Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 CrAccepted-AOC 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400708 | THANE | MAHARASHTRA | 400708 | ₹3.5 Cr Quoted ₹3.6 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹3.8 Cr+₹16.0 L (4.42%)Rejected-Finance ONLOOKER BUILDING 3RD FLOOR 25 SHRI P M ROAD FORT MUMBAI 400 001 | MUMBAI | MAHARASHTRA | 400001 | ₹3.8 Cr+₹16.0 L (4.42%) | L2 | Rejected-Finance Being other than Lowest |
| 3 | Rejected-Technical NOT AVAILABLE | - | - | Rejected-Technical Below two Class |
Tender Value
₹3.9 Cr
EMD Value
₹4.7 L
Closing Date
5 Jun 2020, 6:00 pmClosed
CWE NW Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
SPECIAL REPAIRS TO BUILDING R 11 AT NAVY NAGAR, UNDER GE NW NAVY NAGAR COLABA MUMBAI
2020_MES_336845_1
8190/CWE(NW)/MUMBAI
Open Tender
Civil Works
Item Wise
360 days
GE NW Navy Nagar
SPECIAL REPAIRS TO BUILDING R 11 AT NAVY NAGAR, UNDER GE NW NAVY NAGAR COLABA MUMBAI
7 documents required · 7 mandatory
₹2,000
Yes
GE NW Navy Nagar
₹4.7 L
Yes
14 Jul 2020
1 Apr 2020
8 Jun 2020
1 Apr 2020
5 Jun 2020
6 May 2020
1 Apr 2020 - 21 Apr 2020
Amount
Taking down plaster (Chipping off ) removing ,carefully Loose plaster by low impact Hammer without damaging the structure and cleaning and disposal of debris out side the premises complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Chipping ,removing carefully concrete work by low impact hammer ,breaker without damaging the structure & cleaning and disposal of debris out side the premises etc complete all as specified and directed. Hard concrete shopuld not be removed by force.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Dismantling, Removing,Carefullly Concrete work by low impact Hammer ,Breakar without damaging the structure & cleaning and disposal of malba out side the premises etccomplete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labourfor clean existing reinforcement with wire/ rotary wire brush, making the surfaces free from loose material dirt etc. complete, Applying two coats of alkaline rust converting primer FEOVERT of Krishna Conchem of Roff rust cleaner of Piddilite or Dr Fixit Rust removal or sholirust of STP Ltd. on the rebars,including cleaning the reinforcement ,wirebrushing to remove loose rust spalls, wash the rebars with clean water within 3 min and wipe it dry.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labourfor providing and fixing additional steel bar or stirrups of diameter in variuos structural elements like columns,beams and foundations including drilling,bending and fixing the bars with epoxy putty etc. complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labourfor carry out application of ‘Bi-polar migratory corrosion inhibitor' EPCO-KP-100 on concrete surface. This inhibitor has migratory kind of property which permits the material to migrate to a virtual extent of 100 mm, through pores of concrete, inhibiting the corrosion and de-passivating the Electro-chemical reaction. It has property to attack anode as well as cathode, which is purely alkaline in nature (pH-9.5), so it has no carcinogen activity with concrete complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labourfor applying two coats of anticorrosive Treatment to Reinforcement by application of two coats of anti-rust protective coating in the form of Acrylic Polymer with a minium splid content to 40% solid mixed with cement in 1:1.5 proportion ( 1 part polymer and 1.5 part cement) on rebars after cleaning of rust scales with time interval of minimum 4 hours between each coat by brush as per manufacturers instruction. Anti-rust protective shall be procured from one of manufacturer given below. (Make :- Fosroc/Sika/BASF/Krishna Conchem)
Height upto and including 4th floor.
5th floor to upto and including 7th floor.
Material and labourfor providing and applying structural grade EPIBOND-21-LP prior to application of any type of mortar plaster conforming to ASTM-C-882-91 (Arizona Slant Shear Test) to ensure bond between old concrete and new concrete complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
Material and labourfor providing and applying structural grade EPIBOND-21-LP prior to application of any type of mortar plaster conforming to ASTM-C-882-91 (Arizona Slant Shear Test) to ensure bond between old concrete and new concrete all complete as directed by Engr-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labourfor providing and applying jacketing around columns,beams,slabs,chajjas etc with Micro concrete (molith-MC) M40 including all lifts, shuttering,drilling holes and fixing shear anchor as per specification all complete .Note: Reinforcement shall be measured and paid separately (Rates including jacketing, formwork and micro concret)
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labourfor building up the profile of structural members by using latex B2 modified air cured mortar system in damaged areas (1Cement-3 part graded cleaned pre-packed river sand 10% latex mortar by weight of cement-0.5 w/c ratio) upto 20 mm to 40 mm thickness including leveling profiling and removing and cleaning existing vegetation growth in structural and Non structural items complete all as specified and directed. (Make :- Fosroc/Sika/BASF/Krishna Conchem)
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labourfor providing and Casting in position a mix of (M30 Grade) made clean sharp aggregates 10 mm down along with addition of Non shrink admixure including transporting, mixing, laying, curing complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labourfor centering and shuttering including struttings, propping etc. and removal of formwork in 12 mm thick plywood, including application of shuttering oil, etc. for fair finished surfacecomplete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Removal of existing water proofing treatment of the roof, cleaning with wire brushes etc including demolition of PCC padding of any description and in any position complete all as specified and directed. Note :- Work to be carried out above 7th floor.
Material and labourfor Plain cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) mixed with Shali Plast LW+ of STP/Pidilite URP of Dr. Fixit or Equivalent and appoved as per manufactures instruction. Before laying concrete surface shall be cleaned and a bond coat of slurry with Shali Crete URP (of STP) or quivalent with cement to be applied. Alll cracks in slab to be openend in 'V' groove and filled with Shali Fix RMC a Polymer Morter of STP/ equivalent complete all as specified and directed. Note :- Work to be carried out above 8th floor.
Material and labour for 20mm thick rendering in CM 1:4 with the addition of Shaliplast LW+ @ 200ml per bag of cement on fair faces of brick or concrete surfaces complete all as specified and directed Note :- Work to be carried out above 8th floor.
Material and labour for protecting the roof including parapet wall with water proofing coating , complete as specified below: (a) Clean the surface and apply one coat of primer (STP Shali Urethane BTD diluted in water in 1:1 ratio and applied @ 400 gm/sqm OR Dr, Fixit primeseal diluted in water in 2:1 ratio and applied @ 7-8 sqm/ltr) and allows to dry for 6 to 8 hrs. (b) Apply first coat of water proofing coating over primer surface (Shali Urethene BTD with non butuminous bleding of STP Ltd. @ 1 Sqm/Ltr without dilution OR Dr. Fixit New Coat without any dilution @ 2 Sqm /Ltr) (c) Lay Non woven fiber glass mesh (Reinforcement of Shali Geo Text 40/50 gsm of size 2.5mm x 2.5mm) or equivalent with overlap of 50 mm on both direction while the first coat is still wet. (d) Apply second coat of water proofing coating as per manufactures instruction after 6-8 hrs of drying of first coat. (e) Apply third coat of water proofing coating (as per manucturer instruction) after 6-8 hrs of drying of second coat The total thickness of 1 to 1.2mm must be achieved after 7 days of air cure. Note : 1) The colour of each coat shall be as directed by GE. 2) The work shall be carried out by authorised applicator only 3) Water proofing to rain water spouts to be done as per manufacturer instruction
Material and labourfor Sand Face polymer modified Plaster in patches (25 mm thick) in C.M. ratio 1:4 in two coats, backing coat 15 mm thick over 10 mm thick finishing coat plaster including Drip mould/ Bands / Pattas etc. (parapet wall) complete as per the instructions and as per our standard technical specification manual or as instructed by the Engineer. Note :- Work to be carried out above 8th floor.
Material and labour providing and injecting chemical emulsion for post construction anti termite treatment along the external wall below concrete or masonary apron using chemical emulsion at 2.25 litre per linear meter including drilling and plugging holes etc with white cement and match the surface to existing apron complete all as specified and as directed by Engineer-in-Charge.
Material and labour for treatment of soil under existing floors in junction with wall (internally) using chemical emulsion @ 1 litre per hole at 300mm center to center and 300mm deep including drilling and plugging 12mm dia holes with cement mortar 1:2 or white cement to match the existing floors complete all as specified and directed
Material and labour for post construction treatment of voids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and directed
Material and labour for post construction treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and directed.
Material and labour for plastering 20mm thick in two coats 15 mm Backing coat in CM 1:4 and 5 mm thick setting coat in CM 1:3 using WPC of approved make on Brick or concrete surfaces with recrene finish complete all as specified and directed. Note :- WPC shall be measured & paid seperately.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply only integral water proofing compound of approved make as per ISI.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labourfor preparation applying one coat of primer and two coats of chemical waterproofing treatment(601 raincoat of Pidilite or equivalent) on newly plastered surfaces wall & Chajja, terrace & Parapet wall; such as Flexcoat, Beckcoat Exshield etc or equivalent including filling of cracks in walls/concrete with "Crack- X" of Pidilite or equivalent complete as per manufactures Instructions complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labourfor preparation of walls & applying two coats of chemical waterproofing treatment(601 raincoat of Pidilite or equivalent) on old existing surfaces of wall & Chajja, terrace & Parapet wall; such as Flexcoat, Beckcoat Exshield etc or equivalent including filling of cracks in walls/concrete with "Crack- X" of Pidilite or equivalent complete as per manufactures Instructions complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Taking down cement plaster, any description on brick or stone walls, etc including racking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for rendering 10 mm thick in CM 1:3 on ceiling finished even and smooth complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for preparation of newly plastered surface of ceiling and applying three coats of white wash complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for preparation of old surfaces of ceiling and applying two coat of white wash on old plastered wall surfaces complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for rendering 15mm thick in CM 1:6 on fair faces of brick wall /concrete finished even and smooth with sagol finish etc complete all as directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labourfor preparing newly plastered or unplastered surface and applying two coats OBD over one coat of wall priming paint over 1 mm thick wall care putty all complete incl necessary scaffolding complete.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Complete removal of existing treatment from wall surfaces by scrapping, washing & applying two coat of Oil bound distemper of approved make on wall over a coat of wall priming paint over a coat of Birla white putty on plastered surface and filling the surface inperfections such as holes, dirt, fine cracks all complete including preparation of surfaces complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Writing letter or figures n exc 30 cm high (Block,Roman, Italic or Indian) per cm height of letters complete all as specified and directed
Dismantling of MS grill and MS steel door of any description and position etc complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for fabrication of framed work as MS grills. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars barred iron doors, ladders framed balusters, walk ways, railings, framework of water tanks and similar work conform to Fe 290 Gde-E-165 & fixed in position complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in repairs MS plain black sheet 1mm thick in for covering to door shutters, covering to door chowkats (frames), chulla hood, water tanks, water troughts, ducts, cut to size edges bedded if directed, holes punched, including round headed scres, clouts nails or rivets and fixed to wood or steel members, etc with plain 40mm lap joints or welded/riveted seams including, turning up mitred angles, stopped ends, outlet etc fixed complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for Preparation of new or previously untreated surfaces of steel or steel based materials of any description not other wise described, over 10cm width or girth and applying one coat of red oxide primer and two coat of synthetic enamel paint complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for Welding in repairs n.exc 2.5 cm in length. Thickness of metal to be welded Exc. 6mm but n.exc 9 mm complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for preparation of old painted surfaces of steel or steel based materials of any description not other wise described, over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of anti-rust priming coat complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for anodised aluminium sheeting 22 gauge thick fixed in repairs as in crumple section complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Demolition of lime concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Treatment of sunken floor slab comprises of the following specifications and all as specified (i) Material and labour for cleaning of the sunken /lowered portion of the RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chiesel out any mortar sticking to the surface and brooming / washing completely. 40 mm avg thk pcc 1:2:4 type B-0 using 12.5 mm graded aggregate as in padding conc to achieve proper slope including 50 mm dia 350 mm long medium grade GI pipe spouts with wire guage on inside mouth to be fixed. (ii) Rendering of uneven surfaces with 6 mm thick CM 1:4 mixed with integral WPC @3% of weight of cement consumed. fill it with water and check dampness and seepage. where dampness and seepage noticed nozzles shall be fixed and grouting carried out( WPC shall be msrd & paid separately). (iii) All junctions points of side walls where CI/GI pipes are passing through shall be sealed with epoxy putty . (iv) After drying putty wash the slab and sides of sunken portion with water and make it clean and clear. (v) Material and labour for applying two coat of polymer modified cementious water proofing coating as per manufactures instructions to bottom and vertical sides up to finished flooor level +100 mm height. The thickness of two layer shall be 1 mm. When the second layer is still sticky , coarse sand spry shall be carried out or vertical and bottom surface of the sunken portion all as specified and directed. (vi) Plaster the bottom and sides up to bottom of the skirting with minimum 20 mm thk cm 1:4 mixed with integral WPC 3 % of cement consumes as per manufacures specification including rounding of corners and junctions sloping towards spout ( WPC shall be msrd and paid seperately. Note:Test the water proofed area (ponding test) by filling water for atleast 72 hours and tested for leakage seepage and to the entire satisfaction of GE . Test shall be done in presence of reps of PMG and record for each sunken slab shall be maintained. the treatment shall be carried out by authorised applicators of chemicals. (vii) All pipes laid in sunken portion shall be covered with 50 mm thk PCC 1:3:6 all around after painting with anticorrossive black japan paint. (viii) Height up to and including 8 th floor
Material and labour cement concrete 1:7:12 F2 type with with 40mm graded stone coarse aggregate in sunken floor all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for CI Floor trap dia of outlet 75mm with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for CI Nahani trap dia of outlet 100/75mm fixed in repairs including jointing to waste pipe in runlead complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix for PTMT grating doom over Nahani trap and floor trap of 100mm Dia
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for non skid ceramic tiles coloured of size 300x300x6 to 7mm thick laid in floors over cement mortar, screeding, set and jointed in white cement mixed with pigment including bedding layer of mortar 20mm thick in CM 1:4 for laying floor finishes complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for coloured glazed ceramic tiles 300 x 200 x 7mm on vertical surfaces set & jointed in neat cement slurry and pointed in white cement mixed with pigment over backing layer of 10mm thick in CM 1:4 complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for vitreous china wash down water closet semi padestal pattern (Anglo-Indian type) white (excluding fixing bolts, flushing cistren and flush pipe) with 'P' or 'S' trap complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix for plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminisied hinges devices complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix for aluminium anodised 20mm dia, D type, 60cm long tubular towel rail complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix for Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size (flat back or angle back type) including cutting for and pinning ends of brackets or erecting stand complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix for 32 mm dia., Waste fittings, brass chromium plated for glazed ware sinks, wash basins etc., with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix for pillar tap 15mm bore, cast copper alloy fancy type chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in repair PVC valveless, syphonic action type, flushing cristern, low level, white, 10 ltr capacity with inlet, ball valve, float and handle including brackets complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix for flush pipe of polyethylene of low or high density for low level cistern.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix 32mm dia LDPE PVC waste pipe of pressure rating 6 kgf/cm2 fixed complete to for WHB includding socket & screw complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 of 40 mm fixed complete to wall, floors for drain out the waste water in Kitchen Sink complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in repair sink with drainage board made of stainless steel 1mm thick kitchen or laboratry with plugs, washers and wastes; including beading in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mmX460mmXbowl size 410mm X 330mmX160mm complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Demolition of Stone slabs and tiles laid bedded and pointing in any mortar of any description or thickness in floors, aprons complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including bedding layer of mortar 20mm thick in CM 1:4 for laying floor finishes complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for machine cut Kota stone ( greenish colour, mirror polished) slab flooring 18 to 20 mm thick over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of slab incl rubbing and mirror polishing, over & incl 20mm thick screed bed in CM 1:6 complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
All as per item No 177 above but as in skirting over & incl backing layer of 10mm thick in CM 1:4 complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for machine cut Kota stone ( greenish colour, pre polished) slab in one piece as in cill /staircase treads flooring 18 to 20 mm thick over 15mm thick cement screed bed laid in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of slab incl rubbing and polishing complete all as specified.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
All as per item No 183 above but as in riser(should be one piece) over & incl 10mm thick rendering in CM 1:3 complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Demolition of brickwork built in cement mortar or cement lime mortar including all quoins,arches, pillars complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour brick work with subclass B brick straight or curved on plan exc. 6m mean radius , built in cement mortar 1:4 complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for machine cut cudappah stone 20-25 mm thick over base,laid and jonted with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing as in shelves complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Cutting chases,pinning in ,making good to facing where required and pointing in cement mortar 1:3 to ends or edges of shelves etc,and making good ,cutting n exc 10 cm girth in brick walls complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for plain cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in roof kerbs, or mud stops, levelling coarse of roof, rounded of chamfered on edge, average thickness not exceeding 75mm complete all as specified and directed. The work is to be carried out above 14th floor of existing bldg complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for granite (of any type) slab 18 to 20mmthick machine cut,bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete for kitchen plateform complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for polishing of old / existing kota stone flooring complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Taking down chowkats with shutter (without taking shutter from the frame) not exc 1.5 sqm each complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Taking down chowkats with shutter (without taking shutter from the frame) exc 1.5 sqm each but not exc 4 Sqm each complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Dismantling wrought iron or mild steel work (windows guard bars) of any description not otherwise described complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fixin for machine cut kota stone slab single piece length as in jambs/cills of windows 18-20mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing (Note : kota stone single pice of Cill will be fixed in two steps) complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for Screed bed or bedding layer of mortar 20 mm thick in CM 1:4 for laying floor finishes complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Rounding to edges of stone slabs one edge,such as in steps, windows frame, cooking plateform,and other similar situations complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for extra two Nos grooves 2x2mm over stair case treads complete all as specified and directed
Material and labour for cutting holes in brick / stone walls in cement mortar exc half & n.exc. One brick depth of embedded portion of hold fast and making good in cement concrete 1:2:4 type B1 or in cement mortar 1:3 and finished surfaces feven and smooth complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labourfor PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in copings, bed blocks etc including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix for powder coated anodised aluminium frame/track or shutters for windows, ventilators etc. with one or more rebates including joining cleat for fixing etc.fixed or sliding type/louvered window or ventilator without sash bar, aluminium including necessary joining cleats, glazing clips, rubber packing, anodised alumnium snap beading, screws complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in aluminium alloy wire mesh 0.45 mm nominal dia of wire and average width of aperture 1.4 mm fixed with aluminium wire staples all complete to alumn shutters complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix 4 mm thick figured glass pin headed type and glazing with aluminium and neoprene beads in square not exc 0.5 sqm in each pane all complete.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in 4mm thick plain sheet glass ordinary quality and glazing with aluminium and neoprene beads in square n. exc 0.5 sqm in each pane complete all as specified and directed
Height upto and including 4th floor.
th floor to upto and including 8th floor.
Material and labour for aluminium anodised grill with suitable aluminium anodised frame section manufactured by M/S Deco grill pattern DG-104 (10mm dia and aparture 75mm) complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for high strength aluminium drapery rod with powder coated paint thickness 40-60 microns/electric resistance welded MS pipe with corrugated PVC extrusion having outer dia of 19/20 mm & inner dia 16 mm , Rings made of ABS plastic Decorative finials of ABS plastic in matching colour & installation brackets of galvanised steel powder coated paint in matching colours (Make:- MAC- sleek line type I model/VISTA Levolor SoffioI) complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for powder coatd aluminium fancy types domes cum brackets (20 mm dia) fixed to both ends of the curtain rod complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Taking down shutters of any description n exc 1 sqm each complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
All as per Item No 259 above but exc 1 sqm and n exc 2 sqm each complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamvered, put together with glue pinned at joints complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labourfor preparing surfaces of wood and wood based materials, and treating back of chowkats with tar or coal tar black paint complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labourfor preparing surfaces of steel and iron work, and treating small articles such as holdfast with tar or coal tar black paint complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix for mild steel hold fasts, wall ties and similar small articles conforming to Fe 410-0 or Fe310-0 complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for providing PCC 1:2:4, type B1(20mm graded aggregate) for hold fasts complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix 40mm thick flush shutter, solid core construction with block board core and plywood face panels, commercial type on both sides complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix 35mm thick second class hard wood factory made plain framed panelled shutters (two panes) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board medium density with commercial veneering both face. The size of rail shall be as per IS 1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
All as per item No 283 above but 30mm thick shutters for cupboards.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in second class hard wood factory made glazed and skeleton shutters 35 mm thick, open rebatede and prepared to receive glass, gauze etc (without sash bars), edge of framing plain chamfered of rounded, fitted with cut and mitred beads for securing glass etc. size of members of shutters shall be as specified in SSR Part I, section 8.20 (a) complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix 25 mm thick block board, grade 1 quality, exterior grade, decorative type with decorative face veneer on one face fixed with screws to timber frame work of width n.exc. 25 cm in shelves or built-in cupbords, almirahs and similar work with lipping patti complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in magic eye fancy type of brass for door including drilling cutting of holes and making good complete all as specified and directed
Supply and fix in teak wood lipping 6mm thick and 25 to 40mm wide around the flush shutter, panelled, glazed or gauzed joinery, re-newed, including mitres complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in Beads, straight (any size) 2nd class HW for around the prelaminated partical board, panelled,glazed or gauzed joinery, re-newed, including mitres complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in 12 mm thick Plywood, grade BWR, type BB, fixed with screws to timber frame workin shelves or built-in cupbords, almirahs and similar work with lipping patti complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in hasp and staple safety type,aluminium anodised including bolt to hinge plate and fixed with screws 150mm size complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 2omm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of fplain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles. & rails with suitable PVC sheet beading, and joined together with sovent cement, suppling & fixing in the frame at site complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & direction.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in 100mm size stainless steel butt hinges (ISI Marked) complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in 75 mm size stainless steel butt hinges (ISI Marked) complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
All as per item No 314 above but fixed in repair.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
All as per item No 317 above but fixed in repair.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix extruded aluminium alloy handles 150mm size, fabricated type, anodised.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
All as per item No 326 above but fixed in repair.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in Aluminium, anodised, barrel tower bolts 150mm size of extruded section and fixed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
All as per item No 332 above but fixed in repair.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in repairs Aluminium, anodised, hasp and staple 150 mm size, safety type with MS hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in Aluminium alloy, anodised, sliding door bolt 300mm size with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast alumimnium alloy and fixed complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
All as per item No 341 above but fixed in repair.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in Floor door stopper of Aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, Overall length of cover plate 150 mm complete all as specified and directed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Alll as per item No 347 above but fixed in repair.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in aluminium wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, wooden beedings to doors complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
All as per Item No 353 above but fixed in repairs.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for Preparation of new or previously untreated surfaces of wood or wood based materials of any description not other wise described, over 10cm width or girth and applying one coat of pink primer and two coat of synthetic enamel paint complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Material and labour for Preparation of old painted surfaces of wood or wood based materials of any description not other wise described, over 10cm width or girth and applying two coat of synthetic enamel paint complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Taking down CI soil/waste/vent/rain water pipes including all fittings like shoes bends swan necks etc of any dia complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in CI soil/waste/vent pipe in any length with ears 100 mm bore (sand cast) in any length with cement joints fixed to walls complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
All as per item No 368 above but except pipe.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in CI bends (any radius) for soil/waste pipes 100 mm bore diminishing pieces or tapers on walls complete all as specified.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in CI branch pieces single 'Y'.'T' (equal or unequal) ordinary or inverted (spigot or socket type) with parallel branches for 100mm bore pipe with ovel access door complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in CI soil/waste/vent pipe in any length with ears 75mm bore (sand cast) in any length with cement joints fixed to walls complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
All as per item No 380 above but except pipe.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix CI bends (any radius) for soil/waste pipes 75mm bore diminishing pieces or tapers on walls complete all as specified.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix CI branch piececs single 'Y'.'T' (equal or unequal) ordinary or inverted (spigot or socked type) with parallel branches for 75mm bore pipe complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Taking down PVC rain water pipes including all fittings like shoes bends swan necks etc of any dia complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in PVC (SWR) pipes 150mm bore single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in PVC (SWR)bends (any radius) for rain water pipes 150 mm bore diminishing pieces or tapers on walls complete all as specified and directed
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
Supply and fix in PVC covers to MS railings of stair case hand rail complete all as specified and directed
Material and labour for excavation in over areas in soft/loose soil and getting out complete all as specified and directed
Material and labour in Hard core of gauge n.exc 63mm deposited spread and levelled in layers n.exe 15 cm thick watered and rammed to a turre surfacecomplete all as specified and directed
Material and labourfor 100mm thic PCC 1:3:6 type C2 ( using 40mm graded stone aggregates) as in sub base to floors, pavements complete all as specified and directed
Material and labour for plain cement concrete colour interlocking tiles 60 mm thick having glossy finish/(colour and pattern approved by GE) strength not less than 350 Kg/Sq CM laid over and including 50 mm thick dry sand cushioning and void filled with dry and compact, including compation by means of surface vibrator, complete all as specified and directed
Removing demolished & excavated material exc 5 Km but n.exc 15 Km and depositing complete all as specified and directed
Taking down carefully copper/ aluminium point wiring ie. light, fan, socket or power/points complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of ceiling, walls, floors complete all as specified and directed
Material and labourfor point wiring with PVC insulated unsheathed single core multistranded copper conductor 1.5sqmm, 1100Volts grade cable, FRLS, passing through concealed in PVC conduit including accessories and provision of PVC modular boxes for mounting switches, switch socket, fan regulator etc, complete all as specified and directed including one run of PVC insulated unsheathed multistranded copper conductor cable 1.5sqmm (green colour) earth wire and connected to earth dolly for the following:-. Note : Circuit conductor from MCB DB to Switch boards should not be less than 2.5sqmm
One light/ fan/ E'fan point controlled by one way switch
One light point controlled by two way switch.
One bell point controlled by one push button.
One 3 pin socket outlet, 5 Amps on the same board with other switches.
One 3 pin socket outlet, 5 Amps, independent
All as per item No 408 above but with 2.5 sqmm cable for one three pin 15 Amps socket out let controlled by one switch complete all as specified and directed.
Supply and fix modular switch, 1 module, single pole, one way 6 Amps, 240V complete all as specified and directed. Make : “Legrand (Britzy)/ Anchor (Roma)/ Crabtree (Athena)”.
Supply and fix modular switch, 1 module, single pole, two way 6Amp complete all as specified and directed. Make : “Legrand (Britzy)/ Anchor (Roma)/ Crabtree (Athena)”.
Supply and fix modular switch, 1 module, single pole, one way 16 Amps, 240 Volts complete all as specified and directed. Make : “Legrand (Britzy)/ Anchor (Roma)/ Crabtree (Athena)”.
Supply and fix modular socket, 6A -2/3 pin combined 2 module, ISI marked, 240 Volts complete all as specified and directed. Make : “Legrand (Britzy)/ Anchor (Roma)/ Crabtree (Athena)”.
Supply and fix modular socket, 6/16A -2/3 pin combined 2 module, ISI marked, 240 Volts complete all as specified and directed. Make : “Legrand (Britzy)/ Anchor (Roma)/ Crabtree (Athena)”.
Supply and fix modular stepped type (5 step) electronic fan regulator, 2 module, 230 volts ISI marked and connecting up complete all as specified and directed. Make : “Legrand (Britzy)/ Anchor (Roma)/ Crabtree (Athena)”.
Supply and fix ceiling rose surface bakelite 65x50 mm with 3 terminals complete all as specified and directed.
Taking out old wooden/PVC board and disconnecting all electric connection from switches, board and supply and fix modular PVC flush box 6 module for mounting of modular switches and blank plate complete all as specified and directed. Make : “Legrand (Britzy)/ Anchor (Roma)/ Crabtree (Athena)”.
All as per Item No 422 above but of modular PVC flush box, 3 module complete all as specified and directed. Make : “Legrand (Britzy)/ Anchor (Roma)/ Crabtree (Athena)”.
All as per Item No- 422 above but of modular PVC flush box, 1/2 module. Make : “Legrand (Britzy)/ Anchor (Roma)/ Crabtree (Athena)”.
Supply and fix modular white cover plate with frame, 6 module complete all as specified and directed. Make : “Legrand (Britzy)/ Anchor (Roma)/ Crabtree (Athena)”.
Supply and fix modular white cover plate with frame, 3 module complete all as specified and directed. Make : “Legrand (Britzy)/ Anchor (Roma)/ Crabtree (Athena)”.
Supply and fix modular white cover plate with frame, 1/2 module complete all as specified and directed. Make : “Legrand (Britzy)/ Anchor (Roma)/ Crabtree (Athena)”.
Taking down old unserviceable andSupply and fix Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. Make : “Legrand (Britzy)/ Anchor (Roma)/ Crabtree (Athena)”.
Supply and fix modular bell push 5Amp shall confirm to IS-3854 of 1988, 240V complete all as specified and directed. Make : “Legrand (Britzy)/ Anchor (Roma)/ Crabtree (Athena)”.
Supply and fix bell, ding dong AC 230 Volts, single pole complete all as specified and directed.
Taking down unserviceable FTL and supply and fix slim LED integrated batten of 20 watt 4ft cool day light with powder coated CRCA decorative patti prewired complete with two Nos of PVC box of size 75x75x20mm for mounting light fittings including new ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body complete all as specified and directed. Make : C&S Cat Part No LTTB4F20WLEDEW or SZSLAMX020 of Shakti or BCLSB20WH of Bajaj
All as per Item No 431 above but of 10Watts 2 feet complete all as specified and directed. Make : “C&S Cat Part No LTTB2F10WLEDEW or SZSLAMX010 of Shakti or BCLSB10WH LED of Bajaj”.
Taking down unserviceable Bulk Head fitting and supply and fix Bulk head fitting IP-43 with die cast aluminium housing, heat resistant glass and galvanised wire guard including pin type holder with 9 Watt LED lamp complete all as specified and directed. Make : “Halonix Cat No HBH0110CFMO or BJDB100BC of Bajaj or Cat No – CG80421 of C&S”.
Taking down old Main switches/MCB DB any way, any type complete all as specified and directed
Supply and fix in MCB DB SPN confirming to IP 43-IK 09 with acrylic door, 8 way complete with din rail, Neutral and Earthing bar complete and making good the disturbed surfaces complete all as specified and directed.
Supply and fix in MCB SPN, 10 to 32Amp, 10KA, 230Volt complete all as specified and directed
Supply and fix in MCB, single pole, upto 20Amp, 10KA, 230Volt complete all as specified and directed
M&L for sub main wiring with PVC insulated, PVC sheathed, armoured, FRLSW, 1100V grade, 2 ore 6 Sqmm stranded copper conductor fixed on wall/ roof/ duct complete and connecting from meter to DBs with glands including taking out existing damaged cables and all as directed. Make : Polycab/ Plaza/ Havells/ Finolax.
Taking down exhaust fan with louvers from site and refixing the same and making good disturbed surface complete all as specified and directed
Material and labourfor earthing complete with galvanized steel earth plate electrode 60 X 60 X 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth lead wire 4.0 mm dia by mean of bolts, nuts, check nuts and washers of galvanized iron or steel upto the test point all as shown in electrical plate No.3 of SSR Part-I including PCC earth pit with CI cover, GI funnel with wire mesh, GI protection pipe of 40 mm dia for earth lead and 20mm GI pipe for watering, excavation and earth work in any type of soil, filling the pit with charcoal and common salt surrounding the earth plate complete all as specified and directed including testing on completion.
Taking down old rusted and Supply and fixing of street light bracket made from 20/32mm bore GI tubing tight grade 1mtr long, bent to required shape and fixed to pole/wall by means of 4 Nos MS flat iron clamp with nuts, bolts & washers as required for fitting to the buildings.
Taking down old unserviceable and Supply & fix LED 45 watts building security light in aluminium PDC housing, toughened glass cover in IP66 protection complete all as specified and directed.
Material and labour for Astronomical Timelite distribution board with contactor, relay and prewired, 32A, 3 pole, 230 Volt and Astronomical programmable time switch with backup of 6 years, 28 memory locations, current capacity 16 A with one CO time switches for street light complete all as specified and directed
Taking down old unserviceable and Supply, install, testing and commissioning of meter cabin panel mounted on angle iron frame 40 x 40 x 5 mm grouted on floor,cubical indoor type for 415V, 3 phase, 4 wire made out not less than 2 mm thick CRCA sheet weather, vermin proof factory fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 200 Amps rated copper bus bar (all in equal size), top and bottom cable entry with proper size glands including disconnecting cable connections and electronic meters from old meter cabin panel and fixing & connecting in new insalled panel with provisions of thimble/lugs and making provisions of vision glasses for meter readings as directed. Comprising of the following :- (a) MCCB 4 pole, 100 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 Nos,Make-Legrand/Siemens/Schneider. (b) MCB SPN 32 Amps 10 KA - 58 Nos Make-Legrand Cat No-4086 17 or eqivalent to Hager/ Schnider/ ABB. (c ) Copper Bus bar, 200 Amps Rated - R,Y,B & N - (01Set of four). (d) Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V,A,F,PF,KW,kVAR,kWH etc of make :- Legrand/Schneider/L&T/AE- 1 set. (e) Phase indicator lamp R,Y & B - (01 Set oet three). (f) S&F din type digital electronic meter including provision of new vision glass- 56 Nos (Cost of meter shall be included in above quoted rate)”. (g) Supply & fix of submain cable 2 core 4/6 Sqmm copper conductor from MCB SPN to electronic meter. (h) Making good the disturbed surface of meter cabin room if any damages occures during fixing/shifting of panel. Note :- Before fabrication of panel the contractor has to take approval from accepting officer on drawing. Note: All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimblecomplete all as specified and directed
Taking up or down GI tubing including all fitting and fixtures fixed to wall in existing position at location and remove from the site :-
15 mm bore
20 mm bore
25 mm bore
Taking up or down PPR Pipe including all fitting and fixtures fixed to wall in existing position at location and remove from the site complete all as specified and directed :-
16 mm bore
20 mm bore
25 mm bore
Supply and fix in repair/replacement of steel water tubing, galvanised, Medium grade with all fittings in shafts such as nipple, union, socket, elbow, bends, fixed to wall including necessary & capacity up to 7 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/on wall and making good the disturbed surfaces complete all as specified and directed by Engineer-in-charge.Note Work to be carried out in high rise buildings plain wall or in shafts or in terraces or inside the flats for cutting the existing GI pipe line and replace the sme with new GI pipe in short piece of full length. Make : Jindal/TATA/Bansal//Zenith
15 mm bore
20 mm bore
25 mm bore
Supply and fix in repairs Valve, stop, screwed, supplied and Installed complete for size 15 mm. Make : Seiko/GEM/Leader
Supply and fix in repairs Bib taps,cast copper alloy with crutch or butterfly handle,screwed down,screwed for iron pipe or for brass ferrule and fixed of size 15 mm dia.Seiko/GEM/Leader
Supply and fix in replacement of(HDPE) Rotational moulded polythelene Water Storage tanks cylindrical vertical with closed top of capacity 200 Ltrs with float vallve 15mm bore , hoisted and fixed in position including 03 Nos adopter, washer , inlet ,outlet over flow pipe complete all as specified and directed. Make : Sintex/Polycon/Ashish
Supply and fix in shower rose CP 125mm dia swivel suitable for 15mm bore GI tubing
Supply and fix in repairs of Bronze, pressure, reducing valve screwed ends for 25 mm bore GI pipe, suitable for a maximum inlet pressure of 20 Kg/cm2 reduced to 0.5 to5.5 Kg/cm2, valves incorporates inherent design advantages like noise free working, an metal construction, reversible double re-inforced food grade EPDM rubber (Colour coding Black) Diaphram cover, stainless steel bolts etc valve are calibrated for a maximum inlet pressure of 20 Kg/cm2. Make- Hawa/Leader/ Zoloto.
Supply and lay 3 layer (Inner antimicrobial, outer UV stablized) ISI marked , IS-15801, PPR Pipes SDR 7.4 (PN16) and PPR plain fittings in trenches/walls/celings or laying in floor complete of sizes outer dia as below :-Make : SFMC/KPT/Prince
20mm bore
25mm bore
32mm bore
Supply and fix repair hose box for keeping 2 Nos hose pipe of length 15 meter each, branch pipe.nozzle, coupling etc of MS sheet of Thickness 2.0 mm complete all as specified and directed.
Supply and fix repair rubber hose reel of 20 mm dia and 30 meter plain 2 ply rayon braided high pressure complete all as specified and directed. Make:Minimax/safex/Dunlop/Cease fire of ISI Marked
Supply and fix repair branch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090 complete all as specified and directed
Supply and fix replaicement 63 mm dia 15 meter long hose conforming to IS 636 complete with male and female coupling conforming to IS 903 complete all as specified and directed.
Supply and replacement, installation, testing & commissioning of Microprocessor based 2 wire fault tolerant loop, required loop networkable type 5 Loop (each loop accessing maximum 99 detectors and 99 modules ) fire alarm/detection control panel. The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFF respective control module whenever any alarm is triggered. The panel shall have rectifier, Loop cards, 80 character L C D unit to indicate Fire/Fault Signal with address and analog output. The Panel shall support 24 zones Addressable 2 way Talk Back fire fighter communication, in case of emergency. The panel shall have ability to get integrated with PA System for zone wise announcements. The panel shall support both Loop Powered & conventional Notification devices for emergency responses. the Panel shall support Auto learn feature. The panel should support networking up to 99 panels with maximum distance of 12 Km between 1 & last & 1.5 KM between adjacent panels on RS485. The Panel shall support IP connectivity if required to connect on LAN or WAN network. the panel shall support BMS connectivity through Barnet/Modbus The Panel Shall be Sheet Steel Painted, selaed to IP30. The Panel Shall have 24 Zones with Individual Led Indicators, expandable to 80 LED Indicators. The Panel Shall have 3 Serial Ports. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 48 hours with battery charger complete as required. And as per specifications. conforming to BS5839 Standards and Duly Approved by EN54/ LPCB/ VDS/ UL/BSA complete all as specified and directed. Voice Alarm controller with USB, MP3, AM/FM player )with 1000 watts Power Amplifier. Make :- Cease fire / Apollo / Hardik Engineers”.
Supply and fix repair Detectors Complying with and type certified to EN-45 addressable type smoke detector Photoelectric / Optical with base with self built intelligence as per IS: 11360 complete all as specified and directed. Make :- “Appollo/ Cease fire/ Vijay fire protection”.
Supply and fix repair fire hydrant flanged stand post CI of 80mm dia 1.5m height with provn of single outlet conforming to IS 908 complete all as specified and directed.
Supply and fix in repair single outlet fire hydrant landing valve100mm having 65mm outlet with lock pin wheel complete all as specified and directed
Supply and fix in repair sluice valve 100mm class PN 1.6 flanged end with high tensile stainless steel spindle ,boby made up of cast iron including all joints with rubber or fibre board ,nuts,bolts,washers complete all as specified and directed Make:Kiloskar/Leader/L&T ISI marked.
Supply and fix in repair 100mm dia ERW MS pipe and applying two coats of synthetic enamel paint over a coat of read oxide primer to pipe including necessary welding and fabrication ,supporting brackets complete all as specified and directed. Make:Jindal/Tata/Zenith/BST
Supply and fix in repair Non Return valve Flapping type rubber of dia 100 mm complete all as specified and directed.
Supply, laying & testing in repair PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 0.5 sq mm, 6 core, 1100 Volts grade complete all as specified and directed.
Disconnecting suction/delivery pipe from horizontal split casing pump set of capacity 20 HP, disconnecting cable connections and taking out Pump motor of capacity 15 KW, 2900 RPM, 3 Ph, 415 Volt, 50 Hz from building top and shift to workshop to carryout repair and after repair dismantle the motor shifting from workshop to building top and installation the pump set at original position, reconnecting pipe lines and the cable and testing complete all as specified and directed
Dismantle motor ,cutting/removing the burnt winding
Rewinding motor with supper enamelled copper windings of same gauge/turns and cleaning of slots and apply varnishing
Replacing bearing
Cleaning shaft sleeves and shaft assemble
Taking up or down GI tubing including all fitting and fixtures fixed to wall in existing position at location and remove from the site complete all as specified and directed :-
50 mm bore
80 mm bore
Supply and fix repair/replacement of steel water tubing, galvanised, Medium grade with all fittings in shafts such as nipple, union, socket, elbow, bends, fixed to wall including necessary & capacity up to 6 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/on wall and making good the disturbed surfaces complete all as specified and directed by Engineer-in-charge.Note Work to be carried out in high rise buildings plain wall or in shafts or in terraces or inside the flats for cutting the existing GI pipe line and replace the sme with new GI pipe in short piece of full length.
50 mm bore
80 mm bore
Supply and fix in repairs in existing line, gun metal gate valve with iron wheel head screwed both ends for iron pipe including fittings i.e. union, socket etc complete all as specified of following sizes :-
50 mm bore
80 mm bore
Taking down motorized valve 50mm bore from existing old GI pipe line and and re-fixing the same as new GI pipe line including electrical connection complete all as specified and directed
Supply and fix in replacement of(HDPE) Rotational moulded polythelene water storage tanks three layer cylindrical vertical with closed top of capacity 5000 Ltrs with float vallve 25mm bore , hoisted and fixed in position including 03 Nos adopter, washer , inlet ,outlet over flow pipe complete all as specified and directed
Taking out old broken air termination, single pointed aluminium rod of any dia fixed over the GI Tube with the clamps complete all as specified and directed.
Material and labour for CPT Cirprotec CPT-L ESE lightning rod with stainless steel body type advance lightning protection system in compliance with standard NFC 17-102 & UNE 21186-96, working on the principle of early streamer emission technology which will offer level 1 protection for up to 42 mtrs radius when mounted on the RCC concrete base on building at a height of 4.5 mtrs from the place to be protected including taking out old, U/S lightning rod complete all as specified and directed. Make- NIMBUS-JEF Techno or approved by GE.
Taking out old, GI tube of any dia complete.
Supply and erection of mounting structure of 4.5 mtrs height with base plate suitabe for roof mounting on RCC concrete base on building including taking out old, U/S one complete all as specified and directed. Make- NIMBUS-JEF Techno or approved by GE.
Taking out old, broken Aluminium strip of size 25 x 3mm fixed on walls/roof top with saddles and screws complete all as specified and directed
Supply and fix in single core PVC insulated and unsheathed cable with copper conductor in and including heavy duty PVC conduiot fixed with screw on wall and using cable size 1x50 Sqmm 1100 Volt grade stranded copper conductor after taking out old, U/S earthing strip complete all as specified and directed. Make of cable : Havells/Finolex/ L & T/Plaza/Anchor.
Supply and fix in 4 digital electromechanical lightning even counter in weather proof resistance including taking out old, U/S copper strip complete all as specified and directed
Taking out old, broken/unsrviceable earth testing point of any type complete all as specified and directed
Supply and fix in test link box for each downconductor in order to disconnect the earth termination system to enable measurement of resistance.
Taking out old, unsrviceable earthing complete with earting material complete all as specified and directed
Material and labour for maintainance free environment friendly earth electrode set comprising of 17.2mm dia, 3 mtrs long rod of low carbon steel molecular copper bounded for a thickness of 250 micro OHMS, highly conductive ANSI/NSF STD-60 certified carbon bound backfill compound which shall set like concrete according to BS 7430 & IEEE 80 (each bag shall contain 50 lbs) after taking out old, U/S one complete all as specified and directed . Make- JEF Ecosafe or equivalent as approved by GE.
Idustrial products India
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .