Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC CHENNAI | CHENNAI | TAMIL NADU | 600001 | L1 | Accepted-AOC Admitted | |
| 2 | L2₹20.0 L+₹1.2 L (6.57%)Rejected-Finance E 27 CWE WELLINGTON | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L2 | Rejected-Finance Not being the lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹35,200
Closing Date
3 Jul 2021, 6:00 pmClosed
GE Wellington
Garrison Engineer Wellington Barrack Post Nilgiris Pin code-643231
PROVISION OF GUARD ROOM WITH TOILET BLOCK NEAR BLDG XLIII AT KILIMANJARO HALL OF MRC AND PROVISION OF URINALS WC AND WHB FOR JCOS OR NEAR BLDG NO I RECORDS OF MRC WELLINGTON UNDER GE WELLINGTON
2021_MES_421214_3
8625/E8
Open Tender
Civil Works
Item Rate
180 days
Wellington
As per Tender Documents
4 documents required · 4 mandatory
₹500
GE Wellington
₹35,200
Yes
27 Aug 2021
9 Jun 2021
5 Jul 2021
10 Jun 2021
3 Jul 2021
10 Jun 2021
Amount
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sq m on plan and not exceeding 1.5 m in depth and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each, back in trenches after cable have been laid and tested, poles stays, struts have been erected and tested complete all as specified and directed.
Removing excavated surplus soil to a distance exceeding 100m and not exceeding 250m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
Anti termite treatment to backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) all as specified and directed.
Anti Termite treatment to the top surface of filled earth at the rate of 5 litres of emulsion per square meter of surface area complete all as specified and directed.
Anti Termite treatment to soil under plinth protection at the rate of 5 litres of emulsion per square meter of surface area complete all as specified and directed.
Anti Termite treatment to soil along with external perimeter of building at the rate of 2.25 litres of emulsion per square meter of perimeter wall complete all as specified and directed.
Plain cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concreting, complete all as specified and directed.
Use and waste of formwork to sides of concrete foundations, footings, base of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work; vertical or to batter flat surface rough finished complete all as specified and directed.
Reinforced cement concrete (nominal mix) Type B1, 1:2:4 using 20 mm graded stone aggregate as in foundations, including rafts, footing, foundations, beams, plinth beams, bases for columns, etc., basement slabs, under reamed piles and mass concrete etc complete all as specified and directed.
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions with rough finished surface of concrete complete all as specified and directed.
Reinforced cement concrete (nominal mix) Type B1, 1:2:4, using 20mm graded stone aggregate as in columns, pillars, piers, posts and struts all as specified and directed.
Use and waste of form work to sides and bottom of beams with rough finished surface of concrete complete all as specified and directed.
Reinforced cement concrete (nominal mix) Type B1 1:2:4 (using 20mm graded stone aggregate) for beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and directed.
Use and waste of formwork for fair finished surface to soffits of suspended slabs such as roof slabs and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed
Reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roof, landing, deck slab and in shelves and the like all as specified and directed
Use and waste of formwork for fair finished surface of chajjas, trough, fin and similar items including edges all as specified and directed.
Reinforced cement concrete (nominal mix) Type B1, 1:2:4, using 20mm graded stone aggregate for chajja, fin complete all as specified and directed.
Use and waste of form work to edges of concrete flats, treads, breaks in floor, window cills, concrete railing, openings in concrete walls, floor and roof not exceeding 20cm wide and sides of RCC / PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide all as specified and directed.
Rendering 10mm thick in cement mortar 1:3 with WPC laid over RCC roof slab all as specified and directed. Note: WPC will be measured and paid separately.
APP modified prefabricated five layer water proofing membrane mineral finish 4mm thick and weighing not less than 4.5 kg/sqm reinforced with non-woven polyester matt black finished weighing not less than 100 gm/sqm having softning not less than 140 degree celcius longitudinal tensil strength not less than 300N/sqcm, side lap 10cm with torch application of membrane over compatible primer at 0.40 Ltr/sqm and aluminium paint at 0.10 kg/sqm on top complete all as specified and directed.
Pre-cast cement concrete block masnory with solid block exceeding 10cm in width and setting in mortar 1:6 type C1 1:3:6 using 20mm graded aggregate complete all as specified and directed
Pre-cast cement concrete block masnory with solid block exceeding 10cm in width and setting in mortar 1:6 type C1 1:3:6 using 20mm graded aggregate complete (with plain or interlocking joints as directed) setting in motar, complete walls built all as specified and directed
Forming fair finished drain or channel of 30cm inner girth in cement concrete using extra cement including forms, moulds etc complete all as specified and directed.
Damp proof course 40mm thick in cement concrete 1:2:4, type B0 using 12.5mm graded stone aggregate to horizontal or vertical surfaces including necessary formwork and applying evenly a coat of blown type bitumen at the rate of 1.50 Kg per square meter and blinding with clean dry sand @ 0.05 cu.m per sqm over polythene film 50 micron thick, laid on a coat of bitumen primer @ 0.30 to 0.50 Kg/Sqm all as specified and directed.
Plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in flooring 40mm thick with chequered finish all as specified and directed.
Plain cement concrete 1:2:4 type B-1 using 20mm graded aggregate for benching including weathering slightly rounded or chamfered angles and throating etc including necessary form work all as specified and as directed.
Rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Rendering 15mm (5mm thick in cement mortar 1.4 with WPC over a coat of 10mm thick in cement mortar 1:6) on other than fair faces of brick work or concrete surface including finished even and smooth without using extra cement all as specified and directed.
Rendering in cement mortar 1:3, 5mm thick as in RCC surfaces such as sides of columns, beams etc including finishing the surfaces even and smooth without using extra cement all as specified and directed.
Supply only water proofing compound all as specified and directed.
Rendering in cement mortar 1:3, 5mm thick as in ceiling surfaces including finishing the surfaces even and smooth without using extra cement all as specified and directed.
Forming V grooves in plaster not exceeding 10mm deep all as specified and directed.
Applying three coats of white wash on ceiling surfaces over a coat of 3mm thick wall care putty in two layer (1.5mm each layer) on newly plastered wall surface including preparation all as specified and directed.
Applying two coats of oil bound distemper over a coat of primer over a coat of 3mm thick wall care putty in two latyer (1.5mm each layer) on newly plastered wall surface including preparation all as specified and directed.
Applying two coats of cement based paint, over a coat of alkali resistant primer including preparation of newly plastered surfaces complete all as specified and as directed.
Mild steel TMT bars 10mm dia and over cut to length, bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
All as per item No 37 hereinbefore but 5mm dia and over upto and including 10 mm dia in stirrups, spacers and binders all as specified and directed.
Plain cement concrete 1:5:10 type E-2 using 40mm graded aggregate in sub base 75mm thick all as specified and directed.
Plain cement concrete 1:2:4 type B-0 using 12.5mm graded aggregate in floor 20mm thick all as specified and directed.
Coloured non - skid Ceramic tiles 7 to 8 mm thick (Square / Rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including Screed bed or bedding layer 15mm thick for laying floor finishes in CM 1:4 complete all as specified and as directed.
All as per item No 41 hereinbefore but in skirting including coat 10mm thick in cement mortar 1:3 all as specified and as directed.
Coloured Non skid ceramic tiles matt finish 7mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of mortar 15mm thick in cement mortar 1:4 complete all as specified and directed.
Coloured Glazed ceramic tiles in vertical surfaces 450 x 300 x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick backing coat in cement mortar 1:3 complete, complete all as specified and directed.
PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube all as specified and as directed
Factory made solid panel PVC door shutter 30mm (Stile) consisting of frame made out of M.S tubes for top and bottom rails M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheets to be fitted in the M.S frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame all as specified and directed.
Pressed steel frames of size 165mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and directed
35mm thick second class HW plain, framed, panelled shutters (any No of panels) with panels of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face veneers supplied and fitted to chowkats all as specified and directed.
30mm thick second class HW glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkat all as specified and directed.
Box type steel windows/ ventilators frame with glazed and fly proof shutter including MS guard bar including all fittings all as specified and directed.
Box type steel windows/ ventilators frame with shutter including MS guard bar and all fittings all as specified and directed.
PCC 1:2:4, type B-0 using 12.5 mm graded stone aggregate as in coping, bed block, for embedding hold fast and similar work including necessary form work complete all as specified and directed.
4 mm thick figured glass, pin head type and glazing with oil putty in squares not exceeding 0.5 sq. m in each pane all as specified and directed.
4 mm thick sheet glass ordinary quality and glazing with oil putty in squares not exceeding 0.5 sqm in each pane all as specified and directed.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless wire staples complete all as specified and directed.
Applying two coats of synthetic enamel paint over new wooden surfaces of any description not otherwise described over 10cm in width or girth over a coat of pink primer including preparation of surface complete all as specified and as directed.
Granite black 20mm thick table rubbed and polished in steps, window cills, cooking platforms and like in single piece set in neat cement slurry and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite all as specified and as directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations all as specified and directed.
Preparation of new or untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer all as specified and directed.
Aluminium anodised, barrel tower bolts of extruded section 150 mm long all as specified and directed.
Aluminium anodised, barrel tower bolts of extruded section 200 mm long all as specified and directed.
300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
Butt hinges, 100 mm size medium weight, cold rolled mild steel, and fixed complete all as specified and directed.
Aluminium butt hinges 100mm size all as specified and directed.
Aluminium handles, cast type, anodised 100 mm long complete all as specified and directed.
Aluminium handles, cast type, anodised 150 mm long complete all as specified and directed.
Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring of 140mm overall all as specified and directed.
Brass hat and coat hooks, solid body, 175mm to 250mm complete all as specified and directed.
Harrison rails, mild steel, chromium plated including fixing with brackets, stops, rollers etc all as specified and directed.
PVC (SWR) pipe 160mm bore as in half round gutters including fixing with PVC clamps suitable for Non AC sheet roof, complete all as specified and as directed.
PVC 160mm dia drop ends / stop end suitable for 180mm half round valley gutter complete all as specified and as directed.
PVC (SWR) 160mm dia bore pipe single socketed in any length, with rubber ring joint fixed to walls with PVC clamps complete all as specified and directed.
PVC (SWR) bend of any radius 160 mm dia all as specified and as directed.
Vitreous china squatting pan, Orissa pattern of size 580 x 440mm (white coloured) with integral foot rests (excluding flushing cistern and flush pipe) with P or S trap portion to match with existing surface of floor and fixed in repairs all as specified and directed.
PVC flushing cistern 10 litres capacity high level including ball valve inlet and outlet connection 15mm dia PVC pipe with check nut on both ends, PVC waste pipe 32mm upto WC connection and GI 15mm dia overflow pipe upto floor level all as specified and directed.
PVC connections 15 mm size with PTMT nuts of length 750mm all as specified and directed.
Bib taps,15 mm, fancy type,cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule all as specified and as directed.
Pillar taps, 15mm bore, fancy type ,cast copper alloy with capstan heads, chromium plated, screwed down high pressure, screwed for iron pipe and fixed all as specified and directed.
Stop valves cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed fancy type chromium plated ,15mm bore all as specified and directed.
Brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges all as specified and directed.
Soap dish, chromium plated 100x100x60mm fixed to wall with plugs with chromium plated screw complete all as specified and directed.
Vitreous china wash basin, white flat back size 550 X 400 mm including cutting for and pinning in ends of brackets or erecting stand but exclusive of taps, fixing of supply and waste pipe complete all as specified and directed.
PVC waste pipe of 32/40mm bore suitable for wash hand basin/ urinal all as specified and directed.
Vitreous china half stall bowl urinal flat back, size of 465 x 355 x 265mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) all as specified and directed.
Urinal spreader of PTMT any colour for fixing with 15mm dia pipe (Minimum weigth 60gms) all as specified and directed.
PVC (SWR) bend of any radius 110 mm dia with access door complete all as specified and as directed.
PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints laid in trenches or in floors all as specified and as directed.
Bands, straps, supports or stays for rainwater, ventilating pipes including bolts, if requried hooks (stay), heavy for large gates, hook and pintle hinges, large hasp and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe 290 Gde E-165 all as specified and as directed.
PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement all as specified and as directed.
PVC (SWR) junction single, (single T) equal or unequal of 110mm bore of pipe complete all as specified and directed
PVC (SWR) junction single, (single T) equal or unequal of 75mm bore of pipe complete all as specified and directed
PVC (SWR) vent cowl 110mm dia bore of pipe complete all as specified and directed.
PVC (SWR) vent cowl 75mm dia bore of pipe complete all as specified and directed.
PVC (SWR) 75mm dia bore pipe single socketed in any length, with rubber ring joint fixed on wall with PVC clamp complete fixed in repairs all as specified and directed.
75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
Precast RCC (1:2:4) type B1 using 20 mm graded stone aggregate in landings, cover slabs (for manhole etc) chullah hoods, chajjas, water trough,mangers, sheles and similar articles with plain faces set in cement mortar 1:4 complete all as specified and directed.
Hard core of gauge not exceeding 63 mm, deposited, spread and leveled in layers not exceeding 15 cm thick watered and rammed to a true surface of broken stone / boulders complete all as specified and directed.
75mm thick plain Cement concrete type C-1 , 1:3:6, using 20 mm graded stone aggregate as in plinth protection all as specified and directed.
Forming 12mm thick Expansion joints filled with Pre-formed bitumious filler and top 30mm primed and sealed with sealing compound Grade 'A' all as specified and directed.
Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) three layers of capacity 500 Ltr hoisted and fixed in position with proper inlet and outlet connections all as specified and directed.
PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) all as specified and directed.
GI pipe 15mm dia medium grade with all fittings fixed on wall, ceiling or laid in floors complete all as specified and directed.
GI pipe 20mm dia medium grade with all fittings fixed on wall, ceiling or laid in floors complete all as specified and directed.
Gun metal gate valve with iron wheel head screwed both ends for iron pipe of size 20mm dia all as specified and directed.
Ball brass valve high pressure with polythene float and fly nut complete, screwed for iron pipe or for brass ferrule and fixed of 20mm dia all as specified and directed.
Rough excavation not exceeding 1.5m deep and getting out as in soft / loose soil and all as specified and directed.
Broken stone / boulders loose filling with aggregates of gauge 40 to 80 mm in back of walls complete all as specified and directed.
Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 and pointing the dressed surface with same mortar as the work proceeds all as specified and directed.
Plain Cement concrete type C-1, 1:3:6 using 20mm graded stone aggregate as in copings including necessary form work all as specified and directed.
Hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought up to courses with maximum depression on face from straight edge held against the dressed surface not exceeding 40mm all as specified and directed.
Keyed pointing to random or polygonal rubble masonry uncoursed or brought upto courses in cement mortar (1:4) all as specified and as directed.
On site Hume pipe septic tank designed to carry sewage and suldge water, excavation and returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc, complete for 10 users (As per CECZ TD No.666 Sheet No 1/1 dt 03-08-2007) all as specified and as directed.
Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6 walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of block masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC / DWC complete filled with brick bats of size 1.2M dia x 1.5M effective depth (As per CECZ TD/ ST No 746 sheet No 1/1 dt 22-01-2011)
Plain cement concrete as in haunching for manhole, floor, surface channels and drains of type B2, 1:2:4 using 40mm graded stone aggregate complete all as specified and directed.
Reinforced Concrete pipes class NP-2 laid and jointed complete with collars of 150mm dia all as specified and directed.
Concrete bed to drain pipes including packing under and haunching against the sides of the pipes after they are laid and tested in cement concrete 1:4:8 type D-2 using 40mm graded aggregate for 150mm dia size pipe all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Dismanting of Mangalore pattern tiles or similar pattern tiles on roof complete all as specified and directed.
Dismantling of timber scantling 40 sqcm and over in sections in any position in unframed works all as specified and directed.
Dismantling of timber scantling, unframed in post, rafters, purlins etc under 40 sqcm in section all as specified and directed.
Dismantling battens for tiles, shingles etc, of any size including tilting fillets spaced exceeding 15cm all as specified and directed.
Demolition of Brickwork, stone / boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Demolition of Concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) all as specified and directed.
Taking down chowkat or frame with shutter (without taking off shutters from the frame) area not exceeding 1.5 Sq mtr each and removing from site including making good to disturbed jambs complete all as specified and directed.
Taking down chowkat or frame with shutter (without taking off shutters from the frames) area exceeding 1.5 Sq mtr but not exceeding 4 Sq mtr each and removing from site including making good to disturbed jambs complete all as specified and directed.
Surface excavation not exceeding 30cm deep and averaging 15 cm deep and getting out as in hard/ dense soil complete all as specified and directed.
Removing excavated soil/ material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Providing Precast cement concrete for lintels RCC type B1, 1:2:4 (nominal mix) using 20mm graded stone aggregate set in cement mortar 1:4 complete all as specified and directed.
Plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base to floor 100mm thick all as specified and directed.
25 mm thick Plain cement conncrete 1:2:4, type B-0 using 12.50mm graded crushed stone aggregates as in sub base of floor surface finished even and fair complete all as specified and directed.
Chequred cement concrete coloured tiles having hard rubber finish top with polymer admixtures in any pattern or design of minimum size 30cm x 30cm x 25mm thick, set jointed and pointed in neat cement slurry in floors over 15mm thick screed bed in cement mortar 1:4 all as specified and directed.
Aluminium butt hinges 150mm size all as specified and directed.
Anodised aluminium frame powder coated for doors, windows ventilators, U channels safety grill with one or more rebates including joining cleat for fixing complete all as specified and directed.
Anodised aluminium window and ventilators shutters, side hung type without sash bars, aluminium sections weighing 0.55 Kg/m including necessary joining cleats glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No) hinges type B-21 100mm long (2 Nos) suitable handle (1 No) complete all as specified and directed.
Supply and Fix 3mm thick figured glass, pin head type and glazing with oil putty in a square not exceeding 0.5 Sq m in each pane all as specified and directed.
Vitreous china wash down water closet (pedestal pattern) white (excluding flushing cistern and flush pipe) including seat cover, trap and connection to drain and flush pipe complete all as specified and directed.
Mild steel works in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle) including distance pieces, cleats etc.of grade Fe-410-W (Gde-E-250) quality-A all as specified and directed.
Pre- painted galvalume aluminum zinc coating GI based Plain steel sheet as in ridge of 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering and on chajjas fixed with self tapping screws all as specified and directed.
Mild steel Framed work such as grill, grating etc with ends of bars shouldered and /or riveted or forged into spikes, framed guard bars, barred iron door, ladders, framed balusters and simialr work conforming to Fe290 Gde E-165 all as specified and directed.
Excavating in post holes (or similar holes) each in soft /loose soil not exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removal of excavated materials to a distance not exceeding 50mtr and making good surfaces, complete all as specified and directed
PVC (SWR) 110mm dia bore pipe single socketed in any length, with rubber ring joint fixed to walls with PVC clamps complete all as specified and directed.
PVC (SWR) bends 110mm bore any radius, complete all as specified and directed.
PVC (SWR) bend of any radius 75 mm dia complete all as specified and as directed.
Health faucet with flexible tube fancy type including all fittings complete all as specified and directed.
PVC connections 15mm size of length 450mm with PTMT nuts all as specified and directed.
Cutting into existing manholes for connecting new drains of 150mm / 120mm internal dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate smooth finished and reforming benching as required complete all as specified and directed.
Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) three layers of capacity 1000 Ltr hoisted and fixed in position with proper inlet and outlet connections all as specified and directed.
Cutting and tapping of existing 50mm pipe and inserting a Tee for new connection of size 25mm including reducers requred if any complete all as specified and directed.
Steel water tubing medium grade galvanized with all fittings and laid in trenches of size 25mm dia all as specified and directed.
Steel water tubing medium grade galvanized with all fittings and laid in trenches of size 20mm dia all as specified and directed.
Cutting existing steel tubing for 25mm bore of pipes for alterations or additions necessarily done in position without taking down (each cut measured) all as specified and directed.
Screwing existing steel tubing for 25mm bore of pipes for alterations or additions necessarily done in position without taking down (each cut measured) all as specified and directed.
Point wiring complete with 1.5 sqmm (nominal area) FRLS grade PVC insulated, unsheathed stranded copper conductor single core cable 1100 volts grade in and including PVC conduit medium grade complete with conduit fittings/accessories with provn of 1.2 mm thick MS terminal boxes of suitable size and 3 mm thick plastic laminated sheet top cover for housing of switches, sockets etc including 1.5 sqmm FRLS grade PVC insulated unsheathed stranded copper conductor cable for earth continuity conductor and connected to common earth dolly for One light/Ex-fan point controlled by one switch 5Amps SP all as specified and directed.
All as per item No 154 hereinbefore but 5A 2pin / 3 pin switch socket out let multipurpose on independent board all as specified and directed.
Switch piano flush type 5 A 240 volt SP, one way all as specified and directed.
Socket outlet 5 pin 5/6 Amps flush type multipurpose suitable for 3 pin / 2 pin plug complete all as specified and directed.
Ceiling rose, 3 terminals PVC/ polycarbonate, isolated body all as specified and directed.
Wall mounted 20W LED (4ft) batten comprising of thermally conductive material, pre-wired with high efficiency electronic driver, high translucent serrated milky white diffuser glare free, smooth light distribution lamp, colour white all as specified and directed. Make: CG Cat No: LDL-20-CDL or equivalent in Philips / Bajaj / Havells.
LED Security Light fitting of 25 watts comprising of epoxy powder coated housing, enclosed with glass cover in frame, with protection IP65 complete with all accessories and lamp colour white and fixing in and including GI bracket of suitable size/ dia all as specified and directed. Make:CG Cat No: LSTS-25-CDL-M or equivalent in Philips / Bajaj / Havells.
Exhaust Fan with metalli range 230mm sweep, single phase 230V, with grouting bolts, nuts and washers and connecting to ceiling rose complete all as specified and directed.
MCB DB SPN 4 way 230 volts, double door type with minimum capacity of 200 Amps rated bus bar including necessary dummy plate and necessary civil works all as specified and directed.
MCB SP 230V 6-32 Amps capacity all as specified and directed. Make: Havells Cat No DHMGCSPF006-032 or equivalent in Legrand / L&T
MCB SPN 230V 6-32 Amps capacity all as specified and directed. Make: Havells Cat No.DHMGCSNF006-032 or equivalent in Legrand / L&T
Spreading clean dry sand (rddled earth free from stones) in trenches/ ducts for cushioning to cable complete all as specified and as directed. Note: Punned thickness only shall be measured and paid.
Burnt bricks sub class 'B' old size for cable protection laid length wise perpendicular to the axis of cable complete all as specified and as directed
XLPE insulated screened PVC bedded, galvanised Steel Strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor, laid in trenches/ ducts, fixed on wall/ inside panel, drawn through pipe of size 2Core x 6Sqmm including testing and commissioning after laying complete including taking out the old unserviceable LT cable all as specified and directed.
Galvanized iron light grade pipe of 40mm dia for cable protection complete with all fittings fixed to wall or laid in floor/ road crossing or on pannel, complete all as specified and directed.
Exhaust Fan with PVC body 250mm sweep, single phase 230V, with grouting bolts, nuts and washers and connecting to ceiling rose complete all as specified and directed.
UNIQUE INDIA CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .