| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹49.2 L+₹4.1 L (9.03%)Rejected-Finance BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹50.5 L+₹5.3 L (11.8%)Rejected-Finance M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹50.5 L+₹5.3 L (11.8%)Rejected-Finance KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹51.3 L+₹6.2 L (13.6%)Rejected-Finance | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
26 Apr 2023, 6:00 pmClosed
GE I RD East Bangalore
GE I RD East Bangalore 93
REPAIRS REPALCEMENT SERVICING TO HT SWITCH GEARS 66KV 11 KV SF6 VCB OCB AND OVERHAULING OF 66 11 KV TRANSORMERS AT 66 KV MAIN RECIVING STATION NO 1 II UNDER GE I RD EAST BANGALORE
2023_MES_587277_1
8384
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE I RD East Bangalore
D b (ii)
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D East Bangalore
₹96,000
Yes
10 Aug 2023
28 Mar 2023
28 Apr 2023
28 Mar 2023
26 Apr 2023
11 Apr 2023
29 Mar 2023 - 5 Apr 2023
Amount
Material and Labour for maintenance, servicing & Oil Leakage arresting of 66/11 kV, 5/8 MVA Power Transformer, providing necessary gaskets, Oil Seals, cleaning, dusting, decarbonising, tightening loosened parts, including replacing worn out part copper studs, bolts nuts and washers replacing oil Seals, HT bush, gasket including unserviceable coil, replacing of defective minor items such as as and when required complete all as specified and as directed. Note:- The item spare parts oil to be replaced shall be measured and paid separately shall be deemed to be included in the unit rate, including decaning of old oil
Replacement of old unserviceable breather of power transformer 66 KV / 11 KV of capacity 5000/8000 KVA (capacity 5 Kg) fresh silica jel
Servicing of existing Fire Extinguisher & refilling of dry type fire extinguisher ever safe ABC stored pressure type with pressure 24 bar( 27 degree centigrade) and working pressure 12 bar at ( 27 degree centigrade) with capacity 0f 2 kgs to 50 kgs Capacity Cylinders complete all as specified & directed, with providing the Testing Certificate
Supply and Installation of 75kg ABC Higher Capacity Trolley Mounted Dry Chemical Powder Type Fire Extinguisher (With Co2 & Powder) complete all as specified & directed, with providing the Testing Certificate
Material and labour for filtration of transformer oil of transformer including OLTC through high vacuum type filtration plant to extract moisture, carbon deposits, to achive and withstand 80 KV die electric strength for 1 min with an air gap of 2.5 mm including necessary testing before, after filtration, submission of test result, complete all as specified and as directed. for 5 MVA - 02 nos & 8 MVA - 01 no and 11/0.433 KV transformer of 250 KVA with providing the Testing Certificate. Note: (a) The contractor will take shut down orders in working before commencement of the work from Engr in charge. (b) The contractor shall ensure no wastage of existing transformer oil. (c) The contractor solely responsible for any dammages to the transformer/HT OCB during the prosses of oil filtration. He is responsible for making good any damage to the transformer/HT OCB at his own cost without any extra cost to the department. (d) The contractor shall ensure that the conservator tank are full to its level before starting the dehydration. (e) Di-electric strength of oil after filtration/ dehydration shall not be less than 60 KV/min. (f) The di-electric strength of oil shall be tested before & after filtration and test results shall be submitted to Engineer-in-Charge.
Supply and topping up of new transformer oil conforming to IS 335-1963 as amended duly filtered and tested to with stand die electric strength of 60 KV for one minute with air gap 2.5 mm of HT transformer, OCB's CT's MOCB's etc complete all as specified and as directed. Make: Electrol / Servo
Supply & Fix in replacement of 66 KV, 800 Amp copper GOS with insulator in existing structure with necessary aluminum busbar / conductor connection in both sides with suitable clamping arrangements for smooth operation including testing all as directed : Notes Rates quoted by the contractor shall deemed to include for complete testing of insulator and GOS for entire satisfaction of Engr-in- Charge.
Supply and fix in replacement of outdoor type heat-shrinkable termination joint suitable for all climates, areas, and environments, even severely polluted areas, as well as for all installation conditions, including top feed installation and heat-shrinkable stress control sleeves non-tracking, heat-shrinkable outer insulation water- and corrosion-resistant, of conductor cross section 95-2500 sqmm, diameter over cable insulation 30-86mm, max diameter over outer cable sheath 110 mm creepage distance appx 2300 mm all as per Raychem product description OHVT-72H or equivalent make
Supply and refilling of SF6 (Sulfur hexaflouride gas ) for 66 KV SF6 outdoor circuit breaker to cool and Quench the arc on opening of circuit transmission class discharge capacity of 69KV for normal operation to maintain the desired pressure in SF6 and RMU as per OEM design and testing the pressure of each SF6 breaker of 66 KV and 11 KV RMU all as specified and directed
Supply & fix in replacement of old unserviceable CT with new CT 11 KV, CT ratio 300 / 5 -5 - 1 A for 5 MVA Transformer Additional control relay panel for protection complete all as specified and as directed. Make: KALPA/ INSTRANS/PARAS
Supply & fix in replacement of old unserviceable CT with new CT 11 KV, CT ratio 420-240 / 5 -5 - 1 A for 8 MVA Transformer Additional control relay panel for protection complete all as specified and as directed. Make: KALPA/ INSTRANS/PARAS
Supply & fix in replacement of old unserviceable Lighting arrestor 66 KV complete all as specified and directed. Make: LAMCO/ABB/SCHNEIDER
Supply & Fixing in replacement of old unserviceable of Aviation Tower Arial Lights complete all as specified and directed.
Material and labour for servicing OLTC (on load top changing) system of 5/8 MVA, 66/ 11 KV power transformer after draining out transformer oil cleaning and checking the entire system, checking all moving contact portions, replacement of worn-out fixed or Roller contacts, resistor and Top gasket cleaning and checking of hylam barrier sheet (3nos) cleaning and checking of main driven shaft, all mechanical parts of driving mechanism, greasing where required for smooth operation, replacement of worn out brass nuts, tightening of gears, checking of entire system complete all as specified and as directed. (Note: Dehydration of oil, and spares required shall be measured and paid separately)
Supply only OLTC Spares required for 5 MVA Transformer
Fixed contacts
Roller contacts- 3 sets
Resistor
Top gasket
Testing of outdoor SF-6 circuit breaker of rated voltage 66 KV for 5/8 MVA 66 KV transformer by checking the three pole SF6 breaker closing & Tripping Timing complete, Overhauling motor and gear mechanism, repair to all power contactor 1100 volts, and testing the control cables and cable connection for the smooth functioning of system complete all as specified and as directed.
Supply and fix in replacement of old unserviceable PT with new potential transformer resin cast epoxy with protective enclosure of ratio 11 KV/RT3/110V/RT3/110V/RT3 Class 1.0/3P, Burden 100VA/50VA Voltage Factor 1.2 continuous / 1.5 for 30 seconds. ILV 12/28/75 KVP. Ins class B Ref Std IS : 3156/1992 One end earthed type with one No HRC fuse on HV side.Note :Primary Neutral to be solidly earthed including removing of old unserviceable PTs. Make : KALPA / INSTRANS/PARAS
Supply & Fixing of Tripping coil for 11 KV 400/800 Amp VCB 30/110 V DC including taking out old unserviceable coil complete all as specified and as directed.
Supply & Fixing of Closing coil for 11 KV 400/800 Amp VCB 30/110 V DC including taking out old unserviceable coil complete all as specified and as directed.
Supply & Fixing of spring charging motor for 11 KV VCB including taking out old unserviceable.
Supply & Fix of Master Tripping Relay rating of 24 / 30 / 110 V dc for the existing HT VCB/OCB/RMU 11 KV Panels complete all as specified and as directed. Make: EASUN REYROLLE / C&S
Supplying of Vaccum Interupter Bottle for the existing HT VCB for including taking out old unserviceable Vaccum Interupter Bottle complete all as specified and as directed
Supply and fix heat shrinkable HT 11KV out door type cable end termination suitable for XLPE cable of 3 core 185 sq mm earth system with necessary jointing material and labour termination kit including connection etc complete all as specified and as directed. Make: RAYCHEM/MSEAL/DENSON
Maintenance and servicing of 66 KV GOS, cleaning of carbon pits, greasing, checking proper alignment, lubrication with petroleum gel/CTC including replacing of defective minor items as and when required, Testing smooth operation with electrically driven motor mechanism complete all as specified and as directed.
Servicing and Testing of Indoor floor mounted remote control cubicle RTCC panel of by testing remote tap position indicator meter, tap changer in progress signal lamp with belt. Raise / lower push buttons for remote operation. Supply on / off indicating lamps, control cable and cable connection all as directed by the Engineer-in-Charge at site
Material and labour for painting all steel poles, all steel structures, complete with cross arm, lightening arresters, GOS structures, Busbars, PT/CT structures, SF6/MOCB structures, insulator supporting structures etc with two coat of synthetic enameled paint of existing colour including filling cavities with filler after cleaning dust at 66 KV MRS I complete all as specified and as directed.
Material and labour for painting of 5/8 MVA Transformer complete with cross arm, Busbars, insulator supporting structures etc with two coat of synthetic enameled paint of existing colour including filling cavities with filler after cleaning dust at 66 KV MRS complete all as specified and as directed.
Testing of power transformer 66 KV / 11 KV of capacity 5000 KVA/ 8000 KVA by the authorized company representative and test certificate shall be furnished. All as directed by the Engineer-in-Charge (a) Insulation resistance test (b) Oil temperature alarm trip (c) Winding temperature alarm trip (d) Bucholtz relay alarm trip (e) Low oil level alarm trip (MOG) (f) Vector group (g) Di-electric test of transformer oil (h) Short circuit test (j) Transformer ratio test (TRT) (k) Magnetic core balance test (MBT)
Replacement of unserviceable existing make and model IDMT relay numerical non directional over current and earth fault relay with communication feature (RS 485) with full automation system type Argus, Aux voltage 110 volt DC should comprise of the following feature :- (a) Three phase over current and one earth fault (b) High set - low set (c) RS-485 with full communication system (d) Multi characteristic for both over current and earth fault, Make: L&T / SCHNEIDER / SEIMENS / ABB / C&S
Supply & Fix of Multi Data Meter, measuring Voltage, Current, PF, HZ, KWH, KVAH, KVARH for out going various feeders to different Labs complete all as specified and directed. Make: SCHNEIDER / ELMEASURE
Taking down old unserviceable CT Supply install testing and commissioning of CTs 66 KV class for foiilwing ratio out door type oil immersed as per IS 2705 with insulators electrical connection as per manufacturers instruction complete CT shall be rated voltage of 72.5 KV accuracy PS Class for REF class 1 for metering 5P-10 for protection Ratio 200-100/1-1-1 Amp, Make: LAMCO / ABB / SCHNEIDER
Supply & install, testing and commissioning indoor type 30 Volts battery charger suitable for and including 15 Nos Batteries, 2V in put single phase 230 volts and out put Float 25-35 Volts DC @10 A, Boost 29 Volts at power factor 0.8 and degree of protection IP4x, complete internal wiring with suitable copper condutor wires and each battery & charger should be mounted in the same panel with suitable ventilation, floor mounting panel fabricated out of 3 mm thick CRCA sheet with suitable angle iron frame and legs made of suitable angle iron, painted with powder coated and pre coted primer including with locking arrangement complete all as specified and as directed by Engr-in-Charge Make : ABB/Schnieder/Seimens/L & T
Supply & fix tripping & closing coil with assembly for 66 KV SF6 breaker DC 110 V 100 W including taking out old unserviceable coil assembly, complete all as specified & directed, as per exsiting
Demolition of reinforced cement concrete as in man hole cover slabs, beams , and similar work including cutting, reinformcement to faciliate demolition.
Pre-cast reinforced cement concrete 1:2:4 type B-1 using 20 mm gradced stone aggregate in manhole cover / slabs and placing in position and set in cement mortar (1:4) including necessary form work complete all as specified and directed.
M&L Mild steel TMT bars 10mm dia and over, cut to length , bent to shape required , including cranking , bending spirally for hooping for columns and binding with and including mild steel wire (annealed) , not less than 0.9 mm dia, complete all as specified.
Supplying, spreading & leveling graded course stone aggregate of 40 to 80 mm size to the existing sub station all as specified and as directed. Note :- Aggregate nominal size without any vegitation or chemical including levelling/spreading surrounding transformer, HT/LT 2/4 pole structure and LT/HT panel complete all as directed .
Supply and fixing LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specifed and directed.
Supply & Fix of 66 KV Grade Aluminum Pad Clamps
Supply & Fix of 66 KV Grade Lightning Arrestor Clamps
Supply & Fix of 66 KV Grade Current Transformer Clamps
Supply & Fix of 66 KV Grade Potential Transformer Clamps
Supply & Fix of 66 KV Grade 'T' Clamps
Supply & Fix of 66 KV Grade Flexible Bus Joints
Supply & Fix of S/S Bolts, Nuts & Washers for the existing structures & etc
Supply & Fix of 66KV Grade drake
Opening dismantling of Mechanical moving part of existing 66 KV SF6 like ratchet wheel assembly with stopper roller and ratchet small wheel assembly of CG make and replace the same with new assembly for proper functioning the same and testing complete after replacement for entire satisfaction of Engr-in- charge all as specified and directed.
Supply and fix HT spout bussing for VCB HT 11 KV, busbar side including taking out old unserviceable bushing complete all as specified and directed.
Supply and fix Flanged Gate Valve Size 100 mm dia for the existing Transformer for including taking out old unserviceable Valves complete all as specified and as directed
Supply and fix Flanged Gate Valve Size 50 mm dia for the existing Transformer for including taking out old unserviceable Valves complete all as specified and as directed
Supply and fix Gate Valve Size 25 mm dia for the existing Transformer for including taking out old unserviceable Valves complete all as specified and as directed
Material and labour for finding out the cable fault of any size of cable upto 11 KV underground cable (HT and LT and of any capacity of cable with the help of cable fault loacator mounting on vehicle and with nessary disconnection of cable from two ends and making connection by joing after repairs and having the following items with electrician at site to find fault of up to length of 10 KM cable complete all as specified and directed by Engr-in-Charge with help of the following accessores- (a) Surge Generator with accessories (b) Head Phone (c) Pin Point Set T-505 with accessories (d) Earthing cable with clamp (e) Cable fault Locator T-905 with accessories (f) TC-808 with accessories (g) Soldering Iron/wire/capacitor unit/capacitor connecting cables/ power cable/nose plier. Notes: Excavation for the cable fault shall be done by the contractor by his own arrangement.
Supply laying & testing in replacement of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminum conductor,11000 volts grade, of size 3 core 300 Sqmm including taking out of old HT cable from trenches all as specified and directed by EIC.
M & L for taking out existing HT/ LT cables of any size and make from duct / trenches with removing stone patties/ cable covers by disconnecting from transformers/OCB's/LT switches and relaying if required /stacking properly all as directed by the Engr. In charge. Note:- Excavation & earth work will be measured & paid seperatly under respective item.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying cables / poles foundation / stay assembly and getting out in hard / dense soil all as directed by Engs-in -charge.
Removing excavated material not exceding 50 m and depostingwhere directed at a level not exceding 1.5 m above the starting point.
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm all as specified all as directed by Engr-in -charge.
Material and labour for Sand cushioning to under ground cable providing with a layer 8cm thick before laying the cable and 15 cm thick after laying the cable complete all as specified and as directed Note: Punned thickness only will be measured for the purpose of payment.
M & L for Un- reinforced pre cast concrete covers class HV type 300mmx 180mm x 40mm size factory made for cable protection complete all as specified and directed.
Supply & Fix in replacement of old unserviceable cable with new control cable 1100 volt grade with PVC insulated steel armoured with multi stranded copper conductor for the following sizes :-
(a) 2 core 2.5 sqmm
(b) 4 core 4 sqmm
(c) 10 core 2.5 sqmm
(d) 16 core 1.5 sqmm
Special earthing of 66/11 KV 5/8MVA transformer body earthing by cast iron pipe of length 3 meter with 4 inch dia, material and labor complete accessories buried directly in ground vertically to a depth of not less than 2.75metre below ground level and connected to GI earth strips 32x6 mm by means of welding. GI protection pipe 40mm bore medium grade and connected to main switch/earth bus bar including Magnesium sulphate, salt and coal mixture in each layers with IS specification including necessary earth work in any type of soil and PCC (1:3:6) type C1 (using 20mm graded stone aggregate) earth chamber, RCC (1:2:4) type B1, cover 40mm thick with 6mm dia MS bars complete all as specified and as directed. Notes: Rate quoted is deemed to include the cost of excavation and earth work, PCC pit, funnel and cover, GI strip complete all as specified.
Earthing complete with galvanised iron plate electrode 600 x 600 x 6.00mm thick GI earthing lead burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with the top edge of the plate at a depth not less than 1.5 mtr from below normal GL, connected to and including Galvanised iron strip 32x6 mm as earthing lead by means of nuts, bolts, washers, checknuts of galvanised iron and connected to earthing test point all as shown in electric plate No. 3 of SSR Part l of 2010 and as specified or indicated and testing on completion including excavation / earth work in any type of strat PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement cioncreat (1:2:4) type B1 (Reinforced with welded steel wire fabric (XPM)) weight not less than 4 Kg/sqm,cast iron frame, funnel with wire mesh, including GI earth strip with GI protection pipe of 40mm medium grade 7.5 meter long etc complete and testing on completion all as specified and directed. Note: 1. Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. 2. GI strip above 7.5m will be measured and paid seperately. 3. Earth resistance not exceeding 1.0 ohm.
Supply and fix Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-44 (10 metres long) including excavation, PCC and taking out the old unserviceable pole complete all as specified and as directed.
Supply and fix GI strips of size 32 mm x 6mm for body earthing for the transformer 5/8MVA 66/11 KV and CTs, PTs out door including fabrication work such as bending, drilling making holes for connecting with welding works as directed including excavation and earth work and taking out the unserviceable strip complete all as specified and as directed.
Supplying, spreading & leveling stone aggregate of 20 mm size to the existing sub station all as specified and as directed.
RAHUL ENTERPRISES
RRK PROJECTS
GS TRADERS
KARTHIK INCORPORATE
Lucky Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .