Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 CrAccepted-AOC H M APARTMENT 4C S J ROAD ATHGAON GUWAHATI 781001 | GUWAHATI | KAMRUP METRO | ASSAM | 781001 | ₹4.1 Cr Quoted ₹4.2 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹4.3 Cr+₹8.4 L (1.99%)Rejected-Finance OPP BSF GATE NO 3 AZARA GUWAHATI 17 ASSAM | ₹4.3 Cr+₹8.4 L (1.99%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹5.1 Cr+₹93.2 L (22.1%)Rejected-Finance | ₹5.1 Cr+₹93.2 L (22.1%) | L3 | Rejected-Finance NOT LOWEST |
| Sl No | Description | Qty | Unit | M/s Dhani Enterprise L2 | G.K. TRADERS L3 | M/S. SUBHAS CONSTRUCTION CO. L1 |
|---|---|---|---|---|---|---|
| 0.00NOTE (Applicable for all items):- The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entrying/quoting the rates. SCHEDULE 'A' | ||||||
| 1.00 | Dismantling of plain or corrugated steel sheeting any gauge/thickness in roof or wall covering complete all as specified and as directed | 8,316.2 | SQM | 9 ₹74,845.8 Lowest | 20 ₹1,66,324 | 10 ₹83,162 |
| 2.00 | S & F pre-painted hot dip aluminium zinc alloy metallic coated trapezoidal profile steel sheet 0.50 mm thick (total thickness), any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws, complete all as specified and as directed. | 7,966.2 | SQM | 775 ₹61,73,805 | 750 ₹59,74,650 | 600 ₹47,79,720 Lowest |
| 3.00 | S & F pre-painted zinc alloy metallic coated plain steel sheet 0.50 mm thick (total thickness), any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws, complete all as specified and as directed. | 350 | SQM | 775 ₹2,71,250 | 750 ₹2,62,500 | 605 ₹2,11,750 Lowest |
| 4.00 | Supply, installation and testing of Air Extructor fan (Turbo Ventilator wind operated) of 29.5" Over all dia size, throat dia 24", fabricated with stainless steel complete with taflon bushing with aluminium blades (Approx 42 Nos) powder coated including FRP base plate 2 mm thick complete all as specified and directed by Engr-in-Charge. (Note- Turbo ventilator shall be fitted on Galvanised/PVC sheet as per sample given by the department). | 18 | EACH | 11,007 ₹1,98,126 | 6,500 ₹1,17,000 Lowest | 8,200 ₹1,47,600 |
| 5.00 | Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs of any thickness including cover fillets complete all as directed. | 700 | SQM | 9 ₹6,300 | 12 ₹8,400 | 7 ₹4,900 Lowest |
| 6.00 | M & L for suspended false ceiling using E-grid (exposed ceiling suspension system) of grid size 600x600mm with main runner 38mmx24mm and wall angle 24mmx24mm using 4mm thick Non Asbestos fiber cement designer board (E-Board classic) in a grid of GI system duly suspended with 4mm dia GI bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures air conditioning diffuser and ducts, sprinkler, smoke detectors etc. The main runners to be secured to structural soffits by hanger @ 1220mm maximum c/c, the last hanger at the end of each main runner should not be placed at more than 450mm from the adjacent wall, flush fitting 1220mm cross tee to be interlocked between main runners @ 610mm c/c so as to form 600x600mm grid complete all as specified and directed. | 700 | SQM | 1,050 ₹7,35,000 | 880 ₹6,16,000 | 680 ₹4,76,000 Lowest |
| 7.00 | Demolition of brick work including all quoins and arches pillars etc built in cement mortar complete all as specified and directed. | 33 | CUM | 99 ₹3,267 Lowest | 150 ₹4,950 | 300 ₹9,900 |
| 8.00 | M & L for brick work with sub class B bricks straight or curved on plan exc 6m mean radius built in CM 1:6 and complete all as specified and directed. | 30 | CUM | 8,100 ₹2,43,000 | 7,800 ₹2,34,000 | 7,500 ₹2,25,000 Lowest |
| 9.00 | All as item No 8 here-in-before but except bricks, complete all as specified and directed. | 3 | CUM | 2,700 ₹8,100 | 4,800 ₹14,400 | 2,500 ₹7,500 Lowest |
Tender Value
Refer Docs
EMD Value
₹5.9 L
Closing Date
14 Jan 2026, 6:00 pmClosed
CE SHILLONG ZONE
HQ CE SHILLONG ZONE, SPREAD EAGLE GALLS, SHILLONG MEGHALAYA
SPECIAL REPAIR OF ARMANENT REPAIR BAY IN 17 CORPS ZONE WKSP UNDER GE NARANGI
2025_MES_744782_1
89880/NAR/E8
Open Tender
Civil Works
Item Rate
600 days
NARANGI
ALL DETAILS AS PER NIT AND TENDER DOCUMENTS
2 documents required · 2 mandatory
₹3,000
GE NARANGI
₹5.9 L
Yes
5 Mar 2026
16 Dec 2025
16 Jan 2026
16 Dec 2025
14 Jan 2026
7 Jan 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling of plain or corrugated steel sheeting any gauge/thickness in roof or wall covering complete all as specified and as directed | 8,316.2 | SQM | - | - |
| 2 | Supply and fix pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of a colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and as directed | 7,966.2 | SQM | - | - |
| 3 | Supply and fix pre painted galvalume aluminum coating GI based plain steel sheet 0.50 mm thick of a colour having tensile strength of 550 Mpa as in ridges/valley fixed with self tapping screws complete all as specified and as directed | 350 | SQM | - | - |
| 4 | Supply, installation and testing of Air Extructor fan (Turbo Ventilator wind operated) of 29.5" Over all dia size, throat dia 24", fabricated with stainless steel complete with taflon bushing with aluminium blades (Approx 42 Nos) powder coated including FRP base plate 2 mm thick complete all as specified and directed by Engr-in-Charge. (Note- Turbo ventilator shall be fitted on Galvanised/PVC sheet as per sample given by the department). | 18 | EACH | - | - |
| 5 | Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs of any thickness including cover fillets complete all as directed. | 700 | SQM | - | - |
| 6 | M & L for suspended false ceiling using E-grid (exposed ceiling suspension system) of grid size 600x600mm with main runner 38mmx24mm and wall angle 24mmx24mm using 4mm thick Non Asbestos fiber cement designer board (E-Board classic) in a grid of GI system duly suspended with 4mm dia GI bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures air conditioning diffuser and ducts, sprinkler, smoke detectors etc. The main runners to be secured to structural soffits by hanger @ 1220mm maximum c/c, the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall, flush fitting 1220mm cross tee to be interlocked between main runners @ 610mm c/c so as to from 600x600mm grid complete all as specified and directed. | 700 | SQM | - | - |
| 7 | Demolition of Brickwork including all quoins and arches pillars etc built in cement mortar complete all as specified and directed. | 33 | CUM | - | - |
| 8 | M & L for brick work with sub class B bricks straight or curved on plan exc 6m mean radius built in CM 1:6 and complete all as specified and directed. | 30 | CUM | - | - |
| 9 | All as item No 8 here-in-before but except bricks, complete all as specified and directed. | 3 | CUM | - | - |
| 10 | Taking down cement plaster on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed | 450 | SQM | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.70 MB
BOQ_833955.xls
BOQ • 0.40 MB
MergedTender89880.pdf
Tender Documents • 7.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .