Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.3 LAccepted-AOC 2 4 136 4TH BLOCK LINGA REDDY MANSION OPP TARBUND SECUNDERABD TARBUND SECUNDERABAD TELANGANA 500009 | HYDERABAD | TELANGANA | 500009 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹38.8 L+₹2.5 L (6.80%)Rejected-AOC FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹42.0 L+₹5.6 L (15.5%)Rejected-AOC | L3 | Rejected-AOC Not being L1 | |
| 4 | L4₹43.0 L+₹6.7 L (18.4%)Rejected-AOC | L4 | Rejected-AOC Not being L1 | |
| 5 | L5₹43.4 L+₹7.1 L (19.4%)Rejected-AOC | L5 | Rejected-AOC Not being L1 |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
2 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Utility Secunderabad
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
REPAIR/REPLACEMENT OF ENERGY METERS AND ALLIED WORKS UNDER AGE E/M NO 1 OF GE (U) SECUNDERABAD
2021_MES_418984_1
GE(U)/SEC/TOKEN/57 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Secunderabad
As per NIT
7 documents required · 7 mandatory
₹500
GE Utility Secunderabad
₹89,000
Yes
19 Mar 2021
4 Feb 2021
4 Mar 2021
5 Feb 2021
2 Mar 2021
18 Feb 2021
60 days
Amount
Supply, fixing, Testing and Commissioning of AC single phase two wire, tamper proof, static meter of class 1.0, 240 V, 50 Hz, basis current 10 Amps-60 Amps, capacity max continuous current 600% of basis current conforming to IS-16444 and relevant IEC standards and latest BIS standards with inbuilt Low Power Radio Frequency (LPRF) communication facility in cyantech mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuits. The energy meter should fixed inside poly carbonte made transparent hinged box with sealing arrangement, the energy meter along with transparent box shall be fixed/mounted on MS sheet of thickness 2.00 mm with edges bended and this MS sheet shall be mounted on wall with distance between wall and sheet minimum 10 mm on four corners along with necessary fixing arrangements like anchor fasting/screws. The MS sheet shall be duly power coated and also including disconnecting of existing energy meter, fixing of wire to new energy meter incoming and out going terminal ends from the DB/existing sub main wiring along with necessary accessories, making good of disturbed surfaces compete all as specified and directed Engr-in-Charge. Make :- L&T/HPL
Supply, fixing, Testing and Commissioning of AC three phase four wire, tamper proof, static meter of class 1.0, 433 V, 50 Hz, basis current 10-60 A, max continuous current 600% of basis current conforming to IS-16444 and relevant IEC standards and latest BIS standards with inbuilt Low Power Radio Frequency (LPRF) communication facility in cyantech mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuits. The energy meter should fixed inside poly carbonte made transparent hinged box with sealing arrangement, the energy meter along with transparent box shall be fixed/mounted on MS sheet of thickness 2.00 mm with edges bended and this MS sheet shall be mounted on wall with distance between wall and sheet minimum 10 mm on four corners along with necessary fixing arrangements like anchor fasting/screws. The MS sheet shall be duly power coated and also including disconnecting of existing energy meter, fixing of wire to new energy meter incoming and out going terminal ends from the DB/existing sub main wiring along necessary accessories, making good of disturbed surfaces compete all as specified and directed Engr-in-Charge. Make :- L&T/HPL
Note for Ser item No 1 & 2 - (i) The rate quoted include cost of energy meter , MS sheet and all necessary E/M works, civil works and tools and plants. (ii) All energy meters execution & commissioning to be done by original Equipment manufacturers (OEM) authorised technician, rate deemed to include to be included in quoted rate. (iii) warranty certificate , test certificate (including meter calibration test ) for minimum year to be submitted after fixing of new energy meter in presence of user & department representative calibration shall be carried out by at site & certificate shall be submitted by original Equipment Manufacturers (OEM) Technician , rate deemed to be include in quoted rate. (iv) The contractor should be provide sealing to energy meter, sealing materials, necessary tools for sealing and also the following details to be submitted by the contractor like Qtr No., new meter fixed No. Initial reading , date of installation including meter card shall be given to AGE E/M No I (U) office and respective individual occupant, rate deemed to be included in quoted rate. (v) Old unserviceable Electric meters shall be handed over to AGE E/M No.I stores yard.
Supply, Install, Testing and Commissioning IP6V rated Data Concentrator Unit (DCU) compatible for remote Automatic Meter Reading (AMR) solution and capable of communicating with the static energy meter in the corresponding frequency band and with the data server through GPRS and shall have minimum data transfer rate of 9600 bps, internal memory to store data of 50 modules for 6 month period and shall be based on Cyantech Mesh network within 1 sq km range complete all as specified and directed by Engr-in-charge. Make :- L&T/HPL
Supply, install, testing and commissioning o IP 51 rated repeater unit with inbuilt Low Power Radio Frequency (LPRF) communication Facility and capable of communicating within Cyanetech mesh network with inbuilt AC power supply complete all as specified and directed Engr-in-charge. Make :- L&T/HPL
Supply, Install, Testing and Commissioning configuration of cloud hosted multi user web based Software with provision of following modules all as specified and directed by Engr-in-charge :- Make :- L&T/HPL/Secure (a) Meter Data Management Module:- The meter data management module would be responsible for collecting the data from the concentrator and make the data available to the billing system. The system would support offline meter data entry. The meter data management system would capture and provide the following data:- (i) 30 minutes instantaneous data from all the meters for seven parameters i.e., Cumulative Energy, Cumulative Apparent Energy, Power, Current, Voltage, Power Factor and Frequency. (ii) The monthly and quarterly billing survey data for cumulative energy and maximum demand. (b) Billing Module:- The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data / billing data available to administrative and end users.
(c) Occupation and Vacation Module:- The system would support occupation / vacation based on the unit categories. The system would support automatic data capture on occupation and vacation events. (d) Customer Portal:- The system would include a customer portal for the resident /occupant to login and view their own energy / billing data. (e) Energy Accounting Module:- The system would include features of energy accounting. The system would be able to account for total energy block wise, facility wise and would also allow calculations of unaccounted energy in case total energy meter is also available. (f) Communication Module:- The system would provide communication of energy data and bills via print, email and sms methods. (g) Meter Master Data:- The system would support meter master data repository and also would support meter replacement process. (h) Excel Export:- The system would support export of metering and billing data in excel format. all as specified and directed. Make :- L&T/HPL
Material and labour for sub main wiring surface with two run of 4 sqmm PVC insulated unsheathed FLRS copper conductor single core multi stranded and one run of insulated copper earth wire 4 Sqmm drawn through PVC conduit complete all as specified and directed. Make :- Polycab/Fincab/Havells Note :- Copper conductor 2 run of 4 sqmm, one run of 4 sqmm earth wire and one run PVC conduit shall be measured as one length
Material and labour for sub main wiring surface with two run of 6 sqmm PVC insulated unsheathed FLRS copper conductor single core multi stranded and one run of insulated copper earth wire 6 Sqmm drawn through PVC conduit complete all as specified and as directed by Engr-in-Charge. Make :- Polycab/Fincab/Havells. Note :- Copper conductor 2 run of 6 sqmm along, one run of 6 sq mm as earth wire run with PVC conduit shall be measured as one length
L and S ENTERPRISES
sandhya enterprises
MVS ENTERPRISES
POWER CONSTRUCTION COMPANY
Srinivash Engineers
ACE PROMOTERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .