Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹82.9 LAccepted-AOC DHANBAD MUNICIPAL CORPORATION DHANBAD | ₹82.9 L | L-1 | Accepted-AOC Congratulations You have been awarded the contract for this tender |
| 2 | L-2₹83.5 L+₹64,989.29 (0.78%)Rejected-Finance | ₹83.5 L+₹64,989.29 (0.78%) | L-2 | Rejected-Finance Financial |
| 3 | Rejected-Technical GRAM BABHAN TOLI PO GIRIDIH THANA GIRIDIH DISTRICT GIRIDIH | - | - | Rejected-Technical Technical not Accept |
| Sl No | Description | Qty | Unit | UMESH KUMAR SINGH L1 | PRAVIN SINGH L2 |
|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing and commissioning of modular OT Wall and corner panels with insulated prefabricated puff Panels. The OT wall shall be constructed using GI puff panels having 0.8 mm thick GI sheets on both sides. These panels should have been produced in a double band laminator, in which two continuously moving belts carrying 120 GSM galvanized steel sheets of80 mm thickness are firmly bonded together by sprayed -in insulating foam, which hardens during the process. The core consists of rigid polyurethane foam, which has been injected under high pressure, with a minimum density of 40kg/m3. The thickness of Puff shall be minimum 40 mm. The sheet panel shall be of indigenous reputed make and be provided with manufactures test certificate. The puff panel shall be fixed to the floor with bottom track of 1.5 mm thick steel U channel section having min size of 50mm X 50mm. The bottom shall be fixed in the floor of the OT with 10mm thicknessand min. 60 mmlong SS fasteners which shall be fully threaded and power drilled The Panels of walls and ceilingshall be tied together by suitable SS coving. The individual wall panels of wall and ceiling shall be tied together by suitable SS coving. The individual wall panels shall be welded together bySS. All joints shall be filled with metal filler and shall be sand casted on site till smooth finish is obtained. Wall & panel joints shall not be visible after the final wall coating is applied. The gap between the masonry wall surfaces and the panel of the theatre shall be sufficient for the flush mounting of equipment’s. This gap shall be provided to accommodate the equipment at a latter date and to enable services, pipes conduits etc, to be run within the gap All wall-mounted equipment shall be flush mounted and sealed in operation theatre. All the sharp edges and corners shall be in radius to avoid bacterialcontamination. The wall panel design shall be such that it enables the installation and supports all equipment’s. Provision of openings required for the installations shall not affect rigidity and strength of the panel. Access boxes shall be fitted to the rear of all wall-mounted equipment to enable maintenance to be carried out from outside the operation theatre. Product should have warranty of at least 10 years. Thework should be executed as per the directions of Engineer–in-Charge. | 11.52 | Sqm | 7,500 ₹86,400 Lowest | 8,000 ₹92,160 |
| 2.00 | Supply, installation, testing and commissioning of modular OT Wall and corner panels with insulated prefabricated puff Panels. The OT wall shall be constructed using GI puff panels having 0.8 mm thick GI sheets on both sides. These panels should have been produced in a double band laminator, in which two continuously moving belts carrying 120 GSM galvanized steel sheets of The thickness of Puff shall be minimum 40 mm. The sheet panel shall be ofindigenous reputed make and be provided with manufactures test certificate. The puff panel shall be fixed to the floor with bottom track of 1.5 mm thick steel U channel section having min size of 50mm X 50mm. The bottom shall be fixed in the floor of the OT with 10mm thicknessand min. 60 mm long SS fasteners which shall be fully threaded and power drilled. The Panels of walls and ceiling shall be tied together by suitable SS coving. The individual panels of wall and ceiling shall be tied together by suitable SS coving.
The individual wall panels shall be welded together bySS. All joints shall be filled with metal filler and shall be sand casted on site till smooth finish is obtained. Wall & panel joints shall not be visible after the final wall coating is applied. The gap between the masonry wall surfaces and the panel of the theatre shall be sufficient for the flush mounting of equipment’s. This gap shall be provided to accommodate the equipment at a latter date and to enable services, pipes conduits etc, to be run within the gap. All wall-mounted equipment shall be flush mounted and sealed in operation theatre
All the sharp edges and corners shall be in radius to avoid bacterial contamination. The wall panel design shall be such that it enables the installation and supports all equipment’s. Provision of openings required for the installations shall not affect rigidity and strength of the panel. Access boxes shall be fitted to the rear of all wall?mounted equipment to enable maintenance to be carried out from outside the operation theatre. Product should have warranty of at least 10 years. The work should be executed as per thedirections of Engineer–in-Charge.GROUND FLOOR | 134.39 | Sqm | 7,500 ₹10,07,925 Lowest | 7,800 ₹10,48,242 |
| 3.00 | Supply, installation, testing and commissioning of modular OT ceiling panels with insulated prefabricated puff Panels. The OT ceiling shall be constructed using GI puff panels having 0.8 mm thick GI sheets on both sides. These panels should have been produced in a double band laminator, in which two continuously moving belts carrying 120 GSM galvanized steel sheets of 0.80 mm thickness are firmly bonded together by sprayed -in insulating foam, which hardens during the process. The core consists of rigid polyurethane foam, which has been injected under high pressure, with a minimum density of 40kg/m3.
The thickness of Puff shall be minimum 40 mm. The sheet panel shall be ofindigenous reputed make and be provided with manufactures test certificate. The puff panel shall be fixed to the floor with bottom track of 1.5 mm thick steel U channel section having min size of 50mm X 50mm. The bottom shall be fixed in the floor of the OT with 10mm thicknessand min. 60 mm long SS fasteners which shall be fully threaded and power drilled. The Panels of walls and ceiling shall be tied together by suitable SS coving. The individual panels of wall and ceiling shall be tied together by suitable SS coving.
The individual wall panels shall be welded together bySS. All joints shall be filled with metal filler and shall be sand casted on site till smooth finish is obtained. Wall & panel joints shall not be visible after the final wall coating is applied. The gap between the masonry wall surfaces and the panel of the theatre shall be sufficient for the flush mounting of equipment’s. This gap shall be provided to accommodate the equipment at a latter date and to enable services, pipes conduits etc, to be run within the gap. All wall-mounted equipment shall be flush mounted and sealed in operation theatre
All the sharp edges and corners shall be in radius to avoid bacterial contamination. The wall panel design shall be such that it enables the installation and supports all equipment’s. Provision of openings required for the installations shall not affect rigidity and strength of the panel. Access boxes shall be fitted to the rear of all wall?mounted equipment to enable maintenance to be carried out from outside the operation theatre. Product should have warranty of at least 10 years. The work should be executed as per thedirections of Engineer–in-Charge.GROUND FLOOR | 44.15 | Sqm | 7,500 ₹3,31,125 Lowest | 7,500 ₹3,31,125 Lowest |
| 4.00 | Providing Epoxy flooring self leveling type on strong base in desired colour/design as approved by Engineer-in-Charge. Resin for epoxy is to be of floor grade type i/c appropriate hardner and filler material. with 5 year defect liability period 3 mm thick . Puff ceiling area | 44.15 | Sqm | 2,452 ₹1,08,255.8 Lowest | 2,452 ₹1,08,255.8 Lowest |
| 5.00 | Hermetically Sealed Sliding Door System: Fabrication, Supply, installation, testing & commissioning of sliding type Hermetically Sealed door having high density particle board cores/ CFC free Polyurethane, high pressure laminate face on both sides, viewing window 300 x 300mm. Size: 1500 x 2100 mm (W x H) as per direction of EIC. Automatic Doors: Provided with Radar Switch - 2 Nos., Foot Switch - 2 Nos. and Photocell Sensors. Automatic Door (1500 mm x 2100 mm)
Approved makes - Metaflex /REBBON / MDD Engineering/ Altos / Dormed/ Meditech | 1 | Nos | 2,55,000 ₹2,55,000 Lowest | 2,60,000 ₹2,60,000 |
| 6.00 | Revolving Chair With Arm Synchronic tilt mechanism (GODREJ INTERIO ACE FULL BACK CHAIR) (Product id: 5116877-70887346890) | 9 | Each | 15,800 ₹1,42,200 Lowest | 15,815 ₹1,42,335 |
| 7.00 | OCEAN LIFE SCIENCE CORPORATION Laboratory Steel Furniture Side bench with rack and table top OCEAN LIFE SCIENCE CORPORATIONR (OLSC-IWB) | 1 | Each | 3,06,858.05 ₹3,06,858.05 | 3,06,858 ₹3,06,858 Lowest |
| 8.00 | BETCO Laboratory Steel Furniture Island bench with table top BETCOR (BETCO-LB-202) | 2 | Each | 47,733.47 ₹95,466.94 | 47,733 ₹95,466 Lowest |
| 9.00 | Supplying, installation, testing & commissioning of Effluent Treatment Plant for the following duty:
Supply, installation, testing & commissioning of Screens .Mild Steel Suitable Sized Manually operated Bar Screen as per following specifications. Cleaning :- Manual Screen (1 Nos)
Supply, installation, testing & commissioning of Raw effluent lifting pumps complete with all accessories, motor of required capacity. Pumps shall have following duty:Make = Kirloskar/Wilo/Eqv. ( 1 Lot)
Supply, installation testing and commisioning of physico-chemical treatment, the system shall be comprising of dosing pump, dosing tank, and Agitators.(1 lot)
Providing and fixing all interconnecting plant piping of required MOC as MS/UPVC and isolation control valves for making the piping arrangement complete within the battery limits.(1 lot)
Supply, installation, testing & commissioning of SBR feed Pumps with CI casing & CI impeller complete with all accessories, motor of required capacity. The pumps shall be complete with all accessories. Pumps shall have following duty:(2 nos )
Supply, installation, testing & commissioning of SBR Based Biological system comprising of the following equipments:Air Blowers For SBR tanks(1 lot )
Make: PS aqua/ Grannus Water and Env. Solution Pvt. Ltd.(1 lot )
Pipes and fittings for Air piping and Air Grid. (1 lot )
Supplying, installing, testing, commissioning of Centrifugal Horizontal Filter Feed pumps Complete in CI body & CI impeller with motor, and all other accessories required to complete the system.Make - Kirloskar/Eqv(2 nos )
Supply, installation, testing & commissioning of Sludge transfer/feed pumps for sludge transfer to SHT complete with all the accessories, motor of required capacity. The pumps shall be complete with Base frame, Delivery header with pressure gauge on delivery line.Flow rate (each) = 0.5/1.0 m³/hr (1 lot )
Supplying, Installation, testing and commissioning of Chemical dosing system comprising of Sintex Tank with inlet/ outlet connection, piping and valves along with metering pump for dosing. (1 set )
Supplying, installing, testing, commissioning of Sludge Bag System of suitable size for the dewatering of sludge generated per day.(1 set )
Supplying, installation, testing & commissioning of FRP vessel filter with frontal piping and Valves with all the required accessories. Filter shall include media, standard fittings like pressure gauges, sampling cock, rinse drain.Dual Media Filter. (1 no )
Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of motor control centre fabricated out of 14 gauge CRCA sheet steel. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. 2 Nos. earthling terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. Panel should be complete with Isolation push button for every equipment and auto manual selection switches . Make: GWESPL/Eqv . ( 1 job ) | 1 | No | 4,50,000 ₹4,50,000 Lowest | 4,50,000 ₹4,50,000 Lowest |
| 10.00 | Tanks
Supply, installation. Testing and commissioning of following Tanks In MSEP/HDPE. (1 job ) | 1 | No | 2,50,000 ₹2,50,000 Lowest | 2,50,000 ₹2,50,000 Lowest |
Tender Value
₹85.2 L
EMD Value
₹1.7 L
Closing Date
25 Mar 2026, 5:00 pmClosed
EXECUTIVE OFFICER
NREP, GIRIDIH
Establishment of Integrated Public Health Lab (IPHL) Sadar Hospital Giridih Dist. Giridih
2026_NREPG_111774_1
NREP/GIRIDIH/30/2025-26 GR. 1
Open Tender
Civil Works
Percentage
240 days
NREP
Please refer tender documents
2 documents required · 2 mandatory
₹10,000
₹1.7 L
8 Aug 2026
18 Mar 2026
27 Mar 2026
18 Mar 2026
25 Mar 2026
18 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation, testing and commissioning of modular OT Wall and corner panels with insulated prefabricated puff Panels. The OT wall shall be constructed using GI puff panels having 0.8 mm thick GI sheets on both sides. These panels should have been produced in a double band laminator, in which two continuously moving belts carrying 120 GSM galvanized steel sheets of80 mm thickness are firmly bonded together by sprayed -in insulating foam, which hardens during the process. The core consists of rigid polyurethane foam, which has been injected under high pressure, with a minimum density of 40kg/m3. The thickness of Puff shall be minimum 40 mm. The sheet panel shall be of indigenous reputed make and be provided with manufactures test certificate. The puff panel shall be fixed to the floor with bottom track of 1.5 mm thick steel U channel section having min size of 50mm X 50mm. The bottom shall be fixed in the floor of the OT with 10mm thicknessand min. 60 mmlong SS fasteners which shall be fully threaded and power drilled The Panels of walls and ceilingshall be tied together by suitable SS coving. The individual wall panels of wall and ceiling shall be tied together by suitable SS coving. The individual wall panels shall be welded together bySS. All joints shall be filled with metal filler and shall be sand casted on site till smooth finish is obtained. Wall & panel joints shall not be visible after the final wall coating is applied. The gap between the masonry wall surfaces and the panel of the theatre shall be sufficient for the flush mounting of equipment’s. This gap shall be provided to accommodate the equipment at a latter date and to enable services, pipes conduits etc, to be run within the gap All wall-mounted equipment shall be flush mounted and sealed in operation theatre. All the sharp edges and corners shall be in radius to avoid bacterialcontamination. The wall panel design shall be such that it enables the installation and supports all equipment’s. Provision of openings required for the installations shall not affect rigidity and strength of the panel. Access boxes shall be fitted to the rear of all wall-mounted equipment to enable maintenance to be carried out from outside the operation theatre. Product should have warranty of at least 10 years. Thework should be executed as per the directions of Engineer–in-Charge. | 11.52 | Sqm | - | - |
| 2 | Supply, installation, testing and commissioning of modular OT Wall and corner panels with insulated prefabricated puff Panels. The OT wall shall be constructed using GI puff panels having 0.8 mm thick GI sheets on both sides. These panels should have been produced in a double band laminator, in which two continuously moving belts carrying 120 GSM galvanized steel sheets of The thickness of Puff shall be minimum 40 mm. The sheet panel shall be ofindigenous reputed make and be provided with manufactures test certificate. The puff panel shall be fixed to the floor with bottom track of 1.5 mm thick steel U channel section having min size of 50mm X 50mm. The bottom shall be fixed in the floor of the OT with 10mm thicknessand min. 60 mm long SS fasteners which shall be fully threaded and power drilled. The Panels of walls and ceiling shall be tied together by suitable SS coving. The individual panels of wall and ceiling shall be tied together by suitable SS coving.
The individual wall panels shall be welded together bySS. All joints shall be filled with metal filler and shall be sand casted on site till smooth finish is obtained. Wall & panel joints shall not be visible after the final wall coating is applied. The gap between the masonry wall surfaces and the panel of the theatre shall be sufficient for the flush mounting of equipment’s. This gap shall be provided to accommodate the equipment at a latter date and to enable services, pipes conduits etc, to be run within the gap. All wall-mounted equipment shall be flush mounted and sealed in operation theatre
All the sharp edges and corners shall be in radius to avoid bacterial contamination. The wall panel design shall be such that it enables the installation and supports all equipment’s. Provision of openings required for the installations shall not affect rigidity and strength of the panel. Access boxes shall be fitted to the rear of all wallmounted equipment to enable maintenance to be carried out from outside the operation theatre. Product should have warranty of at least 10 years. The work should be executed as per thedirections of Engineer–in-Charge.GROUND FLOOR | 134.39 | Sqm | - | - |
| 3 | Supply, installation, testing and commissioning of modular OT ceiling panels with insulated prefabricated puff Panels. The OT ceiling shall be constructed using GI puff panels having 0.8 mm thick GI sheets on both sides. These panels should have been produced in a double band laminator, in which two continuously moving belts carrying 120 GSM galvanized steel sheets of 0.80 mm thickness are firmly bonded together by sprayed -in insulating foam, which hardens during the process. The core consists of rigid polyurethane foam, which has been injected under high pressure, with a minimum density of 40kg/m3.
The thickness of Puff shall be minimum 40 mm. The sheet panel shall be ofindigenous reputed make and be provided with manufactures test certificate. The puff panel shall be fixed to the floor with bottom track of 1.5 mm thick steel U channel section having min size of 50mm X 50mm. The bottom shall be fixed in the floor of the OT with 10mm thicknessand min. 60 mm long SS fasteners which shall be fully threaded and power drilled. The Panels of walls and ceiling shall be tied together by suitable SS coving. The individual panels of wall and ceiling shall be tied together by suitable SS coving.
The individual wall panels shall be welded together bySS. All joints shall be filled with metal filler and shall be sand casted on site till smooth finish is obtained. Wall & panel joints shall not be visible after the final wall coating is applied. The gap between the masonry wall surfaces and the panel of the theatre shall be sufficient for the flush mounting of equipment’s. This gap shall be provided to accommodate the equipment at a latter date and to enable services, pipes conduits etc, to be run within the gap. All wall-mounted equipment shall be flush mounted and sealed in operation theatre
All the sharp edges and corners shall be in radius to avoid bacterial contamination. The wall panel design shall be such that it enables the installation and supports all equipment’s. Provision of openings required for the installations shall not affect rigidity and strength of the panel. Access boxes shall be fitted to the rear of all wallmounted equipment to enable maintenance to be carried out from outside the operation theatre. Product should have warranty of at least 10 years. The work should be executed as per thedirections of Engineer–in-Charge.GROUND FLOOR | 44.15 | Sqm | - | - |
| 4 | Providing Epoxy flooring self leveling type on strong base in desired colour/design as approved by Engineer-in-Charge. Resin for epoxy is to be of floor grade type i/c appropriate hardner and filler material. with 5 year defect liability period 3 mm thick . Puff ceiling area | 44.15 | Sqm | - | - |
| 5 | Hermetically Sealed Sliding Door System: Fabrication, Supply, installation, testing & commissioning of sliding type Hermetically Sealed door having high density particle board cores/ CFC free Polyurethane, high pressure laminate face on both sides, viewing window 300 x 300mm. Size: 1500 x 2100 mm (W x H) as per direction of EIC. Automatic Doors: Provided with Radar Switch - 2 Nos., Foot Switch - 2 Nos. and Photocell Sensors. Automatic Door (1500 mm x 2100 mm)
Approved makes - Metaflex /REBBON / MDD Engineering/ Altos / Dormed/ Meditech | 1 | Nos | - | - |
| 6 | Revolving Chair With Arm Synchronic tilt mechanism (GODREJ INTERIO ACE FULL BACK CHAIR) (Product id: 5116877-70887346890) | 9 | Each | - | - |
| 7 | OCEAN LIFE SCIENCE CORPORATION Laboratory Steel Furniture Side bench with rack and table top OCEAN LIFE SCIENCE CORPORATIONR (OLSC-IWB) | 1 | Each | - | - |
| 8 | BETCO Laboratory Steel Furniture Island bench with table top BETCOR (BETCO-LB-202) | 2 | Each | - | - |
| 9 | Supplying, installation, testing & commissioning of Effluent Treatment Plant for the following duty:
Supply, installation, testing & commissioning of Screens .Mild Steel Suitable Sized Manually operated Bar Screen as per following specifications. Cleaning :- Manual Screen (1 Nos)
Supply, installation, testing & commissioning of Raw effluent lifting pumps complete with all accessories, motor of required capacity. Pumps shall have following duty:Make = Kirloskar/Wilo/Eqv. ( 1 Lot)
Supply, installation testing and commisioning of physico-chemical treatment, the system shall be comprising of dosing pump, dosing tank, and Agitators.(1 lot)
Providing and fixing all interconnecting plant piping of required MOC as MS/UPVC and isolation control valves for making the piping arrangement complete within the battery limits.(1 lot)
Supply, installation, testing & commissioning of SBR feed Pumps with CI casing & CI impeller complete with all accessories, motor of required capacity. The pumps shall be complete with all accessories. Pumps shall have following duty:(2 nos )
Supply, installation, testing & commissioning of SBR Based Biological system comprising of the following equipments:Air Blowers For SBR tanks(1 lot )
Make: PS aqua/ Grannus Water and Env. Solution Pvt. Ltd.(1 lot )
Pipes and fittings for Air piping and Air Grid. (1 lot )
Supplying, installing, testing, commissioning of Centrifugal Horizontal Filter Feed pumps Complete in CI body & CI impeller with motor, and all other accessories required to complete the system.Make - Kirloskar/Eqv(2 nos )
Supply, installation, testing & commissioning of Sludge transfer/feed pumps for sludge transfer to SHT complete with all the accessories, motor of required capacity. The pumps shall be complete with Base frame, Delivery header with pressure gauge on delivery line.Flow rate (each) = 0.5/1.0 m³/hr (1 lot )
Supplying, Installation, testing and commissioning of Chemical dosing system comprising of Sintex Tank with inlet/ outlet connection, piping and valves along with metering pump for dosing. (1 set )
Supplying, installing, testing, commissioning of Sludge Bag System of suitable size for the dewatering of sludge generated per day.(1 set )
Supplying, installation, testing & commissioning of FRP vessel filter with frontal piping and Valves with all the required accessories. Filter shall include media, standard fittings like pressure gauges, sampling cock, rinse drain.Dual Media Filter. (1 no )
Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of motor control centre fabricated out of 14 gauge CRCA sheet steel. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. 2 Nos. earthling terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. Panel should be complete with Isolation push button for every equipment and auto manual selection switches . Make: GWESPL/Eqv . ( 1 job ) | 1 | No | - | - |
| 10 | Tanks
Supply, installation. Testing and commissioning of following Tanks In MSEP/HDPE. (1 job ) | 1 | No | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
SBD.pdf
Tender Documents • 1.36 MB
BOQ_150918.xls
BOQ • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .