Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.1 LAdmitted-Finance | ₹40.1 L | L1 | Admitted-Finance |
| 2 | L2₹44.9 LAdmitted-Finance | ₹44.9 L | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | GPK ELECTRICALS L2 | T.HABIBULLAH CONTRACTOR L1 |
|---|---|---|---|---|---|
| 1.00 | Preventive Maintenance/ Corrective maintenance in 9u/32u/42u Network racks and Network Patch panels including inspection, trouble shooting, repair, crimping of keystone jacks, replacement of core components such as PDB, power supplies, cooling fans, door glass, trays, cable manager & all other accessories, cleaning, painting and restoration to full operational status of all racks. | 45 | No of Operations | 1,350 ₹60,750 | 3,800 ₹1.7 L |
| 2.00 | Upkeep of Intranet Web Servers, ACS Servers, CTAMS System & Server and KMS/TLD Units & Server including backup/restore, update the firmware/software, configuring the server if required. | 50 | No of Operations | 1,350 ₹67,500 | 3,800 ₹1.9 L |
| 3.00 | Preventive & Breakdown Maintenance of C & I systems for various Test Loops in R & D Facility which includes routine Calibration & Testing of various field instruments like Temperature, Pressure, Level, Flow and Temperature gauges, Switches & transmitters., development of various DAQ system/programs to acquire the test loop parameters in computer servers for detailed analysis. | 75 | No of Operations | 1,350 ₹1.0 L | 4,000 ₹3 L |
| 4.00 | Upkeep, cleaning of biometric readers, XBIS, DFMD, CCTV and other ACS systems. Carrying out periodic maintenance of Security system including RFID controllers, Android box and TVs. Servicing, testing, replacement of faulty HDMI, ethernet and RS232 cables in scanners. | 40 | No of Operations | 1,350 ₹54,000 | 3,000 ₹1.2 L |
| 5.00 | Lay/Install and terminate indoor Ethernet and OFC cables (including CAT6 or 12/24/48 fiber) with appropriate casing/capping, GI conduit, or surface mounting as required. Only cables are FIM. | 1,000 | RM | 375 ₹3.8 L | 113.25 ₹1.1 L |
| 6.00 | Earthwork excavation in sandy soil and other types of soil up to 1.50m or as required , Removing of surplus earth with a lead up to 50 metres and as per drawings, specifications and as directed by the Engineer-in-Charge. | 300 | Cu.m | 400 ₹1.2 L | 1,200 ₹3.6 L |
| 7.00 | Laying of ethernet or Optical Fiber cable with HDPE pipe & 18-20 Nos. bricks per Mtr. in the excavated trenches, filling the space between the bricks & cable and trench with soil, backfilling, levelling up and compacting of earth by ramming/watering or other means & restoring surface. Only cables are FIM. | 300 | RM | 650 ₹1.9 L | 375 ₹1.1 L |
| 8.00 | Testing of OFC using OTDR, identifying the fault location, splicing of OFC, repair, replacement of Media converters, SFP modules & other related hardware. | 25 | No of Operations | 1,300 ₹32,500 | 3,000 ₹75,000 |
| 9.00 | Arranging Video Conferencing and assisting in operation of AV devices in conducting Seminar/webinar in Meeting halls/Classroom including testing/repair/replacement of AV equipment, Amplifiers, Speakers, power supplies, projectors, TV units, cameras and other hardwares on day to day basis/requirement. | 120 | No of Operations | 1,300 ₹1.6 L | 2,300 ₹2.8 L |
| 10.00 | Scan/digitize the existing documents/drawings in required formats at Drawing Office, organizing/editing photos and videos and securely archiving the Photo and video recordings, Assisting in Maintenance of Record room and digitization of all documents/drawings & cataloguing/classification and secure storage in the designated Data Backup Servers. | 130 | No of Operations | 1,200 ₹1.6 L | 2,850 ₹3.7 L |
Tender Value
₹45.6 L
EMD Value
₹91,296
Closing Date
19 Jan 2026, 3:30 pmClosed
As per tender document
As per tender document
OPERATION and MAINTENANCE OF NETWORKS VC SECURITY and PHYSICAL PROTECTION SYSTEMS DOCUMENT DIGITIZATION AND R AND D WORKS AT PRP
2025_BARC_891292_1
PRPD/TS/965/MW/K-3131/2025
Open Tender
Miscellaneous Works
365 days
kalpakkam
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹91,296
6 Feb 2026
26 Dec 2025
21 Jan 2026
26 Dec 2025
19 Jan 2026
31 Dec 2025
29 Dec 2025 - 7 Jan 2026
Preventive Maintenance/ Corrective maintenance in 9u/32u/42u Network racks and Network Patch panels including inspection, trouble shooting, repair, crimping of keystone jacks, replacement of core components such as PDB, power supplies, cooling fans, door glass, trays, cable manager & all other accessories, cleaning, painting and restoration to full operational status of all racks.
Upkeep of Intranet Web Servers, ACS Servers, CTAMS System & Server and KMS/TLD Units & Server including backup/restore, update the firmware/software, configuring the server if required.
Preventive & Breakdown Maintenance of C & I systems for various Test Loops in R & D Facility which includes routine Calibration & Testing of various field instruments like Temperature, Pressure, Level, Flow and Temperature gauges, Switches & transmitters., development of various DAQ system/programs to acquire the test loop parameters in computer servers for detailed analysis.
Upkeep, cleaning of biometric readers, XBIS, DFMD, CCTV and other ACS systems. Carrying out periodic maintenance of Security system including RFID controllers, Android box and TVs. Servicing, testing, replacement of faulty HDMI, ethernet and RS232 cables in scanners.
Lay/Install and terminate indoor Ethernet and OFC cables (including CAT6 or 12/24/48 fiber) with appropriate casing/capping, GI conduit, or surface mounting as required. Only cables are FIM.
Earthwork excavation in sandy soil and other types of soil up to 1.50m or as required , Removing of surplus earth with a lead up to 50 metres and as per drawings, specifications and as directed by the Engineer-in-Charge.
Laying of ethernet or Optical Fiber cable with HDPE pipe & 18-20 Nos. bricks per Mtr. in the excavated trenches, filling the space between the bricks & cable and trench with soil, backfilling, levelling up and compacting of earth by ramming/watering or other means & restoring surface. Only cables are FIM.
Testing of OFC using OTDR, identifying the fault location, splicing of OFC, repair, replacement of Media converters, SFP modules & other related hardware.
Arranging Video Conferencing and assisting in operation of AV devices in conducting Seminar/webinar in Meeting halls/Classroom including testing/repair/replacement of AV equipment, Amplifiers, Speakers, power supplies, projectors, TV units, cameras and other hardwares on day to day basis/requirement.
Scan/digitize the existing documents/drawings in required formats at Drawing Office, organizing/editing photos and videos and securely archiving the Photo and video recordings, Assisting in Maintenance of Record room and digitization of all documents/drawings & cataloguing/classification and secure storage in the designated Data Backup Servers.
Printing, assorting, arranging, binding and labelling the documents, journals, SOPs, manuals, training materials and other documents as instructed. Organising and maintaining the data bases and ensuring the synchronization of periodical data backup. Organising records and cataloguing them as per the instructions for Record Keep. Data entry of records scanned and archived & managing record retention schedules.
Preparation of test setups involving, wiring of control panel/rack, preparation of connectors by soldering/crimping, cabling, installation of indicators, switches or instruments, configuration of hardware/software.
Design, Development and reverse engineering works: Tracing of printed circuits, wiring/cabling, drawing using CAD software and circuit analysis at Indigenization Lab. Installation/assembly of electronic components/cards, Soldering/De-soldering of electronic circuits, Data acquisition, Testing & Tuning of newly developed electronic boards/modules, simulation of signals.
Fabrication, Soldering, testing and installation of Routed 6 layer pcb as per the EIC design in rigid PCB with minimum 1.6mm thickness. Immersion GOLD Finish having temperature gradient of 140 deg.C.
Fabrication, Soldering, testing and installation of Routed 2 layer Rigid/Flex pcb as per the EIC design in FR4 Rigid PCB with minimum 2mm thickness, HAL (Sn-Pb) Finish having temperature gradient of 140 deg.C.
Fabrication and supply of Copper Cladded Laminate as per the requirement Material: FR4 (Std.Tg) , Size: 229mmX305mm (9"X12"), two holes of d=2mm (Predrilled)
Filament for 3D printer: 3D printer Filament 1.75mm dia, Material : PLA, ABS ,PETG
TPU filament for 3D Printer :3D , 1.75mm dia, Material : TPU
FIBER LC-LC SINGLEMODE DUPLEX 2MTRS : LC connectors with12mm/18mm with 25mm short boots , High quality zirconia ferrules, Duplex: 1.6/2.0/3.0mm, Simplex: 0.9/2.0/3.0mm
FIBER LC-SC SINGLEMODE DUPLEX 2MTRS : LC connectors with 12mm/18mm and SC connectors with 25mm short boots , High quality zirconia ferrules, Duplex: 1.6/2.0/3.0mm, Simplex: 0.9/2.0/3.0mm
10G SFP modules :Single Mode, 1310 nm, Duplex LC Connector, 9 micron , 20 Km Tx/Rx
LIU fully loaded 24 core fiber :Shall be Capable of storing up to 3 meters of 900um tight buffered fiber per adapter Type 19’” Easy Front Access (EFA) Sliding Rack Mount LC Duplex type Material: Cold rolled carbon sheet steel with electrostatic spraying, Fibre Bending Radius ≥40 mm , Cable clamps on the inner surface for fixing cables. Splice tray shall be Fixed type Splice tray to access pigtails available. Lockable front door on front with push button. Easy Front Access Sliding patch panel for easy rework and maintenance.
Industrial Grade Rack mount 24 port Ethernet Patch panel: 24 port patch panel installed with Zinc Alloy RJ45 Modular Jack Polycarbonate 94V IDC connecting block, Contacts shall be Beryllium copper, plated with 1.27μm [50μin] thick gold in localized area and 3.8μin minimum thick tin-lead in solder area, Cutting Blade and Shield Point Contact of SS, Panel shall be Steel, black powder coat and shall support solid, 24-22 AWG conductors and Accepts cables with a maximum O.D. of 9 mm
Wall mount tool less 2 way IO RJ 45 Keystone jack WITH FACE PLATE: Tool less Cat6 RJ45 Rapid Connection Socket, connects to Cat5, Cat5e, or Cat6 cables terminated with RJ-45 plugs Rear retention caps ensure secure wire termination Insertion and extraction life is 750 Cycles Minimum and Meets Category 6 TIA/EIA-568-B.2 with Jack housing is high-impact, flame resistant plastic, UL 94V-0. Spring wire is phosphor bronze alloy plated with 50 micro-inch of gold over 100 micro-inches of nickel.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.66 MB
TDocK3131.pdf
Tender Documents • 2.34 MB
CPWDGCC2014.pdf
Additional Documents • 1.48 MB
BOQ_936829.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid