Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹13.5 LAccepted-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | 1 | Accepted-AOC Lowest | |
| 2 | 2₹15.3 L+₹96,190 (6.71%)Rejected-Finance | 2 | Rejected-Finance Higher | |
| 3 | 3₹18.2 L+₹3.8 L (26.6%)Rejected-Finance | 3 | Rejected-Finance Higher |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
20 Nov 2020, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Amritsar
GE Amritsar PIN-143001
REPAIR/REPLACEMENT OF LT OH LINES AND CONNECTED ITEMS OF EXTERNAL ELECTRIC SUPPLY AT OLD AMRITSAR CANTT
2020_MES_385283_1
GE/ASR-34/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE Amritsar
Class E, Category bi
8 documents required · 8 mandatory
₹500
GE Amritsar
₹30,000
Yes
3 Dec 2020
24 Oct 2020
21 Nov 2020
24 Oct 2020
20 Nov 2020
7 Nov 2020
60 days
Amount
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for laying of cables, HT / LT poles, stay assembly etc and getting out in hard / dense soil complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
Material & labour for cross arms, bracing, supports, clamps and back plate, fabricated from structural steel sections including nut-bolts and washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and applying two coats of aluminium paint over one coat of red oxide primer complete including taking down old unseviceable materials all as specified and directed.
Material & labour for supply , stringing, stretching and strengthening of overhead conductor (ACSR) on existing LT PCC/steel tubular pole including binding and jointing the conductor with and including 14 SWG binding wire all as specified and directed.
Supply & fixing of continuous GI earth wire/guard/ cradles as required and directed, fabricated out of 4 mm dia GI wire including 14 SWG binding wire complete all as specified and directed.
Dismantling / taking out old ACSR conductor / copper conductor / GI earth wire any size from existing overhead lines including disconnection complete all as specified and directed.
Supply & fixinng of shackle type insulator, porcelain, vitreous, white, brown or green insulator of size 75 mm height and 90 mm dia for working pressure of 1100 volts, LT complete with galvanised mild steel strap of size 31 X 3 mm / flat iron 50 X 6 mm ‘D’ clamp or ‘U’ clamp of suitable size and holding clamp, washers, insulator bolts of 12 mm dia, washers and nuts complete all as specified and directed.
Re-stretching/stringing only existing ACSR of any size on LT pole including binding the ACSR with insulator, aluminium binding wire complete all as specified and as directed. Note :- One length shall be measured for complete 4 to 6 conductors & GI wire.
Taking down old broken PVC separator from LT overhead line and Supply & fixing in replacement plastic (moulded polypropylene) line phase separator (for separating 05 Nos. of over head line conductors of length 1200 mm) with 25 mm fly nuts and clamps suitable for 1100 volts grade LT electric lines of any size fixed with over head electric lines complete all as specified and directed.
Supply & fixing 50 mm bore light grade galvanised iron tubing with all necessary GI fittings as in protection pipe of cable, fixed to pole or laid under floor / ground / under road crossings for protection of cable complete all as specified and directed.
Supply & fixing of 80 mm bore light grade galvanised iron tubing with all necessary GI fittings as in protection pipe of cable, fixed to pole or laid under floor / ground / under road crossings for protection of cable complete all as specified and directed.
Material & labour for supply, transporting, erecting truly in vertical position and fixing of steel tubular pole swaged, over all length 9 metres, type 410 – SP – 31 complete with mild steel base plate, pole cap, finial taper plug, MS bolts, nuts & washers and painting of pole with two coats of anti corrosive black bituminous paint through out internally and externally upto planting depth (embedded in concrete) and remaining portion of the pole painted two coats of aluminium paint over a coat of red oxide primer on complete exposed surface including painting of 05 Nos. bands / strips of 30 cm wide each with two coats of synthetic enamel paint (black & yellow) at a distance of 30 cm from plinth block upto 1500 mm height and marking / sign writing of pole number and feeders locations of pole with thick synthetic enamel paint (white) complete all as specified and directed. ( Note : PCC and earth work, clamps shall be meassured and paid separately under respective item of Sch A ).
Supply and fix stay assembly comprising of GI stay bow 14mm dia, 40cm long, galvanised stay rod 20mm dia, 215cm long with threaded ends, GI nuts, bolts, washers, stay plate 30x30cmx6mm thick, 02 Nos of thimbles, MS clamps made out of 50x6mm flat iron and stay wire 7/3.15 SWG complete including necessary excavation, earth work and PCC 1:3:6 all as shown in electrical plate No. 01 of SSR-1996. ( Note : PCC and earth work, loop type insulator, stay clamps shall be meassured and paid separately under respective item of Sch A ).
Dismantling / taking out of old LT PCC/Steel tubular pole any type and any size from foundations including dismantling of concrete, MS clamps, nuts-bolts, earth wire, over head line conductors, insulators, guarding cradles and other accessories including necessary excavation and earth work in any type of soil complete all as specified and directed.
Dismantling of existing stay assembly any type / size from its stay rod, cutting stay rod (above ground portion) dismantling of MS clamps, nut-bolts, stay bow, loop insulators, stay wire etc. complete all as specified and directed.
Dismantling / taking out old unserviceable insulator of any size / type from existing electric LT lines complete all as specified and directed.
Material & labour for preparation of old painted steel and iron surfaces and painting to steel tubular poles of any height 9/11/13 metre, any type (double swan / single swan) with two coats of synthetic enamel paint upto 1.5 m height above from ground level (in yellow and black strips of 30 cm wide each) and applying two coats of aluminium paint above 1.5 m height of poles incl painting on cross arms, bracing, clamps etc and writing pole Nos. with thick black synthetic enamel paint complete all as specified and directed.
Material & labour for clearing of LT line by triming, cutting, pruning of tree branches of any girth projected on overhead line and removal from site upto 50 mtr distance complete all as specified and directed.
M & L PCC 1:4:8 type D-2, using stone aggregate 40mm graded as in foundation for electric poles including necessary form work where required all as specified & directed by Engr-in-charge.
All as per srl item No 19 here-in-before but PCC 1:3:6 type C-2 as in foundation of stays and coping of poles
Supply & fixing loop type insulator, porcelain, vitreous, white, brown or green insulator large size with over all dimention 90mm X140 mm, clearance of hole 25.50 mm complete all as specified and directed.
Supply & fixing in replacement of LT jumper of 120 sqmm single core aluminium cable conductor incl PG Clamps, nut bolts, thimbles and washer required at site complete all as specified and directed.
Material and labour for cleaning away all grass vegetation sapling shrubs bushes from under roots and tress not exceeding 30 cm girth and removing upto distance of 50 mtr out the periphery of area under cleanness including levelling of the area complete all as specified and directed. Note : T & P required for this job to be brought by the contractor.
Material & labour for earthing complete with galvanised earth plate electrode 600 X 600 X 6 mm thick burried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate), duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate), GI protection pipe light grade 15 mm bore up to 7.5 m length from earth electrode & engraving of earth marking on nearby building with CM 1:4 plate size 200 X 150 X 15 mm & painting of earth result etc. including testing on complete all as specified and directed.
M & L for earthing complete with galvanised earth plate electrode 600 X 600 X 6 mm thick burried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth strip 32 X 6 mm size by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate), duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate), GI protection pipe light grade 40 mm bore up to 7.5 m length from earth electrode & engraving of earth marking on nearby building with CM 1:4 plate size 200 X 150 X 15 mm & painting of earth result etc. including testing on complete all as specified and directed. NOTE: - ON TESTING AFTER COMPLETION OF JOB, IF DESIRED EARTH RESISTANCE IS NOT OBTAINED, THE EARTHING SHALL BE REDONE BY THE CONTRACTOR WITHOUT ANY EXTRA COST TO GOVT.
Supply only best quality wooden Bamboo ladder min height 11 mtr suitable for HT Pole step to step standared height complete.
Supply only best quality wooden Bamboo ladder min height 9 mtr suitable for LT Pole step to step standared height complete.
Supply and fixing in repairs, installation, commissioning and testing CPRI approved factory made LT feeder pillar box , double door, outdoor ,FRONT& REAR OPENABLE type totally enclosed free pedestal mounting dust and vermin proof, weather proof made out of 3.15 mm thick CRCA mild steel (certificate from manufacturer will be necessary for quality aasurance and gurantee) as per IS: 8623 rated for short circuit rating of 36 KA ,base frame of 50mm x 50mm x 5mm,with hinges of stainless steel,slider door locks(front &rear ) ,door handles (front&rear) suitable for 415 Volts, 3 phase, 4 wire, 50 Hz, AC supply outdoor type complete with and including incoming and outgoing moulded case circuit breakers, aluminium bus bar including internal wiring with not less than PVC insulated unsheathed 2.5 Sqmm multi stranded copper conductor cable, bonding to earth interconnection complete as required and as approved from CPRI all as specified and directed : Note : Outer dimension of panel should be minimum width =3mtr, Depth = 0.8 mtr, Hieght = 2.5 mtr hight or more than this as design of the panel manufacture. Incoming (a) ACB of Cap 800 Amp, 4 pole, 50 KA, , lcu=lcs=low rated for 1 sec 415 volt, 50 Hz - 01 Nos Manual drawout type, microprocessor relaease complete all as specified and directed. Make Legrand(DMX SP 2500)/Schneider/Siemens Out going (a) MCCB of Cap 400 Amp, 4pole, 36 KA,Microprocessor based, 415 volt, 50 Hz MCCB - 01 Nos Make Legrand(DPX3) / Schneider(NSX) / Siemens(3VL) (b) MCCB of Cap 250 Amp, 4pole, 25 KA,Microprocessor based, 415 volt, 50 Hz MCCB - 06 Nos Make Legrand / Schneider / Siemens (c) Aluminum BUS BAR SUITABLE FOR 1000 A ,SIZE 100 mm*10mm (R Y B N) COVERED WITH HEAT SHRINKABLE COLOUR CODED SLEEVES (d) Digital LCD MULTIFUNCTIONAL METER,Class. 1 .0 ACCURACY DISPLAYING VOLTAGE ,CURRENT of all type of phase ,FREQUENCY complete with 3 CTs of suitable size -01 No (e) L E D indicating lamps (R, Y & B) PROTECTED WITH 2A SP MCB'S - 01 set of three lamps (f) EARTHING STRIP OF SIZE 25mm*5mm OF ALUMINIUM RUNNING THROUGHOUT THE LENGTH OF THE SUBJECT L T PANEL
Supply and filling of distilled water for battery bank of 110 V DC at power house and MRS, in necessary containers and filling in the battery carefully complete including cleaning of terminals of the batteries using appropriate chemical complete all as specified and directed by Engr-in-Charge
Bharat Builder
Rishi Construction Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .