Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹13.5 L+₹2,459 (0.18%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹14.4 L+₹89,356 (6.63%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹15.5 L+₹2.0 L (15.2%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹16.2 L+₹2.7 L (20.2%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
29 Nov 2023, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
REPAIRS REPLACEMENT OF DAMAGED SEWAGE LINE CLEANING OF SEWAGE LINE SEPTIC TANK MANHOLES DRAINS FENCING GATE BOUNDARY WALL FOOTPATH AT TECH AREA TAKU AND PERIODICAL SERVICES OF CERTAIN BLDGS AND COMPOUND WALLS AT ADM AREA AT CPE ITARSI UNDER GE BHOPAL
2023_MES_626714_1
8225/E8
Open Tender
Civil Works
Item Rate
183 days
ITARSI
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE BHOPAL
₹50,000
Yes
15 Mar 2024
3 Nov 2023
1 Dec 2023
3 Nov 2023
29 Nov 2023
17 Nov 2023
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
M&L for preparation of old plastered or unplastered surfaces of walls including brooming down or steel wire brushing, scrapping down smoke soot, mouldes, moss and efflorescent salts and trading oil and greasy spots and applying one coat of white wash on wall complete all as specified and directed.
All as per ser item No. 1.00 here-in-before but for one coat of white wash on ceilling.
M&L for complete removal of old existing tratment on plastered surface of wall including washing down, rubbing and prepration for one coat oil bound distemper over and including 1mm thick JK Birla wall care putty to make the surface even and smooth complete all as specified and directed.
M&L for complete removal of all existing treatment including preparation of old surface and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004. Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silcon additives @ 1.43litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm all as specified and directed.
Taking down cement or cement lime plaster of any description from brick/stone/concrete surfaces including raking out joints, hacking for keys, scrubbing down with water complete all as specified and directed.
M&L for 15mm thick cement plaster in cement mortar 1:4 of any faces of brick or concrete surfaces finished the surfaces fair and even complete all as specified and directed.
M&L for 10mm thick cement plaster in cement mortar 1:3 on ceiling surfaces fair and even complete all as specified and directed.
M&L for preparation of surface and applying two coats distemper with oil emulsion white or tinted over 2mm thick wall care putty on new plastered surface of wall complete all as specified and directed.
M&L for applying two coats of white wash on newly plastered surfaces of ceiling including preparation of surfaces complete all as specified and directed.
M&L for 15mm thick cement plaster in cement mortar 1:4 mixed with water proofing compound @3% by weight of cement on any faces of brick or concrete surfaces, chajja, cornices externally including dubbing coat if required and finished the surfaces even and smooth without using extra cement complete all as specified and directed. Note : (a) WPC shall be measured and paid separately.
Supply only integral water proofing compound complete all as specified and directed.
M&L for two coats of applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004. Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) wiht silcon additives @ 1.43litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm over new surfaces complete all as specified and directed
M&L for one coat of synthetic enamel paint on old painted wooden surfaces of any description over 10cm width or girth including preparation of old painted wooden surfaces complete all as specified and directed.
All as per item No. 13.00 here-in-before but on steel surfaces complete.
M&L for one coat of alluminium paint on steel or any type of surfaces of any description over 10cm width or girth including preparation of old surfaces complete all as specified and directed.
M&L for writing letters or figures (block, roman, italic or indian) with synthetic enamel paint not exceeding 30cm height complete all as specified and directed.
M&L for cutting out cracks to "V" section in existing roof, terracing and brick wall, RCC beam, ceiling including cleaning out, wetting and grouting with cement and sand slurry 1:3 complete all as specified and directed.
M&L for cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, chajjas, cills, steps, seismic and other similar bands, beams, plinth courses, string courses, lacings courses, parapets and railings upto 60cm in height, copings kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering slightly rounded or chamfered angles and throating including use of necessary formwork complete all as specified and directed.
M&L for attending /cleanig daily complaints of blockage of floor traps, WCs (Indian/European) WHB traps, kitchen traps, urinal traps etc at ground floor or above ground floors with and including necessary T&P as required complete all as specified and directed:- Note :- (a) If any complaint not resolved within 24 hrs the recovery @ Rs 250 per complaint per day will be charged from RAR or Final Bill. (b) During cleaning of blockage, removed grating will be refixed in existing position with white/grey cement after clearing of blockage from trapes. (c) The contractor will ensure the cleaning /cleaning of all the complaints (Irrespective of Nos) within 24 hrs by deploying additional sewer man /safaiwala if needed. Nothing extra charge will be paid on this account. (d) Contractor shall be solely responsible for supplying all the safety measures required by the sewer man/safaiwala during working hours. (e) All the waste material/sludge shall be disposed of out of MoD land.
Taking out RCC cover slab of septic tank of the 100 users capacity carefully, taking out the sludge including foul water, collect the sludge in closed container and burried the same in earth pit below 30 cm of the gound level with in the defence land where directed to a distance exc 250 m and n.exc 500 m, returning, filling in the earth in excavated pit after complete removal of sludge from the container, inlet and outlet pipe, mild steel ring and septic tank, complete cleaning with fresh water as directed and placing the RCC cover slab in position and set in CM 1:6 complete all as specified and directed.
All as per ser item no 20.00 here-in-before but septic tank 50 users capacity complete.
All as per ser item no 20.00 here-in-before but septic tank 25 users capacity complete.
All as per ser item no 20.00 here-in-before but man holes of any size depth n. exc 60 cm complete.
All as per ser item no 20.00 here-in-before but man holes of any size depth exc 60 cm and n.exc 1.20 mtr complete.
All as per ser item no 20.00 here-in-before but man holes of any size depth exc 1.20 mtr complete.
M&L for dewatering/desludging of existing main sewage receiving tank of size 6.0 m dia and 5m deep (inner tank and outer tank) by sewage sunction machine truck mounted equipped with sewage storage tank and dispose off foul material/sludge out side the defence land on the location enmarked by civil authorities complete all as specified and directed.
M&L for dewatering/desludding from existing soakage well by sewage suction machine truck mounting equipped with sewage storage tank and removing/dispose off foul material/sludge out side the defence land on the location enmarked by civil authorities complete all as specified and directed for the following sizes:-
(a) size 2.4 M dia X 3.0M deep
(b) size 1.8 M dia X 3.0M deep
(c) size 1.2 M dia X 3.0M deep
M&L for loose filling with aggregate of guage 80 mm to 150 mm as in soak well /sokage pits /filter beds with broken bricks including removed old brick beds complete all as specified and as directed.
M&L for cleaning of chocked sewage line of any description and any dia from manhole to manhole with sewage cleaning rod washing down with fresh water and disposed off the sludge complete all as specified and directed. Note:-The complaint where cleaning is not possible by rodding and is to be cleared by breaking existing line the item will be paid separetely.
M&L for cleaning of underground sewage lines of 150mm bore by excavation and breaking (minimum two length) and removing the blockage, laying new pipes, re-joining with old pipes including haunching the new pipes with PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) in all situations where cleaning is not possible otherwise including returning, filling and disposal of surplus soil outside MoD land etc. complete all as specified and directed.
Demolition of PCC in ground floors and paving not exc 15cm thickness (below or above ground level) complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in pavement/plinth protection, plinth protection shall be laid in alternate bays and joints shall be filled with bitumastic gola with 80/25 bitumen (1 part bitumen mixed with 3 part of sand) surface finished fair and even complete all as specified and directed.
Demolition of reinforced cement concrete of any description as in man hole / septic tank cover slabs in any position complete all as specified and directed.
M&L for precast reinforced cement concrete type B1, (1:2:4) with using (20 mm graded stone aggregate) as in manhole / soak well cover slab set in CM 1:4 complete all as specified and directed.
M&L for RCC type B-1 (1:2:4) using 20 mm graded stone aggregate as in slabs in septic tank cover slab set in CM 1:4 complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (horizontal or sloping) complete all as specified and directed.
M&L for cement plaster 10 mm thick in cement mortar 1:4 on concrete surface such as soffits of RCC, cover slab, chajja, roof projection columns and beams etc finished even and smooth without using extra cement complete all as specified and directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wires (annealed) not less than 0.9 mm dia or secured with clips complete all as specified and directed.
M&L for mild steel bars 6 to 8mm dia, cut to length bent ot shape required including craking, benindg spirally for hooping ends and binding with and including mild seel wire (annealed) not less than 0.9mm dia securing with clips complete all as specified and directed.
M&L for deformed TMT bars 5 mm dia and over upto and including 10mm dia in stirrups , spacers and binders etc complete all as specified & directed.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m deep and getting out in soft/loose soil for foundation etc, complete all as specified and directed.
Returning filling in, including spreading, leveling watering well roaming in layers not exc. 25 Cm thick each layer complete all as specified and directed.
Removal of surplus soil to a distance of exc. 50 meter and n.exc 250m depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and directed.
Dismantling of SGSW drain pipes/NP-2 pipe of any bore jointed in cement mortar of any size and description including concrete bed and packing/ haunching of any type complete all as specified and directed.
M&L for salt-glazed stone ware drain pipes of internal diameter of pipe in 150 mm laid in trenches and jointed complete all as specified and directed.
M&L for 200 mm dia RCC pipes with collars, class NP-2 laid in trenches and jointed with cement mortar and tested complete all as specified and directed.
M&L for concrete bed to drain pipe including packing under haunching against the side of pipes, 150mm, in cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) after laying and testing of pipe complete all as specified and directed.
M&L for concrete bed to drain pipe including packing under haunching against the side of pipes, 200 mm bore, in cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) after laying and testing of pipe complete all as specified and directed.
S&F of 100 mm dia, cast iron soil waste and vent pipes (sand cast pipe), in any length with or without ears, with cement joints, fixed to wall/floor etc including demolition of existing pipe complete all as specified and directed.
S&F of 75mm dia, cast iron soil waste and vent pipes (sand cast pipe), in any length with or without ears, with cement joints, fixed to wall/floor etc complete all as specified and directed.
S&F in repairs vitreous china squtting pan "ORISSA PATTERN" size 580x440mm white with integral foot rest and flush type complete all as specified and directed.
S&F in repairs vitreous china EWC 'P' or 'S' trap, white including plastic water closet seat cover, white closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device suitable for EWC including making good to floor fixing bolt complete all as specified and directed.
Dismantling floor hearh or, wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for non-skid coloured ceramic edge cut tiles 7-8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but n.exc 0.11sqm as in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles over and including screed bed 15mm thick in cement mortar (1:4) for laying floor finished complete all as specified and directed.
M&L for glazed ceramic coloured tiles size of tiles 450x300x7mm thick on vertical surface such as skirting, dados and risers to steps etc set and jointed in neat cement slurry and pointed in colour cement to match including 10mm thick cement plaster with cement mortar 1:4 complete all as specified and directed.
S&F of 100 mm dia cast iron bend complete all as specified and directed.
S&F of 100 mm dia cast iron branch pieces (equal or unequal) or double parallel branches complete all as specified and directed.
S&F of 100 mm dia cast iron socket (double coller) complete all as specified and directed.
S&F of 110 mm dia PVC(SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and directed.
S&F of 110 mm dia PVC (SWR), bend with access door complete all as specified and directed.
S&F of 110 mm dia PVC (SWR) bend without access door complete all as specified and directed.
S&F PVC (SWR) junction single 110 mm bore, (single T) equal or unequal with access door complete all as specified and as directed.
S&F PVC (SWR) 110 mm bore vent cowl complete all as specified and as directed.
S&F PVC (SWR) pipes 75 mm dia, single socketed, in any length with rubber ring joints, fixed to wall including demolation of existing pipe complete all as specified and as directed.
S&F PVC (SWR) bend 75 mm dia with access door complete all as specified and as directed.
S&F PVC (SWR) bend 75 mm dia without access door complete all as specified and as directed.
S&F PVC (SWR) 75 mm bore vent cowl complete all as specified and as directed.
S&F cast iron floor trap 100 mm dia with gratings includings jointing to waste pipe fixed in cement concrete type B-1 1:2:4 complete all as specified and as directed.
S&F cast iron floor trap 75mm dia with gratings includings jointing to waste pipe fixed in cement concrete type B-1 1:2:4 complete all as specified and as directed.
S&F PVC (SWR) gully trap, 125/110mm,setting and jointing with solvent cement concrete type B-1 1:2:4 complete all as specified and as directed.
S&F CI vent pipe 100mm dia with or without ears with cement joints laid in wall complete all as specified and as directed.
S&F CI cowls 100mm dia complete all as specified and as directed.
S&F CI Branch pipes100 (equal or unequal) with parellel branches
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete.
Material and labour for providing cement concrete 1:4:8, type D2 (40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
Material and labour for providing cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) for surface channel and drain complete all as specified and as directed.
M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete.
M&L for providing cement concrete type B1 1:2:4 (20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed
Demolition of brick work built in cement mortar or lime mortar complete all as specified and as directed.
M&L for brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in 1:4 complete all as specified and as directed
M&L for brick work with sub class 'B' bricks built in CM (1:6) straight or curved on plan exc 6m mean radius complete all as specified and directed.
All as per item 76.00 here-in-before but except sub class 'B' bricks.
M&L for Brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
Material and labour for Brickwork with sub class ‘B’ bricks in one brick thick honey comb walling, built in CM 1:4 as in soak well complete all as specified and directed.
Taking down cement plaster of any description on brick walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
Material and labour for rendering 15mm thick in cement mortar (1:4) on fair faces of brickwork or concrete surfaces, finished the surfaces even and smooth without using extra cement complete all as specified and as directed.
Material and labour for rendering 15mm thick in cement mortar (1:6) on fair faces of brickwork or concrete surfaces, finished the surface even and smooth without using extra cement complete all as specified and as directed.
Supply only intregal water proofing compound
M&L for two coats of cement base paint on newly plastered surfaces of wall including preparation of surfaces over one coat of alkali resistant primer all as specified and directed
M&L for two coats of white wash on newly plastered surfaces of wall including preparation of surfaces all as specified and directed
M&L for 100mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in pavement, hardstanding, path, plinth protection shall be laid in alternate bays and joints shall be filled with bitumastic gola with 80/25 bitumen (1 part bitumen and 3 parts sand), finished the surface fair and even complete all as specified and as directed.
M&L 75mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in subbase of flooring complete all as specified and directed.
M&L 20mm thick screed bed in CM (1:6) as in sub base of floor complete all as specified and directed.
M&L chequered cement concrete tiles pre polished lacuqer and glossy finish 30cmx30cmx25mm thick, set ,jointed and pointed in neat cement slurry with grey cement and pigment in floors.complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not other wise provided complete all as specified and as directed.
S&F for framed work of rolled mild steel conforming to Fe-410-W (Gde-E-250) quality-A as in doors or gates of angle or other section with gusset plates, rails, braces, etc, drilled for fixing of steel sheeting or other covering; doors etc to be prepared for hanging or sliding with and including either hooks & hinges or steel hanging door fittings (exclusive of steel sheeting, running rails & guides) and hanging, fastening & fixing complete.
Supply and fix rolled mild steel Fe-410-w (grade E-250) quality A framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work complete all as specified and as directed.
Dismantling of old chain link fencing including flat iron, line wire complete all as specified and as directed.
Dismantling posts or struts (wood, steel or RCC), any section, including taking out embedded portion and making good disturbed ground; posts embedded in concrete, brick work, masonry, etc complete.
Excavation in post holes (or similar holes) each n exc 0.5cum, getting out hard/dense soil and returning , filling in and ramming earth or broken rubble mixed with earth with around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exc 50m and making good surface
M&L for PCC (1:3:6) type C2 40 mm graded aggregate in foundation and mass concrete complete all as specified and directed.
S&F Mild steel work conforming to Fe-290-0 GdeE-165 complete, in nosing to steps including embeding in concrete and screwing etc, wind ties for roof including securing bolts, posts & struts in fencing including cutting top to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc complete.
Supply only GI chain link fencing of any size and any type, straining bolts & fixed to angle iron post complete all as specified.
S&F mild steel bolts screw (Machine made) wth hexagonal or square head at one end and screw the other or screw both ends, each screwed ends to be fitted with washer and one hexagonal or square length of nut exceeding 5cm and not exceedigng 10cm and diameter of neck in mm 11 to 15mm complete all as specified and directed
Fixing only chain link fencing wire including line wire any mesh, size and shape of standard, rails, rails, straining bolts incl winding wire complete
S&F for mild steel, 10mm dia TMT bar Fe-410-w (grade E-250) quality as line wire for holding chain link mesh complete all as specified and as directed.
Supply and fixing galvanized, 2 strand steel barbed wire 2.24mm dia barbard with 2mm dia barbs at 75 mm spacing straing and fixing to any type of standerd rairs strainig bolts, including and tying at crossing with and provision of galvnized mild wire, staples or steel pins etc.complete all as specified and directed.( including distmantling of unservisable barberdd wire) (Each line of wire to be measured).
M&L for preparing new or previously untreated steel & iron surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over & including a coat of red oxide primer complete.
M&L for two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces of any description n.exc. 10cm width or girth including preparation of new surfaces complete all as specified and directed.
Deduct Schedule of credit (calculation will be done off line) Rs. 14680.00
MANISH INDUSTRIES
TANUJ CONST. CO.
pyarelal galar
PK CONSULTANT
M/S HARSH VIKAS GALAR ENGINEERING
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .