| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.6 LAccepted-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹15.8 L+₹11,790 (0.75%)Rejected-Finance 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹16.1 L+₹38,685 (2.47%)Rejected-Finance 97 19 JWALA HERI PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹16.6 L+₹88,970 (5.68%)Rejected-Finance RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹16.7 L+₹99,999 (6.38%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹35,840
Closing Date
3 Jul 2021, 6:00 pmClosed
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
SPECIAL REPAIR TO REPLACEMENT OF BER WINDOW/ SPLIT TYPE AIR CONDITIONER AT DIPAC AREA AND NOM VARUNA UNDER GE(U) PM DELHI CANTT-10
2021_MES_448578_1
GE(U)/PM/D-05/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
DELHI CANTT
MES contractor enlisted under class E category c(i) having deposited standing security of Rs 50000 with department. Contractor not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹35,840
Yes
12 Jul 2021
4 Jun 2021
5 Jul 2021
4 Jun 2021
3 Jul 2021
19 Jun 2021
Amount
Supply, Installation, commissioning and testing of Inverter Technology Hot & Cold Split Type wall mounted Air Conditioner (indoor & outdoor unit with cordless remote control unit) of Capacity not less than 1.5 TR, BEE 5 star rating , fitted with rotary compressor (5 years Warranty), Refrigerant type R-410A/R-32, rated cooling capacity not less than 5100 Watts/ 17400 BTU/ hr and rated heating capacity not less than 5300 Watts/ 18100 BTU/ hr, PVC FRLS grade multi stranded copper conductor cable 4 core 2.5 Sqmm for connections with outdoor unit, clamps, nuts, bolts, washers, drilling holes on walls/ceiling for connection/drain pipes and making good the disturbed surfaces of wall/ ceiling with cement mortar, white cement and painting work to match the existing surfaces of walls complete all as specified and directed. (Make:- Latest Model of Daikin/ Latest Model of O-General/ Latest Model of Hitachi or equivalent latest model and make of Blue Star.)
Supply, Installation, commissioning and testing of Inverter Technology Hot & Cold Split Type wall mounted Air Conditioner (indoor & outdoor unit with cordless remote control unit) of Capacity not less than 2.0 TR, minimum BEE 4 star rating , fitted with rotary compressor (5 year Warranty), Refrigerant type R-410A/R-32, rated cooling capacity not less than 6450 Watts/ 22000 BTU/ hr and rated heating capacity not less than 7033 Watts/ 24000 BTU/ hr, PVC FRLS grade multi stranded copper conductor cable 4 core 2.5 Sqmm for connections with outdoor unit, clamps, nuts, bolts, washers, drilling holes on walls/ceiling for connection/drain pipes and making good the disturbed surfaces of wall/ ceiling with cement mortar, white cement and painting work to match the existing surfaces of walls complete all as specified and directed. (Make:- Latest Model of Daikin/ Latest Model of O-General/ Latest Model of Hitachi or equivalent latest model and make of Blue Star.) Note for item No. 1 & 2:- (i) PVC drain pipe of suitable size & Heavy Duty copper connection pipes including suitable insulation upto 3 mtrs are deemed to be included in above quoted rate. (ii) PVC drain pipe of suitable size & Heavy duty copper connection pipes including suitable insulation Exceeding 3 mtrs shall be measured and paid seperately under relevant item.
Supply and fixing Single pole and neutral steel metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amps including taking down old one complete all as specified and directed by Engr-in-Charge. (Make : LEGRAND/ L&T / ABB/SEIMENS.)
Taking down unserviceable sub main wiring of any type and any size including wooden batten, PVC conduit or casing caping complete all as specified and as directed.
Material and labour for AC sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded, unsheathed 1100 volts grade in PVC casing caping (medium grade) of adequit size with all fittings and accessories surface type including one run 4 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694) as earth wire complete all as specified and as directed.
Material and labour for AC sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded, unsheathed 1100 volts grade in PVC casing caping (medium grade) of adequit size with all fittings and accessories surface type including one run 6 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694) as earth wire complete all as specified and as directed. {Note for item No. 5 & 6:- (i) Two runs of cable with one run earth wire and PVC casing caping shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the casing caping. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth. (v) (Make of cable:- NICCO / FINOLEX / RR KABEL/ HAVELL'S/ POLYCAB / KEI INDUSTRIES LTD and make of Casing Caping:- FINOLEX / PAYAL/KALINGA/ PRESTO PLAST.)}
Supply & fixing in repairs heavy duty copper pipe of size 6mm (1/4") dia/ bore complete including insulation brazing, welding, nuts, bolts and screws of required size complete all as specified and directed by Engr-in-Charge. (Make:- MALASIA/CEMIPRO/ DIAMOND/STAR)
-ditto- all as per item No. 7 above but copper pipe of size 12mm (1/2") dia/ bore.
-ditto- all as per item No. 7 above but copper pipe of size 15mm (5/8") dia/ bore.
M&L for exterior grade veneered decorative 4 mm thick plywood of grade BWR, with decorative face veneers on both faces fixed with screws to timber frame work including teak wood beadding of suitable size as required at site to cover up void portion left after installation/ removing of window type AC and other necessary fixing accessories and applying two coat of synthetic enamel paint ( 1st grade quality) over a coat of pink primer complete all as specified & as directed. (Make:- Century/ Dura/ Green ply/ Kitply.)
Supply and fixing powder coated brackets for out door unit complete with fixing nuts, bolts, washers, drilling holes/ grouting on wall complete all as specified and as directed.
Spply and fixing PVC pipe 20 mm bore/dia, medium grade with all fittings (such as bends, elbows, tees, short plugs and union etc.) fixed on wall or floor complete all as specified and as directed. (Make:- Prince/ Supreme/Ashirvad/ Prayag)
Taking out after disconnection the old/ BER window/ Split AC of any capacity and transporting/ depositing to AGE E/M (AC) store complete all as specified and as directed.
SNOWY ENGINEERING INC
RefAir Technical Services
P S TRADERS
M/s Adhikari construction co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .