| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.4 LAccepted-AOC 218 D 1A JYANTIPUR NEAR SHYAM PIPE FACTORY SULEM SARAI PRAYAGRAJ UP | PRAYAGRAJ | PRAYAGRAJ | UP | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹26.9 L+₹1.5 L (5.92%)Rejected-Finance | L2 | Rejected-Finance Other than lowest quoted tenderer | |
| 3 | L3₹28.9 L+₹3.4 L (13.5%)Rejected-Finance M 78 GARU HARKISHAN NAGAR PASCHIM VIHAR NEW DELHI 110087 | NEW DELHI | WEST DELHI | DELHI | 110087 | L3 | Rejected-Finance Other than lowest quoted tenderer | |
| 4 | L4₹31.2 L+₹5.8 L (22.7%)Rejected-Finance | L4 | Rejected-Finance Other than lowest quoted tenderer | |
| 5 | L5₹33.5 L+₹8.0 L (31.6%)Rejected-Finance | L5 | Rejected-Finance Other than lowest quoted tenderer |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
20 Jul 2024, 6:00 pmClosed
HQ CWE Prayagraj
HQ CWE New Cantt Prayagraj
REPAIR/ MAINT OF STREET LIGHTS, GATE LIGHTS, GARDEN LIGHTS AND SOLAR LIGHTS AND BLDG LIGHTS, SUB MAIN WIRING, EARTHING AND ALLIED WORKS AT AYODHYA CANTT
2024_MES_661487_1
81898/AYD/E8
Open Tender
Civil Works
Item Rate
180 days
Ayodhya
Class D and Category b(i)
6 documents required · 6 mandatory
₹500
AGE (I) Ayodhya
₹96,000
Yes
24 Oct 2024
22 Jun 2024
27 Jul 2024
23 Jun 2024
20 Jul 2024
6 Jul 2024
Amount
Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation of poles, stays or for taking out/laying of cables and getting out in soft/loose soil complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed
Removing excavated materials (soil) n. exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
M&L for sand cushioning to underground cable with clean dry river sand complete all as specified and directed. Note:- Punned thickness only shall be measured & Paid.
Supply & Laying of sub class 'B' bricks locally available best quality laid flat (length of bricks laid across the length of cable) in tranches for protection of U/G cable complete all as specified and directed .
Supply & laying GI Pipe 25 mm dia steel tubing, galvanized light grade bores, for passing LT/HT cable under road or PCC floor or fixed on wall/on pole or drain etc or whenever protection is required including necessary clamps and nut bolts with GI fitting complete all as directed and specified
Supply & laying GI Pipe 40 mm dia steel tubing, galvanized light grade bores, for passing LT/HT cable under road or PCC floor or fixed on wall/on pole or drain etc or whenever protection is required including necessary clamps and nut bolts with GI fitting complete all as directed and specified
Supplying, laying, commissioning & testing 4 Sqmm 2 core LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of the under mentioned type and sizes complete all as specified and directed .
Supplying, laying, commissioning & testing 6 Sqmm 2 core LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of the under mentioned type and sizes complete all as specified and directed .
Supplying, laying, commissioning & testing 10 Sqmm 2 core LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of the under mentioned type and sizes complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in repair 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of twin core flat or round sheathed stranded aluminium conductor cable of size 4 Sqmm all as specified and directed .
Supplying and fixing in repair 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of twin core flat or round sheathed stranded aluminium conductor cable of size 6 Sqmm all as specified and directed .
Supplying and fixing in repair 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of twin core flat or round sheathed stranded aluminium conductor cable of size 10 Sqmm all as specified and directed .
Supply and fixing junction box made of PVC 1.6mm thick of size 230mmx170mmx105mm including 2 Nos aluminium bus bar of 2mm thick duly fitted on the suitable insulator with fixing with 35x6 mm ms flate iron with nut bolt and washer and incl one MCB SP 6 amp with rail fitted in ms box incl suitable size cable hole,gland duly painted with one coat of aluminium paint over a coate of red oxide etc complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 600mm X 600mm X 6mm thick buried directly in ground vertically to a depth not less than 2.25 meters deep below ground level with top edge of the earth plate not less than 1.5 meters deep below normal ground level, connected with and including galvanised iron 4.00 mm dia connected to main test point as directed as earthing lead by means of nuts, bolts and washers of galvanised iron protected by 40mm dia (medium grade) GI tubing, funnel, wire mesh, 20mm bore GI tubing (light grade) watering pipe, including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) type B-1 cover slab of size 350 x 350 x 50mm reinforced with 8mm dia TMT bars @ 15cm c/c in both ways and 10mm dia MS handle (01 No) of suitable size for lifting of cover slab, charcoal and salt in alternate layers including necessary excavation and earth work in soft/loose soil all as shown in Electric plate No 3 of SSR Part-I and testing on completion complete all as specified and directed.
Supply and fixing LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. all as specified and directed.
Supply and fixing LED street light fitting 100 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. all as specified and directed.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. all as specified and directed.
Supply and fixing LED street light fitting 45/50 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. all as specified and directed.
Supply and fixing LED flood light 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. all as specified and directed .
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. all as specified and directed.
Supply and fix in repair LED outdoor drivers suitable for LED street light 45 to 60 Watt all as specified and directed
Supply and fix in repair LED outdoor drivers suitable for LED street light/flood light 100 Watt all as specified and directed.
S&F in replacement of Garden/ Gate light Decorative made up of high grade unbreakable polycarbonate material powder coated including one LED lamp 14W/20W B22 base and fixed with suitable dia & height light grade GI Pipe complete all as specified and directed . Make- Havells Cat pat No :-CORALMINIPT15WLED757PSYMTO P C or equivalent to Bajaj/ Philips
S&F in replacement of Garden/ Post light Decorative made up of high grade unbreakable polycarbonate material powder coated including one LED lamp 14W/20W B22 base and fixed with suitable dia & height light grade GI Pipe complete all as specified and directed .
Supply & fix in replacement of MCCB, 4 pole, 63 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 25 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed .
Supply & fix in replacement of MCCB, 4 pole, 100 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 25 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed
Supply & fix in replacement of MCCB, 4 pole, 160 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 25 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed
S&F for MCB 230V,SPN 40 Amps, 'C' curve, 10 kA including taking out of old one and making necessary connection all as specified and as directed.
S&F for MCB 230V, single pole, 6-32 Amps, 'C' curve, 10 kA including taking out of old one and making necessary connection all as specified and as directed.
Supply & fix in replacement of All-in-One Solar Street Light 20 Watt, 12.8 Volt, 24 Amp Li-FePo4 Battery with Mppt Charge Controller Mono Solar Panel, including connection and testing complete all as specified and as directed .
Supply & fixing of 2 Pole Power Contactors 25 Amps type MNX 25 complete all as specified and as directed .
Supply & fixing of 3 Pole Power Contactors 25 Amps type MNX 25 complete all as specified and as directed .
Supply an d fixing 1.5 Sq mm PVC insulated unsheathed multistranded single core copper conductor FRLS, ISI marked cable (Red/Black colour) complete all as specified and as directed .
Supply & fixing in repair digital timer switch complete all as specified and as directed .
Supply & fixing in repair astronomical time switch complete all as specified and as directed .
Supply and fix Nature switch sensor illuminate level for switching on < 30 lux and for switching off >10 lux alongwith part night operation facility of 4-12 hours complete all as specified and as directed .
S&F for Automatic street light switch using Nature Switch for automatic switching of street lights based on lux level of natural light. The sensor (Nature Switch) alongwith and including supply and fix of suitable power contactor of 1 Nos 40 Amps (Two pole ) two Nos MCB 63 Amps (single pole) and support terminals enclosed in pole /wall mountable enclosure of suitable size made out of rust proof electric shock proof termite proof and FR grade special moulding compound sintex make SMC junction box of suitable size confirming to IP54 circuit wiring suitable enough to take load of 8 KW single phase load, complete all as specified and as directed .
Taking LT shutdown, Dismantling and removing motor of the High mast light pole from existing position, Shifting to authorized workshop for the repair work, removing the burnt winding, cleaning rotor / stator, re-winding the motor with super enameled copper wire of size equivalent to the original winding including insulated packing materials, Varnishing, Drying etc and installing back to the original position, testing and commissioning complete all as specified and as directed .
M&L for preparation of old painted surface of steel tubular street light poles and applying two coats of synthetic aluminum paint from top to bottom including light brackets complete all as specified and as directed.
M&L for Structural steel work using rolled mild steel section of Fe-290 (Gde E-165) like Angles, flat, square, round bars as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates etc complete all as specified and as directed .
M&L for Cement concrete for filling in foundations or making good of Road, PCC Floor, supports etc. Type B-1, 1:2:4, using 20 mm graded stone aggregate including necessary form work and fair finishing of exposed surface of concrete / facia finish with cement mortar complete all as specified and as directed .
M&L for Attending of day to day street/ Security/ Gate light/Post top lantern/ High Mast light fixed at up to 15 mtr height LED Flood light/ LED Street light fitting etc of any make) complaints received throuh telephone or in person and reactification of defects installed on street light pole 9/11 mtr long building walls, roof by bringing down the fittings on ground or in position including replacement of LED Driver, flexible wire, etc including cleaning of glass/ acrylic cover for clear reflection of light , replacement of old unserviceable street light fittings with new fittings etc as required to make the light fitting functional (Vehicle, ladder,tools and takes as required at site for repair/ for making light functional shall be provided by the contractor at his own cost and arrangement.
Note :- (i) light fitting, cable , flesible wire and LED drive if required to be replaced in repair shall be measered and paid separetely under relevant item of this BOQ for supply and fixing in replacement. (ii) contractor manpower should be daily receive a complaints at complaint cell at 9;00 AM by JE E/M and report after completion of complaints and handover a complaint slip as record of complaints with user signature. (iii) Old retrived material shall be deposited in AGE E/M yard and will be given to contractor after completion of contract. (iv) Quantity of material by contractor shall be decided by Engineer in charge based of requirement. Note : Recovery @ 120 per day of the complaints is not being attended within eight hours from intimation by rep of E/M subdivision through or telephonic/digital/ written complaints.
Taking down existing submain wiring of any description and M&L for sub main wiring with two runs of 6.00 Sqmm (nominal cross-sectional area) FRLS PVC insulated & unsheathed 1100 Volts grade multistranded copper conductor single core cable drawn through and including PVC concealed conduit of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLS PVC insulated & unsheathed single core multistranded copper conductor cable of size 6.0 Sqmm green in colour as earth continuity conductor connected to common earth dolly from main DB to Sub DB including cutting chases and making good in cement mortar (1:4) with all necessary surface finishes such as white / colour wash / distempering etc to match the existing surfaces complete all as specified. Note:- (i) Two runs of cable, one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length. (ii) Cable required for connection to DBs and MCBs shall be deemed included in quoted rates. (iii) Earth wire shall run inside the conduit pipe.
All as per srl item No. 44.00 here in above but submain wiring with two runs of 4.00 Sqmm FRLSH PVC insulated copper conductor and one run of 4.0 Sqmm FRLS earth continuity conductor complete all as specified and as directed.
Taking down unserviceable main switch, DB’s insulators, DB for MCB and board etc of any type and any capacity and further disposal including making good the disturbed surfaces in cement mortar (1:4) including applying white/colour wash / paint / distemper as required to match the existing surfaces complete all as specified and as directed.
S&F for epoxy powder coated MCB distribution box double door TPN 4 way horizontal type for MCBs alongwith provn of MCB as incomer with common bus-bar at incoming end of outgoing MCBs grouted / flush to wall including necessary cutting and making good disturbed surfaces in cement mortar (1:4) and applying white/colour wash / paint / distemper as required to match the existing surfaces complete all as specified and directed.
Supply and fix for epoxy powder coated MCB, DB, double door SPN 8 way for MCBs with common bus-bar at incoming end of outgoing MCBs grouted/ flush to wall complete all as specified and directed.
S&F for MCB, TPN ,100 A, 415V 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed.
S&F for LED tube light fitting,1X20 Watt surface and wall mounted decorative ultra slim square profile with extruded polycarbonate, environmental friendly, energy efficient ready to use paclk fitting including provn of twin core multi stranded copper cable of size 1.5 Sqmm from ceiling rose to tube light fitting complete all as specified and directed.
S&F in replacement, batten LED fitting 1x10 Watt, Cool Day Light (CDL), elite pride plus 5Watt 6500K LED including connection with & provn of twin core multi stranded copper cable of size 1.5 Sqmm from ceiling rose to tube light fitting complete all as specified and directed.
S&F in replacement, building security light LED 20 Watt, IP 66, including provision of GI bracket of siutable size, clamp and nut & bolt etc including PVC insulated flexible wire 3 core 23/0076 copper conductor, complete all as specified.
S&F in replacement, switch piano flush type one way 6 Amps as per existing as specified and directed
S&F in replacement, switch piano flush type one way 16 Amps as per existing as specified and directed
S&F in replacement, socket outlet 5 pin, 6 Amps flush type as per existing as directed
S&F in replacement, socket outlet 5 pin, 16 Amps flush type as per existing as directed
S&F electronic fan regulator 230 Volts, stepped type hum free 100/300 watt, complete all as specified and directed.
Taking down existing earthing of any description and M&L for new earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to GI earthing wire 4mm dia size by means of GI bolts, nuts, check nuts and washers, earthing wire protected by GI pipe 20 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6) type C1 in chamber of size not less than 300x300x300mm (internal diamentions) with cover made of RCC (1:2:4), type B-1, reinforced with 8 mm dia TMT bars @ 15 cm C/C both ways and angle iron 40X40X5mm frame etc duly painted with two coats of synthetic enamel paint over a coat of red oxided primer on exposed surfaces complete all as specified and directed Note: The unit rate includes earthing wire and protection pipe upto maximum 7.5 metre from earth plate, earth point / test point.
Yaduvanshi Traders (BID ID -3059996)
SALUJA CONSTRUCTION CO (BID ID -3060826)
Ajanta Motor Store (BID ID -3068874)
m/s allied enterprises (BID ID -3061275)
His And Her Enterprises (BID ID -3055051)
Mohinder Pal and Sons (BID ID -3059834)
VIDYA TRADERS (BID ID -3067251)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .