REPAIR/ MAINT OF TRANSFORMER HT/LT CABLE AND BASIC E/M WORKS AT NDC, RAKSHA BHAWAN , AHQ CAMP LODHI ROAD AND HQ IDS UNDER GE NEW DELHI, DELHI CANTT-10
2020_MES_371227_2
CWE-ND/37/2020-21
Open Tender
Miscellaneous Works
Item Rate
335 days
Delhi Cantt
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE New Delhi
₹89,600
Yes
8 Feb 2021
31 Oct 2020
30 Nov 2020
31 Oct 2020
28 Nov 2020
14 Nov 2020
Amount
Dehydration and filtration of the existing transformer/servo voltage stabilizer oil by Dehydration plant to achieve di-electric strength of 60 KV at the gap of 4 mm complete all as specified and directed . Notes:- Dehydration plant shall be brought at site by the contractor and shall also include the following provisions a) Testing of transformer /servo voltage stabilizer oil before & after dehydration shall be carried out as directed. b) The Unit of payment under this item shall be per liter of oil meant for all processes to the entire completion of jobs. (c) Contractor will maintain a register of dehydration and filtration of each and every equipment as per format given by Engr-in-charge and submit the same to Engr-in-charge.
Supply and filling mineral grade transformer oil EHV type conforming to IS-335 of 1983 for topping up or replacement in different existing transformers outdoor/indoors type of any capacity located and installed at different places and different height complete all as specified and directed . Note: - The entire quantity of transformer oil shall be procured in one go. The complete material shall be brought at site and then as per requirement oil should be shifted to site. Cost of this aspect deemed to be included in the quoted rate.
M&L for disconnecting power supply from HT VCB of capacity up to 630 Amps, taking out trolley unit & complete servicing of the same through decarbonising servicing & cleaning of the male/female isolating contacts, lubricating moving part, cleaning with CRC removing dust particles from bus bar chamber, spout gear mechanism and moving parts, repair to motor charge spring mechanism, including cleaning of Vacuum Interrupter and all HT bushings , Cleaning of Flashes if any and refixing of cable by fixing the nut bolt, Washer to HT side tightly and refixing the trolley at its original position and testing and putting on load complete all as specified and directed by tightening all nuts and bolts of entire trolley, checking proper operation of trolley all as directed, inserting trolley inside, and testing and putting on load complete all as specified and directed.
Supply and fix in replacement set of mechanical castle inter lock assy with key suitable for HT 11 KV VCB of rating 630 Amps(make CG) complete all as specified and directed.
Supply & fix in replacement closing coil assy 24/110 volts DC for VCB 11 KV 630 Amps capacity (make CG) complete all as specified and directed.
Supply and fix in replacement tripping coil assy 24/110 volts DC for HT 11 KV VCB of rating 630 Amps (make CG) complete all as specified and directed.
Supply and fix in replacement fixed contact block of VCB 11 KV 630 Amps capacity (make CG) complete all as specified and directed.
Supply and fix in replacement moving contact block of VCB 11 KV 630 Amps capacity (make CG)complete all as specified and directed.
Supply and fix in replacement Vacuum Interrupter , suitable for HT VCB 11 KV 630 Amps capacity (make CG) complete all as specified and directed.
Supply and fix in replacement Spring Charge motor & gear assembly 220 Volt AC suitable for VCB 11 KV 630 Amps capacity (make CG) complete all as specified and directed.
S&F in replacement plug and socket assembly for VCB 11 KV 630 Amps capacity
S&F in replacement auxiliary switch (6 No + 6 NC) for HT VCB 11 KV 630 Amps capacity
S&F in replacement 80 watts, 230 volts, AC, single phase rated strip heater with switch and thermostat for space for space heating complete suitable for VCB 11 KV , 630 Amps capacity all as specified and as directed.
M&L for preparation of old painted steel surfaces by brushing, cleaning stain, greasy spots with thinner & applying two coats of synthetic enamel paint using spray gun on all surfaces of HT 11 KV VCBs complete all as specified and directed.
M&L in replacement for supply, testing, commissioning of DC control panel for 30 Volts DC lead acid chargeable stationery battery set comprising of 15 cells 02 volts each having 90 Amps hour capacity with maintenance free batteries including battery charging set adequate capacity and control equipment sheet steel cabinet , floor mounted type suitable for input of 230 volts, single phase , 50 Hz, AC complete with external and internal wiring of all components, accessories all as specified for 11 KV VCB panels complete control wiring (for connecting the DC tripping set to HT 11 KV VCB panel board complete) shall be copper conductor single copper conductor single core and size not less than 2.5 sqmm complete and comprising in and comprising in and including of the following accessories:- (a) DC ammeter/ voltmeter in 96 sqmm size (b) Step down Transformer (c) Choke to limit the inrush current (d) Variac (Auto-Transformer) for the manual step less charging (e) Silicon rectifier stack (f) Auto-Off manual switch (g) Set of protection fuses, (h) Set of indicating lamp to indicate position of charging on auto boost , auto trickle mains on, Battery earth and fuse failure (j) Battery switch to indicate the battery voltage (k) 15 Nos of 2 volts, 90 AH batteries in charge.
Supply and fix in replacement over current & earth fault relay suitable for 11 KV VCB 400/630 Amps indoor control panel complete all as specified and as directed .
M&L for servicing, calibration, testing of 1000 KVA, 11 KV/415 V AC Dry type transformer including cleaning servicing and connection tightening and conducting following tests:- (a) Ratio Test (b) Vector Group Test (c) Winding Insulation Test (d) HT bushing set (e) LT bushing set Note: The work shall be executed by through OEM or their authorised service agent. The spares required to be replaced shall be paid and measured separately
S&F in replacement frequency meter digital type suitable for HT 11 KV VCB complete all as specified and as directed.
Supply & fix in replacement One set of 3 Nos pilot lamp LED type for indicate On/Off Trip, 24 Volts DC complete all as specified and as directed.
Supply, installation & testing of air circuit breaker of capacity 630 Amps, 4 pole, air break , horizontal manual draw out type compliance to IS 13947 suitable for 50 KA, 415 volts, 50 Hz with microprocessor release and protection against overload, short circuit & earth fault with automatically operated safety shutter including all main and auxiliary contacts , shunt release, interlock system with trip free operating mechanism complete all including replacement old unserviceable ACB of any capacity all as specified and directed.
Supply and fix in replacement fibre sheet transparent type including all gaskets to prevent oil leakage from conservator of transformer of any size as required. Complete all as specified and directed .
Supply and fix in replacement gasket set in between transformer body and top cover including all gaskets to prevent oil leakage after draining out Transformer oil in empty barrel to be provided by the contractor and filling the same oil after replacing gasket as required
M&L for hiring of Fault locating Machine mounted on Vehicle along with auxiliary power supply required for Installing of equipment connected to FLC Machine along with necessary manpower and T&P for finding out fault in cable HT (11 KV) / LT (1000 Volts) by using Ultra sound technique. Complete all as specified and as directed by Engr-in-Charge. Notes:- 1. Contractor shall bear all the cost incurred in arranging FLC machines along with permission of digging in case of land belonging to other than MES/Defence. 2. Penalty for non arranging the FLC machine shall be Rs.500 per hour after three hours from getting the information either from GE, Engr-in-Charge or concerned JE verbally or telephonically.
Supply and replacement of dehydrating agents (Silica gel) in transformers of capacity up to 1000 KVA transformer outdoor/indoor type complete all as specified and directed .
Supply and replacement of LT bushing (Brass stud and bolts with porcelain insulator) of suitable size to fixed the transformer capacity range 60 to 400 KVA including replacement of gasket , cable glands, etc. to make the transformer leak proof complete all as specified and as directed .
All as per item ser No 29.00 here-in-before but suitable for 500 KVA to 1000 KVA transformer
Supply only ceramic bushing and Gasket on LT side of transformer of following capacities :-
60 KVA to 400 KVA
500 to 1000 KVA
All as per item No 31.00 here-in-before, but on HT side of transformer of following capacities :-
60 KVA to 400 KVA
500 to 1000 KVA
M&L for Painting of transformer after cleaning the body surface of transformer by rubbing with emery Paper to remove oil stains, dust etc. and applying two coat of synthetic enamel paint by spray painting including preparation of surfaces of transformer of capacity 250 KVA to 1000 KVA complete all as specified and as directed.
M&L for fixing of MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA complete all as specified and as directed.
M&L for fixing of MCCB 3 Pole, 415 V, adjustable type 160 Amps with breaking capacity 36 KA complete all as specified and as directed.
M&L for fixing of MCCB 3 Pole, 415 V, adjustable type 200 Amps with breaking capacity 36 KA complete all as specified and as directed.
M&L for fixing of MCCB 3 Pole, 415 V, adjustable type 250 Amps with breaking capacity 36 KA complete all as specified and as directed.
M&L for fixing of MCCB 4 Pole, 415 V, adjustable type 200 Amps with breaking capacity 36 KA complete all as specified and as directed.
M&L for fixing of MCCB 4 Pole, 415 V, adjustable type 250 Amps with breaking capacity 36 KA complete all as specified and as directed.
M&L for fixing of MCCB 4 Pole, 415 V, adjustable type 400 Amps with breaking capacity 36 KA complete all as specified and as directed.
M&L for Anti climbing devices; comprising 2.24 mm dia galvanised steel 2-strand barbed wire with 2.00 mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered complete all as specified and directed .
M&L for fixing of Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15 cm size complete all as specified and as directed.
M&L for fixing of Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT 25 x 20 cm size complete all as specified and as directed.
M&L for Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp 11000 V. Complete all as specified and directed.
M&L for maintenance and overhauling of ACB 630 Amps to 1250 Amps capacity including disassembly all operating mechanism parts, well cleaning with petrol CRC 226, replacing unserviceable parts and accessories, oiling/greasing of moving parts, cleaning of all pole partition hylem sheet, isolating contacts, re assembly, fine setting of mechanism and pole assembly and making ACB perfect operational including well cleaning the complete bus bar chambers, insulator, partition etc. and checking of insulation resistance of ACB main bus bar complete all as directed . Note: - The work shall be carried out by OEM or their authorised service agent. The spares required for the item shall be paid and measured separately under relevant items and cost of fixing shall be deemed to be included in this item
Supply only in replacement Fixed Arc Contact- 3 pole
Supply only in replacement Moving Arc Contact- 3 pole
Supply only in replacement Auxiliary contact 4 No+ 4 NC
Supply only in replacement Motor Mechanism for 800 Amps ACB
Supply only in replacement Shunt Trip Coil
Supply only in replacement Control Fuses HRC type 2 to 10 Amps
M&L for servicing of Voltage Stabilizers capacity exceeding 75 KVA up to 150 KVA including replacement of minor equipment and spares complete all as specified and directed . Note- Cost of minor equipment and spares is included in the quoted rate .
M&L for servicing of Servo motor operated micro processor type digital display oil Cooled Voltage Stabilizers capacity exceeding 25 KVA up to 75 KVA including replacement of minor equipment and spares complete all as specified and directed . Note- Cost of minor equipment and spares is included in the quoted rate .
M&L for servicing Servo motor operated micro processor type digital display oil Cooled of Voltage Stabilizers capacity exceeding 10 KVA up to 25 KVA three phase including replacement of minor equipment and spares complete all as specified and directed . Note- Cost of minor equipment and spares is included in the quoted rate .
M&L for servicing of Servo motor operated micro processor type digital display oil Cooled Voltage Stabilizers capacity exceeding 5 KVA up to 10 KVA, three phase including replacement of including replacement of minor equipment and spares. Complete all as specified and directed . Note- Rate of spares deemed to be included in the quoted rate above.
M&L for servicing of Servo motor operated micro processor type digital display oil Cooled Voltage Stabilizers capacity up to 5 KVA, single phase including replacement of including replacement of minor equipment and spares. Complete all as specified and directed . Note- Rate of spares deemed to be included in the quoted rate above.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation etc. or for shaft well, cesspits, manholes etc. n.exc 10 sqmm on plan and not exceeding 1.5 mtr in depth and getting out complete all as specified and as directed .
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed .
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed .
M&L for sand cushioning (dry sand) to underground cable for cable protection laid in trenches / in existing cable ducts complete all as specified and as directed . Note: For payment purpose, compacted thickness of sand shall be measured.
Supply & laying in reinforcement PCC cable covers, class-HV type-I, flat, size 300x180x40mm complete all as specified and as directed by .
M&L for brick laying with sub class 'B' bricks well burnt, laid dry flat in trenches for protection of cable over LT cable, complete all as specified and as directed .
M&L for taking down of cable any size at any depth complete all as specified and as directed .
M&L for replacement of cable XLPE insulated screened PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 11000 volts grade with stranded aluminium conductor of sizes 95 sqmm 3 core complete all as specified and directed.
M&L for replacement of cable XLPE insulated screened PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of the following sizes complete all as specified and directed .
185 Sqmm 3.5 core
120 Sqmm 3.5 core
Supply & fixing cable jointing kit and testing complete for 11 kv grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified and directed.
All as per item No 66.00 here-in-before but of size 50 Sqmm to 95 Sqmm
Supply & fixing cable jointing kit and testing complete for 11 kv grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified and directed.
S & F, testing and commissioning heat shrinkable straight through Jointing Kit suitable for LT Cable of size 25 Sqmm to 50 Sqmm, 3.5 core complete all as specified and directed.
S & Fixing testing and commissioning heat shrinkable straight through Jointing Kit suitable for LT Cable of size 70 sq mm to 150 sq mm , 3.5 core complete all as specified and directed.
S & Fixing testing and commissioning heat shrinkable straight through Jointing Kit suitable for LT Cable of size 150 sq mm to 300 sq mm , 3.5 core complete all as specified and directed.
M&L for cutting of Hard standing/road by manual method up to 150 mm deep for inserting GI pipe for cable protection complete including ready mix concrete and making good disturbed surface complete all as specified and as directed.
M & L for galvanised pipe of dia 100 mm, 'light grade' with all fitting, laid in trenches for passing of cable etc. complete all as specified and directed .
M & L for replacement of potential transformer (voltage transformer) 11 KV/ 110 V, dry type , complete with winding, indoor resin cast & ratio 11 KV/rt3/110/rt3/class 0.5-3, burden 50 VA-50 VA including connecting and testing complete all as specified and directed .
Supply and installation, testing & commissioning with HT panel phase indoor resin cast CT of ranging 15 Amp to 150 Amp/5-5A as per each feeder required class 1.0/5P10, burden 15 VA-15 VA including connecting and testing complete all as specified and directed .
M & L for supply, installation and testing for Earthing complete with galvanised steel earth plate electrode 60cm×60Cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 shown in SSR Part-I connected to earthing test point complete all as specified or indicated including testing on completion complete all as specified and directed . Note:- GI strip 7.5 mtr from earth pit to test point included in the quoted rate.
M&L for replacement of Air termination, single pointed aluminium rod 12 mm dia and 300 mm long along with PCC block for mounting spikes complete all as specified and directed .
M&L for fixing of Aluminium strip 25x3.15 mm in replacement with saddles and fixing screws etc. for roof conductors and down conductors above on insulators complete all as specified and directed .
M&L for Test point terminal block in replacement made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8 mm dia 25 mm long hex. head screw complete all as specified and directed .
M & L for excavation by trenchless boring technology for holes under road pavement, hard standing using ultra sound technique and engaging necessary machine including HDPE pipe ISI marked of dia 200 mm suitable for 0.4 Mpa working pressure complete all as specified and directed . Note: HDPE pipe and marking good the disturbed surface shall deemed to be included in rate quoted by contractor.
M&L for Chemical Earthing complete with Copper earth plate 900 x 600 x 6 mm thick buried directly in ground (earth pit not less that 2.25mtr deep below ground level ) with top edge of the plate not less than 1.5 m below normal ground level connected to 32x6 mm copper strip as earthing lead by means of brazing after tightened by bolts, nuts, check nuts and washers from earth pit to test point with protection GI pipe of size 50 mm dia light grade and providing masonry pit and watering pipe of dia 25 mm including wire mesh steel funnel, including pouring watering approx. 200 ltrs for each earth pit complete as specified and directed Note: Copper strip 7.5 mtr from earth pit to test point included in the quoted rate.
M&L for fixing of Copper Strip 20x3 mm on wall / in floor by brazing of all joints and final connection to end point equipment using GI nut bolts complete all as specified and directed .
Supply only hand driven generator type insulation tester megger 1000 V metal body with accuracy ±5% complete all as specified and directed .
Supply only high voltage testing set (Hipot) capable of producing 25 KV DC output voltage with analogue meter and push button control along with calibrated rotary switch for DC HV generator complete with wire 1.5 Sqmm 2 core for tapping supply complete all as specified and directed .
Supply only in replacement for Discharge rod for discharging of HT side (11 KV). Complete all as specified and directed .
M&L for replacement for laying of HT (11 KV) insulation mat before CBs or LT panels complete all as specified and directed .
M&L for rectification of fault using eclectically operated Hi pot Machine to check the HT cable so that is stands a capacity of up to at least 14 KV complete all as specified and directed .
Outsourcing of manning & services of HT installation at Raksha Bhavan including Comprehensive maintenance maintenance of HT installation for three shift by employing one electrician highly skilled for each shift of 8 hours duration for 24 hours a day by employing the man power as under including Sunday / holiday for the following all as directed . (i) First shift - from 0600 hrs to 1400 hrs. (ii) Second shift - from 1400 hrs to 2200 hrs. (iii) Maintenance of oil level in conservator of transformer and to report the same in case of level of oil going down below low level. (iv) Maintenance of whole installation and surrounding area cleanliness. (v) Penal recovery for absent of electrician shall be Rs. 1000 per shift irrespective of duration of absence and no payment shall be made to contractor on contract rate for such shift(s). (vi) Cleaning of installation including operation of suction sweeper during operation / non operation periods including removing of floating dust, cleaning of walls of installation , to maintain hygienically using suitable machineries in working condition including greasing, oiling complete all as directed.
All as per srl item No. 88.00 here-in-before but for one shift at NDC
All as per srl item No. 88.00 here-in-before but for one shift at HQ IDS.
Supply, install, test and commissioning of out-door type LT distribution board made out of 3.15 mm thick CRCA sheet, CPRI approved, double door totally enclosed, weather, dust and vermin proof as per IS with front and rear opening, suitable locking arrangement, top with sloping canopy having aluminum bus bar of 600 Amp capacity for RYB and for neutral and insulated with insulators, including provision of cable glands, connecting incoming and outgoing cables necessary PCC 1:3:6 type C1 (20 mm graded stone aggregate) in foundation and suitable size of angle iron grouted at terrace floor above 300 mm from floor level, with and including provision of the following, complete all as specified and directed:- (a) MCCB, FP, 63 Amp rating with microprocessor release, Icu = 16KA, Ics = 100% of Icu with adjustable overload setting (minimum 70% to 100%) - 01 No. (incoming), (b) MCB, TPN, 40 Amp = 3 Nos. (outgoing) (c) Automatic Phase Sequence Corrector 30 KVA- 02 Nos. (d) Star Delta Starter suitable for 3 phase . 12.5 HP with suitable power contactors along with auxiliary contacts-03 Nos. (e) Digital ammeter of size 96 mm x 96 mm - 01 No. (f) Digital voltmeter of size 96 mm x 96 mm - 01 No. (g) R-Y-B phase indicator lamps LED type - 1 set. (h) Suitable rated CTS (i) Single Phase Preventer before starter-02 Nos NOTE:- The quoted rate includes necessary internal wiring for meters, CTs, indication lamps etc. and rigid bus bar connections from bus bar to MCCB terminals, connection bus to MCCB. (For out-door unit of Ground Floor and First Floor ACs to be placed / mounted over First Floor terrace)
Supply and fix in replacement wire meshed stainless steel (SS 304) cable tray 54 mm (h) x 400 mm (w) complete with nuts bolts washers (GI) and all accessories for mounting and supporting the cable tray system, along with vertical bends, bends.
Supply and fix in replacement wire meshed stainless steel (SS 304) cable tray 54 mm (h) x 600 mm (w) complete with nuts bolts washers (GI) and all accessories for mounting and supporting the cable tray system, along with vertical bends, bends.
Supply and fix in replacement wire meshed stainless steel (SS 304) cable tray 54 mm (h) x 200 mm (w) complete with nuts bolts washers (GI) and all accessories for mounting and supporting the cable tray system, along with vertical bends, bends.
Supply & fix in replacement Stainless steel cover for mounting and covering cables on cable tray width 400 mm along with clips complete with all mounting and supporting accessories.
Supply & fix in replacement Stainless steel cover for mounting and covering cables on cable tray width 600 mm along with clips complete with all mounting and supporting accessories.
Supply & fix in replacement Stainless steel cover for mounting and covering cables on cable tray width 200 mm along with clips complete with all mounting and supporting accessories.
IK ONKAR ENGINEER AND CONTRACTOR
Vijay Electricals
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .