| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC NO 131 5TH CROSS PASCHIM COUNTY MEDARAHALLI CHIKKABANAVRA POST BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | ₹24.2 L Quoted ₹25.4 L | L1 | Accepted-AOC Accepted Being Lowest |
| 2 | L2₹26.9 L+₹1.5 L (5.90%)Rejected-AOC 57 7 MEGHNAD SAHA SARANI PRADHAN NAGAR SILIGURI 734 403 DIST DARJEELING | SILIGURI | DARJEELING | WEST BENGAL | 734403 | ₹26.9 L+₹1.5 L (5.90%) | L2 | Rejected-AOC Rejected Being Lowest |
Tender Value
Refer Docs
EMD Value
₹56,000
Closing Date
1 May 2021, 6:00 pmClosed
Shri Vineet Modi
CWE AF North Bangalore Bellary Road JC Nagar Post Bangalore 560006
PROVISION OF CERTAIN B/R AND E/M WORKS INCLUDING ALLIED WORKS SERVICES AT COMMAND MEDICAL SECTION AT HQTC
2021_MES_431066_1
87423CWEAFNBAN
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF BANGALORE
AS PER NIT
5 documents required · 5 mandatory
₹500
GE AF BANGALORE
₹56,000
Yes
26 Jun 2021
16 Mar 2021
3 May 2021
16 Mar 2021
1 May 2021
20 Apr 2021
17 Mar 2021 - 26 Mar 2021
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations.
M&L for Vitrified Ceramic tiles in dark shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match as in floors etc. set and jointed in neat cement slurry over and including 15 mm thick screed bed of CM 1:6 complete all as specified.
All as per item No 2 above but as in skirting/dados etc on vertical surface complete over and including 10mm thick rendering of CM 1:4.
M&L for glazed ceramic coloured/digital tiles in vertical surface 350x250mm x 7mm/ 450x350x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4 complete all as directed.
M&L for Non-skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match in floors etc. set and jointed in neat cement slurry over and including 15mm thick screed bed of CM 1:6 and pointed in white/ coloured cement to match complete all as specified.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dresses stonework and precast concrete articles. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations.
M&L for Pre-cast cement concrete solid block masonry, with solid block exceeding 10cm in width, in PCC 1:3:6, type C1, using 20mm graded stone aggregates, set in cement mortar 1:4 all as specified and as directed.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. Including racking out joints, hacking for key, scrubbing down with water, etc. all as specified. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations.
M&L for Rendering 15mm thick on fair faces of brick works or concrete surfaces in CM 1:6 and finished even and smooth without using extra cement all as specified.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area exc. 1.5 Sqm n.exc 4 Sqm each complete all as specified & directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area n.exc. 1.5 Sqm each complete all as specified & directed.
S&F second class hard wood plain, solid, straight chowkats and frames wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints.
S & F 40 mm thick flush shutters solid core construction with particle board core and plywood face panel, and both faces are covered with decorative face veneer with lipping/frame to match complete all as specified and as directed.
M&L for French polish over a one or more coat of wood filler on New/untreated wooden surfaces exceeding 10cm width or girth including necessary preparation of surfaces all as specified and as directed.
Taking down shutters exc. 1.0 Sqm and n.exc 2.0 Sqm and refixing in same opening after easing complete all as specified
S&F 125mm long Butt hinges, medium weight, cold rolled mild steel,
S&F 200mm aluminium anodised barrel tower bolts of extruded section and fixed.
S&F 300mm long aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clip of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed.
S&F 150mm Aluminium handles, cast type anodised complete all as specified and directed
S&F door closer aluminium extruded section body hydraulically regulated, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed
S&F Sheet glass, of 4.8mm thick ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane.
S&F tubes 15mm bore, `medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors including taking up or down old steel tubing.
All as per item no 22 above but 20mm bore
S&F in repairs PVC (SWR) pipes 110mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors
S&F in repairs PVC (SWR) pipes 110mm bore, single socketed, in any length with rubber ring joints, fixed to wall
S&F in repairs PVC (SWR) bends 110mm bore of any radius
S&F in repairs PVC (SWR) bends 110mm bore vent cowl
S&F in repairs Grating doom 100mm dia of PTMT (Minimum weight 25gms)
S&F in repairs PVC (SWR) pipes 75mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors
S&F in repairs PVC (SWR) pipes 75mm bore, single socketed, in any length with rubber ring joints, fixed to wall
S&F in repairs PVC (SWR) bends 75mm bore of any radius
S&F in repairs PVC (SWR) bends 75mm bore vent cowl
S&F in repairs PVC (SWR) multi floor trap 75mm dia with grating including jointing with solvent cement
S&F in repairs 15mm two in one Bib taps, chromium plated, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified.
S&F in repairs premium quality 15mm bib tap with wall flange of make Jaguar or equivalent as approved by GE.
S&F in repairs concealed/angle stop valve 15mm bore, fancy type chromium plated with long shank and cup screwed down, high pressure with crutch or butterfly handle, for iron pipe or for unions and fixed all as specified.
S&F in repairs PVC connections 15mm size with PTMT nuts of length 600mm all as specified.
S&F in repairs Brass cromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges
S&F in repair Soap dish, any type of size approximate size 160 x 60x90mm,fixed to plug with chromium plated brass screws.
S&F in repair soap Dispenser Make-Jaguar Code No- ACN-CHR-1135 N or equivalent as approved by GE.
S&F in repair Toilet paper roll holder with flap of Make-Jaguar Code No- ACN-CHR-1153S or equivalent as approved by GE.
S&F in repair Towel rack without lower hanger of 600 mm long and 03 no hooks Make-Jaguar Code No- AHS-CHR-1581FHS or equivalent as approved by GE.
S&F in repair Towel ring square with round flange of Make-Jaguar Code No-ACN-CHR-1121N or equivalent as approved by GE.
S & F in repairs basin mixture with popup waste system with 450 mm long braided hoses all as directed Make: Jaquar CAN-169KNB or equivalent as approved by GE.
S & F in repairs clove counter top basin of size515x380x120mm of whitecolour complete all as specified and directed and as approved by GE.
Supply & fix Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with brass chromium plated bracket guard and railing 60cm long complete all as specified
Dismantling stone slab and tiles of any description or thickness laid bedded and pointed in any mortar in floors aprons etc
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/in ridges, fixed with self tapping screws as specified and directed.
S&F mild steel screw bolt (machine made with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed to be fitted with washer and one hexagonal nut, length of bolt exceeding 22.5 cm and not exceeding 30 cm long . Dia meter of neck is 16 to 20 mm.
S & F in repairs 18/19mm thick block boards, grade 2 quality interior grade, decorative type with decorative face veneer on both face, fixed with screws to timber frame work
S&F in repair ball catcher with 8 mm dia steel ball and brass body and striking plate including letting in and fixed complete all as specified
S&F in repairs stainless steel nickel coated oval shape handles 100 mm size fabricated all as specified and as directed .
S & F in repair Brass chromium plated 32 mm bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed
S&F in repair one piece floor mounted toilet water closet of size (WxPxH) 380x680x755mm white or tinted, S-trap, 220mm, trendy square design, slim UF ezee close seat cover, wash down system, dual flush (6/3 ltrs) mechanism and fixed in repairs with necessary fixing bolts/ screws etc complete all as specified.
S&F in repairs 15mm bore hand shower (Health Faucet) with 8mm Dia, 1 Meter Long flexible tube & wall hook.
M&L for preparation of old decorated surface of walls including washing, rubbing down and stopping of distempered and painted surfaces and applying one coat of distemper oil emulsion complete.
All as per item No 57 above but two coats of distemper oil emulsion on walls.
M&L for 2coats of Distempering wall with distemper oil emulsion white or tinted over a coat of 1mm thick wall care putty, including preparation of new surface all as specified.
Dismantling boarding, any description(wall pannelling/ ceilling/ linning/ cladding/ partition etc.) fixed in any position with nails/screw complete all as directed.
S & F Solid PVC Wall Lining consisting of 5mm thick Plain colour /texture colour PVC sheet inclusive of solvent cement and fixing atsite on PVC frame as per specifications and drawing.
5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing
M&L for Preparation of old painted surface of any description not otherwise described wood and wood based surfaces over 10 cm width of girth and applying one coat of synthetic enamel paint.
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth, for foundation etc, or for shafts, wells cesspits, manholes, pier holes etc n exc 10 sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil.
Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick in soft / loose soil complete all as directed.
Removing excavated materials out side MoD land exc 5Km and depositing where directed at a level not exceeding 1.5m above the starting point in soft/loose soil.
M & L for cement concrete type C-2, 1:4:8, using 40mm graded aggregate as in foundations, fillings and mass concrete.
S & F structural steel for Stairs (framed) including stringers, treades, landing, balusters, hand rails,girders etc. including cleats, brackets, Fe-410- W(Gde-E-250)quality-B etc.complete
Use & waste form work to sides and soffits of slab or roof beam, beam haunchings, girders, bressumers, lintels, cantilevers, shelves, including supports overhangs, etc finished fair and smooth on flat complete all as directed.
M&L RCC (Nominal mix) in type B1, 1:2:4 (20mm graded aggregate) in slab supported walls, beams and columns in floors, roofs, landings, lintels, cantilevers, shelves,stairs etc complete all as specified and directed.
Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for RCC (nominal mix) type B1 1:2:4 (using 20mm graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for coloumns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L MS TMT bars 10 mm dia and over cut to length bent to shape required including cranking bending and binding with MS wire annealed not less than 0.9 mm dia all as specified and as directed
All as per item No 73 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.
M&L for preparing of new surface of ceilling or soffit of stair and applying two coats of cement base paint on new surface all as specified.
S&F Granite (of any type) work 20mm thick (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like including15mm thick in cement mortar (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.complete all as directed
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations
Preparation of new/untreated steel surface of any description not otherwise described steel and iron surface over 10 cm width or girth and applying one coat of synthetic eanmel paint.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
S&F modular hinge cast brass 75 mm size bright finish all as specified and directed.
S&F brass tower bolt decorative type 100 mm long extruded section complete all as directed.
S&F anodised aluminium frame powder coating, for doors, windows, ventilators /fixed partition etc.with one or more rebates including joining cleat for fixing,rubber packing etc. complete all as specified
S&F Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. complete all as specified
S&F powder coated anodised aluminium sliding window and ventilator shutters, without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified
S & F for 10mm thick plaster of paris double layer ceiling (gypsum anhydrous) to flat surface over anodised aluminium snap grid frame work for false ceiling with hangers 3 mm dia. GI (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long incl two coats of distempering the board with distemper oil emulsion white or tinted over a coat of 3 mm thick wall care putty after preparation of new surfaces inclu necessary cutting securing and making good to disturbed surface etc. complete all as specified.
Taking down carefully copper/aluminium point wiring (light fan socket or power) complete including fittings such as switches, ceiling rose, pendants, regulators, sockets complete as directed and removing retrieved materials and making good the disturbed surface all as specified and as directed
Taking down existing light fittings of any description from wall/ ceiling and making good the disturbed surfaces of walls all as specified and as directed.
Material and Labour for wiring complete 1.5 sqmm FRLS grade single core PVC insulated, unsheathed, 1100V grade copper multistranded conductor drawn through and including rigid non metallic conduit of any dia in walls, roofs floors etc including PVC insulated copper earth continuity conductor 1.5 Sqmm cable connected to common earth dolly including factory made terminal boxes suitable for modular switches, sockets, modular plates to accomodate modular switches & plates including all cutting/chases etc in walls all as specified and directed for :- One light/ fan point controlled by one single pole 5 Amps switch
All as per item No 88 above but One switch socket out let point 5 Amps on independent board
All as per item No 88 above but One bell point controlled by one single pole 5 Amps bell push
All as per item no 88 above but for PVC insulated FRLS copper conductor of size 2.5 sqmm for switch socket multipurpose 15 Amps including provision of 2.5 Sq mm PVC insulated FRLS copper conductor cable as earth continuity conductor on independent board
All as per item no 88 above but for PVC insulated FRLS copper conductor of size 4.0 sqmm for switch socket multipurpose 15 Amps including provision of 4.0 Sq mm PVC insulated FRLS copper conductor cable as earth continuity conductor on independent board
Supply and fix Modular switch , 1 Module single pole one way 10 Amps.
Supply and fix Modular switch , 1 Module single pole one way 16 Amps.
Supply and fix Modular bell push, 1 Module single pole one way 16 Amps.
Supply and fix Modular fan regulator, 2 Module120 Watt
Supply and fix modular socket , 2 Module 6 Amps 240 volts Ac 2/3 pin combined suitable for inserting 2 pin 5 Amps/ 3 pin 5 Amps plug top all as specified and directed at site.
Supply and fix modular socket , 2 Module 6/16 Amps 240 volts Ac 6 pin combined suitable for inserting 3 pin 6/16 Amps plug top all as specified and directed at site.
Supply and fix PVC ceiling rose 65 x 50 mm surface type with 3 terminals all as specified and directed.
Supply and fix Bell, AC, 230 volts, single pole all as specified and directed.
Supply and fix single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with single pole MCB 20 Amps 240 Volts AC
Supply and fix LED recess mounted luminaire suitable for 2x2 ft grid ceiling with system wattage of 36 watts , 3600 lumens, CCT 6500k , CRI > 80 , IP 20 , complete incl PVC sheathed 1.0 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting Make-CG of Catalogue No. LCTLRN-36-FO-CDL, or equivalent
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts , 100 Lumen/Watt, efficiency > 110, CCT 6500k , CRI > 80 , Wall / surface mounted , IP 20 aluminium etrusion housing complete with incl connecting up with PVC sheathed 1.0 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting Make- Havells cat no LHEXBTP7IN1S022 or equivalent
Supply & fix wall fans 230 volts single phase orbal high speed 450 mm sweep suitable for wall mounting. Make : Havell's, Model : Airboll Hi-speed or equivalent model of make USHA/Crompton/Khaitan as approved by GE.
Cutting holes into or through the stone walls built in cement mortar or cement lime mortar and walls of cement concrete suitable for housing 230mm dia exhaust fan using heavy duty stone drilling/cutter machine and making good the disturbed surface including provision of wire mesh with frame on the outer side of wall all as specified and directed.
Supply & fix exhaust fans of size 230mm sweep, AC single phase 230/ 240 V of metallic body with louver and other accessories complete all as specified and as directed. Make : Havell's , Model : Ventil Air - DB or equivalent model of make USHA/Crompton/Khaitan as approved by GE.
M/L for sub main wiring in repairs with Two single core PVC insulated cable with copper conductor multistranded 1100 volts grade 10.0 sqmm drawn through and including rigid, PVC coduit of suitable size, with all necessary fittings and accessories fixed on walls, floor or ceiling etc including 10.0sqmm PVC insulated unsheathed copper earth continuity conductor. Note : One run of PVC conduit and three runs of copper conductor together taken as one length for measuring unit length. Note : Three runs of copper conductor and one run of PVC conduit together taken as one length for measuring unit length.
M/L for sub main wiring in repairs with Two single core PVC insulated cable with copper conductor multistranded 1100 volts grade 6.0 sqmm drawn through and including rigid, PVC conduit of suitable size, with all necessary fittings and accessories fixed on walls, floor or ceiling etc including 6.0sqmm PVC insulated unsheathed copper earth continuity conductor. Note : One run of PVC conduit and three runs of copper conductor together taken as one length for measuring unit length. Note : Three runs of copper conductor and one run of PVC conduit together taken as one length for measuring unit length.
M/L for sub main wiring in repairs with Two single core PVC insulated cable with copper conductor multistranded 1100 volts grade 4.0 sqmm drawn through and including rigid, PVC conduit of suitable size, with all necessary fittings and accessories fixed on walls, floor or ceiling etc including 4.0sqmm PVC insulated unsheathed copper earth continuity conductor. Note : Three runs of copper conductor and one run of PVC conduit together taken as one length for measuring unit length.
M/L for sub main wiring in repairs wiring with Two single core PVC insulated cable with copper conductor multistranded 1100 volts grade 2.5 sqmm drawn through and including rigid, PVC conduit of suitable size, with all necessary fittings and accessories fixed on walls, floor or ceiling etc including 2.5sqmm PVC insulated unsheathed copper earth continuity conductor. Note : Three runs of copper conductor and one run of PVC conduit together taken as one length for measuring unit length.
Takingdown the smoke detector including fitting and fixture such as pipes, wiring etc for reuse at site or carrying to the store and refixing the same after complete the other maintenance work of the room all as specified and directed.
Supply and fixing air cooled split unit air conditioner electric driven,three phase of capacity of 3.0 TR,BEE 3 star rated. Make:-carrier Superia Mega 36K 3 star inverter AC with KW Display (3.0TR) or Equivalent as approved by GE.
S&F mild steel screw bolt (machine made with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed to be fitted with washer and one hexagonal nut, length of bolt exceeding 22.5 cm and not exceeding 30 cm long . Dia meter of neck is 16 to 20 mm.
Taking down the split AC of any capacity along with all accessories and refixing the same as specified and directed by the Engineer-in-charge. Note: Any extra accessories requried for fixing the AC shall be included in the quoted rate.
B.B. Enterprise
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .