Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAdmitted-Finance 6 NEW SADGURU NANIK INDUSTRIAL ESTATE OFF WESTERN EXPRESS HIGHWAY GOREGAON E MUMBAI 400063 INDIA | MUMBAI SUBURBAN | MAHARASHTRA | 400063 | ₹1.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.8 Cr+₹8.6 L (4.96%)Admitted-Finance | ₹1.8 Cr+₹8.6 L (4.96%) | L2 | Admitted-Finance |
| 3 | L3₹1.9 Cr+₹17.0 L (9.76%)Admitted-Finance 201 PLOT NO 32 SHALAKA BLDG TPS II JUHU ROAD SANTACRUZ WEST MUMBAI SUBURBAN MAHARASHTRA 400054 | MUMBAI SUBURBAN | MAHARASHTRA | 400054 | ₹1.9 Cr+₹17.0 L (9.76%) | L3 | Admitted-Finance |
| 4 | Not Admitted-Fee 241 SWAMI NARAYAN NAGAR 1 OPP SWAMIVIVEKANA ASHRAM BEHIND HALAR HOUSE JAMNAGAR JAMNAGAR GUJARAT 361001 | JAMNAGAR | GUJARAT | 361001 | - | - | Not Admitted-Fee EMD Exemption Certificate not received |
| 5 | Not Admitted-Fee | - | - | Not Admitted-Fee EMD Exemption Certificate not received |
| Sl No | Description | Qty | Unit | PREMIER ENGINEERING TECHNICS PVT. LTD. L1 | CHENNAI ENGINEERING SERVICES L2 | DElite System Engineering (India) Pvt. Ltd. L3 |
|---|---|---|---|---|---|---|
| 1.00SUB - HEAD - I - First Year (Man Power for Repair & Maintenance Works) | ||||||
| 1.01 | Facility management for all Internal and External Electrical installations at New Domestic Terminal Complex and its ancillary buildings etc. to ensure satisfactory serviceability through providing repair/maintenance services for all Internal & External Electrical installations involving repairs and maintenance of repair/replacement of circuit wiring, switches, breakers i/c providing consumable material like cotton waste, oil, grease, etc., & other sundry material required for cleaning at site etc. as required, including ensuring 100 % serviceability of EI installations in passenger movement area, preventive maintenance , maintenance of records / data entries and documentation including effective supervision etc. as per the detailed specifications, special conditions, terms and conditions covered under the tender clauses on round the clock 3 shifts basis on all days for including Sundays and holidays.
One Supervisor in General Shifts for 6 days in a week.
One Technician & One Helper in each of the A, B & C Shifts for All Days | 12 | Months | 1,97,970 ₹23,75,640 Lowest | 2,03,999 ₹24,47,988 | 2,06,399 ₹24,76,788 |
| 1.02 | Facility management for all Internal and External Electrical installations at New International Terminal Complex and its ancillary buildings etc. to ensure satisfactory serviceability through providing repair/maintenance services for all Internal & External Electrical installations involving repairs and maintenance of wiring, switches, breakers i/c providing consumable material like cotton waste, oil, grease, etc., & other sundry material required for cleaning at site etc. as required, including ensuring 100 % serviceability of EI installations in passenger movement area, preventive maintenance , maintenance of records / data entries and documentation including effective supervision etc. as per the detailed specifications, special conditions, terms and conditions covered under the tender clauses on round the clock 3 shifts basis on all days for including Sundays and holidays.
One Supervisor in General Shifts for 6 days in a week.
One Technician & One Helper in each of the A, B & C Shifts for All Days. | 12 | Months | 1,97,970 ₹23,75,640 Lowest | 2,03,999 ₹24,47,988 | 2,06,399 ₹24,76,788 |
| 2.00SUB - HEAD - II - First Year (Supply Portion) | ||||||
| 2.01 | Supply of 1.5 Sq.mm. X 3C Flexible Cable | 3,000 | Mtrs. | 39 ₹1,17,000 Lowest | 39 ₹1,17,000 Lowest | 49 ₹1,47,000 |
| 2.02 | Supply of 2.5 Sq.mm. X 3C Flexible Cable | 3,000 | Mtrs. | 63 ₹1,89,000 | 59 ₹1,77,000 Lowest | 79 ₹2,37,000 |
| 2.03 | Supply of 4 Sq.mm. X 3C Flexible Cable | 200 | Mtrs. | 94 ₹18,800 Lowest | 99 ₹19,800 | 102 ₹20,400 |
| 2.04 | Supply of 6 Sq.mm. X 4C Flexible Cable | 100 | Mtrs. | 176 ₹17,600 | 189 ₹18,900 | 149 ₹14,900 Lowest |
| 2.05 | Supply of 10 Sq.mm. X 3C Flexible Cable | 200 | Mtrs. | 226 ₹45,200 Lowest | 269 ₹53,800 | 249 ₹49,800 |
| 2.06 | Supply of XLPE insulated PVC sheathed armored Aluminum conductor power cable of 1.1 KV grade of 3.5C X 16 Sq.mm. | 200 | Mtrs. | 98 ₹19,600 Lowest | 99 ₹19,800 | 99 ₹19,800 |
Tender Value
₹2.1 Cr
EMD Value
₹4.2 L
Closing Date
1 Oct 2020, 6:00 pmClosed
JGM IT, Chennai Airport
Joint General Manager (IT), Information Technology Division, Project Office, Third Floor, Airport Metro Station, Airports Authority of India, Chennai Airport, Chennai 600027
AMC of Internal Electrical Network Installations at New Domestic and New International Terminals at Chennai Airport
2020_AAI_58277_1
AAI/CHN/IT/2020-21/04/IT-UPS
Open Tender
Information Technology
Works
1095 days
Chennai Airport
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,770
Yes
Airports Authority of India
₹4.2 L
Yes
14 Oct 2020
22 Sept 2020
6 Oct 2020
22 Sept 2020
1 Oct 2020
22 Sept 2020
22 Sept 2020 - 26 Sept 2020
Amount
SUB - HEAD - I - First Year (Man Power for Repair & Maintenance Works)
Facility management for all Internal and External Electrical installations at New Domestic Terminal Complex and its ancillary buildings etc. to ensure satisfactory serviceability through providing repair/maintenance services for all Internal & External Electrical installations involving repairs and maintenance of repair/replacement of circuit wiring, switches, breakers i/c providing consumable material like cotton waste, oil, grease, etc., & other sundry material required for cleaning at site etc. as required, including ensuring 100 % serviceability of EI installations in passenger movement area, preventive maintenance , maintenance of records / data entries and documentation including effective supervision etc. as per the detailed specifications, special conditions, terms and conditions covered under the tender clauses on round the clock 3 shifts basis on all days for including Sundays and holidays. One Supervisor in General Shifts for 6 days in a week. One Technician & One Helper in each of the A, B & C Shifts for All Days
Facility management for all Internal and External Electrical installations at New International Terminal Complex and its ancillary buildings etc. to ensure satisfactory serviceability through providing repair/maintenance services for all Internal & External Electrical installations involving repairs and maintenance of wiring, switches, breakers i/c providing consumable material like cotton waste, oil, grease, etc., & other sundry material required for cleaning at site etc. as required, including ensuring 100 % serviceability of EI installations in passenger movement area, preventive maintenance , maintenance of records / data entries and documentation including effective supervision etc. as per the detailed specifications, special conditions, terms and conditions covered under the tender clauses on round the clock 3 shifts basis on all days for including Sundays and holidays. One Supervisor in General Shifts for 6 days in a week. One Technician & One Helper in each of the A, B & C Shifts for All Days.
SUB - HEAD - II - First Year (Supply Portion)
Supply of 1.5 Sq.mm. X 3C Flexible Cable
Supply of 2.5 Sq.mm. X 3C Flexible Cable
Supply of 4 Sq.mm. X 3C Flexible Cable
Supply of 6 Sq.mm. X 4C Flexible Cable
Supply of 10 Sq.mm. X 3C Flexible Cable
Supply of XLPE insulated PVC sheathed armored Aluminum conductor power cable of 1.1 KV grade of 3.5C X 16 Sq.mm.
Supply of XLPE insulated PVC sheathed armored Aluminum conductor power cable of 1.1 KV grade of 3.5C X 25 Sq.mm.
Supply of XLPE insulated PVC sheathed armored Aluminum conductor power cable of 1.1 KV grade of 3.5C X 35 Sq.mm.
Providing 6 SWG dia G.I. wire for loop earthing along with existing surface / recessed conduit/ submain wiring / cable
Supply of Gland and Aluminium Lugs for following size of PVC insulated and PVC sheathed / XLPE armoured aluminium conductor cable of 1.1 KV grade a).3.5CX16SQMM
b).3.5CX25SQMM
c).3.5CX35SQMM
Supply of following size/ modules, PVC box alongwith modular base & cover plate for modular switches a) 3 Module (100 mm X 75 mm)
b) 6 Module (85 mm X 219 mm)
c) 9 Module (85 mm X 248 mm)
Supply of following modular switch/socket for fixing on the existing modular plate & switch box a) 10 Amps Switch
b) 10 Amps Socket Outlet
c) 20 Amps Switch
d) 10 & 20 Amps Socket Outlet
Supply of 6A to 32A SPN MCB C curve for the existing DB
Supply of 63 Amps MCB (2 Pole)
Supply of 63 Amps change over (MCB Type)
Supply of 63 Amps MCB 4 Pole
Supply of 63 Amps (Double pole ELCB)
Supply of 63A 25KA 4 pole MCCB for the existing DB
Supply of Single Phase 4 way upto 12 way DB Double Door SPN (Vertical Type) a). 4WAY
Supply of 3 Phase 4 way upto 12 way DB Double Door TPN (Vertical Type) a). 4WAY
Supply of 25 mm PVC casing & caping (1")
Supply of 25 mm PVC Flexible Hose Pipe (1")
Supply of 25 mm PVC Pipe (1'')
Supply of 5 Amps 3 Pin Plug Top
Supply of 15 Amps 3 Pin Plug Top
SUB - HEAD - III - First Year (Service Portion)
Laying of 1.5 Sq.mm. X 3C Flexible Cable
Laying of 2.5 Sq.mm. X 3C Flexible Cable
Laying of 4 Sq.mm. X 3C Flexible Cable
Laying of 6 Sq.mm. X 4C Flexible Cable
Laying of 10 Sq.mm. X 3C Flexible Cable
Laying of XLPE insulated PVC sheathed armored Aluminum conductor power cable of 1.1 KV grade of 3.5C X 16 Sq.mm.
Laying of XLPE insulated PVC sheathed armored Aluminum conductor power cable of 1.1 KV grade of 3.5C X 25 Sq.mm.
Laying of XLPE insulated PVC sheathed armored Aluminum conductor power cable of 1.1 KV grade of 3.5C X 35 Sq.mm.
Laying 6 SWG dia G.I. wire for loop earthing along with existing surface / recessed conduit/ submain wiring / cable
Making end termination with Gland and Aluminium Lugs for following size of PVC insulated and PVC sheathed / XLPE armoured aluminium conductor cable of 1.1 KV grade a) 3.5C x 16 Sq.mm. upto 35 Sq.mm.
Fixing of following size/ modules, PVC box alongwith modular base & cover plate for modular switches a) 3 Module (100 mm X 75 mm)
b) 6 Module (85 mm X 219 mm)
c) 9 Module (85 mm X 248 mm)
Fixing of following modular switch/socket for fixing on the existing modular plate & switch box a) 10 Amps Switch
b) 10 Amps Socket Outlet
c) 20 Amps Switch
d) 10 & 20 Amps Socket Outlet
Fixing of 6A to 32A SPN MCB C curve for the existing DB
Fixing of 63 Amps MCB (2 Pole)
Fixing of 63 Amps change over (MCB Type)
Fixing of 63 Amps MCB 4 Pole
Fixing of 63 Amps (Double pole ELCB)
Fixing of 63A 25KA 4 pole MCCB for the existing DB
Fixing of Single Phase 4 way upto 12 way DB Double Door SPN (Vertical Type)
Fixing of 3 Phase 4 way upto 12 way DB Double Door TPN (Vertical Type)
Laying of 25 mm PVC casing & caping (1")
Laying of 25 mm PVC Flexible (1'') Hose Pipe
Laying of 25 mm PVC Pipe (1'')
Fixing of 5 Amps 3 Pin Plug Top
Fixing of 15 Amps 3 Pin Plug Top
SUB - HEAD - IV - First Year (Man Power for Repair & Maintenance Works)
Facility management for all Internal and External Electrical installations at New Domestic Terminal Complex and its ancillary buildings etc. to ensure satisfactory serviceability through providing repair/maintenance services for all Internal & External Electrical installations involving repairs and maintenance of repair/replacement of circuit wiring, switches, breakers i/c providing consumable material like cotton waste, oil, grease, etc., & other sundry material required for cleaning at site etc. as required, including ensuring 100 % serviceability of EI installations in passenger movement area, preventive maintenance , maintenance of records / data entries and documentation including effective supervision etc. as per the detailed specifications, special conditions, terms and conditions covered under the tender clauses on round the clock 3 shifts basis on all days for including Sundays and holidays. One Supervisor in General Shifts for 6 days in a week. One Technician & One Helper in each of the A, B & C Shifts for All Days
Facility management for all Internal and External Electrical installations at New International Terminal Complex and its ancillary buildings etc. to ensure satisfactory serviceability through providing repair/maintenance services for all Internal & External Electrical installations involving repairs and maintenance of wiring, switches, breakers i/c providing consumable material like cotton waste, oil, grease, etc., & other sundry material required for cleaning at site etc. as required, including ensuring 100 % serviceability of EI installations in passenger movement area, preventive maintenance , maintenance of records / data entries and documentation including effective supervision etc. as per the detailed specifications, special conditions, terms and conditions covered under the tender clauses on round the clock 3 shifts basis on all days for including Sundays and holidays. One Supervisor in General Shifts for 6 days in a week. One Technician & One Helper in each of the A, B & C Shifts for All Days.
SUB - HEAD - V - First Year (Supply Portion)
Supply of 1.5 Sq.mm. X 3C Flexible Cable
Supply of 2.5 Sq.mm. X 3C Flexible Cable
Supply of 4 Sq.mm. X 3C Flexible Cable
Supply of 6 Sq.mm. X 4C Flexible Cable
Supply of 10 Sq.mm. X 3C Flexible Cable
Supply of XLPE insulated PVC sheathed armored Aluminum conductor power cable of 1.1 KV grade of 3.5C X 16 Sq.mm.
Supply of XLPE insulated PVC sheathed armored Aluminum conductor power cable of 1.1 KV grade of 3.5C X 25 Sq.mm.
Supply of XLPE insulated PVC sheathed armored Aluminum conductor power cable of 1.1 KV grade of 3.5C X 35 Sq.mm.
Providing 6 SWG dia G.I. wire for loop earthing along with existing surface / recessed conduit/ submain wiring / cable
Supply of Gland and Aluminium Lugs for following size of PVC insulated and PVC sheathed / XLPE armoured aluminium conductor cable of 1.1 KV grade a).3.5CX16SQMM
b).3.5CX25SQMM
c).3.5CX35SQMM
Supply of following size/ modules, PVC box alongwith modular base & cover plate for modular switches a) 3 Module (100 mm X 75 mm)
b) 6 Module (85 mm X 219 mm)
c) 9 Module (85 mm X 248 mm)
Supply of following modular switch/socket for fixing on the existing modular plate & switch box a) 10 Amps Switch
b) 10 Amps Socket Outlet
c) 20 Amps Switch
d) 10 & 20 Amps Socket Outlet
Supply of 6A to 32A SPN MCB C curve for the existing DB
Supply of 63 Amps MCB (2 Pole)
Supply of 63 Amps change over (MCB Type)
Supply of 63 Amps MCB 4 Pole
Supply of 63 Amps (Double pole ELCB)
Supply of 63A 25KA 4 pole MCCB for the existing DB
Supply of Single Phase 4 way upto 12 way DB Double Door SPN (Vertical Type) a). 4WAY
Supply of 3 Phase 4 way upto 12 way DB Double Door TPN (Vertical Type) a). 4WAY
Supply of 25 mm PVC casing & caping (1")
Supply of 25 mm PVC Flexible Hose Pipe (1")
Supply of 25 mm PVC Pipe (1'')
Supply of 5 Amps 3 Pin Plug Top
Supply of 15 Amps 3 Pin Plug Top
SUB - HEAD - VI - First Year (Service Portion)
Laying of 1.5 Sq.mm. X 3C Flexible Cable
Laying of 2.5 Sq.mm. X 3C Flexible Cable
Laying of 4 Sq.mm. X 3C Flexible Cable
Laying of 6 Sq.mm. X 4C Flexible Cable
Laying of 10 Sq.mm. X 3C Flexible Cable
Laying of XLPE insulated PVC sheathed armored Aluminum conductor power cable of 1.1 KV grade of 3.5C X 16 Sq.mm.
Laying of XLPE insulated PVC sheathed armored Aluminum conductor power cable of 1.1 KV grade of 3.5C X 25 Sq.mm.
Laying of XLPE insulated PVC sheathed armored Aluminum conductor power cable of 1.1 KV grade of 3.5C X 35 Sq.mm.
Laying 6 SWG dia G.I. wire for loop earthing along with existing surface / recessed conduit/ submain wiring / cable
Making end termination with Gland and Aluminium Lugs for following size of PVC insulated and PVC sheathed / XLPE armoured aluminium conductor cable of 1.1 KV grade a) 3.5C x 16 Sq.mm. upto 35 Sq.mm.
Fixing of following size/ modules, PVC box alongwith modular base & cover plate for modular switches a) 3 Module (100 mm X 75 mm)
b) 6 Module (85 mm X 219 mm)
c) 9 Module (85 mm X 248 mm)
Fixing of following modular switch/socket for fixing on the existing modular plate & switch box a) 10 Amps Switch
b) 10 Amps Socket Outlet
c) 20 Amps Switch
d) 10 & 20 Amps Socket Outlet
Fixing of 6A to 32A SPN MCB C curve for the existing DB
Fixing of 63 Amps MCB (2 Pole)
Fixing of 63 Amps change over (MCB Type)
Fixing of 63 Amps MCB 4 Pole
Fixing of 63 Amps (Double pole ELCB)
Fixing of 63A 25KA 4 pole MCCB for the existing DB
Fixing of Single Phase 4 way upto 12 way DB Double Door SPN (Vertical Type)
Fixing of 3 Phase 4 way upto 12 way DB Double Door TPN (Vertical Type)
Laying of 25 mm PVC casing & caping (1")
Laying of 25 mm PVC Flexible (1'') Hose Pipe
Laying of 25 mm PVC Pipe (1'')
Fixing of 5 Amps 3 Pin Plug Top
Fixing of 15 Amps 3 Pin Plug Top
SUB - HEAD - VII - Third Year (Man Power for Repair & Maintenance Works)
Facility management for all Internal and External Electrical installations at New Domestic Terminal Complex and its ancillary buildings etc. to ensure satisfactory serviceability through providing repair/maintenance services for all Internal & External Electrical installations involving repairs and maintenance of repair/replacement of circuit wiring, switches, breakers i/c providing consumable material like cotton waste, oil, grease, etc., & other sundry material required for cleaning at site etc. as required, including ensuring 100 % serviceability of EI installations in passenger movement area, preventive maintenance , maintenance of records / data entries and documentation including effective supervision etc. as per the detailed specifications, special conditions, terms and conditions covered under the tender clauses on round the clock 3 shifts basis on all days for including Sundays and holidays. One Supervisor in General Shifts for 6 days in a week. One Technician & One Helper in each of the A, B & C Shifts for All Days
Facility management for all Internal and External Electrical installations at New International Terminal Complex and its ancillary buildings etc. to ensure satisfactory serviceability through providing repair/maintenance services for all Internal & External Electrical installations involving repairs and maintenance of wiring, switches, breakers i/c providing consumable material like cotton waste, oil, grease, etc., & other sundry material required for cleaning at site etc. as required, including ensuring 100 % serviceability of EI installations in passenger movement area, preventive maintenance , maintenance of records / data entries and documentation including effective supervision etc. as per the detailed specifications, special conditions, terms and conditions covered under the tender clauses on round the clock 3 shifts basis on all days for including Sundays and holidays. One Supervisor in General Shifts for 6 days in a week. One Technician & One Helper in each of the A, B & C Shifts for All Days.
SUB - HEAD - VIII - Third Year (Supply Portion)
Supply of 1.5 Sq.mm. X 3C Flexible Cable
Supply of 2.5 Sq.mm. X 3C Flexible Cable
Supply of 4 Sq.mm. X 3C Flexible Cable
Supply of 6 Sq.mm. X 4C Flexible Cable
Supply of 10 Sq.mm. X 3C Flexible Cable
Supply of XLPE insulated PVC sheathed armored Aluminum conductor power cable of 1.1 KV grade of 3.5C X 16 Sq.mm.
Supply of XLPE insulated PVC sheathed armored Aluminum conductor power cable of 1.1 KV grade of 3.5C X 25 Sq.mm.
Supply of XLPE insulated PVC sheathed armored Aluminum conductor power cable of 1.1 KV grade of 3.5C X 35 Sq.mm.
Providing 6 SWG dia G.I. wire for loop earthing along with existing surface / recessed conduit/ submain wiring / cable
Supply of Gland and Aluminium Lugs for following size of PVC insulated and PVC sheathed / XLPE armoured aluminium conductor cable of 1.1 KV grade a).3.5CX16SQMM
b).3.5CX25SQMM
c).3.5CX35SQMM
Supply of following size/ modules, PVC box alongwith modular base & cover plate for modular switches a) 3 Module (100 mm X 75 mm)
b) 6 Module (85 mm X 219 mm)
c) 9 Module (85 mm X 248 mm)
Supply of following modular switch/socket for fixing on the existing modular plate & switch box a) 10 Amps Switch
b) 10 Amps Socket Outlet
c) 20 Amps Switch
d) 10 & 20 Amps Socket Outlet
Supply of 6A to 32A SPN MCB C curve for the existing DB
Supply of 63 Amps MCB (2 Pole)
Supply of 63 Amps change over (MCB Type)
Supply of 63 Amps MCB 4 Pole
Supply of 63 Amps (Double pole ELCB)
Supply of 63A 25KA 4 pole MCCB for the existing DB
Supply of Single Phase 4 way upto 12 way DB Double Door SPN (Vertical Type) a). 4WAY
Supply of 3 Phase 4 way upto 12 way DB Double Door TPN (Vertical Type) a). 4WAY
Supply of 25 mm PVC casing & caping (1")
Supply of 25 mm PVC Flexible Hose Pipe (1")
Supply of 25 mm PVC Pipe (1'')
Supply of 5 Amps 3 Pin Plug Top
Supply of 15 Amps 3 Pin Plug Top
SUB - HEAD - IX - Third Year (Service Portion)
Laying of 1.5 Sq.mm. X 3C Flexible Cable
Laying of 2.5 Sq.mm. X 3C Flexible Cable
Laying of 4 Sq.mm. X 3C Flexible Cable
Laying of 6 Sq.mm. X 4C Flexible Cable
Laying of 10 Sq.mm. X 3C Flexible Cable
Laying of XLPE insulated PVC sheathed armored Aluminum conductor power cable of 1.1 KV grade of 3.5C X 16 Sq.mm.
Laying of XLPE insulated PVC sheathed armored Aluminum conductor power cable of 1.1 KV grade of 3.5C X 25 Sq.mm.
Laying of XLPE insulated PVC sheathed armored Aluminum conductor power cable of 1.1 KV grade of 3.5C X 35 Sq.mm.
Laying 6 SWG dia G.I. wire for loop earthing along with existing surface / recessed conduit/ submain wiring / cable
Making end termination with Gland and Aluminium Lugs for following size of PVC insulated and PVC sheathed / XLPE armoured aluminium conductor cable of 1.1 KV grade a) 3.5C x 16 Sq.mm. upto 35 Sq.mm.
Fixing of following size/ modules, PVC box alongwith modular base & cover plate for modular switches a) 3 Module (100 mm X 75 mm)
b) 6 Module (85 mm X 219 mm)
c) 9 Module (85 mm X 248 mm)
Fixing of following modular switch/socket for fixing on the existing modular plate & switch box a) 10 Amps Switch
b) 10 Amps Socket Outlet
c) 20 Amps Switch
d) 10 & 20 Amps Socket Outlet
Fixing of 6A to 32A SPN MCB C curve for the existing DB
Fixing of 63 Amps MCB (2 Pole)
Fixing of 63 Amps change over (MCB Type)
Fixing of 63 Amps MCB 4 Pole
Fixing of 63 Amps (Double pole ELCB)
Fixing of 63A 25KA 4 pole MCCB for the existing DB
Fixing of Single Phase 4 way upto 12 way DB Double Door SPN (Vertical Type)
Fixing of 3 Phase 4 way upto 12 way DB Double Door TPN (Vertical Type)
Laying of 25 mm PVC casing & caping (1")
Laying of 25 mm PVC Flexible (1'') Hose Pipe
Laying of 25 mm PVC Pipe (1'')
Fixing of 5 Amps 3 Pin Plug Top
Fixing of 15 Amps 3 Pin Plug Top
CHENNAI ENGINEERING SERVICES
DElite System Engineering (India) Pvt. Ltd.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.21 MB
Tender.pdf
Tender Documents • 2.04 MB
BOQ_62703.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .