Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.2 LAccepted-AOC PLOT NO 52 BAKSHI NAGAR JAMMU 180001 J K | JAMMU | JAMMU | JAMMU AND KASHMIR | 180001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹39.3 L+₹1.5 L (3.85%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹39.3 L+₹1.5 L (4.03%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹43.7 L+₹5.8 L (15.4%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹44.9 L+₹7.1 L (18.8%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
25 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS PIN 913862 c/o 56 APO
Special repair to bldg No T-48 T-11 T-40 T-50 T-53 ESH-04 ESH-07 T-01 T-02 provn of grill gates near watch tower and certain revenue works under AOR of AGE B/R Dett A at Naushera
2020_MES_390750_1
GER-50/2020-21
Open Tender
Civil Works
Item Rate
270 days
GE 862 EWS
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹1 L
Yes
11 Dec 2020
28 Oct 2020
27 Nov 2020
28 Oct 2020
25 Nov 2020
11 Nov 2020
60 days
Amount
Sch 'A' Part-I B/R Works Demolition of cement concrete (unreinforced) in ground floor and paving n exc 15 cm thickness below or above the ground level complete all as specified and directed.
75mm thick PCC type C-1, 1:3:6 (using 20mm graded stone aggregate) as in plinth protection, laid in slope 1:12 from outer edge of the wall, finished even and fair, laid in alternate bays including providing 6mm wide joints throughtout thickness of plinth protection in concrete bays and in between walling and plinth protection, joints filled mastic filling comprising of one part of heated bituminous 85/25 and 3 parts of sand(all by weight) complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frames) n.exc 1.5 Sqm each and removing to store complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frames) exc 1.5 Sqm but n exc 4.00 Sqm each and removing to store complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Walling of random rubble masonry, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed.
Walling of random rubble masonry (except stone), uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed.
Extra over stone walling for hammer dressing to face stones and dressing of face beds with maximum depression on face from straight edge held against the dressed surface n exc 40 mm and joints, as specified, of random rubble walling, uncoursed or brought upto courses complete all as specified and directed.
4mm thick designer ceiling board in ceiling fixed with screw as per manufacturers instructions , laid over and including hot dipped galvanised iron in post grid with 24mm wide T section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33 mm thick galvanised steel sheet of size 24 x 32 x 300 mm spaced at 12 mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 4 mm dia to be fixed by approved rawl plug, level adjusters and screws etc. The last hanger at the end of each main runner shall not be greater than 450 mm from adjustacent wall flush fittings of 1200 mm long screws Tee with (double stiching) to be interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm modules cross tee longer than 600 mm modules to be formed by fittings 600 mm long cross tee, tee perimeter wall angle shall be of 0.45 mm thick galvanised steel of size 19 x 19 mm and 300 mm long of white colour all as per insturctions inlcuding dismantling of exisiting board and cover fillets complete all as specified and directed.
Dismantling timber scantling 40 Sq cm and over in section, in any position (framed work) complete all as specified and directed.
Roof trusses (framed), trussed, purlins, cranes gantries, , rails and fastening and heavy brackets framing (beam, tea, angle, channel or flat section) including distance pieces, cleats, etc. conforming to Fe-410-W (Gde - E-250) quality A complete all as specified and directed.
Mild steel work as in wind ties using flat iron including all necessary drilling bolting, riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10 cm long and slote 18 to 20mm complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nanital or similar pattern roof covering complete all as specified and directed.
Pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in roof covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
Pre-painted galvalume aluminium zinc coated GI based plain steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in ridges, fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Rendering 20mm thick on stone masonry in CM 1:6, finished even and smooth without using extra cement complete all as specified and directed.
Rendering 20mm thick on stone masonry in CM 1:4, finished even and smooth without using extra cement complete all as specified and directed.
Demolition of reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground) complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Mild steel TMT bars 6mm to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends as in stirrups, spacers and binders including binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Reinforced cement concrete 1:1½:3 type B-1 (using 20mm graded aggregates) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
Pressed steel door frame of size 125x60 mm with one or more rebates including necessary fixing lugs, hinges, lock and strike plate etc including back filling to chowkhats in PCC 1:3:6 type C-0 using 12.5mm graded stone agregate complete all as specified and directed.
Factory made 2nd class hard wood 35 mm thick plain framed panelled shutters (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
Factory made 35 mm thick 2nd class hard wood glazed and skelton shutters open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and directed.
300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
Second class hard wood(Hollock) small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary labours; articles n exc 200 cu. cm each, complete all as specified and directed.
PCC type B-1, 1:2:4 (using 20mm graded aggregate) as in coping, benching, hold fast, water troughs, bed block and the like including weathering, slightly rounded or chamfered angle and throating incuding necessary form work complete all as specified and directed.
Stainless steel wire cloth, 0.56mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
Butt hinges 100mm medium weight cold rolled mild steel complete all as specified and directed.
Extruded aluminium alloy handles size 150 mm fabricated type anodised complete all as specified and directed.
Aluminium anodized barrel tower bolts 200 mm long of extruded section all as specified and directed.
Aluminum alloy, anodised, sliding door bolt 200mm long, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
Preparation of new steel surface exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Preparation of new wooden surface exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of cement primer complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat wall care putty complete all as specified and directed.
Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
Rendering 15mm thick in CM 1:6 on fair faces of brick work, surface finished even and smooth without using extra cement complete all as specified directed.
Supply only integral water proofing compound complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing rubbish off the premises complete all as specified and directed.
Vitrified tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exc 0.36 sqm but not exc 0.42 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, laid over and including 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
Vitrified tiles light shade 10 mm thick on vertical surfaces such as skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, laid over and including 10 mm thick screed bed in CM 1:4 complete all as specified and directed.
Glazed ceramic coloured tiles of size 450x 300x7mm thick as on vertical surface of wall such as skirting, dado, riser etc,set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile complete all as specified and as directed.
0.63 mm galvanised, corrugated mild steel sheeting with two corrugation side lap, fixed with 'L' or 'J' type hooks or cranked hook bolts and washers in roofs, walls etc with grade of zinc coating 275 gm/sqm complete all as specified and directed.
0.63 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of Zinc coating 275 gm/sqm complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, landings and similar work; n exc 200mm thick (Horizontal and sloping) for rough finished surface of concrete complete all as specified and directed.
Reinforced cement concrete type B-1, 1:2:4 (using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams, columns , roof, landings, shelves and the like complete all as specified and directed .
Taking down aluminium doors/window of any description including all fittings and fixtures complete all as specified and directed.
Anodised aluminium frame for doors, windows and ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
Anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, mortice lock, 1 No, floor door stopper, anodised aluminium snap beading, screws etc including powder coating of any colour (thickness of powder coating not less than 50 micron) complete all as specified and directed.
Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed.
5.5mm thick sheet glass, ordinary quality fixed to aluminium doors in square exc 0.5 sq. m in each pane complete all as specified and directed.
12mm thick prelaminated partical board, interior grade both side decorative choice lamination fixed to aluminium doors or as in cup board cabinets similar works complete all as specified and directed
Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg Aluminium (extruded section) body complete all as specified and directed.
Brass mortice lock vertical type 100mm long with 4 levers complete all as specfied and directed.
PVC (SWR) pipes type 'B' single socketed in any length with rubber ring joints , laid in trenches or in floor, of bore 110 mm complete all as specified and directed.
Taking up or down GI tubing 15 mm bore and connections including cleaning for refixing or removal complete all as specifed and directed.
Taking up or down GI tubing 20 mm bore and connections including cleaning for refixing or removal complete all as specifed and directed.
15 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors complete all as specifed and directed.
20 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors complete all as specifed and directed.
Gun metal/glove valve with iron wheel head screwed on both sides for iron pipes of 15mm internal dia complete all as specified and directed.
Gun metal/glove valve with iron wheel head screwed on both sides for iron pipes of 20mm internal dia complete all as specified and directed.
Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
Rotational moulded polythylene water storage tank (ISI marked) with float valve, plastic lid cover, double layered, cylindrical vertical with closed top hoisted and fixed in position of capacity 500 ltrs including dismantling old unserviceable tank and making connections inlcuding suitable GI wash out, over flow, nipple and including ball valve of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (minium weight 15mm-142 gms including dismantling existing tanks complete all as specifed and directed.
15mm bore fancy type pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
Bib tap cast copper alloy with crutch or butterfly handle, chromium plated, fancy type, screwed for iron pipe, suitable for 15 mm bore complete all as specified and directed.
15mm Stop valve (concealed type), cast copper alloy screwed down, high pressure with crutch or butterfly handle, chromium plated, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Chromium plated shower rose 15mm dia including shower arm and dia of shower minimum 73mm fancy type with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.
Brass chromium plated tubular towel rail 20 mm dia "D" type 60 cm long between flange, aluminium anodised complete all as specifed and directed.
Chromium plated cast copper alloy health faucet to EWC with complete fitting and fixture of approved quality complete all as specified and directed.
Dismantling fillets, posts, rails, rafters purlins etc under 40 Sqcm in section unframed work complete all as specified and directed.
250 mm long mild steel sliding door bolt plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed.
Vitreous China wash down water closet pan pedestal pattern white one piece complete with flush mounted on EWS excluding fixing bolts and flushing cistern and flush pipes etc complete all as specified and directed.
Viterous china wash down water closet pan, white (pedestal pattern), including plastic water closet seat, black/white, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device, (excluding fixing bolts, flushing cistern and flush pipe) and inlcuding set of CP jet with PVC pipe of superior quality complete all as specified and directed.
MS tubular Box type window (double rebate and double shutter) of MS rolled steel section conforming to IS-1038 and shall be ISI marked manufactured by ISI approved manufacturer, openable frames shall be fabricated of sections as approved by Engr-in-Charge, corner welded to form a solid fused welded joint, handles shall be of z section welded with openable frame box steel section used in outer frame, shutter frame and central frame shall be ERW secton of 16 gauge with fixing lugs to be fixed as per provision of IS-1038 except that top lugs shall not be provided , all shutters of windows shall be provided with 4 Nos friction free hinges, 2 Nos 75 mm tower bolts to each leaf of window one at top and one at bottom welded on 3 mm thick steel sheet piece of suitable size which shall be in turn welded to z section of steel window to provide suitable arrangement of using tower bolt. Glazed, gauzed window , mild steel casement stays 300 mm with hinged joint and two plates with studs complete all as specified with all fittings and fixtures with or without glazing bars complete all as specified and directed.
Applying two coat of distemper oil emulsion over a coat of wall care putty on old surface complete all as specifed and directed.
75mm thick PCC 1:5:10, type E-2 using 40mm graded stone aggregates as in sub base of floors complete all as specified and directed.
Machine pressed precast concrete interlocking paver block of any shape and size approved by EIC, ISI marked (IS:15658-2006) 80mm thick, M-40 grade (Medium Traffic), in paths and hardstanding,with grey cement and pigment, laid tightly over & including 25mm thick dry sand cushion (compacted) and joints filled with dry sand, colour and pattern as approved by GE, complete all as specified and directed.
Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E- complete all as specified and directed.
Two coats of cement base paint on old surface complete all as specified and directed.
Two coats of oil emulsion paint on old surface over and including a coat of wall care putty complete all as specified and directed.
40mm thick PCC type B-1 1:2:4 (20mm graded aggregate) as in padding in roof surface to maintain proper slope finishing concrete surface even and smooth without using extra cement complete all as specified and directed.
Complete removal of existing water proofing treatment over RCC roof, projections of any thickness, any type by stripping out old tar felt over roofs, parapets, chimney stacks etc laid horizontally or vertically including taking out layer of cement plaster etc and cleaning the surface with wire brush including removing debris from the site and depositing in low lying area where directed and providing following :- (a) Rendering 10mm thick in CM 1:3 on concrete roof surfaces and finish the surface even and smooth without using extra cement including mixing water proofing compound @ 2% by weight of cement. (b) Apply a coat of bituminous primer confirming to IS-3384@ 0.4 ltr/Sqm on newly plastered surface after curing as per IS-456 and dried. (c) After the primed surface has dried, apply a coat of hot blown bitumen(85/25 penetration) confirming to IS-702 @ 1.2 Kg/Sqm of the surface. (d) Provide polymeric water proofing membrane ISI marked laid with overlaps, bonded with hot blown bitumen, and laid by torch application method, end overlaps shall not be less than 150mm and side lap 75mm. Polymeric water proofing membrane should be five layered with centre core as 90 micron high molecular high density polyethylene film, min weight 3 Kg per sqm. APP membrane shall laid acorss the slop from lowest line of sloping roof towards ridge. (e) Over the APP membrane, apply a coat of semi hot blown 85/25 penetration grade bitumen confirming to IS-702 @ 1.20 Kg/ sqm and blinded with fine sand in dry condition @ 0.50 Kg / Sqm dusted over the bitumen coat Note : (i) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (ii) Ponding test shall be conducted for 72 hrs as directed.
Rendering 15mm thick in CM 1:4 on brick/concrete surfaces on walls, finished even and smooth without using extra cement complete all as specified and directed.
Rendering 10 mm thick in CM 1:3 on ceiling finished even and smooth without using extra cement complete all as specified and directed.
Preparation of newly plastered surfaces on walls and applying three coats of white wash complete all as specified and directed.
Preparation of newly plastered surfaces on ceiling and applying three coats of white wash complete all as specified and directed.
PCC 1:4:8, type D-2 (using 40mm graded stone aggregate) in foundation filling and mass concrete complete all as specified and directed.
Mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to complete all as specified and directed.
Reinforced cement concrete 1:2:4 type B-1 (using 20mm graded aggregates) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
Non skid ceramic coloured tiles 7 to 8 mm thick (Ist quality) Square/rectangular, area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors, etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 15mm thick screed bed in CM 1:4 complete all as specified and as directed.
100mm thick plain cement concrete type D-2, 1:4:8 (using 40mm graded aggregate) as in sub base complete all as specified and as directed.
150mm thick plain cement concrete type B-2, 1:2:4 (using 40mm graded aggregate) as in floor complete all as specified and as directed.
Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound complete all as specified and as directed.
Forming 12 mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘B’ r complete all as specified and as directed.
Demolition of cement concrete unreinforced in any position on roof slab complete all as specified and as directed.
Sch 'A' Part-II (E/M works) Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
Point wiring for one light point/fan point controlled by one-one way switch with 1.5 Sqmm (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable drawing in and including non metalic rigid PVC casing & caping complete with all acessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated bakalite sheet as top cover, and 1.5 Sqmm (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly compete all as specified and directed.
Description all as per Serial item No 101 above but for one 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
Description all as per Serial item No 101 above but for one 3 pin 5 Amp socket outlet on same board complete all as specified and directed.
Description all as per Serial item No 101 above but for one 3 pin 15 Amp socket outlet independent with cable 2.5 sqmm PVC insulated FRLS multistranded copper conductor cable with 2.5 sqmm single core multistranded FRLS copper conductor cable as earth lead complete all as specified and directed.
Switch piano, flush type single pole, one way 5 Amp, 240 volts complete all as specified and directed.
Switch piano, flush type single pole, one way 15 Amp, 240 volts complete all as specified and directed.
Socket 2 in 1, 3 pin 5 amp flush type complete all as specified and directed.
Socket out let 2 in 1, multipurpose 5 & 15 Amp flush type complete all as specified & directed.
Ceiling rose two to three terminal (65 x 50mm), PVC/ polycarbonate insulated body complete all as specified and directed.
Ceiling fan regulator elctronic, stepped type, hum free suitable to control speed of fan from 0 to 100% rotary type five step 240 volts AC complete all as specified and directed. Make Bajaj /Usha/havells/CG
Lamp holder insulated body PVC/ Polycarbonate type with back plate suitable for batten/angular/pendent fittings including LED lamp 07 watt complete all as specified and directed.
LED Tube light fitting T-5 LED, Battens type 1x 20 watts, 4 feet white Indoor decorative aluminium extruded, integrated type complete with all accessories prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm complete all as specified & as directed by Engr in Charge. Make C&S model No. LTTB4F20WLED P/W or equivalent in Philips/Havells/Bajaj
Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m depth for laying of cable and foundation of poles and stays and n. exc 10sqm on plan and getting out in any type of soil complete all as specified and as directed.
Sand cushioning to underground cable, provided with a layer of 8 cm deep before laying the cable and 15 cm thick after laying and stretching jointing and testing the cable complete all as specified and as directed Note: Punned thickness of sand shall be measured and paid.
Supply laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sq mm 2 core laid in trenches/ on poles/ under road crossing etc. complete all as specified and directed. complete all as specified and directed.
Supply laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sq mm 2 core laid in trenches/ on poles/ under road crossing etc. complete all as specified and directed. complete all as specified and directed.
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat, size 230mm x 115mm x 75mm, complete all as specified and as directed
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm (soil) thickness all as specified and directed.
Removing of excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Sheet metal enclosure MCB distribution board single pole & neutral 430 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including cutting and chases wall for fixing DB and making good disturbed wall surfaces to match with existing specification (Note-MCBs will be measured and paid for separately).
MCB SP 240 volt any rating from 5 to 32 amps conforming to IS 8828 of 1996, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified & directed.
MCB SPN 240 volts 40 amps conforming to IS 8828 of 1996, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified & directed.
Street light fitting LED 30 watt (18x25) made up of grey powder coated pressure die cast aluminium housing having IP66 control gear and lens compartment. Fixture should have isolation in lense compartment and driver compartment and fitting must be top openable for easy maintenance and remain intact its IP protection forever after once it is open for repair. IP protection should be intacted for enhancing the overall efficiency of light. Fixture and driver should be of same make. Driver of the fixture must have enclosure and having vent from ends to prevent the driver from condensation effect and it should be BIS approved and R number should be mentioned on the top of the LED driver having voltage band of 110-300 Volts AC, THD <10% KV and also having surge protection inbuilt on driver is min 5KV and external SPD of 10KV outside the driver inside the fixture to prevent the fixture from non requirerd SUGRG. Driver should be equipped with over voltage short circuit and reverse polarity protections, driver must be constant current and constant voltage based (CVCT) fitting should having system efficiency of more than 100 lumens/watt. Fixture should be equipped with secondary lenses for better distribution of light. OEM must have its own manufacturing facility in regards to this OEM must produce the necessary documents of its own manufacturing along with the details of testing equipment and the respective Make : Crompton Cat Part No LSTP-30-CDL or its commercially and technically equivalent in Bajaj/Philips/Havells/C&S Note :-1. Contractor shall obtain LM 79 and LM 80 test report (Electrical, photometry and chromaticity) (from third party NABL Lab only and inhouse NABL lab test will not be considered) for the light fitting from the manufacturer before supply of material and submit to the department. 2. A certificate of Guarantee shall be submitted by the contractor for period of 3 (three) years from the certified date of completion of work as a whole for repair/replacement of lamp and light fittings to GE. Performance guarantee amount @5% of quoted amount of LED lamp and light fittings shall be kept reserved for a period of three years. Accordingly ,performance guarantee amount shall be released after gaurantee period. 3. The manufacture LOGO shall be embossed into housing of luminaire. 4. Luminarie shall be provided with all parameters mentioned above. 5. Make of LED chip should be Cree, Nichia, Lumiled, Osram.
Street light bracket made up of 40mm bore light grade GI pipe 1.2 mtr long including necessary bending welding etc complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion complete all as specified and directed.
GI pipe 40mm bore light grade (ISI marked) with all fitting fixed to wall, poles or under road crossing etc with suitable size clamps for protection of cable complete all as specified and directed.
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
CHAND CONSTRUCTION CO
M/S Narinder Pal Choudhary
M/S. Choudhary Dewan Chand And Sons
M/S Jyoti Parkash Tilak Raj Gupta
RAJINDER CHOUDHARY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .