MR SE BRIDGE RAIPUR PRAKHAR KUMAR MISHRA(DFLT)
CE(Bridge)
Painting Works of Various Bridge under PWD Bridge Sub Division Mahasamund for Year 2026-27
200308
NIT NO-25/Bridge/Raipur/2026-27
RESTRICTED TENDER
WORKS
PERCENTAGE
CE(Bridge)
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
9 documents required · 9 mandatory
Public Works Department (PWD)
WORKS
MR SE BRIDGE RAIPUR PRAKHAR KUMAR MISHRA(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B C D
CE(Bridge)
Bridge Circle, Raipur
Bridge Division Raipur
120
No
1
33.25
20092022
200308
15 Oct, 2026 5:30:00 PM IST
22 Oct, 2026 11:30:00 AM IST
26 Sep, 2026 10:30:00 PM IST
24092026
NIT NO-25/Bridge/Raipur/2026-27
Painting Works of Various Bridge under PWD Bridge Sub Division Mahasamund for Year 2026-27
15900.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
2
21 Oct, 2026 5:30:00 PM IST
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
31032027
18d 22h 42m
0010720220002
9 documents required · 9 mandatory
₹0
₹15,900
26 Sept 2026
26 Sept 2026
22 Oct 2026
26 Sept 2026
21 Oct 2026
NAME OF WORK : CONSTRUCTION OF HIGH LEVEL BRIDGE ACROSS
PAIRY RIVER ON NAHARGAON-NAGABUDA-BARULA ROAD IN K.M. 5/6-8
S.No. Particular of Item Quantity Unit Rate Amount
2.1/P-12 Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)
A Ordinary soil
(i) Upto 3 m depth
For piers P2 to P10 ( from Av. G.L. R.L.
For Abutment A1 & A2
(From Av. G.L. R.L. 98.560 M. To R.L. 97.000 M.)
Rectangular Portion 2 6 8.4 1.56
Half Circular portion 2 1/2 x 3.142 x (4.75)2 1.56
For Return R1 & R2
i Upto 3m Depth 2 4.5 8.4 3 cum 118
(From Av. G.L. R.L. 98.560 M. To R.L. 95.560 M.)
ii Upto 3m To 6m Depth
2.4/P-12 PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
For Return 2 4.5 8.4 0.15 cum 2817
2.7/P-13 Plain / Reinforced cement concrete in open foundation complete as per drawing and technical specifications :
A Using concrete mixer
i) PCC Grade M15
Levelling course for Returns 2 4.5 8.4 0.15
(iv) RCC Grade M30
for Footing of Return Wall 2x2 0.65 4.5 0.3
for Main Wall(From R.L.94.300M. To R.L. 98.000M.) 2x2 4.5 0.3 3.7
for Tie Wall(From R.L.94.300M. To R.L. 98.000M.) 2x2 7.8 0.3 3.7
for Main Wall(From R.L.98.000M. To R.L. 98.560M.) 2x2 4.5 0.3 0.56
for Counterfort Wall(From R.L.98.000M. To R.L. 98.560M.) 2x2 (2.700+2.464)/2 0.3 0.56
2.9/P-13 Providing and laying cutting edge of mild steel weighing 40 kg per meter for well foundation complete as per drawing and technical specifications per relevant clause of section 1200 and 1900.
Providing @ 40 kg per m
for P1 To P10 10 π x 6.65 0.04
for A1 To A2 2 π x 9.65 0.04
2.10/P-13 Plain/Reinforced cement concrete, in well foundation complete as per drawing and technical specification as per clauses of section 1200,1500 and 1700.
(a) Using Concrete Mixer
(ii) RCC Grade M-25
B Well steining
(a) Using Concrete Mixer
(iii) PCC Grade M-25
Abutment A1 & A2 2 x π x [4.752 - 3.7502] 8
(a) Using Concrete Mixer
(ii) PCC Grade M-25
Abutment A1 & A2 2 π x 3.752 0.6
(a) Using Concrete Mixer
(i) PCC Grade M-15
Abutment A1 & A2 2 π x 3.752 0.5
(a) Using Concrete Mixer
(iii) RCC Grade M-30
Abutment A1 & A2 2 1/2 x π x 4.752 1
2.11/P-15 Sinking of well to be measured below L.W.L. through all types of soil & rock (Other than pneumatic method of sinking) complete as per drawing and specifications as per section 1200 in (the rates include the removal of all type of obstruction)
(i) Upto 3 M. Depth.
For Abutment A1
(ii) 3 M. to 10 M. Depth.
For Abutment A1
(a) From 10 M to 20 M add 10% for every additional meter depth of sinking
From R.L.83.600m To R.L.82.600m 1 π 3.25 2 1 cum
From R.L.82.600m To R.L.81.600m 1 π 3.25 2 1 cum
From R.L.81.600m To R.L.80.600m 1 π 3.25 2 1 cum
From R.L.80.600m To R.L.79.600m 1 π 3.25 2 1 cum
From R.L.79.600m To R.L78.600m 1 π 3.25 2 1 cum
From R.L.78.600m To R.L78.200m 1 π 3.25 2 0.4 cum
From R.L.83.600m To R.L.82.600m 1 π 3.25 2 1 cum
From R.L.82.600m To R.L.81.600m 1 π 3.25 2 1 cum
From R.L.81.600m To R.L.81.000m 1 π 3.25 2 0.6 cum
(i) Upto 3 M. Depth.
For Pier P8-P10
For Abutment A2
(ii) 3 M. to 10 M. Depth.
For Abutment A2
(a) From 10 M to 20 M add 10% for every additional meter depth of sinking
From R.L.83.600m To R.L.82.600m 3 π 3.25 2 1 cum
From R.L.90.490m To R.L.89.490m 3 π 3.25 2 1 cum
From R.L.88.490m To R.L.87.490m 3 π 3.25 2 1 cum
From R.L.87.490m To R.L.86.490m 3 π 3.25 2 1 cum
From R.L85.490m To R.L.84.490m 3 π 3.25 2 1 cum 594
From R.L84.490m To R.L.83.490m 3 π 3.25 2 1 cum 633.6
From R.L83.490m To R.L.82.490m 3 π 3.25 2 1 cum 673.2
From R.L82.490m To R.L.81.490m 3 π 3.25 2 1 cum 712.8
From R.L81.490m To R.L.80.490m 3 π 3.25 2 1 cum 752.4
(b) Beyond 20 M depth add 15% for every additional meter depth of sinking
2.12/P-16 Sand Filling in wells complete as per Drawing and Technical Specifications as per section 1207.
Pier P3 1 π X 2.402 8.3
Pier P4 1 π X 2.402 6.3
For Abutment A1&A2 2 π X 3.752 7.2
2.23/P-17 Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications as per section 1600.
Well Curb @ 80 Kg / Cum 0.08
Well steining @ 20 Kg / Cum 2155.055 0.02
Well cap @ 80 Kg / Cum for pier 0.08
Well cap @ 120 Kg / Cum for Abutment 0.12
Return @ 80 Kg / Cum 0.08
2.25/P-17 Taking exploratory boring 100 mm dia at the location of piers and abutments or for high embankments in approaches in all types of strata as per I.R.C. 78-1983 and section 2400 of specifications.
(i) Upto 1.0m below bed level 12 1 Each 5750
(ii) Beyond 1.0m upto 5.0m depth 12 4 Meter 1150
(iii) Beyond 5.0m depth
Pier P1 1 17.05
Pier P2 1 14.55
Pier P3 1 12.05
Pier P4 1 10.05
for Abutment A1&A2 2 10.06
2.26/P-17 Providing and laying 1.5 m deep in rock and 1.5 m above rock 25 mm dia fot Steel dowel bars in foundation including drilling 65mm dia bore hole in rock necessary bending, hooking tying, reinforcement in position and grouting etc. complete as per drawings and specifications.
Pier P1 - P10 10 6
for Abutment A1&A2 2 6
3.6/P-19 Providing and laying Plain / Reinforced cement concrete in sub-structure complete as per drawing and technical specifications as per section 1500, 1700 and 2200
D Height upto 5m
(a) Using Concrete Mixer
(iii) R.C.C. Grade M-30
Side wall (From RL 98.000m to R.L. 100.800m) 2 x 2 5.4 0.2 2.8
Intermediate wall and rear wall ( From R.L.98.000m to R.L.104.050m) 2 x 2 8.4 0.2 6.05
Inner Wall (From RL 98.000m to R.L. 100.800m) 2 x 2 5.4 0.2 2.8
Front Wall (From RL 98.000m to R.L. 100.800m) 1 X 2 8.4 0.2 2.8
Abutment Cap(From RL100.800m to R.L. 101.300m) 1 X 2 8.4 1.3 0.5
Dirt Wall (From RL101.300m to R.L. 104.050m 1 X 2 8.4 0.3 2.75
Side wall (From RL 100.800m to R.L. 104.050m) 2 x 2 4.8 0.2 3.25
Inner wall (From RL 100.800m to R.L. 104.050m) 2 x 2 4.8 0.2 3.25
Return Wall (From RL 98.560m to R.L. 104.050m)
Main Wall 2 x 2 4.5 0.3 5.49
Counterfort Walls 4 x 2 (0.150+2.464)/2 0.3 5.49
Piers P1-P10 (from RL 94.600m to R.L. 99.450m) 10 π 1.00 2 4.85
Square head 10 2 2 0.4
D Height upto 5m
(a) Using Concrete Mixer
(iv) R.C.C. Grade M-35
Pedestal for Abutment 3 x 2 0.95 0.7 0.422 cum 4276
E Height 5m to 10m
(a) Using Concrete Mixer
(iv) R.C.C. Grade M-35
Pedestal Pier P1 to P10 10 x 6 0.95 0.7 0.422 cum 4369
3.7/P-20 Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications section 1600 and 2200
Providing @ 80 kg / cu m 0.08
3.9/P-20 Providing weep holes in Brick masonry/ Plain/ Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications section 2706 and 2200
For Abutment 30
3.10/P-21 Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification 710, 1.4 of I.R.C. 78 and 2200
(i) Granular material
For Return From ( R.L. 98.560m to R.L.103.970m) 1 x 2 4.5 7.8 5.41
Deduct quantity as per sor item no. 3.11
3.11/P-21 Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specifications 710.1.4 of I.R.C. 78 and 2200
Front Wall (From R.L.98.560m to 100.800m) 2 x 2 2.533 0.6 2.24
Side Wall (From R.L.98.560m to 100.800m) 2 x 2 2.7 0.6 2.24
Side Wall (From R.L.100.800m to 103.970m) 2 x 2 2.7 0.6 3.17
Side Wall (From R.L.98.560m to 103.970m) 4 x 2 0.8 0.6 5.41
3.15/P-21 Suppling, fitting and fixing in position true to line and level elastomeric bearing confirming to IRC : 83 Part II section IX and clause 2005 of MORTH specifications complete i/c all accessories as per drawing and technical specifications and section 2000 and 2200.
For Piers P1 - P10 10 x 6 63 36 7.8
For Abutment A1& A2 3 x 2 63 36 7.8
per cubic centimeter 1
SUPER-STRUCTURE
4.1/P-24 Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification sections 1500, 1600 and 1700
D RCC/PSC Grade M35
I For Solid Slab Super Structure
(a) Using Concrete Mixer
(ii) Height 5m to 10m
Soffit Slab 2 2.25 5.05 0.2
End Diaphragm 2 5.05 0.5 2.05
Meet Diaphragm 3 3.7 0.3 2.05
Kerb for Abutment & Return 2 x 2 10 (0.45+0.425)/2 0.3
Deduct Opening (-) 4 1.2 0.5 0.6
For Eleven Nos. Of Span 11 Cum 5767
4.2 Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications
HYSD Bar @ 120Kg/Cum For span 0.12
HYSD Bar @ 40Kg/Cum For Kerb 0.04
4.3 High tensile steel wires/strands including all accessories for stressing, stressing operations and grouting complete as per drawing and Technical Specifications
H.T. Steel @5.0T/ Span 11 5 MT 124316
4.4 Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications 11 34.96 7.5 0.075 Cum 7569
4.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications. (vide drawing No. SD/201, SD/304) 2 404.56 Meter 1234
4.1 Drainage Spouts complete as per drawing and Technical specifications of section 2705 11 12 Each 1188
4.11 PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification and as per relevant section 2700
4.12 Providing and laying M-30 grade Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification and as per relevant sections 1500, 1600, 1700 and 2704
For Abutment 2 5.5 8.4 0.25
For return 2 4.5 8.4 0.25
4.17 Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorized representative ensuring compliance to the manufacturer's instructions for installation.) 12 8.4 Meter 11116
4.19 Painting on kerbs in black and yellow alternate bands including cost of material and labour complete as per drawings and specifications as per clause 803.
With road marking paint 2 404.56 R.M. 40
4.21 Providing and Fixing of Av. 20mm thick Granite plate including cutting and polishing and inscribed details as per approved drawing i/c engraving the matter as desired. 4 Each 4200
4.22 Testing of span of bridge for deflection due to live load with platform for loading arrangements, apparatus for measurement etc. complete as per drawing and specifications (As per I.R.C.S.P.51) 77 Tonne 672
4.26 Providing & filling 37/40 mm. wide expansion joint between spans in wearing coat with premoulded joint filler, primer coat and joint sealing compound as per MOST standard drawing No. BD/1-69 'B' and specifications as per section 2600 in:-
(i) R.C.C. 75 mm deep wearing coat 25 7.5 Meter 121
REPORT AND SPECIFICATION
1 Name of Work :- SPECIAL REPAIR WORK (EXPANSION JOINT & CONCRETE WORK ) BRIDGES OF SUB DIVISION, MAHASAMUND
2 P.A.C. :- 25.00 Lakh
3 Authority :- E IN C, P.W.D BRIDGE CHHATTIGARH
4 Work Details :- 1 Surangi Nalla on Basna-Padampur Road
2 Surangi Nalla on Saraipali-Padampur Road
3 Diwanpali Nalla on Singhoda-Birkol Road
4 Lat Nalla on Singhoda-Birkol Road
5 Necessity :- milaHkkx] egkleqan ds varxZr o"kZ 2026&27 fo'ks"k ejEer dk;Z fd;k tkuk gSA vko';drkuqlkj ejEer dk;Z dk foLr`r izkDdyu rS;kj fd;k x;k gSA
6 Specifcation :- MORT&H and IRC specification will be followed for the construction of the bridge.
7 Rates :- For bridge work SOR issued by Engineer-in-Chief C.G.P.W.D. Raipur w.e.f. 15.06.2026 & for road work SOR issued by Engineer-in-Chief C.G.P.W.D. Raipur w.e.f. 15.06.2026 & amended up to date has been adopted to frame the estimate.
N.I.T. SCHEDULE
N.I.T. SCHEDULE FOR SPECIAL REPAIR WORK (EXPANSION JOINT & CONCRETE WORK ) BRIDGES OF SUB DIVISION, MAHASAMUND
S. NO. S.O.R. ITEM NO. Particular of Item Quantity RATE Unit
EXPANSION JOINT
1 CH-1/1.5 /P-12 Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with including all leads and lifts and as per relevant clauses of section-200 in
(i) Lime/Cement Concrete
C Prestressed / Reinforced cement concrete grade M-20 & above
Surangi Nalla on Basna-Padampur road, Surangi Nalla on Saraipali-Padampur road, Diwanpali Nalla on Singhoda-Birkol road & Lat Nalla on Singhoda-Birkol road 16 1141 Cum
2 CH-6/6.14 /P-47 Removal of Expansion Joints complete as per approved drawings (Only Removal of old expansion joint)
Surangi Nalla on Basna-Padampur road, Surangi Nalla on Saraipali-Padampur road, Diwanpali Nalla on Singhoda-Birkol road & Lat Nalla on Singhoda-Birkol road 3061 RM
3 CH-4/4.22 /P-39 Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorized representative ensuring compliance to the manufacturer's instructions for installation.)
Surangi Nalla on Basna-Padampur road, Surangi Nalla on Saraipali-Padampur road, Diwanpali Nalla on Singhoda-Birkol road & Lat Nalla on Singhoda-Birkol road 9832 Meter
4 CH-4/4.1 /P-33 Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification sections 1500, 1600 and 1700
C RCC/PSC Grade M35
I For Solid Slab Super Structure
(a) Using batch type concrete mixer with integrated weigher
Surangi Nalla on Basna-Padampur road, Surangi Nalla on Saraipali-Padampur road, Diwanpali Nalla on Singhoda-Birkol road & Lat Nalla on Singhoda-Birkol road 16 5785 Cum
5 CH-6/ 6.1/P-46 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lift sand all leads as per section 2809
Surangi Nalla on Basna-Padampur road, Surangi Nalla on Saraipali-Padampur road, Diwanpali Nalla on Singhoda-Birkol road & Lat Nalla on Singhoda-Birkol road 863.25 107 Sqm
6 CH-4/ 4.4 /P-35 Providing and laying Cement concrete wearing coat M-35 grade including reinforcement of 8 mm diameter @ 150 mm c/c spacing in both ways foreach 75 mm thickness of concrete complete as per drawing and Technical Specifications as per section 2700
Surangi Nalla on Basna-Padampur road, Surangi Nalla on Saraipali-Padampur road, Diwanpali Nalla on Singhoda-Birkol road & Lat Nalla on Singhoda-Birkol road 64.74 10781 sqm
7 CH-4/ 4.13 /P-38 Drainage Spouts complete as per approved drawing and Technical specifications of section 2705
Surangi Nalla on Basna-Padampur road, Surangi Nalla on Saraipali-Padampur road, Diwanpali Nalla on Singhoda-Birkol road & Lat Nalla on Singhoda-Birkol road 24 2285 Each
Sub Engineer Sub Divisional Officer Executive Engineer
P.W.D. Bridge Construction P.W.D. Bridge Construction
Sub Division, Mahasamund (C.G.) Division, Raipur (C.G.)
GENERAL ABSTRACT
SPECIAL REPAIR WORK (EXPANSION JOINT & CONCRETE WORK ) BRIDGES OF SUB DIVISION, MAHASAMUND
PROJECT CIRCLE :- BRIDGE CIRCLE RAIPUR
PROJECT DIVISION :- BRIDGE DIVISION RAIPUR
Sr.No. Sub Head Amount Remarks
1 Special Repair work for Expansion Joint Rs. 1271186
2 Special Repair work for Concrete work Rs. 847457
Add 18 % GST Rs.
Grand Total Rs.
Say Amount Rs. Lacs
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.12 MB
947891851723121709_25412_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
2626932606606988277_200308_e-procurement formet.doc
NIT • 0.07 MB
8034278305143440436_200308_FORM A.doc
NIT • 0.18 MB
77657091416206575_200308_NIT 2.doc
NIT • 0.28 MB
3167832546768336018_200308_NIT REPORT SPECI.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .