Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹16.3 L+₹72,303 (4.65%)Rejected-Finance 32 GRAND SQUARE DANAPUR CANTT PATNA PIN 801503 | PATNA | PATNA | BIHAR | 801503 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹16.6 L+₹1.0 L (6.72%)Rejected-Finance ATAL JI KI GALI SHINDE KI CHHAWANI LASHKAR GWALIOR MADHYA PRADESH 474009 | GWALIOR | MADHYA PRADESH | 474009 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹17.1 L+₹1.5 L (9.86%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹17.6 L+₹2.1 L (13.5%)Rejected-Finance SADAR BAZAR DANAPUR CANTT PATNA 801503 | PATNA | PATNA | BIHAR | 801503 | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
5 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GARRISON ENGINEER (MES) DANAPUR CANTT
REPAIR MAINT OF LT OVER HEAD LINE POLES LT CABLES AND OTHER ALLIED WORKS IN AGE EM UNDER GE DANAPUR CANTT
2020_MES_359393_1
GE/DNR/T-17 OF 2020-21 / 8393/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
DANAPUR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER
₹30,000
11 Aug 2020
8 Jul 2020
7 Aug 2020
8 Jul 2020
5 Aug 2020
20 Jul 2020
8 Jul 2020 - 19 Jul 2020
90 days
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cables & foundation of poles , stay assembly and getting out in any type of soil complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and exc. 1.50 m in depth but not exc 3.0 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm each layer ,complete all as specified and directed.
Removing excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point ,complete all as specified and directed.
M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable and gentally hand ramming and consolidation etc. complete all as specified and directed. Note :- Thickness of sand shall be measured 18 cm thick after punning.
M & L for old size sub class ‘B’ bricks, laid in trenches as cable covers / protection complete all as specified and directed.
M & L for plain cement concrete, 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M & L for plain cement concrete, 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M & L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in copings to poles & the like, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed.
Supply and erecting steel tubular pole, swaged, complete with cast iron base plate, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paints, type 410-SP-31 (9 meter long) complete, Including disconnecting and taking out old damage PCC pole all as directed. Note Excavation & Earth work and PCC foundation/base shall be measured and paid separately under relevant items of this BoQ.
Supply and stringing ACSR conductor of any size from LT over head line as directed including fixing to insulators with proper size of binding wire complete all as specified and directed.
Dismentling and taking out broken serviceable ACSR conductor from existing poles / dismantled poles / pole structures of any size from LT over head line as directed and keep in safe custody for re-use if found serviseable complete all as specified and directed.
Fixing only and stringing ACSR conductor of any size to LT over head line as directe including fixing to insulators with proper size of binding wire complete all as specified and directed. NOTE :- ACSR conductor obtained under item No-12 shall be re-used.
M & L for Restraining of LT over head line single ACSR conductor comprising of any size of conductor aluminium/copper/GI after opening binding wire from insulators and replace binding wire and achieved permissible sag limit of over head line conductor complete all as directed and specified. Note - Rate quoted by the contractor shall be deemed to include for cutting/trimming of tree branches wherever touching the over headline around one metre clear of over head line and removing trimmed branches as directed. Nothing extra shall be paid on this account.
Dismentling of old unserviceable earth wire or distributor span, cardle ground etc. complete all as specified and directed.
Supply and straining GI earthe wire of 4 MM dia on over head line 9 M pole maintaing proper sag as per IE rule complete all as specified and directed.
Supply and Fixing in repair Cardles, Hexagonal / Rectangular, fabricated with galvanised steel wire 4 MM dia complete all as specified and directed.
Supply and fixing GI stay wire of 7/4 SWG upto required length including taking out and u/s one complete all as specified and directed.
Supply and fixing mild steel galvanised stay assembly set complete comprising of 14mm dia, 400mm long stay bow, 2150mm long stay rod 20mm dia, 300mm x 300mm x 6mm stay plate, thimble, all as shown in electrical plate No.1 of MES Schedule part-I 2010 complete including dismantling and taking out old damaged stay complete all as directed. Note :- PCC , earth work and Insulators etc shall be measured and paid separately.
M & L for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of aluminium paint over a coat of red oxide primer, complete all as directed including dismantling and taking out damage/rusted cross arms, bracings, supports, clamps and back plates from existing poles / dismantled poles / pole structures complete all as specified and directed.
Dismantling and taking out servicable cross arms, bracings, supports, clamps and back plates from existing poles / dismantled poles / pole structures complete all as specified and directed.
Fixing only cross arms, bracings, supports, clamps and back plates of any size to LT over head line as directe including fixing accessories complete with suitable size complete all as specified and directed. NOTE :- Cross arms, bracings, supports, clamps and back plates are obtained under item No-21 shall be re-used.
S&F Danger notice plate of 1.6mm thick mild steel sheet vitreous enameled white with letter figures and conventional skull and bones in signal red colour and fix with MS clamp for LT size 20 X 15 Cm fix in repairs complete all as specified and directed.
Dismantling and taking out servicable insulators of any size and any type from existing poles / dismantled poles / pole structures complete all as specified and directed.
Fixing only insulator of any size and any type to LT over head line as directe including fixing accessories complete with suitable sizecomplete all as specified and directed. NOTE :- Insulators are obtained under item No. 24 shall be re-used
S & F Pin type, porcelain, vitreous, white, brown or green insulator, 100mm height, 65 mm dia for 1100 volts grade including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut complete all as specified and directed.
M&L for Shackle type insulator from LT overhead line and S&F new Shackle type, porcelain, vitreous, white, brown or green insulators 100mm dia and 115 mm height for working pressure 1100 volts including galvanised mild steel strap 31 x 3mm size, washers, 14mm dia insulator bolts, washers & nuts complete all as specified and directed.
Supply and fixing in repair PVC insulated, stranded aluminium conductor served with inner sheathing PVC tape and over all PVC sheathed in service connection suspended by insulating hanger not more than 1 meter apart including 4 mm dia GI suspension wire of wire 10 Sqmm 2 core,complete all as specified and directed.
M& L loop type, porcelain, vitreous, white, brown or green insulator, 65 x 90 mm , clearence of hole 16 mm for 1100 volts grade including fixed in repairs complete.
Cutting & trimming tree branches along LT over head lines after taking all precautions while working on lines such as taking shut down , safety equipments etc . and clearing of area and removing the same from site to a distance not exceeding 50 mtr complete all as specified and directed. NOTE: Contractor shall be responsible for cutting of grith of tree branches upto 50 mm dia with the grith of tree branches above 50 mm dia & rate shall be deemed to be unit quated rate.
Cutting of grass, at sub stations / EM Istallations and surrounding areas etc complete or when and where directed and removing the same from site to a distance not exceeding 50 mtr complete and spreading of bleaching powdwe at the rate 1 kg/1o sq meter for stop the abnomal grouth of grass complete all as specified and directed.
S & F in repair for LT line PVC Spacers spiral type for the following :-
Spacer for two wire
Spacer for three wire
Spacer for four wire
Spacer for five wire
Supply and fixing four pole changeover switch disconector with advance neutral 415 volt 50 Hz 200 amps in sheet steel enclosure and Conforming to IS / IEC : 60947 - 3 including dismantling old one complete all as directed. Make - L & T /Siemens/Schneider.
Supply and fixing four pole changeover switch disconector with advance neutral 415 volt 50 Hz 400 amps in sheet steel enclosure/ side handle and Conforming to IS / IEC : 60947 - 3 including dismantling old one complete all as directed. Make - L & T /Siemens/Schneider.
Supply and fixing four pole changeover switch disconector with advance neutral 415 volt 50 Hz 100/125 amps in sheet steel enclosure and Conforming to IS / IEC : 60947 - 3 including dismantling old one complete all as directed. Make - L & T /Siemens/Schneider.
M & L for Painting of steel pole with cross arms, clamp of any length and shape for LT overhead line with single coat of aluminium paint including preparation of the existing surface including marking pole numbers in a 20 cm dia yellow circle & marking six black & four yellow bends width 15 cm by fluorescent paint, from bottom of pole to 1.5 Mtr height and providng three nos of Red ,Yellow & Blue of reflecting strip of 25 mm width adhesive PVC tape around the pole at suitable height complete all as specified and directed.
Removing of old Un used /Damage LT PCC / Steel pole PCC including excavation retureing filling & breaking of PCC foundation & deposited to complete all as directed as directed.
M & L for Earthing to OH /Sub stn with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead GI wire 4 mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES Schedule part-I 2009, GI earth lead wire protected by GI pipe 15mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and directed. Note : Main earth lead beyond 7.5 meter shall measured and paid saperatly.
Ditto all as per above item No - 38 but main earth lead 32 x 6 mm galvanised iron strip complete all as specified and directed.
Supply and fixing in repair for Earth continuity conductor or main earthing lead of 4 mm dia galvanized iron or steel wire, buried in ground or fixed to wall complete all as specified and directed.
Supply and fixing in repair for Earth continuity conductor or main earthing lead of 32 x 6 mm galvanized iron strip, buried in ground or fixed to wall complete all as specified and directed.
Taking up underground unservicable cable of any size from existing trench including bricks, etc and removing of materials from work site complete all as specified and directed.
Supply, laying & testing for XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 150 Sqmm nominal cross section x 3.5 core complete all as specified and directed.
Ditto all as per item No. 43 but Size 95 Sqmm X 3.5 core
Ditto all as per item No. 43 but Size 25 Sqmm X 3.5 core
Ditto all as per item No. 43 but Size 16 Sqmm X 4 core
Ditto all as per item No. 43 but Size 10 Sqmm X 2 core
Laying or fixing or passing in trenches / on pole / through pipes etc only including connection and testing of XLPE insulated , armoured heavy duty electric power cable with stranded aluminium conductor opf any size complete all as specified and directed. NOTE :- Old Cable shall be used obtained from under item No. 42.
Supply and fixing in repair GI tubing, light grade, 40 mm bore with all fitting laid in trenches / pole / wall for protection of cables complete all as specified and directed.
Supply and fixing in repair GI tubing, light grade, 80 mm bore with all fitting laid in trenches / pole / wall for protection of cables complete all as specified and directed.
M/s KUMAR ENTERPRISES
RAJ AND SONS
HARINANDAN RAI SONS
RC GUPTA AND SONS
M/S SAROJ KUMAR SINGH
M/S SHOBHA CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .