| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 LAccepted-AOC PULGAON | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹29.3 L+₹1.4 L (5.12%)Rejected-Finance BHAWANI KRUPA GANDHI CHOWK PULGAON | PULGAON | WARDHA | MAHARASHTRA | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹29.9 L+₹2.0 L (7.34%)Rejected-Finance | L3 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | M/S Maa Durga Constructions,Pulgaon L1 | SHUBHAM SALES L3 | M/S JAI BHAWANI CONSTRUCTIONS L2 |
|---|---|---|---|---|---|---|
| 1.00 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard / dense soil complete all as specified and as directed | 40.48 | Sqm | 50 ₹2,024 Lowest | 52 ₹2,104.96 | 65 ₹2,631.2 |
| 2.00 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m complete all as specified and as directed | 30.72 | Cum | 200 ₹6,144 | 210 ₹6,451.2 | 186 ₹5,713.92 Lowest |
| 3.00 | Add to item No. 03009A for each additional 1.5 m or part thereof in depth beyond the first 1.5 m complete all as specified and as directed | 12.29 | Cum | 225 ₹2,765.25 | 225 ₹2,765.25 | 200 ₹2,458 Lowest |
| 4.00 | M & L for 100mm thick Cement concrete in foundations, filling and mass concret type D2 1:4:8(40mm graded aggregate) complete all as specified and as directed | 2.05 | Cum | 7,500 ₹15,375 Lowest | 9,350 ₹19,167.5 | 8,000 ₹16,400 |
| 5.00 | M &L for RCC M-25 (Design Mix) concrete in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed | 6.3 | Cum | 7,500 ₹47,250 Lowest | 9,250 ₹58,275 | 8,500 ₹53,550 |
| 6.00 | M & L for RCC M-25(Design Mix) concrete in Columns, pillars, piers, posts and struts complete all as specified and as directed | 4.39 | Cum | 7,500 ₹32,925 Lowest | 9,500 ₹41,705 | 8,500 ₹37,315 |
| 7.00 | M & L for RCC M-25 (Design Mix) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed | 2.52 | Cum | 7,500 ₹18,900 Lowest | 9,750 ₹24,570 | 8,500 ₹21,420 |
| 8.00 | M & L for RCC M-25(Desisgn Mix) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed | 2.08 | Cum | 7,500 ₹15,600 Lowest | 9,750 ₹20,280 | 8,500 ₹17,680 |
| 9.00 | M& L for RCC M-25 (Design Mix) in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and as directed | 15.39 | Cum | 7,500 ₹1,15,425 Lowest | 9,000 ₹1,38,510 | 8,750 ₹1,34,662.5 |
| 10.00 | Use and waste of Formwork to sides of rough finished surfaces of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed | 8.4 | Sqm | 300 ₹2,520 Lowest | 415 ₹3,486 | 350 ₹2,940 |
Tender Value
Refer Docs
EMD Value
₹55,820
Closing Date
4 Aug 2025, 6:00 pmClosed
GE PULGAON
GE PULGAON CAD PULGAON 442303
SPL REPAIRS TO UG CABLE OF ESD FIRE STATION, CSD FIRE STATION AT DEPOT AREA, PROVN OF RED GATE NEAR RAE SUB DEPOT AND PROVN OF 50 X EXHAUST FAN FOR FAMILY QUARTER IN RA AT CAD PULGAON
2025_MES_718232_1
8244/PUL/E8
Open Tender
Civil Works
Item Rate
180 days
GE PULGAON
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE PULGAON
₹55,820
Yes
8 Oct 2025
3 Jul 2025
11 Aug 2025
3 Jul 2025
4 Aug 2025
17 Jul 2025
3 Jul 2025 - 16 Jul 2025
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard / dense soil complete all as specified and as directed
Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m complete all as specified and as directed
Add to item No. 03009A for each additional 1.5 m or part thereof in depth beyond the first 1.5 m complete all as specified and as directed
M & L for 100mm thick Cement concrete in foundations, filling and mass concret type D2 1:4:8(40mm graded aggregate) complete all as specified and as directed
M &L for RCC M-25 (Design Mix) concrete in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed
M & L for RCC M-25(Design Mix) concrete in Columns, pillars, piers, posts and struts complete all as specified and as directed
M & L for RCC M-25 (Design Mix) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed
M & L for RCC M-25(Desisgn Mix) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed
M& L for RCC M-25 (Design Mix) in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and as directed
Use and waste of Formwork to sides of rough finished surfaces of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed
Use and waste of Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed
Use and waste of Formwork to sides of pillars, posts, struts, piers, circular columns and stanchions complete all as specified and as directed
Use and waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed
Use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.complete all as specified and as directed
Use and waste of Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all as specified and as directed
Use and waste of Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and as directed
M &L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 complete all as specified and as directed
M &L for Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:4 on circular surfacescomplete all as specified and as directed
M &L for Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:4 on ceiling complete all as specified and as directed
M &L for Rendering 20mm thick on fair faces of brick work or concrete surfaces in CM 1:4 on wall complete all as specified and as directed
M & L for Forming square grooves in plaster n exc 12mm deep and n exc 15mm on face complete all as specified and as directed
M & L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed
M & L for Mild steel TMT bars but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed
Brickwork with Old size bricks fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and as directed
M &L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 complete all as specified and as directed
Material & Labour for preparation of new plastered sufaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and as directed
Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and as directed
Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering
M&L for hardcore of guage n exc 63mm deposited spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface broken stone or boulders all as specified as directed.
75 mm thick Plain Cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in sub base for flooring all as specified as directed.
40 mm thick Plain Cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in flooring including finishing the surface even and smooth with using extra cement all as specified as directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point of any soil all as specified as directed.
Taking out LT XLPE/PVC insulated armoured cable alongwith all joints of any size from trenches wall/roof including taking out of brick layer and sand from trenches complete all as directed by Engr-in-Chrage.
Excavation in trenches by mechnical means (hydraulic excavator) not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out all kind of soil complete all as specified and as directed by EIC..
Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and directed Engr-in-Chrage.
Supply & laying in repair galvanized steel tubing "light grade" with all fittings in trenches/ under roads/ along pole/ wall for cable protection all as specified & directed by Engr-in-Chrage. for the 40mm bore sizes : - .
All as per item No 37 above but 50 mm bore
All as per item No 37 above but size 80 mm bore
Supply and fixing Double wall Corrugated High Density Polymer Ethylene (HDPE) pipe of 50 mm sizes as per IS 14930 (Part-2):2001, Laid in trenches/floors and fixed on walls/poles, with and including neccessary fittings such as bends, sockets and other connected accessories etc., for laying of electric cables, complete all as specified and as directed.
All as per item No 40 above but size 90 mm diameter
Supply, laying and testing LT XLPE insuated PVC bedded galvanised steel strip or wire armoured earthed electric power cable with aluminium conductor 1100 volts grade, heavy duty in trenches/along pole or wall of 16 Sqmm 2 core sizes complete all as specified and directed by Engineer-in-Charges. Note:- 1. Excavation and earth work, HDPE pipes, and cable joint shall be measured and paid separetely under respective items :-
All as per item No 42 abobe but size 70 Sqmm x 3.5 core
Road cutting for UG cable under road/railway crossing, pavement, hardstanding by mannually means, protection GI pipe for cable of required dai and making it good to match with the adjoining surface/structure for after cable passing complete all as specified and directed. Note : GI pipe and PCC will be measured and paid against respective items.
Material and Labour for drilling boring horizontally (Mechanical) through path/ road/ culverts for laying cable complete all as specified and directed by EIC
Material and Labour for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation of pole upto ground level complete all as directed by Engr-in-Chrage.
Material and labour RCC Cable Route indicator showing "MES HT/LT U/G 11/1.1KV" made out of RCC block of size 900 mm height x 300 mm x 300 mm out of 900 mm ,300 mm , 300 will be inside the ground. The RCC block shall be reinforced with 8 mm dia TMT bar at both ways at four faces @ 100 mm c/c . The latters shall be written with red colour synthetic enmel paint all as specifed an as directed. Note :- Quoted rate shall be deemed to included the cost of PCC , excavation, returning, filling and removal of excavated earth upto a distance of not exceeding 30 mtr complete.
PCC (1:3:6) type C-1 using 20 mm graded stone aggregate as in coping/plinth block including necessary form work all as directed by Engr-in-Chrage.
Material and labour in replacement/repair for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 32mm X 6mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (2009) connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt alround earth plate, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) 50mm thick cover reinforced with 8mm dia TMT bars @ 100mm c/c both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm bore GI medium grade earth lead protection pipe, complete all as specified and directed. Note :- Earth strip 32x6 mm and protection pipe 40 mm dia up to 7.5 mtr shall be included in quoted rate.
S&F for GI earthing strip 32x6 mm with nut and bolts complete including taking down old one all as specified and directed by Engr-In Charge
Supply install, testing and commissioning Out door, in replacement of LT Distribution Panel Feeder Pillar (CPRI approved) Cubicle type,IP-56,outdoor type confirming to IS: 61439 Part I & II factory fabricated made out of outer cover with 3 mm thick CRCA sheet & inner cover with 2mm thick CRCA sheet of suitable size to accommodate all accessories / fittings, compartmentalized in costruction to accommodate the incoming MCCB and TPN bus bars and outgoing MCCBs feeders. The TPN busbars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator at an interval of not more than 500 mm through out the length of the TPN bus bar. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables. The cubicle shall have a bottom and four legs (400mm long) of size 50x 50x6 mm, The panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, and fixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, with double door shutter and shall have louvers and airvent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following all as specified and directed by EIC. Note :- PCC work will be included in quoted rates. Note : The panel manufacturer should have following Govt. Approved Certificates: 1. Panel should be according to IEC-61439. CPRI Certification Degree of Protection IP-54 (IS/IEC : 61439 (Part-1), 2011 & IS/IEC : 61439 (Part-2) 2011) 2. Tempreature Rise (IS/IEC : 61439-1, 2011 & IS/IEC : 61439-2 2011) 3. CPRI Short Circuit IEC-61439-1 & 2 withstand strenght should be 70kArms for 1.0 Sec with intial peak of 154kApk 4. CPRI Certification IEC-61439-1 & 2 Rated current for short circuit not less than 6300 A with rated insulation voltage 660V .5. ISO 9001 CERTIFIED . (1) Incoming: (i) Aluminium busbar, 4 Pole, 100 Amps (ii) On Load Change over 63A, 415V = 01 No. (iii) MCCB 4P, 63A, 16 KA, with Integrated Earth Leakage Protection and thermal magnetic: O/L & S/C protection , ICS= 100% ICU = 01 No. (v) Digital Multifunction Meter :-Voltage, current, PF, kWh, frequency MAKE: SECURE / L&T - 01 Set. (v) SPD (Type 2) 3-phase, 20-40kA) - 01 No. (vi ) Samrt Indicating Lamp LED type 240 V 50 HZ AC supply (Cat Part No : SZRILXX24240 Shakti or euivalent BCH/SIEMENS/L&T) set of three colour (RYB)-01 set. (vii) Street Light Timer single phase -01 Nos Outgoing :- (i)MCB 3P, 63A, 25 KA, with thermal magnetic: O/L & S/C protection , ICS= 100% ICU = 01 Nos. (ii) MCB 3P, 32A, 10 KA, with thermal magnetic: O/L & S/C protection , ICS= 100% ICU = 02 Nos. (iii) MCB DP, 32A, 10 KA, with thermal magnetic: O/L & S/C protection , ICS= 100% ICU = 01 Nos.
Material and labour for point wiring complete with 1.5 sqmm single core sheathed PVC insulated FRLSH cable 1100V grade multistraned copper conductor of code red,blue and yellow for phase,black for neutral and green for earth of ISI marked drawn through and including PVC casing caping/surface conduit of suitable size with accessories ISI marked on wall/ceiling including PVC insulated copper cable FRLS 1100V grade multi stranded for earth continuity conductor of same type and size and connected to earth dolly including provision of MODULAR boxes of suitable MODULAR boxes,cover plate for mounting switches/sockets and regulators complete all as specified and as directed. One Ceiling fan/Exhaust fan point controlled by one switch one way
M&L Modular switch one way, 6 Amps, 240V complete all as a specified and directed.
S&F ceiling rose surface baketite three terminals complete all as specified and directed.
Supply and fix exhaust fan steel body AC single phase 230 volts of size 300 mm sweep with blades and frame and louvers complete all as specified and directed including necessary arrangement in wall i.e.making holes if required or making frame for fixing the exhaust fan in kitchen including making hole, connection with 1.5 sqmm FRLSH cable from near ceiling rose.
M/S JAI BHAWANI CONSTRUCTIONS (BID ID -3382319)
SHUBHAM SALES (BID ID -3382047)
Bidder Name
M/S Maa Durga Constructions,Pulgaon
M/S JAI BHAWANI CONSTRUCTIONS
SHUBHAM SALES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .