Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 LAccepted-AOC 2 SURI LANE GROUND FLOOR KOLKATA 700 014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L1 | Accepted-AOC AOC is issued | |
| 2 | L2₹3.1 L+₹5,737 (1.88%)Rejected-Finance DAKHIN SHIBGANJ P O PATHAR PRATIMA SOUTH 24 PGS | PATHAR PRATIMA | SOUTH 24 PARGANAS | WEST BENGAL | 743371 | L2 | Rejected-Finance Higher bidder | |
| 3 | L3₹3.1 L+₹8,231 (2.70%)Rejected-Finance CHATAPADMAPUR BATTALA RAMNAGAR CONTAI DIST PURBA MEDINIPUR PIN 721 433 WEST BENGAL | CONTAI | PURBA MEDINIPUR | WEST BENGAL | 721433 | L3 | Rejected-Finance Higher bidder |
Tender Value
Refer Docs
EMD Value
₹6,155
Closing Date
3 Oct 2023, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Office of the Executive Engineer Purba Medinipur
Office of the Executive Engineer Purba Medinipur Electrical Division P.W.D.
Electrical Installation work to Convert the PAC room into general surgery OT at Tamluk District Hospital in the Dist of Purba Medinipur(Electric Work).(1st Re tender)
2023_WBPWD_556905_2
WBPWD/EE/PMED/NIQ-09/2023-24
Open Tender
ELECTRICAL WORKS ORG
Item Rate
10 days
tamluk
Please refer Tender documents.
3 documents required · 3 mandatory
₹6,155
Tamluk
12 Dec 2025
19 Sept 2023
5 Oct 2023
19 Sept 2023
3 Oct 2023
23 Sept 2023
22 Sept 2023
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish ,2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC incl.3 nos. (Ph, N & Earth bars) Avg. Run 8 mtr.([only PVC Rigid Conduit on ceiling and remaining portion concealed)
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR'PVC insulated & unsheathed single core stranded copper wire(Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish
a) On Board
b) Separate plug.( Avg run 7.5mtr)
S&drawing 1.1 kv single core stranded FR PVC insulated &unsheated single core stranded cupper wire (approved make)of the following sizes prelaid poly pipe. & by the Gifish wire & making necy connection as required.
a) 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC (From HTPN DB to SPN DB)
b) 2X 56/0.3( 4 sqmm) + 1 X 36/0.3( 2.5 sqmm) as ECC ( From HTPN DB to AC )
c) (3X 1.5sqmm)
d) 4X ( 10 sqmm) + 1 X ( 6 sqmm) as ECC
b) 2X36/0.3(2.5 SQMM)+1*22/0.3(1.5SQMM) as ECC (For Power Plug & Computer Point)
Cutting Channel of size (40 mm x 40 mm/ 43mm x 43mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 3 mm thick Polythene pipe (without earth continuity wire) by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles incl. S&F of following pipe.
19 mm dia pipe
Supply & Fixing 240 V, 4 nos. 16 A, 3 pin Modular type plug socket with 4 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supplying & Fixing GI 4 Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works
Supply & Fixing 240 V 16 A Piano key type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supplying and fixing 415 V, 25-32A per way, 4way TPN MCBDB with SS enclosure double-door with IP-42/43 protection with 63A Four Pole Isolators as incomer and 18 non SPMCBs ('C' Curve, 10 kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment, 1no. 63A FP Isolator, 12 no. (16-32A) SPMCB. (Make- Legrand)
Supplying and fixing 250 V, 6-10A per way, (2+8)SPN MCBDB with SS enclosure double-door with IP-42/43 protection with DP Isolators as incomer and SPMCBs ('C' Curve, 10kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment, 1no. 40A DP Isolator, 8 no. (6-16A) SPMCB). (Make- Legrand)
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
Supply & Fixing of 230V, double LED tube light fittings incl. all acc. (Make: Philips cat no.- TMC 501 P 2xT-LED 22W P3242 incl 2no. 18W master LED tube 2100 lm PC body./ Wipro/ Crompton/ Havells)suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side inserted within the ceiling reinforcement and other side connected with the suitable size of bolts and nuts incl. S&F EI conduit “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. with S & F 2x24/0.20 mm flexible copper wire of 1.10 mt. length. incl. 2nos mounting kit.
S&F Timer DB(Water Proof) concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment and febricated with following items as per instructions of EIC i) 240 V, 6-32 A SPMCB of breaking capacity 10KA & ''C'' Charecteristic -- 01 no ii) 240V 6-32 A DP MCB Isolator on din rail --- 01 No. iii) 240V , 2P, Power Contractor (rating above 20 Amp) with accessories ----- 01 no iv) Astronomical / Digital timer switch --- 01no v) Toggle switch for manual/auto operation --- 01no. vi) Double door 2+4 Way SPNDB ---- 1No vii) Necessary connection by copper wire. [Make = ABB, Simens, Legrand, L&T, Havelles or as per EIC]
Supply,Delivery, Testing & Commissioning of split type AC machines having Cooling Capacity range (5.2 kw - 5.3 kw), with fixed speed rotary compressor, refrigerant gas R410/R-32 BEE star rating -2(july22-Dec24) (EER range 3.5 minimum), Air flow range CFM (560-600), both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments(Make- Mitsubishi Electric/O-General /Sharp/Daikin)
Installation,Commissioning and testing of 2.0/1.5 ton split type AC machine both indoor/outdoor including fixing of 40 x 40 x 5 mm MS angle iron frame and mending good the damages.(incl. laboue cess)
Supply and delivery of (I) Copper pipe 3/8"/1/2" for liquid as required. (III) Copper pipe 5/8" / 1/4"for suction as required (IV) Insulation Foam 3/8" / 1/2" for liquid as required. (V) 5/8" / 1/4"for suction as required.
Supply and laying of 3 /4 core 2.5 sqmm 1.1kv grade xlpe insulated round flexible copper cable. (Make:- Havells/ Gloster/ RR Kable, Finolex,Polycab)
PVC flexible Drain pipe for drainage of water for Split A.C. both indoor and outdoor unit.
B. ENGINEERING CO.
TAPAN ELECTRICS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .