Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.8 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹9.6 L+₹83,070 (9.46%)Rejected-Finance 656 VINOBA BASTI SRI GANGANAGAR 335001 RAJ | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 335001 | 2 | Rejected-Finance Not Lowest | |
| 3 | 3₹9.9 L+₹1.1 L (12.4%)Rejected-Finance | 3 | Rejected-Finance Not Lowest | |
| 4 | 4₹10.8 L+₹2.0 L (22.6%)Rejected-Finance | 4 | Rejected-Finance Not Lowest |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
16 Jun 2021, 6:00 pmClosed
Garrison Engineer Abohar
Garrison Engineer Abohar Pin-152116
Repair and maint to summer appliances such as Air Conditioners, Water Coolers, Desert Cooler, Refrigeratiors, AC Plants and Voltage Stabilizers etc at Military Station Fazilka
2021_MES_444149_1
GE ABH-17/21-22
Open Tender
Civil Works
Item Rate
90 days
Fazilka Mil Stn
MES Registered Contractor enlisted in class E Category c (i) having deposited standing security of Rs 50000 with departments. Contractors not registered in MES should meet the MES enlistment criteria corresponding to appropriate class and category
6 documents required · 6 mandatory
₹500
Garrison Engineer Abohar
₹24,000
Yes
8 Jul 2021
19 May 2021
18 Jun 2021
19 May 2021
16 Jun 2021
3 Jun 2021
Amount
REPAIR TO WATER COOLERS
Labour for servicing/repairing, of water coolers of capacity 60/80/120/150 Ltr to made functional by oiling, greacing of fan motors and cleaning of water storage tank and cooling coils etc complete all as specified and as directed by Engineer-in-charge. Note :- Spare parts where ever required for replacement shall be measured and paid separately as supply & fixing.
Disconnecting, dismantling (taking out) unserviceable water coolers of 60/80/120/150 Ltr capacity, transportation from site to contractor's workshop for replacement existing burnt / unserviceable sealed unit compressor, gas-charging and back after repairing, fixing at site, commissioning and testing complete all as specified and as directed by Engineer-in-charge. Note :- Spare parts where ever required for replacement shall be measured and paid separately as supply & fixing.
Supply and replacement existing burnt / unserviceable sealed unit compressor of water cooler of capacity 40/80 litres with new sealed unit compressor from original manufacturer /authorized dealer under their exchange scheme (Replacement of old unserviceable compressor with new sealed unit compressor of same capacity and make) including gas charging, commissioning and testing including one year warranty period and etc complete all as specified and as directed by Engineer-in-charge.
All as per Srl item No. 04 (here in before) but capacity 60/120 litres
All as per Srl item No. 04 (here in before) but capacity 80/150 litres
M&L for cleaning the unit of water cooler of capacity upto 40/80 litres with Nitrogan gas and recharging with appropriate Refrigerant gas complete all as specified and as directed by Engineer-in-Charge. Note :- The type and specification of gas shall be as per manufacturers instructions of equipment and as directed by Engineer-in-Charge.
All as per Srl item No. 7 (here-in-before) but water cooler capacity 60/120 ltrs
All as per Srl item No. 7 (here-in-before) but water cooler capacity 80/150 ltrs
S&F in replacement Starting relay complete of water coolers of capacity 40/40, 40/80, 60/120, 120/150 litres etc complete all as specified and as directed by Engineer-in-charge. Make : Renutrol/Indofoss
S&F in replacement thermostat switch including plate and screw suitable for water cooler of storage capacity upto 150 litres and making necessary electric connection complete all as specified and as directed by Engineer-in-charge. Make : Indofoss / Denfoss
S&F as in replacement electric wiring kit suitable for water cooler of any make/ capacity with all connections complete all as specified and as directed by Engineer-in-charge.
S&F in replacement self closing type cast copper alloy, chromium plated water tap (ISI marked) suitable for water cooler screwed and making necessary connection etc complete all as specified and as directed by Engineer-in-charge.
S&F in replacement ball brass valve (ISI marked) 15mm bore, high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule etc complete all as specified and as directed by Engineer-in-charge.
S&F in replacement running capacitor 16 mfd etc complete all as specified and as directed by Engineer-in-charge. Make : Keil/Sharda/Tibcon
S&F in replacement Starting capacitor 80/100 mfd etc complete all as specified and as directed by Engineer-in-charge. Make : Keil/Sharda/Tibcon
S&F in replacement Running capacitor 25/36 mfd etc complete all as specified and as directed by Engineer-in-charge. Make : Keil/Sharda/Tibcon
S&F in replacement cooling coil suitable for water cooler of capacity 60/120 litres complete all as specified and as directed by Engineer-in-charge. Make : USHA / VOLTAS/ SRI RAM
S&F in replacement new blower motor for water cooler of capacity 80/150 litres etc complete all as specified and as directed by Engineer-in-charge. Make : USHA / VOLTAS/ KHAITAN
S&F in replacement new blower motor for water cooler of capacity 60/120 litres etc complete all as specified and as directed by Engineer-in-charge. Make : USHA / VOLTAS/ KHAITAN
S&F in replacement new blower motor for water cooler of capacity 40/80 litres etc complete all as specified and as directed by Engineer-in-charge. Make : USHA / VOLTAS/ KHAITAN
S&F as in replacement stainless steel tray 1mm thick, for waste water for water cooler of capacity 40/80 litres etc complete all as specified and as directed by Engineer-in-charge.
Material & labour for spray painting the water cooler of storage capacity 60/ 80 litre with one coat of ducco paint over a coat of red oxide primer including preparing the existing painted surface and writing MES / SM No. with black & synthetic enamel paint etc complete all as specified and as directed by Engineer-in-charge.
Material & labour for spray painting the water cooler of storage capacity upto 120/150 litre with one coat of ducco paint over a coat of red oxide primer including preparing the existing painted surface and writing MES / SM No. with black & synthetic enamel paint etc complete all as specified and as directed by Engineer-in-charge.
REPAIR TO WINDOW / SPLIT TYPE AIR CONDITIONERS
Labour for servicing/repairing, of split/window type Air conditioners of capacity 1.5/2.0TR to made functional by oiling, greecing of fan motors and cleaning of filter and cooling coils etc complete all as specified and as directed by Engineer-in-charge. Note :- Spare parts where ever required for replacement shall be measured and paid separately as supply & fixing.
Disconnecting, dismantling (taking out) unserviceable split/ window type Air conditioners of capacity 1.5/2.0TR, transportation from site to contractor's workshop for replacement of existing burnt / unserviceable sealed unit compressor, gascharging and back after repairing, fixing at site, commissioning and testing complete all as specified and as directed by Engineer-in-charge. Note :- Spare parts where ever required for replacement shall be measured and paid separately as supply & fixing.
Disconnecting, dismantling (taking out) existing burnt/ unserviceable uncut type compressor unit from the AC and provision of new compressor to be got replaced from original manufacturer/authorized dealer under their exchange scheme (Replacement of old unserviceable compressor with new sealed unit compressor of same capacity and make) with renewal warranty of one year with relay terminal box suitable for 1.5 ton capacity window type air conditioner including necessary gas charging, transportation to workshop & back complete all as specified and as directed by Engineer-in-charge.
Disconnecting, dismantling (taking out) existing burnt/ unserviceable uncut type compressor unit from the AC and provision of new compressor to be got replaced from original manufacturer/authorized dealer under their exchange scheme (Replacement of old unserviceable compressor with new sealed unit compressor of same capacity and make) with renewal warranty of one year with relay terminal box suitable for 2 ton capacity window type air conditioner including necessary gas charging, transportation to workshop & back complete all as specified and as directed by Engineer-in-charge.
Disconnecting, dismantling (taking out) existing burnt/ unserviceable uncut type compressor unit from the AC and provision of new compressor to be got replaced from original manufacturer/authorized dealer under their exchange scheme (Replacement of old unserviceable compressor with new sealed unit compressor of same capacity and make) with renewal warranty of one year with relay terminal box suitable for 1.5 ton capacity split type air conditioner including necessary gas charging, transportation to workshop & back complete all as specified and as directed by Engineer-in-charge.
Disconnecting, dismantling (taking out) existing burnt/ unserviceable uncut type compressor unit from the AC and provision of new compressor to be got replaced from original manufacturer/authorized dealer under their exchange scheme (Replacement of old unserviceable compressor with new sealed unit compressor of same capacity and make) with renewal warranty of one year with relay terminal box suitable for 2 ton capacity Split type air conditioner including necessary gas charging, transportation to workshop & back complete all as specified and as directed by Engineer-in-charge.
S&F in replacement double shaft blower fan motor, single phase, 230 volt with fan assembly suitable for 1.5/2.0 ton capacity window AC complete all as specified and as directed by Engineer-in-charge. Make: Khaitan / VOLTAS / USHA
S&F in replacement knob with screw for AC including making necessary connections complete (as per sample) all as specified and as directed by Engineer-in-charge.
S&F in replacement running capacitor 36 mfd including making necessary connections and testing complete all as specified and as directed by Engineer-in-charge. Make : Usha / Unistar / BHEL / Ramco
S&F in replacement thermostat switch with plate and screws suitable for window type air conditioners upto 1.5 ton capacity including making necessary connections and testing complete all as specified and as directed by Engineer-in-charge. Make : Renutrol/ Indofoss
S&F in replacement over load protector suitable for 1.5/2.0 ton capacity window type air conditioner complete all as specified and as directed by Engineer-in-charge. Make : SRI RAM / Renutrol / Indofoss
S&F in replacement over load protector suitable for 1.5/2.0 ton capacity split type air conditioner complete all as specified and as directed by Engineer-in-charge. Make : SRI RAM / Renutrol / Indofoss
S&F in replacement starting relay suitable for Air Conditioner 1.5/2 ton capacity complete all as specified and directed by Engineer-in-Charge.
S&F as in replacement electric wiring kit suitable for 1.5/2 ton capacity window/ split type air conditioner with all connections complete all as specified and as directed by Engineer-in-charge.
S&F in replacement front grill (as per sample kept in GE’s Office) of AC capacity 1.5 /2 ton complete all as specified and as directed by Engineer-in-charge.
Cleaning the gas system with CO2 Gas and gas charging complete of window/ split type AC all as specified and as directed by Engineer-in-Charge. Note :- The type and specificatin of gas shall be as per manufacturers instructions of equipment and as directed by Engieer-in-Charge.
Taking down cooling split type air conditioners of 1.5/2.0 Ton capacity for alterations to existing only cooling type air conditioner modifying as cooling & heating system by positioning a module of Hot and Cold air conditioning to the existing and testing the same complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement PCB remote plate of split AC of capacity 1.5/2.0 TR complete with remote all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement of PVC blower suitable for split AC of capacity 1.5/2.0 TR complete with remote all as specified and as directed by Engineer-in-charge.
Supply and fixing indoor unit of split type AC of capacity 1.5 TR including cooloing coils and connecting items complete with remote all as specified and as directed by Engineer-in-charge.
Supply and fixing out door unit of split type AC of capacity 1.5 TR including connecting items such as condenssor coil, compressor, fan motor fan blade and electric works complete with remote all as specified and as directed by Engineer-in-charge.
REPAIRS TO REFRIGERATORS
Disconnecting, dismantling (taking out) unserviceable Refrigerators of capacity 165-310 Ltr, transportation from site to contractor's workshop for replacement of existing burnt / unserviceable sealed unit compressor, gascharging and back after repairing, fixing at site, commissioning and testing complete all as specified and as directed by Engineer-in-charge. Note :- Spare parts where ever required for replacement shall be measured and paid separately as supply & fixing.
Disconnecting, dismantling (Taking out) existing burnt /unserviceable sealed unit compressor of refrigerator of capacity 165 litres and provision of new sealed unit compressor from manufacturer/authorized dealer under their exchange scheme (Replacement of old unserviceable compressor with new sealed unit compressor of same capacity and make) and fixing, commissioning and testing including one year guarantee and necessary gas charging including transportations to work shop and back etc complete all as specified and as directed by Engineer-in-Charge.
All as per Srl item No. 50 (here-in-before) but 310 litres capacity
S&F in replacement thermostat switch suitable for 310/165 ltrs refrigerator complete all as specified and as directed by Engineer-in-Charge. Make : Danfoss/Indofoss
S&F in replacement type starting relay 1/6 HP to 1/10 HP suitable for refrigerator of capacity 165/286/310 litres including thimbles and screws etc complete all as specified and as directed by Engineer-in-charge. Make : Renutrol/Indofoss
S&F in replacement over load protector suitable for refrigerator of capacity upto 310/165 ltr etc complete all as specified and as directed by Engineer-in-charge. Make : SRI RAM / Renutrol
S&F in replacement cooling coil suitable for refrigerator of capacity upto 165 litres complete all as specified and as directed by Engineer-in-charge. Make : GODREJ / VOLTAS/ LG / SAMSUNG
S&F in replacement Vegetable tray suitable for refrigerator of capacity upto 165 ltr complete all as specified and as directed by Engineer-in-charge.
S&F in replacement Vegetable tray suitable for refrigerator of capacity upto 286/300 ltr complete all as specified and as directed by Engineer-in-charge.
S&F in replacement Ice chamber (freezer box) including freezer cover suitable for refrigerator of capacity upto 165 ltr complete all as specified and as directed by Engineer-in-charge.
S&F in replacement Ice chamber (freezer box) including freezer cover suitable for refrigerator of capacity upto 286/300 ltr complete all as specified and as directed by Engineer-in-charge.
Cleaning the unit with CO2 Gas and recharging of gas complete of refrigeator capacity 165/200 ltrs complete all as specified and as directed by Engineer-in-Charge. Note :- The type and specification of gas shall be as per manufacturers instructions of equipment and as directed by Engineer-in-Charge.
Cleaning the unit with CO2 Gas and recharging of gas complete of refrigeator capacity 300/310 ltrs complete all as specified and as directed by Engineer-in-Charge. Note :- The type and specification of gas shall be as per manufacturers instructions of equipment and as directed by Engineer-in-Charge.
Material & labour for spray painting the refrigerator of capacity 165 litres with one coat of ducco paint over a coat of red oxide primer including preparing the existing painted surface and writing MES / SM No. with black & synthetic enamel paint etc complete all as specified and as directed by Engineer-in-charge.
Material & labour for spray painting the refrigerator of capacity 310 litres with one coat of ducco paint over a coat of red oxide primer including preparing the existing painted surface and writing MES / SM No. with black & synthetic enamel paint etc complete all as specified and as directed by Engineer-in-charge.
REPAIR TO DEEP FREEZER
Disconnecting, dismantling (taking out) unserviceable deep freezers of capacity 200-405 Ltr, transportation from site to contractor's workshop for replacement of existing burnt / unserviceable sealed unit compressor, gascharging and back after repairing, fixing at site, commissioning and testing complete all as specified and as directed by Engineer-in-charge. Note :- Spare parts where ever required for replacement shall be measured and paid separately as supply & fixing.
Disconnecting, dismantling (taking out) existing burnt/ unserviceable uncut type compressor unit from Deep freezer of capacity 305/ 405 litres capacity and provision of new compressor to be got replaced from original manufacturer/authorized dealer under their exchange scheme (Replacement of old unserviceable compressor with new sealed unit compressor of same capacity and make) with renewal warranty of one year including necessary fixing, commissioning, testing and gas charging, transportation to workshop & back complete all as specified and as directed by Engineer-in-charge.
Disconnecting, dismantling (taking out) existing burnt/ unserviceable uncut type compressor unit from Deep freezer of capacity 200 litres capacity and provision of new compressor to be got replaced from original manufacturer/authorized dealer under their exchange scheme (Replacement of old unserviceable compressor with new sealed unit compressor of same capacity and make) with renewal warranty of one year including necessary fixing, commissioning, testing and gas charging, transportation to workshop & back complete all as specified and as directed by Engineer-in-charge.
S&F in replacement thermostat switch suitable for 200-405 Ltr deep freezers complete all as specified and as directed by Engineer-in-Charge. Make : Danfoss/Indofoss
S&F in replacement type starting relay 1/6 HP to 1/10 HP suitable for refrigerator of capacity 200-405 Ltr deep freezers including thimbles and screws etc complete all as specified and as directed by Engineer-in-charge. Make : Renutrol/Indofoss
S&F in replacement over load protector suitable for 200-405 Ltr deep freezers etc complete all as specified and as directed by Engineer-in-charge. Make : SRI RAM / Renutrol
S&F in replacement cooling coil suitable for 200-405 Ltr deep freezers complete all as specified and as directed by Engineer-in-charge. Make : GODREJ / VOLTAS/ LG / SAMSUNG
Cleaning the unit with CO2 Gas and recharging of gas complete of deep Freezers capacity 200 Ltrs complete all as specified and as directed by Engineer-in-Charge. Note :- The type and specification of gas shall be as per manufacturers instructions of equipment and as directed by Engineer-in-Charge.
Cleaning the unit with CO2 Gas and recharging of gas complete of deep Freezers capacity 305/405 Ltrs complete all as specified and as directed by Engineer-in-Charge. Note :- The type and specification of gas shall be as per manufacturers instructions of equipment and as directed by Engineer-in-Charge.
Material & labour for spray painting Deep Freezers of capacity 200 Litres with one coat of ducco paint over a coat of red oxide primer including preparing the existing painted surface and writing MES / SM No. with black & synthetic enamel paint etc complete all as specified and as directed by Engineer-in-charge.
Material & labour for spray painting Deep Freezers of capacity 305/405 Litres with one coat of ducco paint over a coat of red oxide primer including preparing the existing painted surface and writing MES / SM No. with black & synthetic enamel paint etc complete all as specified and as directed by Engineer-in-charge.
REPAIR TO DESERT COOLERS
S&F in replacement vertical pump (tullu pump) for desert cooler including making necessary connections complete all as specified and as directed by Engineer-in-charge. Make: Air King / Khaitan / Bajaj
S&F in replacement fan motor 400mm sweep including blades and brackets of desert cooler complete all as specified and as directed by Engineer-in-charge. Make: Cool Home / KHAITAN / Crompton / Bajaj
S&F in replacement fan motor 450mm sweep including blades and brackets of desert cooler complete all as specified and as directed by Engineer-in-charge. Make: Cool Home / KHAITAN / Crompton / Bajaj
S&F in replacement cooling pad (set of three) of desert cooler (as per sample kept in GE’s Office) of any size complete all as specified and as directed by Engineer-in-charge.
S&F in replacement PVC white pipe of size 15 mm bore as approved complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of PVC insulated unarmored copper cable of size 3 Core, 40/0.0076 complete all as specified and as directed by Engineer-in-charge. Make : Plaza/Finolex/Paragon
S&F in replacement running capacitor 4 Mfd oil filled including making necessary connections and testing complete all as specified and as directed by Engineer-in-charge. Make: Usha / Unistar / Tibcon
Material & labour for spray painting to desert cooler with one coat of synthetic enameled anti corrosive paint using spray machine including preparation of surfaces and writing MES / SM No. with black paint on inner side of water tank etc complete all as specified and as directed by Engineer-in-charge.
S & F in replacement plug top, 6 Amp, 3 Pin, ISI marked complete all as specified and directed by Engineer-in-Charge.
S&F in replacement ball brass valve (ISI marked) 15mm bore, high pressure with polythene float and connecting rod suitable for iron pipe or brass ferrule etc complete all as specified and as directed by Engineer-in-charge.
S&F in replacement PVC connection 15mm dia, 450mm long with both end brass ferrule suitable for GI pipe complete all as specified and as directed by Engineer-in-charge.
Supply & fixing GI tubing 15mm bore dia alongwith wall/floor including GI fittings such as elbow, sockets,unions clamps complete all as specified and as directed by Engineer-in-charge.
Supply & fixing brass stop cock suitable for 15mm bore GI pipe complete all as specified and as directed by Engineer-in-charge.
REPAIR TO VOLTAGE STABILIZERS
Dismantling voltage stabilizer of capacity 1 KVA to 6 KVA single phase 240 volt AC of any make and any Size for inspection, necessary repair and replacement of worn out/defective spare parts, reassembling, connecting up, testing etc complete all as directed(Necessary spare parts required for replacement shall be measured and paid for separately as supply only)
Supply only transformer suitable for voltage stabilizer of capacity 3 KVA of existing make and size complete all as specified and as directed
All as per Srl item No.94 here-in-before but capacity 4 KVA
All as per Srl Item No.94 here-in-before but capacity 5 KVA
All as per Srl Item No.94 here-in-before but capacity 6 KVA
Supply only circuit diagram plate suitable for voltage stabilizer of capacity upto 3 KVA of existing make and size complete all as specified and as directed.
Supply only volt meter capacity 0-300 volt AC for stabilizer 3 KVA to 5 KVA complete all as specified and as directed
Supply only out put terminal plate as per existing size and all as directed
REPAIR/MAINT FOR CEILING/EXHAUST FANS
Taking down/ dismantling complete ceiling fan of size 1200/1400 mm sweep down rod with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan,cutting the unserviceable winding of starter, rotor and taking out ball bearing, gun metal bush etc. complete to carry out the following repairs :- (a) Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as specified and directed and re-assembling complete ceiling fan fixing only with old/new spare parts (i.e.) rubber bush of shackle and condenser housing, condenser, gun metal bushes, ball bearing, twin twisted copper cable, etc complete all as specified and directed by Engineer-in-charge. (Note :- 1. Ball bearing, Gun metal bush and condensor are measured and paid separately as supply only rates and minor spares like rubber bush shackle,holder deemed to beinclude in quoted rates). 2. Repair/Rewinding of fan shall be carried out in MES yard to bring adequate winding machine,tools & plants and necessary motor winder at site as directed.
All as per Item No.102 here-in-before but exhaust fan of size 220/250/300/380/450 mm sweep.
All as per Item No.102 here-in-before but pedestal/Air circulator fan of size 400/450/600 mm sweep.
Taking down ceiling fan of 1200/1400 mm sweep by unscrewing nut/bolts from its position and fixing the same to its original place after necessary cleaning, oiling, greasing, servicing/overhauling and replacement of bush, bearing, condenser complete all as specified and directed and writing MES number as as directed by Engr-in-Charge. (Note :1. Bush, condensor, ball bearing are measured and paid separately as supply only rates and minor spares like , rubber bush shackle,holder deemed to be include in quoted rates ) 2. Repair/Servicing of fan shall be carried out in MES yard/User site to bring adequate serviceable condition winding machine,tools & plants and necessary motor winder at site as directed.
All as per item No 105 here in before but exhuast fan 220/250/300/380/450 mm sweep complete all as specified and directed and marking MES number ass as directed by Engr-in-Charge
Taking down/ dismantling complete ceiling fan of size 1200/1400 mm sweep down rod with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, including filling the cavities with filler material and painting of ceiling fan by scraping/removing old spray paint with brush/emery paper and spray painting with two coat of synthetic enamelled paint after reassembling spares for serviceable condition complete all as specified and directed and marking MES number ass as directed by Engr-in-Charge. Note: 1. painting of fan shall be carried out in MES yard/User site to bring adequate winding machine,tools & plants and necessary motor winder at site as directed.
All as per Item No.107 here-in-before but exhaust fan of size 220/250/300/380/450 mm sweep.
All as per Item No.107 here-in-before but pedestal/Air circulator fan of size 400/450 mm sweep.
Supply only ball bearing number of 6201/6202/6203/6204 as required complete all as specified and directed. (Make : SKF/NBC).
Supply only gun metal bush as per existing specification and make as per sample and confirming to ISI complete all as specified and directed.
S&F for Condenser 2/2.5/3.15.4.0 MFD as per existing capacity and make as per sample and confirming to ISI complete all as specified and directed. (Make : Universal/Standard/Jyoti/Usha)
S&F for PVC holder for condenser housing as per existing capacity and make as per sample and confirming to ISI complete all as specified and directed.
S&F for rubber bush for shackle with bolt, nut and lock pin suitable for ceiling fan 1200mm/1400mm sweep.
S&F for twin core twisted copper flexible wire/cable of size 23/0.0076 complete all as specified and directed (Make : Finolex/Nicco/KDK/KEI/Havells/HPL)
Supply only canopy top/bottom with U clamp suitable for ceiling fan 1200/1400mm sweep suitable matching color as exising complete all as specified and directed
Supply only down rod 300 mm long of size 20 mm dia for ceiling fan complete all as specified and directed.
Supply only ceiling fan blades suitable for 1200/1400 mm sweep suitable for exising make & type as per sample complete all as specified and directed.
Supply only Exhasust fan blades suitable for 1200/1400 mm sweep suitable for exising make & type as per sample complete all as specified and directed.
Supply only exhaust fan canopy suitable size as per exising size of fans 220/250/300/380/450 mm suitable to matching color complete all as specified and directed
Supply only exhaust fan Louvers GI/MS/PVC suitable to size as per exising fans 220/250/300/380/450 mm complete all as specified and directed
Supply only fan regulator electronic (socket) type, single phase, 230Volt complete all as specified and directed Make: Anchor/Cona and equivalent make
Material and labour for making hole of size 220/250/300/380/450 mm round/Square as required for exhaust fan vent to using suitable tools without disturbing other surface and make good with cement plaster and exising color white wash/distemper/putty as existing color and surface including grouting bolts, nuts into wall for fixing exhaust fan complete all as specified and directed.
jassal engineering
SHRI RAM TRADING CO.
HARSH CONSTRUCTION CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .