3 Jul 2021, 6:00 pmClosed
GE AF NAGPUR
OFFICE OF GARRISON ENGINEER AIR FORCE VAYUSENA NAGAR NAGPUR- 440007
REPAIR TO ROOF TREATMENT AND PLUMBING WORKS TO CERTAIN BUILDINGS IN ZONE A AREA AT VSN NAGPUR
2021_MES_438714_2
GE/NAG/21-22/8449/12
Open Tender
Civil Works
Item Rate
180 days
GE AF NAGPUR
as per NIT
7 documents required · 7 mandatory
₹500
GE AF NAGPUR
₹30,000
8 Jul 2021
12 Jun 2021
5 Jul 2021
12 Jun 2021
3 Jul 2021
26 Jun 2021
Amount
Taking down carefully existing bitumen tar felt including plaster, concrete/brick coba /tiling from the roof /parapets till RCC slab and roughening the surface ,wire brushing , cleaning and washing with water etc., and removing the rubbish to a distance exceeding 1.5km outside the VSN and depositing where directed complete all as specified and directed.
Taking down carefully existing bitumen tar felt including plaster and roughening the surface ,wire brushing , cleaning and washing with water etc., and removing the rubbish to a distance exceeding 1.5km outside the VSN and depositing where directed complete all as specified and directed
All as per item no. 2 herein above but on vertical surfaces like parapet except brick coba/tilling etc complete all as specified and directed
Material and labour for roof treatment on RCC roof slab complete as mentioned below, all as specified and as directed:- (i) Cleaning the concrete surfaces of RCC roof slab thoroughly with wire brushes, washed and dried. (ii) Checking the roof slab by flooding test with water till total elimination of leakage/seepage/ dampness all as specified in SSR Part-I (after ascertaining location of leakage/seepage/ dampness, carrying out treatment vide relevant item of pressure grouting shall be operated at the required locations). (iii) Brushing surface with neat cement slurry at the rate of 3.00kg of cement per Sqm. (iv) Cleaning the plastered roof surfaces and applying a coat of bitumen primer @ 0.3 kg/sqm on top of dry surface. (v) Laying APP modified polymeric membrane 3mm thick with non woven polyester core laid and bonded to the sub-strata and over-laps shall be sealed/fused by flame "torch', application method all as per manufacturer's instructions. (vi) Applying bitumen base aluminium paint at 0.2 kg/Sqm in two coats over APP modified polymer
Material and labour for roof treatment on accesible RCC roof slab complete as mentioned below, all as specified and as directed:- (i) Cleaning the concrete surfaces of RCC roof slab thoroughly with wire brushes, washed and dried. (ii) Checking the roof slab by flooding test with water till total elimination of leakage/seepage/ dampness all as specified in SSR Part-I (after ascertaining location of leakage/seepage/ dampness, carrying out treatment vide relevant item of pressure grouting shall be operated at the required locations). (iii) Brushing surface with neat cement slurry at the rate of 3.00kg of cement per Sqm. (iv) Cleaning the plastered roof surfaces and applying a coat of bitumen primer @ 0.3 kg/sqm on top of dry surface. (v) Laying APP modified polymeric membrane 3mm thick with non woven polyester core laid and bonded to the sub-strata and over-laps shall be sealed/fused by flame "torch', application method all as per manufacturer's instructions. (vi) A coat of hot blown bitumen @1.2Kg/sqm shall be applied over polymeric membrane and blinded with clean dry sand at the rate of 0.5 kg/sqm
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premisess complete all as specified and directed
M&L for Screed bed or bedding layer of mortar 20 mm thick in CM 1:4 with WPC for laying floor finishes all as specified and directed.
M&L for Cement concrete tiles 25cm x 25cm x 22mm thick, machine pressed; set jointed and pointed with chemical compound as per manufactures instruction as approved by GE all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in filleting and benching slightly rounded off etc. Including necessary form work, if any, complete all as specified and as directed.
Material and labour for grouting in roof through PVC nipples at a spacing of 45 to 60cm C/C including drilling injection points to a depth of 75-100mm, providing 10mm dia PVC nipples and pressure grouting using with and including cement mixed with plasticizing admixture like FOSROC (model CEBEX100) or PIDILITE (model 207 PIDICRET 8AM) @ 225gms/50kg of cement to fill up all capillaries/ voids/ honeycombing areas inside concrete with pressure of 2 to 4 Kg/Sqcm and continued till refusal. After grouting, nozzles to be sealed with the sealing compound/mortar etc, all as per manufacturers instructions complete all as specified and directed. Note:- After ascertaining the location of leakage/ seepage/dampness under relevant item, this item shall be operated at the required location.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate RCC roof slabs to fill undulations to achieve uniform slope complete all as specified and directed.
M&L for rendering over roof slab 10 mm thick in CM 1:3 on concrete surfaces mixed with water proofing compound @ 3% by weight of cement and finished surfaces fair and even all as specified and directed. (WPC shall be measured and paid separately)
Supply only integral water proofing compound all as specified and directed.
Demolition of brick masonry, built in cement mortar and removal of debris from site all as specified and directed.
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. all as specified and as directed.
M&L for Rendering 15 mm thick in CM 1:4 mixed with water proofing compound @ 3% by weight finished fair and even all as specified on fair faces of brick work or concrete surfaces all as specified and directed.(WPC shall be measured and paid separately)
M&L applying two coats of cement base paint over coat of alkali resistant primer after preparing newly plastered surfaces all as specified and directed.
M&L cutting groove exc 100mm but n exc 200 mm girth in brick or stone walls and making good the surfaces using PCC 1:2:4 type B0 in CM 1:3 after inserting water proof bituminous membrane complete all as specified and directed.
Disconnecting existing PVC water tanks of capacity exc 250 litres & n. exc 500 litres setting aside (or lowering) for repair work and hoisting , reconnecting, refixng in the same position complete all as specified and as directed.
Disconnecting existing PVC water tanks of capacity exc 500 litres & n. exc 1000 litres setting aside (or lowering) for repair work and hoisting , reconnecting, refining in the same position complete all as specified and as directed.
Dismantling existing PVC water tanks of capacity exc 500 litres & n.exc 1000 litres all as directed and removed from site all as specified and directed. NOTE:-Dismantled water tank shall become the contractors property as per Sch of credit.
Dismantling existing PVC water tanks of capacity exc 250 litres & n.exc 500 litres all as directed and removed from site all as specified and directed. NOTE:-Dismantled water tank shall become the contractors property as per Sch of credit .
S&F 500 litres rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed.
S&F 1000 litres rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed.
Taking up or down steel tubing and connections 15mm bore all as specified and as directed.
Taking up or down steel tubing and connections 20mm bore all as specified and as directed.
Taking up or down steel tubing and connections 25mm bore all as specified and as directed .
Refixing the steel tubing 15mm bore obtained from item No. 28.00 above after, cleaning in new or old position (wall, ceiling, floor etc.) complete all as specified and as directed .
Refixing the steel tubing 20mm bore obtained from item No 29.00 above after cleaning in new or old position (wall, ceiling, floor etc.) complete all as specified and as directed .
Refixing the steel tubing 25mm bore obtained from item No 30.00 above after cleaning in new or old position (wall, ceiling, floor etc.) complete all as specified and as directed.
S&F GI water tubes 15mm bore medium grade with all fittings and fixed complete to walls and ceiling or laid in floors all as specified and as directed.
S&F GI water tubes of bore 20 mm dia tubes medium grade with all fittings and fixed complete to walls and ceiling or laid in floors all as specified and directed.
S&F GI water tubes of bore 25 mm dia tubes medium grade with all fittings and fixed complete to walls and ceiling or laid in floors all as specified and directed.
S&F in repair 20mm dia gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all as specified and directed
S&F in repair 25mm dia gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all as specified and directed
S&F in repair 20mm bore ball brass valve high pressure, with polythene float and fly nut complete ,screwed for iron pipe or brass ferrule and fixed all as specified as directed.
S&F in repair 25mm bore ball brass valve high pressure ,with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed all as specified as directed.
S&F PVC(SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls and taking down old one all as specified and directed
S&F PVC(SWR) bend 110mm bore any radius and taking down old one all as specified and directed
S&F PVC(SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to walls and taking down old one all as specified and directed
S&F PVC(SWR) bend 75mm bore any radius and taking down old one all as specified and directed
M&L for preparation of surfaces thoroughly by cleaning, washing and removing dust, dirt, oil and loose particles and applying water proofing liquid Dr. Fixit Pidicrete URP in two coats as per manufacturer instructions mix with cement and applying two coats of cement base paint complete all as specified and directed
dhanshree enterprises
M/S L M Chourasia
M/s Ashwin Bhange
M/s Prakash R. Verma
Asha Enterprises
Vishwakarma Engineering Works
Meet Road Lines
M/s ABHIMAN HEGDE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .