Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC ACCEPTED |
| 2 | L2₹1.3 Cr+₹15.4 L (13.4%)Rejected-Finance | ₹1.3 Cr+₹15.4 L (13.4%) | L2 | Rejected-Finance HIGHER THEN L1 BIDDER |
| 3 | L3₹1.3 Cr+₹16.1 L (14.0%)Rejected-Finance | ₹1.3 Cr+₹16.1 L (14.0%) | L3 | Rejected-Finance HIGHER THEN L1 BIDDER |
| 4 | L4₹1.3 Cr+₹17.2 L (15.0%)Rejected-Finance 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | ₹1.3 Cr+₹17.2 L (15.0%) | L4 | Rejected-Finance HIGHER THEN L1 BIDDER |
| 5 | L5₹1.3 Cr+₹19.1 L (16.6%)Rejected-Finance | ₹1.3 Cr+₹19.1 L (16.6%) | L5 | Rejected-Finance HIGHER THEN L1 BIDDER |
Tender Value
₹1.2 Cr
EMD Value
₹2 L
Closing Date
4 Jul 2024, 6:00 pmClosed
CWE
HQ 136 WORKS ENGINEERS PIN - 914136 C/O 99 APO
PROVISION OF FIVE SINGLE JCOs ACCN AT RHENOCK UNDER GE 867 EWS
2024_MES_657858_1
CWE/136-WE/08 OF 2024-25
Open Tender
Civil Works
Item Rate
364 days
Kalimpong
Class B, Category a(i)
8 documents required · 8 mandatory
₹1,000
GE 867 EWS
₹2 L
Yes
6 Dec 2024
5 Jun 2024
5 Jul 2024
5 Jun 2024
4 Jul 2024
27 Jun 2024
5 Jun 2024 - 14 Jun 2024
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out soft/loose soil, complete all as specified and directed.
Removing of excavated material (soils) to a distance not exceeding 50m and depositing where directed at a level n.exc 1.5m above from the starting point, complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, laying of underground cables etc. or for shafts, wells, cesspits, manholes, pier holes, under groung cables etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil, complete all as specified and directed.
M&L for plain cement concrete (1:4:8), type D2 (using 40 mm graded stone aggregates) as in foundation, filling and mass concrete, complete all as specified and directed.
Returning filling in soft / loose soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm, complete all as specified and directed.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished surfaces of concrete on flat surface, complete all as specified and directed.
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete on square rectangular on plain or polygonal, complete all as specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc., rough finished surfaces of concrete on flat surface, complete all as specified and directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), rough finished surfaces of concrete on flat surface, complete all as specified and directed.
M&L for reinforced cement concrete M-25 (design mix) (using 20mm graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed.
M&L for reinforced cement concrete M-25 (design mix) (using 20mm graded stone aggregate) in columns, pillars, piers, post and struts, complete all as specified and directed.
M&L for reinforced cement concrete M-25 (design mix) using 20 mm graded stone aggregates in beams, cantilevers, bressummers, lintels over 1.5m span, RCC band etc., complete all as specified and directed.
M&L for reinforced cement concrete M-25 (design mix) (using 20mm graded stone aggregate) in Slabs supported on walls, beams and columns ub floors, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like, complete all as specified and directed.
S&F of TMT bars 10 mm dia and over, cut to length, bent to shape required , including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified and as directed.
M&L for pre-cast cement concrete block masonry (1:3:6), type C-1 (using 20mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar (1:6), complete all as specified and as directed.
M&L for 15 mm thick rendering in cement mortar (1:6) on stone masonry surfaces or surfaces other than fair faces of brick work, rendering finished even and smooth (without using extra cement), complete all as specified and directed.
M&L for preparation of new plastered or unplastered surface of wall and applying two coats of distemper oil emulsion (OBD), over a coat of priming coat (Chalk whiting, on plastered surfaces, prepara-tory to distempering) including 1mm thick wall care putty on wall, complete all as specified and directed.
M&L for rendering 20mm thick (two layer, 10mm and 10mm thick) in cement mortar (1:4) with water proofing compound @ 3% by weight of cement in second layer or in the manner specified by the manufacturer and in the proportions indicated on fair faces of brick work or concrete surfaces, finished even and fair (without using extra lime or cement), complete all as specified and directed. Note: Water proofing compound will be measured and paid separately
M&L for preparation of new plastered or unplastered surface of wall and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and directed.
M&L for 5mm thick rendering in cement mortar (1:3) on concrete surfaces in ceilings and finished even and smooth (without using extra lime or cement), complete all as specified and directed.
M&L for preparation of new plastered or unplastered surface of ceiling and applying two coats of oil bound distemper (distemper oil-emulsion) over a coat of priming coat (alkali resistant priming paint, on plastered surfaces, preparatory to distempering) including 1mm thick wall care putty on ceiling, complete all as specified and directed.
M & L hardcore of gauge exc 63mm but n exc 100mm broken stone or boulders, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface, complete all as specified and directed.
M&L for 75mm thick plain cement concrete (1:4:8), type D2 (using 40mm graded stone aggregate) as in sub-base, sub-floors, floors, pavings etc., all as specified and as directed.
M&L for 15 mm thick screed bed or bedding layer of cement mortar (1:6) for laying floor finishes even and rough, complete all as specified and directed.
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tiles, complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces, complete all as specified and directed.
M&L for coloured glazed ceramic tiles in vertical surface 300x 200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match to surfaces, complete all as specified and directed.
M&L for 75 mm thick plain cement concrete(1:3:6), type C2 (40 mm graded stone aggregate) as in flooring, plinth protection, hard standing, path etc including finish the surface rough to receive screed bed/ topping, complete all as specified and directed.
M&L for 75 mm thick plain cement concrete(1:3:6), type C2 (40 mm graded stone aggregate) as in flooring, plinth protection, hard standing, path etc including finish the surface even and smooth with using extra cement, complete all as specified and directed.
S&F of pressed steel frame of size 165 x 60mm for door with one or more rebates including necessary fixing, lugs, hinges, lock, strike plate etc., complete all as specified and directed.
S&F of 35 mm thick (batten thickness) second class hard wood, plain, framed panelled shutters (any number of panels), with panels of 12 mm thick timber flat on both sides (feather edged), or of 12mm thick veneered particle board medium density wood particle board with commercial face veneers complete all as specified and directed. (Note :- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I)
S&F of 30 mm thick (batten thickness) second class hard wood, glazed and Skelton shutters, open rebated and prepared to receive glass, gauge, etc , divided into squares, with plain chamfered or rounded, mitred and rebated sash bars, edges of framing plain, chamfered or rounded with cut mitred beds for securing glass etc, supplied and fitted to chowkhats, complete all as specified and directed. (Note :- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I)
S&F of solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing, complete all as specified and directed.
S&F of factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing and as directed.
S&F of steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and directed.
S&F of steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded, complete all as specified and directed.
S&F of mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed.
S&F of steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed.
S&F of 3.0mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, complete all as specified and directed.
S&F of 3.0 mm thick figured glass, pin head type and glazing with oil putty in square not exc 0.50 sqm in each pane, complete all as specified and directed.
S&F of galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
M&L for preparation of new wood or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
S&F of 200mm long aluminium anodised, barrel tower bolts of extruded section and fixed, all as specified and directed.
S&F of 300 mm long aluminium alloy, anodised sliding door bolts with haps staple(bolt type), and fixing clips of sheet, cast or extruted sections and fixing bolt and sliding bolts of extruted sections or cast aluminium alloy and fixed, complete all as specified and directed.
S&F of 150 mm size aluminium handles, cast type, anodised, all as specified and directed.
S&F of aluminium (extruded section) body door closer hydraulically regulated, designation No. 1 universal type, suitable for door shutters up to 700 mm in width and of weight not more than 35 kg and fixed, all as specified and directed.
S&F of 75 mm size butt hinges, medium weight, cold rolled mild steel and fixed, all as specified and directed.
S&F of 75 mm bore PVC (SWR) bend any radius with access door complete all as specified and directed.
S&F of 75mm bore PVC (SWR) junction double, (double T), equal or unequal, complete all as specified and directed.
M&L for 75mm diameter of outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as specified and directed.
S&F of 20 mm bore steel water tubes, medium grade, galvanised with and including all GI fitting (such as bends, elbows, Tees, connectors, short pieces, back nuts, unions, caps and plug etc ) and fixed complete to wall and ceiling or laid in/on floor, complete all as specified and directed.
S&F of 15 mm bore steel water tubes, medium grade, galvanised with and including all GI fitting (such as bends, elbows, Tees, connectors, short pieces, back nuts, unions, caps and plug etc ) and fixed complete to wall and ceiling or laid in/on floor, complete all as specified and directed.
S&F of 15mm bore dia bib taps, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed.
S&F of 15mm bore dia pillar taps, cast copper alloy, fancy type with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, complete all as specified and directed.
Supply and fixing of 20 mm bore dia stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, all as specified and directed.
S&F of 15mm bore dia stop valves, chromium plated, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed.
S&F of PVC connections 15mm size with PTMT nuts of length 450mm, all as specified and directed.
S&F of shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms), complete all as specified and directed.
S&F of towel rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms), complete all as specified and directed.
S&F of vitreous china wash basin white of any pattern, flat back of size 550mm x 400mm (excluding taps), waste, chain and plug including waste pipe, suitable size of brackets including pedestal and bracked, complete all as specified and directed.
S&F of vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including mild steel chromium plated health faucet suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook and plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, complete all as specified and directed.
S&F of health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position, complete in all respect as specified.
S&F of PVC low level flushing cistern 10 Ltr capacity, valveless syphonic action type complete with inlet, ball valve, float valve, bends brackets, rawl plug, brass screws handle etc complete having BIS description mark with IS-2731 with and including suitable size of MS brackets, plug, screw all as required incl taking down existing high level/low level flushing cistern any type disconnecting pipes and jointing with new one etc, and making good the floors/walls as per existing floor finish/wall finish including 32 mm bore PVC flush pipe and jointing with water closet of any type, complete all as specified and directed.
S&F of toilet paper holder with flat recessed type stainless steel fixed to wall, complete all as specified and directed.
Excavating over areas (exceeding 1.5m width), n exc 1.5 m deep and getting out in soft / loose soil, all as specified and directed.
Excavating over areas, exc 1.5 m deep and n exc 3.0 m deep and getting out in soft / loose soil, all as specified and as directed.
M&L for plain cement concrete (1:3:6), type C2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry (1:2:4), type B1 (using 20mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar (1:6), uncoursed, well bonded, bedded and solidly hearted, complete all as specified and as directed.
M&L for plain cement concrete (1:3:6), type C1 (using 20 mm graded crushed stone aggregate) as in bed blocks for grouting hold fasts, coping, filling in pressed steel chowkat or similar work including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
S&F of PVC (SWR) pipes single socketed 75mm bore, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed.
M&L for hand packing (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level using broken stone boulders, complete all as specified and directed.
M&L for raised pointing to block masonry, uncoursed or brought upto courses in CM (1:4), complete all as specified.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of white wash on walls, complete all as specified and directed.
M&L for chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and no pigments over and including 15mm thick screed bed or bedding layer in cement mortar (1:6), complete all as specified and directed.
M&L for plain cement concrete (1:4:8) bed, type D2, (using 40mm graded stone aggregate) to drain pipes 100mm / 110mm bore including packing under, and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed.
S&F of PVC (SWR) pipes single socketed 110mm bore, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed.
M&L for brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:4), complete all as specified and directed.
M&L for providing precast cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate) as in landings, cover slabs (for man holes, drain etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces with plain fair faces, including chamfers, weatherings, throating etc. and set in cement mortar (1:4), complete with joints to match the surface, complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surface in cement mortar (1:4) on internal wall of manholes finished even and smooth (without using extra lime or cement), complete all as specified and directed.
M&L for rendering 10mm thick on block concrete masonry walls or concrete surfaces in cement mortar (1:6), finished even and smooth without using extra cement complete all as specified.
M&L for preparation of new plastered or unplastered surfaces of walls and applying three coats of white wash on walls, complete all as specified and directed.
Supply only integral water proofing compond, all as specified and as directed.
S&F of 110 mm bore PVC (SWR) bend any radius with access door complete all as specified and directed.
M&L for plain cement concrete(1:3:6), type C2 (40 mm graded stone aggregate) in surface channels and drains, complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds mitered / stopped ends etc., all as specified and directed.
Add or deduct for each 25 mm girth or part thereof over or under 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc., complete all as specified and directed.
Supplied and fixed of 25 mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed.
Supplied and fixed of 40 mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed.
S&F of rotational moulded polyethylene water storage tanks of capacity 500 litres (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-l and directed.
S&F of GI tubing of 25 mm bore medium grade ISI Marked laid in trenches/laid under floor on ground including all fittings such as elbow, union, reducer, tees, bends etc and short length, complete all as specified and directed.
S&F of GI tubing of 40 mm bore medium grade ISI Marked laid in trenches/laid under floor on ground including all fittings such as elbow, union, reducer, tees, bends etc and short length, complete all as specified and directed.
S&F of 25 mm bore ball brass valves, high pressure, with polythene float and flynut screwed for iron pipe or brass ferrule and fixed, complete all as specified and directed.
Taking up or down 40 mm or 50 mm bore steel tubing and connections, cutting existing steel tubing for alterations or additions (Each cut measured) and screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector) including cleaning and refixing, complete all as specified and directed.
M&L for point wiring with 1.5 Sq.mm (nominal area) PVC insulated sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC conduit not less than 20mm dia (concealed), medium grade with all necessary fittings, concealed wiring for light / Fan / Bell / 5 pin socket outlet on independent board, point controlled by one switch including 1.5 Sq mm PVC FRLSH insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.60 mm thick pressed steel terminal boxes including flush metal box 2/4/6/8/12 module with module inner and outer plates for mounting moduler switches, socket outlet, regulator etc. with 3 mm thick laminated bakelite sheet cover for housing switches, socket outlet, regulator etc., complete all as specified and directed including testing on completion. Notes: (a) Proper colour coding of PVC insulated copper wire should be maintained as red/yellow/blue wires for phases, black wire for neutral and green wire for earth. (b) Two run of 1.5 Sq.mm for phase and neutral and one run of 1.5 Sq.mm for earth wire. (c) Concealed type in permanent bldg and surface type in temporary bldg or as directed.
M&L for point wiring with 1.5 Sq.mm (nominal area) PVC insulated sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC conduit not less than 20mm dia (concealed), medium grade with all necessary fittings, concealed wiring for one 3 pin socket outlet 5 amps on the same board with other switches including 1.5 Sq mm PVC FRLSH insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.60 mm thick pressed steel terminal boxes including flush metal box 2/4/6/8/12 module with module inner and outer plates for mounting moduler switches, socket outlet, regulator etc. with 3 mm thick laminated bakelite sheet cover for housing switches, socket outlet, regulator etc., complete all as specified and directed including testing on completion. Notes: (a) Proper colour coding of PVC insulated copper wire should be maintained as red/yellow/blue wires for phases, black wire for neutral and green wire for earth. (b) Two run of 1.5 Sq.mm for phase and neutral and one run of 1.5 Sq.mm for earth wire. (c) Concealed type in permanent bldg and surface type in temporary bldg or as directed.
M&L for point wiring with 2.5 Sq.mm (nominal area) PVC insulated sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC conduit not less than 25mm dia (concealed), medium grade with all necessary fittings, concealed wiring for one 3 / 5 pin socket outlet, 5 / 15 amps on independent board, point controlled by one switch including 2.5 Sq mm PVC FRLSH insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.60 mm thick pressed steel terminal boxes including flush metal box 2/4/6/8/12 module with module inner and outer plates for mounting moduler switches, socket outlet, regulator etc. with 3 mm thick laminated bakelite sheet cover for housing switches, socket outlet, regulator etc., complete all as specified and directed including testing on completion. Notes:- (i) Proper colour coding of PVC insulated copper wire should be maintained as red/yellow/blue wires for phases, black wire for neutral and green wire for earth. (b) Two run of 2.5 Sq.mm for phase and neutral and one run of 2.5 Sq.mm for earth wire. (c) Concealed type in permanent bldg and surface type in temporary bldg or as directed)
S&F of switch piano, flush type single pole, one way, 5 Amps / 6 Amp, 240 Volts, all as specified and directed.
M&L for switch socket combination 2 in 1, 5 Amps / 6 Amps flush type, 240 Volts, all as specified and directed.
M&L for switch socket combination 3 pin 5Amp / 16 Amp, 5 in 1, flush type, 240 Volts, all as specified and directed.
M&L for ceiling rose, 3 phase/PVC/ polycarbonate, isolated body, three terminal, 240 Volts, all as specified and directed.
S&F of sub main wiring with two single core 2.5 Sqmm PVC (FRLSH) copper conductor, insulated multistranded unsheathed cable medium grade including PVC conduit concealed of required size (not less than 32mm) conforming to IS 2079-1973 with accessories for sub main connection including 2.5 Sqmm PVC (FRLSH) insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified and directed. (Note:- Three runs of 2.5 sqmm PVC FRLSH copper conductor shall be measured as one unit length).
M&L for lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings, complete all as specified and directed.
S&F of 9W LED lamp suitable for B-22 holder base, system efficency should be > 85 lm/ W. PF > 0.9. The lamp slould have cool daylight colur temp of 6500K, lumen output >800 lm, all as specified and directed.
Supply and fixing of LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, all as specified and directed.
Supply and fixing of 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole (SP) and current carrying capacity of 5 To 32 AMP in the MCB DB complete with connection testing and commissioning, all as specified and directed.
Supply and fixing of sheet metal enclosure, double door for MCB DB's, 8 way single pole & neutral (SPN) and current carrying capacity of 200 amps rated bus bar suitable for 240 Volt, AC, 50Hz, complete all as specified and directed.
Supply and fixing of sheet metal enclousers for DB's with MCB incomer suitable for triple pole and neutral (TPN), double door, 4 Ways, built-in 200 Amps busbar for neutral link suitable for 415 Volts, AC, 50 Hz, complete all as specified and as directed.
Supply and fixing of 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 AMP, in the MCB DB complete with connection testing and commissioning, all as specified and directed.
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of triple pole and neutral (TPN) and current carrying capacity 40 to 100 Amps in the DB, complete with connection testing and commissioning, complete all as specified and directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm × 60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron or steel earth lead wire 4.0mm dia size by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES SSR Part-I, connected to earthing test point all as specified or indicated including testing on completion, including necessary excavation and earth work in any type of soil, GI pipe 20mm dia light grade for watering and GI 15mm dia light grade pipe for protection of earth wire etc. upto test point, PCC chamber with PCC cover in cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to DB as indicated, complete all as specified and as directed. Notes: Contractor should conduct necessary test such as earth continuity, earth resistance test in presence of Engineer-in-Charge.
Supply and fixing of building security light fittings suitable for LED 30 Watts luminaire with Housing Pressure die-cast aluminium alloy for housing (heat sink) with IP66 & top opening for easy maintenance, Oerating voltage range : 140-270 V, system power consumptionnot more than 25W 240V, lumen output not less than 2500lm, CCT= 5700K, system efficacy> 100 including bracket made out of 25mm dia light grade GI pipe not less than 1.2 mtr long bend to shape duly fixed with MS clamps, nut, bolts, etc including connecting up with 3.0 core, 1.5 sqmm multicore copper conductor PVC sheathed from connector to ceiling rose including taking down old u/s light fitting, complete all as specified and directed.
Supply and fixing of decorative, wall mounting fixture in durable plastic body & designer mesh in gold finish suitable for 14W retrofit CFL including necessary connection with 0.5 sqmm PVC shethed 3 core copper cable and 14W LED light, complete all as specified and directed.
Supply and fixing of LED light fitting 1x9 Watt / 1X10 Watt bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, all as specified and directed.
Supply and fix electric water heater(Geyser), storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc, complete all as specified and directed.
Supply and fixing of PVC connections 15mm size with PTMT nuts of length 300mm, all as specified and directed.
Supply and fixing of hot water outlet connection made of brass chromium plated with union rubber washer suitable for 15 mm bore GI pipe for hot water, all as specified and directed.
S&F of 15mm bore dia bib taps, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed.
Supply and fixing of 15 mm bore dia stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, all as specified and directed.
S&F of sub main wiring with two single core 4.0 Sqmm PVC (FRLSH) copper conductor, insulated multistranded unsheathed cable medium grade including PVC conduit of required size with accessories for sub main connection including 4.0 Sqmm FRLSH insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly, all as specified and directed. (Note: Three runs of 4.0 sqmm PVC FRLSH copper conductor shall be measured as one unit length).
S&F of sub main wiring with two single core 6.0 Sqmm PVC (FRLS) copper conductor, insulated multistranded unsheathed cable medium grade including PVC casing and capping of required size (not less than 32mm) conforming to IS 2079-1973 with accessories for sub main connection including 6.0 Sqmm PVC (FRLS) insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified and directed. (Note: Three runs of 6.0 sqmm PVC FRLS copper conductor shall be measured as one unit length).
Supply and fixing of plastic body exhaust fan 200/250 mm sweep and self opening louvers for protgection from birds & rains water 200-240Volts AC supply, connecting up including provision of cable from ceiling rose to fan, complete all as specified and directed.
Excavation in trenches/ foundation in soft / loose soil not exceeding 1.50m wide and not exceeding 1.50m deep for laying of LT / HT under ground cable/ pole foundation and getting out including forming bottom surface to required level or slope, complete all as specified and directed.
M&L for sand cushioning to under ground cable in layers of 23cm thick (8 cm before laying the cable and 15 cm thick after laying the cable) in trenches complete all as specified and directed. Note :-Puned layers of 18 cm thick sand shall measured only.
Supply and laying of old size sub-class ’B’ bricks (designation 75), laid flat equal to width of bricks, perpendicular to under groung cables over the dry sand cushioning, for cable protection, complete all as specified and directed.
Supply and laying of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, 3.5 core, cross-sectional area 35 sq. mm, complete all as specified and directed.
Material and Labour for 25 mm bore GI tubing light grade in repairs incl. accessories for protection of cables on poles / under road crossing, complete all as specified and directed.
Supply and fixing of MCCB 100 Amps 4 pole, 16 KA breaking capacity with sheet metal enclosure, complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cm × 60cm × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to using galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-l connected to earthing test point all as specified or indicated including funnel with GI medium grade watering pipe 20 mm bore with wire mesh, 40 mm bore GI light grade pipe for protection of earth lead conductor from earth plate to terminal block box, providing charcoal and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with concrete pit in PCC 1:3:6, type C1, 50 mm thick pre cast RCC 1:2:4 type B1 cover slab reinforced with 8 mm dia reinforced bar 15 cm C/C and earth lead handle protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50m including testing on completion, complete all as specified and directed.
Note 1:- (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum / amendments and general condition of contracts before entry / quoting the rates. Note 2:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount.
M/S JAYSHREE CONCERN (BID ID -3048892)
SANJAY SAW MILL (BID ID -3047954)
S K ENTERPRISES (BID ID -3047474)
MS MAYA PRAKASH GOEL AND SONS (BID ID -3048902)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .