| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.5 LAccepted-AOC AWADHI ROAD ADAJAN 1ST 102 DABKA NO 1 1 6 4 C 4TH FLOOR | GANDHINAGAR | L1 | Accepted-AOC Lowest | |
| 2 | L2₹50.5 L+₹1.5 L (3.02%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹51.2 L+₹2.1 L (4.35%)Rejected-Finance GP RAM COLONY AMRITSAR JALANDHAR 144103 | AMRITSAR | AMRITSAR | PUNJAB | 144103 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹52.6 L+₹3.5 L (7.20%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest |
Tender Value
Refer Docs
EMD Value
₹99,900
Closing Date
26 Mar 2025, 6:00 pmClosed
Sachin Kumar IDSE EE GE AF Adampur
Military Engineer Services AF Stn Adampur 144103
MISC REPAIR TO CEILING PANELLING AND ROOF SHEETS AND INTERNAL WIRING IN DOMESTIC AREA AT AF STN ADAMPUR
2025_MES_699479_1
GE(AF)/ADM/T-07 OF 2025-26
Open Tender
Civil Works
Item Rate
180 days
Under GE AF Adampur
As per NIT Documents
8 documents required · 8 mandatory
₹500
GE AF Adampur
₹99,900
Yes
26 May 2025
26 Feb 2025
27 Mar 2025
27 Feb 2025
26 Mar 2025
13 Mar 2025
27 Feb 2025 - 12 Mar 2025
Amount
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface in SOFT/LOOSE soil complete all as specified and directed.
M&L for Cement Concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in wall or retaining wall any thickness, size or shape including pilasters, bultresses, columns, pillars and post (including cap and base) etc complete all as specified and directed.
M&L for Cement concrete, type B-0 (1:2:4), using 12.5 mm graded crushed stone aggregates as in lintels up to 1.5 metre clear span, bed blocks, copings and the like including weathering, slightly rounded or chamfered angles & throating including provision of necessary formwork, complete all as specified.
M&L for Brick work using bricks as specified in PS clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified and directed.
M&L for Solid PVC wall lining consisting of 5 mm thick Wood grain colour PVC sheet inclusive of solvent cement and fixing on PVC frame complete all as specified and directed.
M&L for 5 mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC frame, complete all as specified and directed.
M&L for Plywood 6 mm thick, ply type BB commercial BWR confirming to IS: 303 fixed on frame, IN REPAIRS, complete all as shown and directed.
M&L for Teakwood Ply 9 mm thick, ply type BB commercial BWR confirming to IS: 303 fixed on frame, IN REPAIRS, complete all as shown and directed.
M&L for 2nd class hardwood plain fillets square or rectangular in section clean sawn screwed with nails or brads but sec area 13 Sqcm but n exc 25 Sqcm as in framed work complete all as specified and directed.
M&L for Powder coated GI snap grid frame work including suspenders with size of grid 605 mm x 605 mm for false ceiling all as specified and shown on serial page No. 186 of MES Schedule Part-II.
M&L for 6 mm thick asbestos fibre cement building board, cut to size and fixed in grid frame work ceiling as panels, complete all as specified and directed.
S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre, complete all as specified.
S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs / trusses by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
S&F, Gypsum Board 12 mm thick size 600 x 600 mm size fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish, complete all as specified and directed. NOTE: Frame work & hangers for ceiling shall be measured and paid separately)
S&F Mild steel works in hand rails, half round or other stock section or core for wooden handrail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) in-cluding all necessary drilling, bolting or riveting, etc., confirming to Fe-290-Gde E-165, complete all as specified and directed.
S&F Rolled mild steel work as in tubular trusses including special shaped washer etc using ERW or induction butt welded tube conforming to IS 1161-1979 grade St -240 complete all as specified. quality-A complete all as specified and directed
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm of any colour hving tensile strength of 550 Mpa as in roof coverng/cladding to wall, fixed with self tapping screws etc. complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm of any colour hving tensile strength of 550 Mpa as in roof coverng/cladding to wall, fixed with self tapping screws etc. complete all as specified and directed.
M&L for Rendering 5 mm thick on fair faces of concrete surfaces, finished fair and even on ceiling surfaces in cement mortar (1:3), including taking down existing cement plaster complete all as specified and directed.
M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair in cement mortar (1:4), including taking down existing cement plaster complete all as specified and directed.
M&L for Three coats of white wash on new ceiling surfaces, including preparation of surfaces, complete all as specified.
M&L for Prepration of new wall surfaces of any description with mechenical scraper of any description, complete all specified and applying the following: - (a) Applying wall care putty, in two coats & smoothening the surfaces as specified. (preparatory to paint as directed). (b) Two coats of exterior acrylic emulson over and including a coat of water based exterior primer.
M&L for Two coats of synthetic enamel paint over new steel & iron surfaces of any description, not otherwise described, over 10 cm in width or girth, over a coat of red oxide primer for height not exceeding 10 metre including preparation of new surfaces complete all as specified and directed.
Preparation of wooden surface including cleaning with sand paper and applying two coats of french polish to achieve glossy finish and including fillings with putty/ wood filler as required complete all as specified and directed.
E/M WORKS :-
M&L for Point wiring with multi-stranded copper conductor, single core, FRLSH PVC insulated and unsheathed cable, including FRLSH PVC insulated unsheathed stranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes with 3 mm thick plastic laminated sheet cover having necessary cutting for fixing switches/ sockets comprising the following: -
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified and directed.
One light point controlled by two nos. 2-way switches with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specifiedand directed.
One Socket outlet three pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified and directed.
One Socket outlet three pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified and directed.
One socket outlet three pin, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified and directed.
One socket outlet three pin, 6/16 Amp, independent, with 4 Sq. mm (nominal area) cable & 4 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified and directed.
Point wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed FRLSH cable, including PVC insulated unsheathed stranded copper conductor single core FRLSH cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes with base frame & cover plate suitable (for fixing modular switch/sockets) comprising the following: -
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified and directed.
One light point controlled by two nos. 2-way switches with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified and directed.
One Socket outlet, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified and directed.
One Socket outlet, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified and directed.
One socket outlet, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified and directed.
NOTES FOR SERIAL ITEM NOS 26 & 27: (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. (b) GI boxes shall be fixed flush to walls in position with cement mortar (1:4) complete all as directed. (c) Conduit shall be laid on surface in case of RCC ceiling surfaces.
S&F Switch piano flush button single pole one way, 6 Amp complete all as specified and directed.
S&F Switch piano flush button single pole two way, 6 Amp complete all as specified and directed.
S&F Switch piano, bell/buzzer push, flush button single pole one way, 6 Amp complete all as specified and directed.
S&F Switch piano flush button single pole one way, 16 Amp complete all as specified and directed.
S&F Socket outlet multipurpose having provision for 2&3 pin, 6 Amp, flush type, complete all as specified and directed.
S&F Socket outlet multipurpose having provision for two-in-one 3 pin 6 Amp & 3 pin 16 Amp, flush type complete all as specified and directed.
S&F Ceiling rose, surface bakelite, 65 x 50mm, three terminals complete all as specified and directed.
S&F Lamp (angle) holder, insulated body, cord grip pattern, complete all as specified and directed.
S&F Electric buzzer AC 230 volt, single pole, Ding Dong type complete all as specified and directed.
S&F Fan regulator (electronic) suitable for 48”/56” sweep fan, step socket type, single phase, complete all as specified.
S&F Switch modular type single pole one way, 6 Amp, complete all as specified and directed.
S&F Switch modular type single pole two way, 6 Amp, complete all as specified and directed.
S&F Bell push switch modular type single pole one way, 6 Amp, complete all as specified.
S&F Switch modular type single pole one way, 16 Amp,complete all as specified and directed.
S&F Socket outlet modular type multipurpose having provision for 2&3 pin, 6 Amp, complete all as specified and directed.
S&F Socket outlet modular type multipurpose having provision for two-in-one 3 pin 6 Amp & 3 pin 16 Amp, complete all as specified and directed.
S&F Fan regulator modular type (electronic) suitable for 48”/56” sweep fan, step type, two module, complete all as specified and directed..
MAKE FOR SERIAL ITEM 28 TO 44: HAVELLS, LEGRAND or equivalent compatible make mentioned in Appendix 'B'.
S&F Sub main wiring (with approved colour coding as per IS) with single core FRLSH PVC insulated multi stranded copper conductor 1.1 KV grade (main cable: number of runs as indicated below along with single core FRLSH PVC insulated multi stranded copper conductor 1.1 KV grade for earthing in conduits, complete all as specified for the following: -
2 runs of 2.5 Sq. mm main cable + 1 run of 2.5 Sq. mm earth cable
2 runs of 4 Sq. mm main cable + 1 run of 4 Sq. mm earth cable
2 runs of 6 Sq. mm main cable + 1 run of 6 Sq. mm earth cable
NOTES: (i) Conduit & conduit accessories shall be measured & paid for separately. (ii) For payment purposes, total runs of main cable (each run of one running metre) as mentioned above and one run (one running metre) of earth cable shall be considered together as "1 RUNNING METRE"
S&F Rigid non metallic, PVC concealed conduit, 20 mm bore, medium grade, ISI marked, inclusive of all fitings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing acessories such as couplers, lock nuts, saddles, pipe hook etc. for sub main wiring and the like complete all as specified and directed.
S&F Sheet metal enclosure for DB for fixing MCB’s, isolators etc., having IP-43 protection, suitable for surface and flush mounting, complete all as specified comprising the following: -
SPN, 2 way with 200 Amp rated bus bar, 240 V.
SPN, 4 way with 200 Amp rated bus bar, 240 V, double door type.
SPN, 8 way with 200 Amp rated bus bar, 240 V, double door type.
SPN, 12 way with 200 Amp rated bus bar, 240 V, double door type.
TPN, 4 way with 200 Amp rated bus bar, 415 V, double door type
S&F Sheet metal enclosure for DB for fixing MCB’s, isolators etc., having IP-43 protection, VTPN, 4 way with 200 Amp rated bus bar, 415 V, with and including MCCB 4 pole 63 Amp, 16kA., double door type, surface and flush mounting, complete all as specified and directed.
S&F MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp, complete all as specified and directed.
S&F MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6-32 Amp, complete all as specified and directed.
S&F MCB suitable for 415 volt AC supply, TPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 63 Amp, complete all as specified and directed.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 240 volt, breaking capacity not less than 10 kA, complete all as specified and directed.
S&F Envirnment friendly, modern design, energy saving surface mounted, decorative 10 W bulk head LED luminaire with premium quality diffuser fo glarefree light, 6000K, IN REPLACEMENT, complete. MAKE: Havells Cat No. HEXAFT10WLED857SSYMBOPC or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F Surface mounted environment friendly LED batten with powder coated aluminium housing with intigrated electronic driver with THD<10% LED 10W lighting fixture 2 feet long, 6500K, lumen output should not be less than 90 lumens per watt, including making connections, complete all as specified and directed. MAKE: Havells Cat No. ENDURALINEARNEOBS10WLED865SPCWH or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F Surface mounted environment friendly with eye soft technology & glarefree diffuser decorative box type LED 20 W lighting , 6500K, lumen output should not be less than 90 lumens per watt complete. MAKE: Havells Cat No. ENDURALINEARNEOBS20WLED865SPCWH or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F Recess mounted bottom opening LED 36W cool day light luminaire (2x2) CRCA powder coated housing, IP- 54 protection, suitable for grid ceiling lumen output should not be less than 90 lumens per watt complete all as specified and directed. MAKE: Havells Cat No. DROPDOWNFLAT2X2PLR36WLED857 or equivalent in makes mentioned in Appendix 'B' here-in-after.
Supply and Replacing round shape 6W, 220V AC, recessed type with high efficiency PMMA diffuser with soft glare free day light complete with drivers, holders, LED lamps suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and Replacing round shape 12W, 220V AC, recessed type with high efficiency PMMA diffuser with soft glare free day light complete with drivers, holders, LED lamps suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F BLDC Ceiling Fan complete with blades, down rods and accessories 230 V, 1200mm sweep, min air delivery 210 CFM with service valve 6.00 BEE Five star rated with brushless direct current motor complete all as specified and directed.
Collecton of items like ceiling fans, exhaust fans, wall mounted fans, cabin/table fans, flame proof ceiling fans from EM store yard for repair, transporting to workshop, opening and reassembling after including necessary cleaning greasing oiling etc, testing and depositing back to EM store yard of GE (AF) Adampur including necessary loading unloading and transporting etc. complete all as specified and directed. NOTE: Supply only spares & rewinding of fan(s) shall be measured & paid for separately under respective items of BoQ.
M&L for Rewinding fan of any description with super enamelled copper winding wire of size, gauge & weight as per original specifications providing insulating material and varnishing with synthetic varnish, oiling, greasing including replacement of bush/bearing, condenser, 'U' clamp with reel to the entire satisfaction of Engineer-in-Charge including taking out burnt winding wire after opening the ceiling fan and other unserviceable parts, of size: -
Ceiling fan 1200 mm sweep
Ceiling fan 1400 mm sweep
Exhaust fan 300 mm sweep
Exhaust fan 450 mm sweep
Wall mounted fan 650 mm sweep
Flame proof Exhaust fan 300 mm sweep
Flame proof Exhaust fan 450 mm sweep
NOTE: Collecton of fan items from EM store yard, transporting to workshop and back including loading unloading shall be measured & paid for separately under respective items of BoQ.
S&F PVC insulated & sheathed stranded aluminium conductor two core cable 1100 Volts of size 10 sq. mm ( nominal area) along with GI wire 4 sqmm conforming to IS 694 IN REPLACEMENT complete all as specified and directed.
M&L for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI wire 4 mm dia (upto the cross arms) by means of GI bolts/nuts/washers, protected by 15 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI light grade pipe for watering and including funnel, wire mesh, factory made PCC earthing pit chamber & cover including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of MES Schedule Part – I. NOTE:- (i) Factory made PCC pit chamber shall be provided at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.
S&F, fan capacitor IN REPLACEMENT of following size: -
S&F, Fan canopy suitable for 1200/1400 mm sweep ceiling fan IN REPLACEMENT complete all as specified and directed
S&F, Fan hanging clamp complete rubber reel nut bolt washer suitable for 1200/1400 mm sweep ceiling fan IN REPLACEMENT complete all as specified and directed
S&F Electric meter box, out door type, made out of MS CRCA sheet not less than 2 mm thick of size 650x900x250 mm with cable gally at centre and six compartments (for fixing electric meters) each have separate hinged door including provision of glass of size 90x90mm for taking reading, weather/ vermen proof IP-46 protection including provision of high quality rubber bedding on panel door, cable entry arrangements at bottom, all surfaces duly powder coated of shade approved by Eng-In-Charge and fixed in position with cement mortor (1:4), complete all as specified and directed.
S&F Exhaust fan 250 mm sweep with blades, frame and louvers, AC single phase, 230 V, plastic body, heavy duty, fixed to wall with 10 mm dia fasteners, nuts & bolts and connecting up from ceiling rose or connector to fan, complete all as specified and directed.
S&F Exhaust fan 300 mm sweep with blades, frame and louvers, AC single phase, 230 V, steel body, heavy duty, fixed to wall with 10 mm dia fasteners, nuts & bolts and connecting up from ceiling rose or connector to fan, complete all as specified and directed.
DISMANTLING/DEMOLITION WORKS
Demolition of plain Cement Concrete in ground floor and paving not exc 15cm thick (below or above) ground level complete all as specified and directed.
Dismantling asbestos cement (Corrugated, semi corrugated ) sheet as in roof covering complete all as specified and directed.
Demolition brickwork or stone / boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed
Dismantling timber scantling under 40 sq. cm, in any position, complete all as specified.
Dismantling framed wooden trusses of any description of span not exc 10 m, complete all as specified.
Dismantling structural steel works or of any description / type including doors, gates etc complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, gypsum, POP, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete with batten, casing caping of MS or and PVC conduit on surface or concealed, including switches, ceiling roses, pendants, regulators, sockets, mild steel terminal boxes etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified and directed.
Taking down carefully copper/aluminium sub main wiring complete, including existing batten/conduit consealed/surface etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified and directed.
Dismantling of unservisible existing DBs of any description with all accessories and MCBs, isolators etc. and making good surface as per existing, complete all as specified and directed.
Taking down carefully light fitting of any description, complete all as specified and directed.
Taking down carefully electric bell/buzzer of any description, complete all as specified and directed.
Taking down carefully service cable of any description, complete all as specified and directed.
Notes: Amount of credit for retrieved materials is mentioned in tender documents in pdf form which will be deducted while acceptance of tender offline.
PARGATI TOWER CORPORATION (BID ID -3270122)
AAR KAY BEE ENTERPRISES (BID ID -3270847)
KAMAL AGGARWAL (BID ID -3269701)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .