Kg-cm torque found faulty during inspection of AVR including dismantling old and Supplying, installing of new one complete with testing and commissioning of AVR as per site requirement. | 3 | Nos. | 3,250 ₹9,750 | 3,000 ₹9,000 | 3,000 ₹9,000 | 3,300 ₹9,900 | 3,200 ₹9,600 |
| 3.00 | Replacement of the damaged/ faulty Control Card found faulty during inspection of the AVR including dismantling old and Supplying, installing of new one complete with testing and commissioning of AVR as per site requirement. | 5 | Nos. | 3,000 ₹15,000 | 2,800 ₹14,000 | 2,700 ₹13,500 | 3,100 ₹15,500 | 2,800 ₹14,000 |
| 4.00 | Replacement of the damaged/ faulty Dimmer Coil (Variac) 200 A rating found faulty during inspection of the AVR including dismantling old and Supplying, installing of new one complete with testing and commissioning of AVR as per site requirement. | 2 | Nos. | 45,000 ₹90,000 | 40,000 ₹80,000 | 40,000 ₹80,000 | 45,000 ₹90,000 | 41,750 ₹83,500 |
| 5.00 | Replacement of the damaged/ faulty Buck Boost Transformer 15 KVA rating found faulty during inspection of the AVR including dismantling old and Supplying, installing of new one complete with testing and commissioning of AVR as per site requirement. | 2 | Nos. | 25,000 ₹50,000 | 24,250 ₹48,500 | 24,000 ₹48,000 | 24,500 ₹49,000 | 23,950 ₹47,900 |
| 6.00 | Replacement of faulty 3 pole Power Contactor suitable for 415 v, 3-phase ,50 Hz, AC supply of AC1 rating of 160 Amp (MNX 110 of L&T make or similar model of superior make) complete with removing faulty and supplying and fixing of new one complete as required ( BSNL approved makes) | 2 | Nos. | 22,500 ₹45,000 | 21,000 ₹42,000 | 20,500 ₹41,000 | 23,000 ₹46,000 | 20,550 ₹41,100 |
| 7.00 | Replacement of damaged/ faulty 200 A, 415 V, Four Pole, On load, type Changeover switch in open execution in existing panel suitable for operation on 3-Phase, 50 Hz supply complete with removal of faulty and S/F of new Changeover switch including interconnections , complete as required (BSNL Appd. Makes). | 1 | No. | 15,000 ₹15,000 | 13,750 ₹13,750 | 14,000 ₹14,000 | 15,000 ₹15,000 | 13,900 ₹13,900 |
Tender Value
₹2.8 L
EMD Value
₹5,555
Closing Date
13 Mar 2026, 6:00 pmClosed
EE EP BSNL JAMMU
kindly refer NIT document
SPECIAL REPAIRS OF AVR AT TE BLDGS KISHTWAR AND DODA IN OA UDHAMPUR.
2026_BSNL_268509_1
63/CPPP/EE(EP)/SE (E)/BSNL/JMU/2025-26
Open Tender
Electrical Works
30 days
UDHAMPUR
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
Yes
AO CASH O/O CGM BSNLJAMMU
₹5,555
Yes
16 Mar 2026
24 Feb 2026
16 Mar 2026
24 Feb 2026
13 Mar 2026
24 Feb 2026
Refilling / topping up of Transformer oil of as found necessary during inspection of the Transformer Substation including carriage as per site requirement.
Replacement of the damaged/ faulty Servo motor 10 Kg-cm torque found faulty during inspection of AVR including dismantling old and Supplying, installing of new one complete with testing and commissioning of AVR as per site requirement.
Replacement of the damaged/ faulty Control Card found faulty during inspection of the AVR including dismantling old and Supplying, installing of new one complete with testing and commissioning of AVR as per site requirement.
Replacement of the damaged/ faulty Dimmer Coil (Variac) 200 A rating found faulty during inspection of the AVR including dismantling old and Supplying, installing of new one complete with testing and commissioning of AVR as per site requirement.
Replacement of the damaged/ faulty Buck Boost Transformer 15 KVA rating found faulty during inspection of the AVR including dismantling old and Supplying, installing of new one complete with testing and commissioning of AVR as per site requirement.
Replacement of faulty 3 pole Power Contactor suitable for 415 v, 3-phase ,50 Hz, AC supply of AC1 rating of 160 Amp (MNX 110 of L&T make or similar model of superior make) complete with removing faulty and supplying and fixing of new one complete as required ( BSNL approved makes)
Replacement of damaged/ faulty 200 A, 415 V, Four Pole, On load, type Changeover switch in open execution in existing panel suitable for operation on 3-Phase, 50 Hz supply complete with removal of faulty and S/F of new Changeover switch including interconnections , complete as required (BSNL Appd. Makes).
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.62 MB
TENDER63.pdf
Tender Documents • 1.60 MB
BOQ_312503.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid