Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.1 CrAccepted-AOC C 246 RIICO COLONY ABU ROAD DISTT SIROHI | ABU ROAD | SIROHI | RAJASTHAN | ₹12.1 Cr | L1 | Accepted-AOC OK |
| 2 | L2₹12.3 CrRejected-AOC OPP PANCHYAT SAMITTI STATION ROAD BHINMAL DISTT JALORE | BHINMAL | JALORE | RAJASTHAN | ₹12.3 Cr | L2 | Rejected-AOC OK |
| 3 | L3₹12.4 CrRejected-AOC 112 AMBALA ROAD NARAINGARH AMBALA 134203 | NARAINGARH | AMBALA | HARYANA | 134203 | ₹12.4 Cr | L3 | Rejected-AOC OK |
Updated dates
Tender Value
₹15.0 Cr
EMD Value
₹29.9 L
Closing Date
16 Feb 2026, 12:00 pmClosed
Addl. Chief Engineer PWD Zone I jodhpur
Addl. Chief Engineer PWD Zone I jodhpur
Construction and maintenance of Rural roads under PMGSY-IV, Batch-I, 2025-26, Package No. RJ29P4-13 (District Sirohi)
2026_CERJ_146319_1
RJ29P4-13
Open Tender
Civil Works - Roads
330 days
Sirohi
Please refer Tender documents.
7 documents required · 7 mandatory
₹15,000
₹29.9 L
Addl. Chief Engineer PWD Zone I jodhpur
11 Apr 2026
18 Jan 2026
16 Feb 2026
19 Jan 2026
16 Feb 2026
19 Jan 2026
29 Jan 2026
(1) MRL01- Padar To Katarwadi Construction of reference bench mark (1 No.), working bench mark (4 Nos.) and near all drainage structures and bridges (as per direction of Engineer-in-charge), reference pillar/ burgees @ 50m interval on both side of formation width including marking of centre line, setting out curves, recording of levels, white washing and lettering etc. complete as per MORD specifications cl. 108. Reference pillars / Burjees as per drawing No. 200.2 of MoRD specifications including the cost of material required for construction. Height upto 1.00 m from GL Reference benchmark/working benchmark (As per drawing annex-I) (BT+CC)
Clearing Grass and Removal of Rubbish Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per MoRD Specification Clause 201.By Mechanical Means In area of non-thorny jungle
Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 m Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per MoRD Specification Clause 302.3
Construction of Embankment with Material Obtained from Roadway Cutting Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per MoRD Specification Clause 301.5
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per MoRD Specification Clause 303.1.
Construction of granular sub-base by providing well graded crusher borken material, mixing in a mechanical mix plant at OMC , carriage of mixed material to work site upto lead of 1000m spreading in uniform layers with Tractor Mount Grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per MoRD Specification Clause 401. For Grading I Material
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening & binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per MoRD Specification Clause 405. . Using Crusher Broken Aggregate By Manual Means
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per MoRD Specification Clause 405. using Crusher borken aggregateBy Manual Means
Construction of granular sub-base by providing well graded material, spreading in uniform layers with Tractor Mount Grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per MoRD Specification Clause 401. For Grading III Material For Grading Ill Material
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per MoRD Specification Clause 502. Low porosity
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per MoRD Specification Clause 503.
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using Viscosity grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per MoRD Specification Clause 506 & for modified Bitumen Clause 511.Case -II By mechnical means.Bitumen VG-30
Add extra for adding Shreaded Plastic Waste as per Guidelines envisaged in IRC:SP:98-2013 over Item No. 5.9, 5.11 & 16.23 of Bitumenous Surface Course @ 8% of the quantity of Bitumen by weight including mixing of aggregate and plastic waste in Hot Mix Plant( The Bitumen content will be as per respective Clause of MoRD Specifications)
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per MoRD Specification Clause 508 & modified Bitumen Clause 511 By Mechanical Means Type B Bitumen(VG-30)
Construction of Foundation / Inaugration Pedastal in 23 cm thick Brick masonry in CM 1:4 of size 1.20m x 1.80m above ground level with adequate foundation including providing and fixing of Granite stone of size 0.75m x0.60m with engraving letters and figures,cement plaster,white washing etc. complete as per direction of Engineer in charge.
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1 of MoRTH Specification, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.
Construction of panel concrete pavement M-40 grade for Thin White Topping (Thickness greater than I00 mm and less than 200 mm) Construction of short paneled un reinforced, plain cement concrete pavement (Thin white Topping as per IRC : SP: 76-2015) :M-40 grade concrete over a prepared sub base or over bituminous surface (Existing bituminous surface prepared if necessary either by milling or leveling course to be done with BM / DBM / DLC to correct surface profile and to be paid separately) with Ordinary Portland Cement 53 grade confirming to IS:12269, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 31.5 mm , mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixture as approved, curing of concrete slabs for 14 days, using curing compound (where specified) and water including vaccum dewatering process with all required equipments, finishing to lines and grade as per drawing and MoRD specification Clause 1501 complete excluding cost of steel in dowel bars and tie bars etc. Each Panel (1.00m x 1.00m). Note : If fiber are to be used as per mix design the same shall be paid separately as per item no 6.8
Earthwork in excavation for structures as per drawing and MoRD specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.Ordinary soil.Upto 3 m depth
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRD specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 15 Nominal mix (1:2.5:5)
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRD specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix (1:2.5:5)
Stone masonry work in cement mortar in foundation complete as per drawing and MoRD specifications Clauses 702, 704, 1202 & 1203 In 1:4 cement mortar
Providing and laying reinforced cement concrete in superstructure as per drawing and MoRD specifications Clauses 800, 1401.2 and 1401.4.For height upto 5 m.R.C.C M 25.
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and MoRD specifications Clauses 1001 and 1401
Providing and fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing and MoRD specifications 1403.4
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRD specification Clauses 1206.6
Backfilling behind abutment, wing wall and return wall complete as per drawings & MoRD specification Clause 1206.3.Granular Material
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and MoRD specifications Clauses 800, 900 and 1404.3.3
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and MoRD Specification Clause 1701
Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing less than 25 kg laid dry complete as per drawing and MoRD specifications Clause 1301
Plastering with cement mortar (1:4), 20 mm thick on Stone work.
Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and MoRD specification Clauses 615, 710 and 1204.3.11 50 mm thick
Pointing with cement mortar (1:3) on Stone work as per drawing and MoRD specification Clauses 613.3 and 1204 Flush and Rulled Type
Retro-Reflective Traffic signs up to 0.90 sqm size board Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.3.8 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and MoRD Specification Clause 170 .A 900 mm equilateral & triangle
Retro-Reflective Traffic signs up to 0.90 sqm size board Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.3.8 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and MoRD Specification Clause 170 B 600 mm Circular
Providing and Fixing informatory sign board with Logo of PMGSY Project Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three plates of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7. The top most plate will be in diamond shape of 600mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25mm x 5 mm size on back on edges. The middle plate will be 1200 mm x 150 mm size riveted over welded M.S. angle iron frame of 25mm x 25mm x 5 mm size on back on edges. The main lower most plate will be 1500 mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25 mm x 5 mm size. Welding of all the sheets over angle iron frame will be done neatly to have plain surface on one side. The angle iron frames of the lower most plate and the middle plate will be welded to two nos. 75 mm x 75 mm (12 SWG) sheet tubes posts placed at 1125 mm apart centre to centre. The top of the middle plate will be flushed with the top of 75 mm dia medium steel tube posts and these posts will be embedded in cement concrete M15 grade blocks of 450 mm x 450 mm x 600 mm below ground level. The height of bottom of the lower most plate will be 1200 mm from normal ground level and the bottom of middle plate will be 100 mm above the top level of the lower most plate. The lettering and borders, etc. of middle and bottom plate, PMGSY logo on top plate shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing. For warranty and durability the clause 1701.5 and for maintenance the clause 1911 shall be applicable. A reference number along with the month and year of installation should be placed on the back of a sign in a contrasting colour or by stamping in characters not exceeding 50 mm in height as per approved drawing and MoRD Specification Clause 1700
Providing and fixing of PMGSY logo with definition plate (as per MORD design/drawing) 3mm thick plate of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7. The top most plate will be in diamond shape of 600mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25mm x 5 mm size on back on edges including orange luminous colour epoxy paint on logo, size of definition plate 900x300mm supported on MS post of square hollow section 75x75x6mm, 3m long .The lettering and borders, etc. of definition plate and PMGSY logo on top plate shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing.Posts will be fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and MoRD Specification Clause 1700
Direction and Place Identification signs with size more than 0.9 sqm size board Providing and erecting direction and place identification retro-\reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.3.8, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and MoRD Specification Clause 1701
Providing and fixing of typical " PMGSY Citizen Information Board Providing and Erecting typical Citizen's information Board as per approved drawing & specification of MORD made of Two plates of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7 of size 900 mm x 750 mm size riveted over welded M.S. angle iron frame of 25mm x 25mm x 5 mm size on back on edges. Frame will be welded to two nos. 75 mm x 75 mm (12 SWG) sheet tubes posts placed at 1000 mm apart centre to centre these posts will be embedded in cement concrete M15 grade blocks of 450 mm x 450 mm x 600 mm below ground level. The lettering and borders, etc. of plates shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing and MoRD Specification Clause 1700
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and MoRD Specification Clause 1703 5th Kilometre Stone (precast)
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and MoRD Specification Clause 1703 Ordinary Kilometer Stone (Precast)
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and MoRD Specification Clause 1703 200 m stone (precast)
Cut Stone boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704
Providing and laying rounded hump type speed breakers for crossing speed 25 km/h as per IRC design including providing and applying bitumen emulsion tack coat, making speed breaker in designed profile with bituminous macadam, providing seal coat type B for sealing the voids and marking chequered pattern with thermoplastic paint complete as per IRC : 99-1988 3.70 meter wide and 10 cm high for general traffic
Marking Centre Line and stop lines etc. on road as per IRC pattern with thermoplastic paint of approved quality and make with 8% glass beads laid on the road surface at temperature 160" C with a special applicator machine complete with a special applicator machine complete with labour material and traffic diversion arrangements.
Providing and Erecting typical Maintenance information Board as per approved drawing & specification of MORD made of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7 of size 900mm x 1500mm stiffend by angle iron 25mmx25mm x 3mm all around the plate & plates fixed on frame of two nos. 75 mm x 75 mm (12 SWG) sheet tubes posts placed at 1000 mm apart centre to centre (vertical post 3050 mm with angle holdfasts and horizontal member 900mm) to be joined by embedded in cement concrete M15 grade blocks of 450 mm x 450 mm x 600 mm below ground level. The lettering and borders, etc. of plates shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing and MoRD Specification Clause 1700
P & F Delinator with 30 cm. outer dia RCC hume pipe NP-2 (As per IS-458/ 1971 ) pipe 1. OM. Long 40 cm embedded in cement concrete (1:4:8) block of size 50x50x40 cm. including excavation upto 40 cm depth. The inside of pipe shall be filled with C.C. (1:4:8) stone grit max size 20 mm or less upto the top with semi circular humping. The pipes shall be painted white/black with enamel paint with red dots two Nos. on each side
Supply of Hazard Marker made out of 2 mm thick M.S. sheet size 300x300x3 mm framed with angle iron 25x25x3 mm and fixed on channel posts 75x40x6 mm and hold fast at bottom whole body is painted in white stoving enamel and 6 Nos., 5 cm dia reflective sheet on white reflective background with additional border of 1.25 cm all arount it.
Supply & Fixing of Chevron sign of size 75x60 cm made out of aluminum sheet 2 mm thick with fixing provision on M.S. angle iron post 50x50x6 mm 3 M long screwed with stainless steel nut bolts of 8mm dia, plate is covered by high intensity grade yellow retro-reflective sheeting and black screen printed arrow on Retro Reflective Sheet, complete in all respect. Comp. in all respect duly post painted in alternate band of Black/White synthetic enamel paint & hold fast at bottom
Supplying of Cat’s Eye made of ABS Material having high reflective reflectors molded in PMMA material are fitted on the Stud. The reflectors are welded with a ABS base plate through ultrasonic welding process.
(2) MRL02- Bhatana To Pawti Construction of reference bench mark (1 No.), working bench mark (4 Nos.) and near all drainage structures and bridges (as per direction of Engineer-in-charge), reference pillar/ burgees @ 50m interval on both side of formation width including marking of centre line, setting out curves, recording of levels, white washing and lettering etc. complete as per MORD specifications cl. 108. Reference pillars / Burjees as per drawing No. 200.2 of MoRD specifications including the cost of material required for construction. Height upto 1.00 m from GL Reference benchmark/working benchmark (As per drawing annex-I) (BT+CC)
Clearing Grass and Removal of Rubbish Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per MoRD Specification Clause 201.By Mechanical Means In area of non-thorny jungle
Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 m Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per MoRD Specification Clause 302.3
Construction of Embankment with Material Obtained from Roadway Cutting Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per MoRD Specification Clause 301.5
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per MoRD Specification Clause 303.1.
Construction of granular sub-base by providing well graded crusher borken material, mixing in a mechanical mix plant at OMC , carriage of mixed material to work site upto lead of 1000m spreading in uniform layers with Tractor Mount Grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per MoRD Specification Clause 401. For Grading I Material
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening & binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per MoRD Specification Clause 405. . Using Crusher Broken Aggregate By Manual Means
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per MoRD Specification Clause 405. using Crusher borken aggregateBy Manual Means
Construction of granular sub-base by providing well graded material, spreading in uniform layers with Tractor Mount Grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per MoRD Specification Clause 401. For Grading III Material For Grading Ill Material
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per MoRD Specification Clause 502. Low porosity
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per MoRD Specification Clause 503.
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using Viscosity grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per MoRD Specification Clause 506 & for modified Bitumen Clause 511.Case -II By mechnical means.Bitumen VG-30
Add extra for adding Shreaded Plastic Waste as per Guidelines envisaged in IRC:SP:98-2013 over Item No. 5.9, 5.11 & 16.23 of Bitumenous Surface Course @ 8% of the quantity of Bitumen by weight including mixing of aggregate and plastic waste in Hot Mix Plant( The Bitumen content will be as per respective Clause of MoRD Specifications)
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per MoRD Specification Clause 508 & modified Bitumen Clause 511 By Mechanical Means Type B Bitumen(VG-30)
Construction of Foundation / Inaugration Pedastal in 23 cm thick Brick masonry in CM 1:4 of size 1.20m x 1.80m above ground level with adequate foundation including providing and fixing of Granite stone of size 0.75m x0.60m with engraving letters and figures,cement plaster,white washing etc. complete as per direction of Engineer in charge.
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1 of MoRTH Specification, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.
Construction of panel concrete pavement M-40 grade for Thin White Topping (Thickness greater than I00 mm and less than 200 mm) Construction of short paneled un reinforced, plain cement concrete pavement (Thin white Topping as per IRC : SP: 76-2015) :M-40 grade concrete over a prepared sub base or over bituminous surface (Existing bituminous surface prepared if necessary either by milling or leveling course to be done with BM / DBM / DLC to correct surface profile and to be paid separately) with Ordinary Portland Cement 53 grade confirming to IS:12269, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 31.5 mm , mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixture as approved, curing of concrete slabs for 14 days, using curing compound (where specified) and water including vaccum dewatering process with all required equipments, finishing to lines and grade as per drawing and MoRD specification Clause 1501 complete excluding cost of steel in dowel bars and tie bars etc. Each Panel (1.00m x 1.00m). Note : If fiber are to be used as per mix design the same shall be paid separately as per item no 6.8
Earthwork in excavation for structures as per drawing and MoRD specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.Ordinary soil.Upto 3 m depth
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRD specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 15 Nominal mix (1:2.5:5)
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRD specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix (1:3:6)
Stone masonry work in cement mortar in foundation complete as per drawing and MoRD specifications Clauses 702, 704, 1202 & 1203 In 1:4 cement mortar
Providing and laying reinforced cement concrete in superstructure as per drawing and MoRD specifications Clauses 800, 1401.2 and 1401.4.For height upto 5 m.R.C.C M 25.
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and MoRD specifications Clauses 1001 and 1401
Providing and fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing and MoRD specifications 1403.4
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRD specification Clauses 1206.6
Backfilling behind abutment, wing wall and return wall complete as per drawings & MoRD specification Clause 1206.3.Granular Material
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and MoRD specifications Clauses 800, 900 and 1404.3.3
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and MoRD Specification Clause 1701
Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing less than 25 kg laid dry complete as per drawing and MoRD specifications Clause 1301
Plastering with cement mortar (1:4), 20 mm thick on Stone work.
Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and MoRD specification Clauses 615, 710 and 1204.3.11 50 mm thick
Pointing with cement mortar (1:3) on Stone work as per drawing and MoRD specification Clauses 613.3 and 1204 Flush and Rulled Type
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.1200mm dia.
Retro-Reflective Traffic signs up to 0.90 sqm size board Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.3.8 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and MoRD Specification Clause 170 .A 900 mm equilateral & triangle
Retro-Reflective Traffic signs up to 0.90 sqm size board Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.3.8 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and MoRD Specification Clause 170 B 600 mm Circular
Providing and Fixing informatory sign board with Logo of PMGSY Project Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three plates of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7. The top most plate will be in diamond shape of 600mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25mm x 5 mm size on back on edges. The middle plate will be 1200 mm x 150 mm size riveted over welded M.S. angle iron frame of 25mm x 25mm x 5 mm size on back on edges. The main lower most plate will be 1500 mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25 mm x 5 mm size. Welding of all the sheets over angle iron frame will be done neatly to have plain surface on one side. The angle iron frames of the lower most plate and the middle plate will be welded to two nos. 75 mm x 75 mm (12 SWG) sheet tubes posts placed at 1125 mm apart centre to centre. The top of the middle plate will be flushed with the top of 75 mm dia medium steel tube posts and these posts will be embedded in cement concrete M15 grade blocks of 450 mm x 450 mm x 600 mm below ground level. The height of bottom of the lower most plate will be 1200 mm from normal ground level and the bottom of middle plate will be 100 mm above the top level of the lower most plate. The lettering and borders, etc. of middle and bottom plate, PMGSY logo on top plate shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing. For warranty and durability the clause 1701.5 and for maintenance the clause 1911 shall be applicable. A reference number along with the month and year of installation should be placed on the back of a sign in a contrasting colour or by stamping in characters not exceeding 50 mm in height as per approved drawing and MoRD Specification Clause 1700
Providing and fixing of PMGSY logo with definition plate (as per MORD design/drawing) 3mm thick plate of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7. The top most plate will be in diamond shape of 600mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25mm x 5 mm size on back on edges including orange luminous colour epoxy paint on logo, size of definition plate 900x300mm supported on MS post of square hollow section 75x75x6mm, 3m long .The lettering and borders, etc. of definition plate and PMGSY logo on top plate shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing.Posts will be fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and MoRD Specification Clause 1700
Direction and Place Identification signs with size more than 0.9 sqm size board Providing and erecting direction and place identification retro-\reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.3.8, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and MoRD Specification Clause 1701
Providing and fixing of typical " PMGSY Citizen Information Board Providing and Erecting typical Citizen's information Board as per approved drawing & specification of MORD made of Two plates of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7 of size 900 mm x 750 mm size riveted over welded M.S. angle iron frame of 25mm x 25mm x 5 mm size on back on edges. Frame will be welded to two nos. 75 mm x 75 mm (12 SWG) sheet tubes posts placed at 1000 mm apart centre to centre these posts will be embedded in cement concrete M15 grade blocks of 450 mm x 450 mm x 600 mm below ground level. The lettering and borders, etc. of plates shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing and MoRD Specification Clause 1700
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and MoRD Specification Clause 1703 5th Kilometre Stone (precast)
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and MoRD Specification Clause 1703 Ordinary Kilometer Stone (Precast)
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and MoRD Specification Clause 1703 200 m stone (precast)
Cut Stone boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704
Providing and laying rounded hump type speed breakers for crossing speed 25 km/h as per IRC design including providing and applying bitumen emulsion tack coat, making speed breaker in designed profile with bituminous macadam, providing seal coat type B for sealing the voids and marking chequered pattern with thermoplastic paint complete as per IRC : 99-1988 3.70 meter wide and 10 cm high for general traffic
Marking Centre Line and stop lines etc. on road as per IRC pattern with thermoplastic paint of approved quality and make with 8% glass beads laid on the road surface at temperature 160" C with a special applicator machine complete with a special applicator machine complete with labour material and traffic diversion arrangements.
Providing and Erecting typical Maintenance information Board as per approved drawing & specification of MORD made of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7 of size 900mm x 1500mm stiffend by angle iron 25mmx25mm x 3mm all around the plate & plates fixed on frame of two nos. 75 mm x 75 mm (12 SWG) sheet tubes posts placed at 1000 mm apart centre to centre (vertical post 3050 mm with angle holdfasts and horizontal member 900mm) to be joined by embedded in cement concrete M15 grade blocks of 450 mm x 450 mm x 600 mm below ground level. The lettering and borders, etc. of plates shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing and MoRD Specification Clause 1700
P & F Delinator with 30 cm. outer dia RCC hume pipe NP-2 (As per IS-458/ 1971 ) pipe 1. OM. Long 40 cm embedded in cement concrete (1:4:8) block of size 50x50x40 cm. including excavation upto 40 cm depth. The inside of pipe shall be filled with C.C. (1:4:8) stone grit max size 20 mm or less upto the top with semi circular humping. The pipes shall be painted white/black with enamel paint with red dots two Nos. on each side
Supply of Hazard Marker made out of 2 mm thick M.S. sheet size 300x300x3 mm framed with angle iron 25x25x3 mm and fixed on channel posts 75x40x6 mm and hold fast at bottom whole body is painted in white stoving enamel and 6 Nos., 5 cm dia reflective sheet on white reflective background with additional border of 1.25 cm all arount it.
Supplying of Cat’s Eye made of ABS Material having high reflective reflectors molded in PMMA material are fitted on the Stud. The reflectors are welded with a ABS base plate through ultrasonic welding process.
(3) MRL03- Bhatana To Kamboiyakheda Construction of reference bench mark (1 No.), working bench mark (4 Nos.) and near all drainage structures and bridges (as per direction of Engineer-in-charge), reference pillar/ burgees @ 50m interval on both side of formation width including marking of centre line, setting out curves, recording of levels, white washing and lettering etc. complete as per MORD specifications cl. 108. Reference pillars / Burjees as per drawing No. 200.2 of MoRD specifications including the cost of material required for construction. Height upto 1.00 m from GL Reference benchmark/working benchmark (As per drawing annex-I) (BT+CC)
Clearing Grass and Removal of Rubbish Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per MoRD Specification Clause 201.By Mechanical Means In area of non-thorny jungle
Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 m Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per MoRD Specification Clause 302.3
Construction of Embankment with Material Obtained from Roadway Cutting Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per MoRD Specification Clause 301.5
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per MoRD Specification Clause 303.1.
Construction of granular sub-base by providing well graded crusher borken material, mixing in a mechanical mix plant at OMC , carriage of mixed material to work site upto lead of 1000m spreading in uniform layers with Tractor Mount Grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per MoRD Specification Clause 401. For Grading I Material
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening & binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per MoRD Specification Clause 405. . Using Crusher Broken Aggregate By Manual Means
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per MoRD Specification Clause 405. using Crusher borken aggregateBy Manual Means
Construction of granular sub-base by providing well graded material, spreading in uniform layers with Tractor Mount Grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per MoRD Specification Clause 401. For Grading III Material For Grading Ill Material
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per MoRD Specification Clause 502. Low porosity
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per MoRD Specification Clause 503.
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using Viscosity grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per MoRD Specification Clause 506 & for modified Bitumen Clause 511.Case -II By mechnical means.Bitumen VG-30
Add extra for adding Shreaded Plastic Waste as per Guidelines envisaged in IRC:SP:98-2013 over Item No. 5.9, 5.11 & 16.23 of Bitumenous Surface Course @ 8% of the quantity of Bitumen by weight including mixing of aggregate and plastic waste in Hot Mix Plant( The Bitumen content will be as per respective Clause of MoRD Specifications)
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per MoRD Specification Clause 508 & modified Bitumen Clause 511 By Mechanical Means Type B Bitumen(VG-30)
Construction of Foundation / Inaugration Pedastal in 23 cm thick Brick masonry in CM 1:4 of size 1.20m x 1.80m above ground level with adequate foundation including providing and fixing of Granite stone of size 0.75m x0.60m with engraving letters and figures,cement plaster,white washing etc. complete as per direction of Engineer in charge.
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1 of MoRTH Specification, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.
Construction of panel concrete pavement M-40 grade for Thin White Topping (Thickness greater than I00 mm and less than 200 mm) Construction of short paneled un reinforced, plain cement concrete pavement (Thin white Topping as per IRC : SP: 76-2015) :M-40 grade concrete over a prepared sub base or over bituminous surface (Existing bituminous surface prepared if necessary either by milling or leveling course to be done with BM / DBM / DLC to correct surface profile and to be paid separately) with Ordinary Portland Cement 53 grade confirming to IS:12269, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 31.5 mm , mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixture as approved, curing of concrete slabs for 14 days, using curing compound (where specified) and water including vaccum dewatering process with all required equipments, finishing to lines and grade as per drawing and MoRD specification Clause 1501 complete excluding cost of steel in dowel bars and tie bars etc. Each Panel (1.00m x 1.00m). Note : If fiber are to be used as per mix design the same shall be paid separately as per item no 6.8
Earthwork in excavation for structures as per drawing and MoRD specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.Ordinary soil.Upto 3 m depth
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRD specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 15 Nominal mix (1:2.5:5)
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRD specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix (1:2.5:5)
Stone masonry work in cement mortar in foundation complete as per drawing and MoRD specifications Clauses 702, 704, 1202 & 1203 In 1:4 cement mortar
Providing and laying reinforced cement concrete in superstructure as per drawing and MoRD specifications Clauses 800, 1401.2 and 1401.4.For height upto 5 m.R.C.C M 25.
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and MoRD specifications Clauses 1001 and 1401
Providing and fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing and MoRD specifications 1403.4
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRD specification Clauses 1206.6
Backfilling behind abutment, wing wall and return wall complete as per drawings & MoRD specification Clause 1206.3.Granular Material
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and MoRD specifications Clauses 800, 900 and 1404.3.3
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and MoRD Specification Clause 1701
Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing less than 25 kg laid dry complete as per drawing and MoRD specifications Clause 1301
Plastering with cement mortar (1:4), 20 mm thick on Stone work.
Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and MoRD specification Clauses 615, 710 and 1204.3.11 50 mm thick
Pointing with cement mortar (1:3) on Stone work as per drawing and MoRD specification Clauses 613.3 and 1204 Flush and Rulled Type
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.1200mm dia.
Retro-Reflective Traffic signs up to 0.90 sqm size board Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.3.8 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and MoRD Specification Clause 170 .A 900 mm equilateral & triangle
Retro-Reflective Traffic signs up to 0.90 sqm size board Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.3.8 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and MoRD Specification Clause 170 B 600 mm Circular
Providing and Fixing informatory sign board with Logo of PMGSY Project Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three plates of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7. The top most plate will be in diamond shape of 600mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25mm x 5 mm size on back on edges. The middle plate will be 1200 mm x 150 mm size riveted over welded M.S. angle iron frame of 25mm x 25mm x 5 mm size on back on edges. The main lower most plate will be 1500 mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25 mm x 5 mm size. Welding of all the sheets over angle iron frame will be done neatly to have plain surface on one side. The angle iron frames of the lower most plate and the middle plate will be welded to two nos. 75 mm x 75 mm (12 SWG) sheet tubes posts placed at 1125 mm apart centre to centre. The top of the middle plate will be flushed with the top of 75 mm dia medium steel tube posts and these posts will be embedded in cement concrete M15 grade blocks of 450 mm x 450 mm x 600 mm below ground level. The height of bottom of the lower most plate will be 1200 mm from normal ground level and the bottom of middle plate will be 100 mm above the top level of the lower most plate. The lettering and borders, etc. of middle and bottom plate, PMGSY logo on top plate shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing. For warranty and durability the clause 1701.5 and for maintenance the clause 1911 shall be applicable. A reference number along with the month and year of installation should be placed on the back of a sign in a contrasting colour or by stamping in characters not exceeding 50 mm in height as per approved drawing and MoRD Specification Clause 1700
Providing and fixing of PMGSY logo with definition plate (as per MORD design/drawing) 3mm thick plate of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7. The top most plate will be in diamond shape of 600mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25mm x 5 mm size on back on edges including orange luminous colour epoxy paint on logo, size of definition plate 900x300mm supported on MS post of square hollow section 75x75x6mm, 3m long .The lettering and borders, etc. of definition plate and PMGSY logo on top plate shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing.Posts will be fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and MoRD Specification Clause 1700
Direction and Place Identification signs with size more than 0.9 sqm size board Providing and erecting direction and place identification retro-\reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.3.8, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and MoRD Specification Clause 1701
Providing and fixing of typical " PMGSY Citizen Information Board Providing and Erecting typical Citizen's information Board as per approved drawing & specification of MORD made of Two plates of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7 of size 900 mm x 750 mm size riveted over welded M.S. angle iron frame of 25mm x 25mm x 5 mm size on back on edges. Frame will be welded to two nos. 75 mm x 75 mm (12 SWG) sheet tubes posts placed at 1000 mm apart centre to centre these posts will be embedded in cement concrete M15 grade blocks of 450 mm x 450 mm x 600 mm below ground level. The lettering and borders, etc. of plates shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing and MoRD Specification Clause 1700
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and MoRD Specification Clause 1703 5th Kilometre Stone (precast)
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and MoRD Specification Clause 1703 Ordinary Kilometer Stone (Precast)
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and MoRD Specification Clause 1703 200 m stone (precast)
Cut Stone boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704
Providing and laying rounded hump type speed breakers for crossing speed 25 km/h as per IRC design including providing and applying bitumen emulsion tack coat, making speed breaker in designed profile with bituminous macadam, providing seal coat type B for sealing the voids and marking chequered pattern with thermoplastic paint complete as per IRC : 99-1988 3.70 meter wide and 10 cm high for general traffic
Marking Centre Line and stop lines etc. on road as per IRC pattern with thermoplastic paint of approved quality and make with 8% glass beads laid on the road surface at temperature 160" C with a special applicator machine complete with a special applicator machine complete with labour material and traffic diversion arrangements.
Providing and Erecting typical Maintenance information Board as per approved drawing & specification of MORD made of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7 of size 900mm x 1500mm stiffend by angle iron 25mmx25mm x 3mm all around the plate & plates fixed on frame of two nos. 75 mm x 75 mm (12 SWG) sheet tubes posts placed at 1000 mm apart centre to centre (vertical post 3050 mm with angle holdfasts and horizontal member 900mm) to be joined by embedded in cement concrete M15 grade blocks of 450 mm x 450 mm x 600 mm below ground level. The lettering and borders, etc. of plates shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing and MoRD Specification Clause 1700
P & F Delinator with 30 cm. outer dia RCC hume pipe NP-2 (As per IS-458/ 1971 ) pipe 1. OM. Long 40 cm embedded in cement concrete (1:4:8) block of size 50x50x40 cm. including excavation upto 40 cm depth. The inside of pipe shall be filled with C.C. (1:4:8) stone grit max size 20 mm or less upto the top with semi circular humping. The pipes shall be painted white/black with enamel paint with red dots two Nos. on each side
Supply of Hazard Marker made out of 2 mm thick M.S. sheet size 300x300x3 mm framed with angle iron 25x25x3 mm and fixed on channel posts 75x40x6 mm and hold fast at bottom whole body is painted in white stoving enamel and 6 Nos., 5 cm dia reflective sheet on white reflective background with additional border of 1.25 cm all arount it.
Supplying of Cat’s Eye made of ABS Material having high reflective reflectors molded in PMMA material are fitted on the Stud. The reflectors are welded with a ABS base plate through ultrasonic welding process.
(5) MRL04- AR To Lalpura Construction of reference bench mark (1 No.), working bench mark (4 Nos.) and near all drainage structures and bridges (as per direction of Engineer-in-charge), reference pillar/ burgees @ 50m interval on both side of formation width including marking of centre line, setting out curves, recording of levels, white washing and lettering etc. complete as per MORD specifications cl. 108. Reference pillars / Burjees as per drawing No. 200.2 of MoRD specifications including the cost of material required for construction. Height upto 1.00 m from GL Reference benchmark/working benchmark (As per drawing annex-I) (BT+CC)
Clearing Grass and Removal of Rubbish Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per MoRD Specification Clause 201.By Mechanical Means In area of non-thorny jungle
Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 m Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per MoRD Specification Clause 302.3
Construction of Embankment with Material Obtained from Roadway Cutting Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per MoRD Specification Clause 301.5
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per MoRD Specification Clause 303.1.
Construction of granular sub-base by providing well graded crusher borken material, mixing in a mechanical mix plant at OMC , carriage of mixed material to work site upto lead of 1000m spreading in uniform layers with Tractor Mount Grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per MoRD Specification Clause 401. For Grading I Material
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening & binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per MoRD Specification Clause 405. . Using Crusher Broken Aggregate By Manual Means
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per MoRD Specification Clause 405. using Crusher borken aggregateBy Manual Means
Construction of granular sub-base by providing well graded material, spreading in uniform layers with Tractor Mount Grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per MoRD Specification Clause 401. For Grading III Material For Grading Ill Material
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per MoRD Specification Clause 502. Low porosity
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per MoRD Specification Clause 503.
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using Viscosity grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per MoRD Specification Clause 506 & for modified Bitumen Clause 511.Case -II By mechnical means.Bitumen VG-30
Add extra for adding Shreaded Plastic Waste as per Guidelines envisaged in IRC:SP:98-2013 over Item No. 5.9, 5.11 & 16.23 of Bitumenous Surface Course @ 8% of the quantity of Bitumen by weight including mixing of aggregate and plastic waste in Hot Mix Plant( The Bitumen content will be as per respective Clause of MoRD Specifications)
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per MoRD Specification Clause 508 & modified Bitumen Clause 511 By Mechanical Means Type B Bitumen(VG-30)
Construction of Foundation / Inaugration Pedastal in 23 cm thick Brick masonry in CM 1:4 of size 1.20m x 1.80m above ground level with adequate foundation including providing and fixing of Granite stone of size 0.75m x0.60m with engraving letters and figures,cement plaster,white washing etc. complete as per direction of Engineer in charge.
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1 of MoRTH Specification, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.
Construction of panel concrete pavement M-40 grade for Thin White Topping (Thickness greater than I00 mm and less than 200 mm) Construction of short paneled un reinforced, plain cement concrete pavement (Thin white Topping as per IRC : SP: 76-2015) :M-40 grade concrete over a prepared sub base or over bituminous surface (Existing bituminous surface prepared if necessary either by milling or leveling course to be done with BM / DBM / DLC to correct surface profile and to be paid separately) with Ordinary Portland Cement 53 grade confirming to IS:12269, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 31.5 mm , mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixture as approved, curing of concrete slabs for 14 days, using curing compound (where specified) and water including vaccum dewatering process with all required equipments, finishing to lines and grade as per drawing and MoRD specification Clause 1501 complete excluding cost of steel in dowel bars and tie bars etc. Each Panel (1.00m x 1.00m). Note : If fiber are to be used as per mix design the same shall be paid separately as per item no 6.8
Earthwork in excavation for structures as per drawing and MoRD specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.Ordinary soil.Upto 3 m depth
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRD specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 15 Nominal mix (1:2.5:5)
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRD specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix (1:3:6)
Stone masonry work in cement mortar in foundation complete as per drawing and MoRD specifications Clauses 702, 704, 1202 & 1203 In 1:4 cement mortar
Providing and laying reinforced cement concrete in superstructure as per drawing and MoRD specifications Clauses 800, 1401.2 and 1401.4.For height upto 5 m.R.C.C M 25.
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and MoRD specifications Clauses 1001 and 1401
Providing and fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing and MoRD specifications 1403.4
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRD specification Clauses 1206.6
Backfilling behind abutment, wing wall and return wall complete as per drawings & MoRD specification Clause 1206.3.Granular Material Material
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and MoRD specifications Clauses 800, 900 and 1404.3.3
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and MoRD Specification Clause 1701
Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing less than 25 kg laid dry complete as per drawing and MoRD specifications Clause 1301
Plastering with cement mortar (1:4), 20 mm thick on Stone work.
Construction of un-reinforced, without dowel bar, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days, using curing compound and water finishing to lines and grade as per drawing and MoRD Specification Clause 1501 including vaccum dewatering process with all required equipments
Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and MoRD specification Clauses 615, 710 and 1204.3.11 50 mm thick
Pointing with cement mortar (1:3) on Stone work as per drawing and MoRD specification Clauses 613.3 and 1204 Flush and Rulled Type
Retro-Reflective Traffic signs up to 0.90 sqm size board Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.3.8 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and MoRD Specification Clause 170 .A 900 mm equilateral & triangle
Retro-Reflective Traffic signs up to 0.90 sqm size board Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.3.8 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and MoRD Specification Clause 170 B 600 mm Circular
Providing and Fixing informatory sign board with Logo of PMGSY Project Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three plates of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7. The top most plate will be in diamond shape of 600mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25mm x 5 mm size on back on edges. The middle plate will be 1200 mm x 150 mm size riveted over welded M.S. angle iron frame of 25mm x 25mm x 5 mm size on back on edges. The main lower most plate will be 1500 mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25 mm x 5 mm size. Welding of all the sheets over angle iron frame will be done neatly to have plain surface on one side. The angle iron frames of the lower most plate and the middle plate will be welded to two nos. 75 mm x 75 mm (12 SWG) sheet tubes posts placed at 1125 mm apart centre to centre. The top of the middle plate will be flushed with the top of 75 mm dia medium steel tube posts and these posts will be embedded in cement concrete M15 grade blocks of 450 mm x 450 mm x 600 mm below ground level. The height of bottom of the lower most plate will be 1200 mm from normal ground level and the bottom of middle plate will be 100 mm above the top level of the lower most plate. The lettering and borders, etc. of middle and bottom plate, PMGSY logo on top plate shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing. For warranty and durability the clause 1701.5 and for maintenance the clause 1911 shall be applicable. A reference number along with the month and year of installation should be placed on the back of a sign in a contrasting colour or by stamping in characters not exceeding 50 mm in height as per approved drawing and MoRD Specification Clause 1700
Providing and fixing of PMGSY logo with definition plate (as per MORD design/drawing) 3mm thick plate of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7. The top most plate will be in diamond shape of 600mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25mm x 5 mm size on back on edges including orange luminous colour epoxy paint on logo, size of definition plate 900x300mm supported on MS post of square hollow section 75x75x6mm, 3m long .The lettering and borders, etc. of definition plate and PMGSY logo on top plate shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing.Posts will be fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and MoRD Specification Clause 1700
Direction and Place Identification signs with size more than 0.9 sqm size board Providing and erecting direction and place identification retro-\reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.3.8, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and MoRD Specification Clause 1701
Providing and fixing of typical " PMGSY Citizen Information Board Providing and Erecting typical Citizen's information Board as per approved drawing & specification of MORD made of Two plates of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7 of size 900 mm x 750 mm size riveted over welded M.S. angle iron frame of 25mm x 25mm x 5 mm size on back on edges. Frame will be welded to two nos. 75 mm x 75 mm (12 SWG) sheet tubes posts placed at 1000 mm apart centre to centre these posts will be embedded in cement concrete M15 grade blocks of 450 mm x 450 mm x 600 mm below ground level. The lettering and borders, etc. of plates shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing and MoRD Specification Clause 1700
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and MoRD Specification Clause 1703 5th Kilometre Stone (precast)
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and MoRD Specification Clause 1703 Ordinary Kilometer Stone (Precast)
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and MoRD Specification Clause 1703 200 m stone (precast)
Cut Stone boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704
Providing and laying rounded hump type speed breakers for crossing speed 25 km/h as per IRC design including providing and applying bitumen emulsion tack coat, making speed breaker in designed profile with bituminous macadam, providing seal coat type B for sealing the voids and marking chequered pattern with thermoplastic paint complete as per IRC : 99-1988 3.70 meter wide and 10 cm high for general traffic
Marking Centre Line and stop lines etc. on road as per IRC pattern with thermoplastic paint of approved quality and make with 8% glass beads laid on the road surface at temperature 160" C with a special applicator machine complete with a special applicator machine complete with labour material and traffic diversion arrangements.
Providing and Erecting typical Maintenance information Board as per approved drawing & specification of MORD made of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7 of size 900mm x 1500mm stiffend by angle iron 25mmx25mm x 3mm all around the plate & plates fixed on frame of two nos. 75 mm x 75 mm (12 SWG) sheet tubes posts placed at 1000 mm apart centre to centre (vertical post 3050 mm with angle holdfasts and horizontal member 900mm) to be joined by embedded in cement concrete M15 grade blocks of 450 mm x 450 mm x 600 mm below ground level. The lettering and borders, etc. of plates shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing and MoRD Specification Clause 1700
P & F Delinator with 30 cm. outer dia RCC hume pipe NP-2 (As per IS-458/ 1971 ) pipe 1. OM. Long 40 cm embedded in cement concrete (1:4:8) block of size 50x50x40 cm. including excavation upto 40 cm depth. The inside of pipe shall be filled with C.C. (1:4:8) stone grit max size 20 mm or less upto the top with semi circular humping. The pipes shall be painted white/black with enamel paint with red dots two Nos. on each side
Supply of Hazard Marker made out of 2 mm thick M.S. sheet size 300x300x3 mm framed with angle iron 25x25x3 mm and fixed on channel posts 75x40x6 mm and hold fast at bottom whole body is painted in white stoving enamel and 6 Nos., 5 cm dia reflective sheet on white reflective background with additional border of 1.25 cm all arount it.
Supplying of Cat’s Eye made of ABS Material having high reflective reflectors molded in PMMA material are fitted on the Stud. The reflectors are welded with a ABS base plate through ultrasonic welding process.
(6) MRL07-AR To Vidmiya .Construction of reference bench mark (1 No.), working bench mark (4 Nos.) and near all drainage structures and bridges (as per direction of Engineer-in-charge), reference pillar/ burgees @ 50m interval on both side of formation width including marking of centre line, setting out curves, recording of levels, white washing and lettering etc. complete as per MORD specifications cl. 108. Reference pillars / Burjees as per drawing No. 200.2 of MoRD specifications including the cost of material required for construction. Height upto 1.00 m from GL Reference benchmark/working benchmark (As per drawing annex-I) (BT+CC)
Clearing Grass and Removal of Rubbish Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per MoRD Specification Clause 201.By Mechanical Means In area of non-thorny jungle
Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 m Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per MoRD Specification Clause 302.3
Construction of Embankment with Material Obtained from Roadway Cutting Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per MoRD Specification Clause 301.5
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per MoRD Specification Clause 303.1.
Construction of granular sub-base by providing well graded crusher borken material, mixing in a mechanical mix plant at OMC , carriage of mixed material to work site upto lead of 1000m spreading in uniform layers with Tractor Mount Grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per MoRD Specification Clause 401. For Grading I Material
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening & binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per MoRD Specification Clause 405. . Using Crusher Broken Aggregate By Manual Means
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per MoRD Specification Clause 405. using Crusher borken aggregateBy Manual Means
Construction of granular sub-base by providing well graded material, spreading in uniform layers with Tractor Mount Grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per MoRD Specification Clause 401. For Grading III Material For Grading Ill Material
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per MoRD Specification Clause 502. Low porosity
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per MoRD Specification Clause 503.
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using Viscosity grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per MoRD Specification Clause 506 & for modified Bitumen Clause 511.Case -II By mechnical means.Bitumen VG-30
Add extra for adding Shreaded Plastic Waste as per Guidelines envisaged in IRC:SP:98-2013 over Item No. 5.9, 5.11 & 16.23 of Bitumenous Surface Course @ 8% of the quantity of Bitumen by weight including mixing of aggregate and plastic waste in Hot Mix Plant( The Bitumen content will be as per respective Clause of MoRD Specifications)
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per MoRD Specification Clause 508 & modified Bitumen Clause 511 By Mechanical Means Type B Bitumen(VG-30)
Construction of Foundation / Inaugration Pedastal in 23 cm thick Brick masonry in CM 1:4 of size 1.20m x 1.80m above ground level with adequate foundation including providing and fixing of Granite stone of size 0.75m x0.60m with engraving letters and figures,cement plaster,white washing etc. complete as per direction of Engineer in charge.
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1 of MoRTH Specification, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.
Construction of panel concrete pavement M-40 grade for Thin White Topping (Thickness greater than I00 mm and less than 200 mm) Construction of short paneled un reinforced, plain cement concrete pavement (Thin white Topping as per IRC : SP: 76-2015) :M-40 grade concrete over a prepared sub base or over bituminous surface (Existing bituminous surface prepared if necessary either by milling or leveling course to be done with BM / DBM / DLC to correct surface profile and to be paid separately) with Ordinary Portland Cement 53 grade confirming to IS:12269, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 31.5 mm , mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixture as approved, curing of concrete slabs for 14 days, using curing compound (where specified) and water including vaccum dewatering process with all required equipments, finishing to lines and grade as per drawing and MoRD specification Clause 1501 complete excluding cost of steel in dowel bars and tie bars etc. Each Panel (1.00m x 1.00m). Note : If fiber are to be used as per mix design the same shall be paid separately as per item no 6.8
Earthwork in excavation for structures as per drawing and MoRD specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.Ordinary soil.Upto 3 m depth
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRD specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 15 Nominal mix (1:2.5:5)
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRD specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix (1:3:6)
Stone masonry work in cement mortar in foundation complete as per drawing and MoRD specifications Clauses 702, 704, 1202 & 1203 In 1:4 cement mortar
Providing and laying reinforced cement concrete in superstructure as per drawing and MoRD specifications Clauses 800, 1401.2 and 1401.4.For height upto 5 m.R.C.C M 25.
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and MoRD specifications Clauses 1001 and 1401
Providing and fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing and MoRD specifications 1403.4
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRD specification Clauses 1206.6
Backfilling behind abutment, wing wall and return wall complete as per drawings & MoRD specification Clause 1206.3.Granular Material
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and MoRD specifications Clauses 800, 900 and 1404.3.3
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and MoRD Specification Clause 1701
Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing less than 25 kg laid dry complete as per drawing and MoRD specifications Clause 1301
Plastering with cement mortar (1:4), 20 mm thick on Stone work.
Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and MoRD specification Clauses 615, 710 and 1204.3.11 50 mm thick
Pointing with cement mortar (1:3) on Stone work as per drawing and MoRD specification Clauses 613.3 and 1204 Flush and Rulled Type
Retro-Reflective Traffic signs up to 0.90 sqm size board Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.3.8 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and MoRD Specification Clause 170A 900 mm equilateral & triangle
Retro-Reflective Traffic signs up to 0.90 sqm size board Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.3.8 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and MoRD Specification Clause 170B 600 mm Circular
Providing and Fixing informatory sign board with Logo of PMGSY Project Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three plates of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7. The top most plate will be in diamond shape of 600mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25mm x 5 mm size on back on edges. The middle plate will be 1200 mm x 150 mm size riveted over welded M.S. angle iron frame of 25mm x 25mm x 5 mm size on back on edges. The main lower most plate will be 1500 mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25 mm x 5 mm size. Welding of all the sheets over angle iron frame will be done neatly to have plain surface on one side. The angle iron frames of the lower most plate and the middle plate will be welded to two nos. 75 mm x 75 mm (12 SWG) sheet tubes posts placed at 1125 mm apart centre to centre. The top of the middle plate will be flushed with the top of 75 mm dia medium steel tube posts and these posts will be embedded in cement concrete M15 grade blocks of 450 mm x 450 mm x 600 mm below ground level. The height of bottom of the lower most plate will be 1200 mm from normal ground level and the bottom of middle plate will be 100 mm above the top level of the lower most plate. The lettering and borders, etc. of middle and bottom plate, PMGSY logo on top plate shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing. For warranty and durability the clause 1701.5 and for maintenance the clause 1911 shall be applicable. A reference number along with the month and year of installation should be placed on the back of a sign in a contrasting colour or by stamping in characters not exceeding 50 mm in height as per approved drawing and MoRD Specification Clause 1700
Providing and fixing of PMGSY logo with definition plate (as per MORD design/drawing) 3mm thick plate of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7. The top most plate will be in diamond shape of 600mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25mm x 5 mm size on back on edges including orange luminous colour epoxy paint on logo, size of definition plate 900x300mm supported on MS post of square hollow section 75x75x6mm, 3m long .The lettering and borders, etc. of definition plate and PMGSY logo on top plate shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing.Posts will be fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and MoRD Specification Clause 1700
Direction and Place Identification signs with size more than 0.9 sqm size board Providing and erecting direction and place identification retro-\reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.3.8, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and MoRD Specification Clause 1701
Providing and fixing of typical " PMGSY Citizen Information Board Providing and Erecting typical Citizen's information Board as per approved drawing & specification of MORD made of Two plates of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7 of size 900 mm x 750 mm size riveted over welded M.S. angle iron frame of 25mm x 25mm x 5 mm size on back on edges. Frame will be welded to two nos. 75 mm x 75 mm (12 SWG) sheet tubes posts placed at 1000 mm apart centre to centre these posts will be embedded in cement concrete M15 grade blocks of 450 mm x 450 mm x 600 mm below ground level. The lettering and borders, etc. of plates shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing and MoRD Specification Clause 1700
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and MoRD Specification Clause 1703 5th Kilometre Stone (precast)
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and MoRD Specification Clause 1703 Ordinary Kilometer Stone (Precast)
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and MoRD Specification Clause 1703 200 m stone (precast)
Cut Stone boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704
Providing and laying rounded hump type speed breakers for crossing speed 25 km/h as per IRC design including providing and applying bitumen emulsion tack coat, making speed breaker in designed profile with bituminous macadam, providing seal coat type B for sealing the voids and marking chequered pattern with thermoplastic paint complete as per IRC : 99-1988 3.70 meter wide and 10 cm high for general traffic
Marking Centre Line and stop lines etc. on road as per IRC pattern with thermoplastic paint of approved quality and make with 8% glass beads laid on the road surface at temperature 160" C with a special applicator machine complete with a special applicator machine complete with labour material and traffic diversion arrangements.
Providing and Erecting typical Maintenance information Board as per approved drawing & specification of MORD made of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7 of size 900mm x 1500mm stiffend by angle iron 25mmx25mm x 3mm all around the plate & plates fixed on frame of two nos. 75 mm x 75 mm (12 SWG) sheet tubes posts placed at 1000 mm apart centre to centre (vertical post 3050 mm with angle holdfasts and horizontal member 900mm) to be joined by embedded in cement concrete M15 grade blocks of 450 mm x 450 mm x 600 mm below ground level. The lettering and borders, etc. of plates shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing and MoRD Specification Clause 1700
P & F Delinator with 30 cm. outer dia RCC hume pipe NP-2 (As per IS-458/ 1971 ) pipe 1. OM. Long 40 cm embedded in cement concrete (1:4:8) block of size 50x50x40 cm. including excavation upto 40 cm depth. The inside of pipe shall be filled with C.C. (1:4:8) stone grit max size 20 mm or less upto the top with semi circular humping. The pipes shall be painted white/black with enamel paint with red dots two Nos. on each side
Supply of Hazard Marker made out of 2 mm thick M.S. sheet size 300x300x3 mm framed with angle iron 25x25x3 mm and fixed on channel posts 75x40x6 mm and hold fast at bottom whole body is painted in white stoving enamel and 6 Nos., 5 cm dia reflective sheet on white reflective background with additional border of 1.25 cm all arount it.
Supply & Fixing of Chevron sign of size 75x60 cm made out of aluminum sheet 2 mm thick with fixing provision on M.S. angle iron post 50x50x6 mm 3 M long screwed with stainless steel nut bolts of 8mm dia, plate is covered by high intensity grade yellow retro-reflective sheeting and black screen printed arrow on Retro Reflective Sheet, complete in all respect. Comp. in all respect duly post painted in alternate band of Black/White synthetic enamel paint & hold fast at bottom
Supplying of Cat’s Eye made of ABS Material having high reflective reflectors molded in PMMA material are fitted on the Stud. The reflectors are welded with a ABS base plate through ultrasonic welding process.
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.1200mm dia.
Add GST (18%) on Total Costruction Cost
Routine Mainteenance work After Completion of works for Five Year Fixed Amount
For 1st Year (0.68%)
For 2nd Year (0.87%)
For 3rd Year (1.12%)
For 4th Year (1.31%)
For 5th Year (1.52%)
Add GST (18%) on Total Maintenance Cost
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
techsummary_226754.pdf
finance_226754.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 4.00 MB
SBD_RJ29P4_13.pdf
Tender Documents • 1.12 MB
BOQ_226754.xls
BOQ • 0.60 MB
online_payment_and_Circular_opt.pdf
Tender Documents • 4.67 MB
Download all tender documents and submit your bid