Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 CrAdmitted-Finance | ₹2.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.5 CrAdmitted-Finance | ₹2.5 Cr | L2 | Admitted-Finance |
| 3 | L3₹2.6 CrAdmitted-Finance 0 S F ENTERPRISES CHANDAK CHANDAK POONCH POONCH JAMMU KASHMIR 185101 UDYAM JK 14 0008974 | POONCH | JAMMU AND KASHMIR | 185101 | ₹2.6 Cr | L3 | Admitted-Finance |
| 4 | L4₹2.7 CrAdmitted-Finance 1ST FLOOR HRECF OFFICE NEAR JNV SCHOOL MIAN GATE TIA RAY RONG CHOGLAMSAR LEH LADAKH 194101 UDYAM LA 02 0000410 | LEH LADAKH | LADAKH | 194101 | ₹2.7 Cr | L4 | Admitted-Finance |
| 5 | L5₹2.9 CrAdmitted-Finance | ₹2.9 Cr | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S VEENA CONSTRUCTION COMPANY L2 | HIMALAYAN RENEWABLE ENERGY AND CONSTRUCTION FIRM (HRECF) L4 | M/s Cee Kay Traders L1 | M/S CHHEIRPON ENTERPRISES L5 | M/s S. F. ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00DT ( Supply Part ) | ||||||||
| 1.01 | Supply of 250KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate | 7 | No. | 7,00,000 ₹49 L | 5,20,000 ₹36.4 L | 7,50,000 ₹52.5 L | 4,90,000 ₹34.3 L | 7,00,000 ₹49 L |
| 1.02 | Supply of 100KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate | 9 | No. | 2,70,000 ₹24.3 L | 2,35,000 ₹21.1 L | 4,00,000 ₹36 L | 2,75,000 ₹24.8 L | 3,50,000 ₹31.5 L |
| 1.03 | Supply of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type | 16 | Set | 5,000 ₹80,000 | 11,100 ₹1.8 L | 3,450 ₹55,200 | 15,100 ₹2.4 L | 3,750 ₹60,000 |
| 1.04 | Supply of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp,Vertical Type | 16 | Set | 8,500 ₹1.4 L | 14,000 ₹2.2 L | 6,750 ₹1.1 L | 14,000 ₹2.2 L | 10,500 ₹1.7 L |
| 1.05 | Supply of 11 kV Horn Gap Fuse Set 3 Phase 200A | 16 | Set | 5,000 ₹80,000 | 9,000 ₹1.4 L | 2,900 ₹46,400 | 9,000 ₹1.4 L | 4,000 ₹64,000 |
| 1.06 | Supply of 185mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 100kva DTs | 308 | Mtr | 350 ₹1.1 L | 900 ₹2.8 L | 1,650 ₹5.1 L | 900 ₹2.8 L | 750 ₹2.3 L |
| 1.07 | Supply of 120mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 63kva DTs | 396 | Mtr | 280 ₹1.1 L | 600 ₹2.4 L | 1,100 ₹4.4 L | 600 ₹2.4 L | 650 ₹2.6 L |
| 1.08 | Supply of 9 Mtr. Long Pole,ST-410 SP33) | 32 | Nos | 22,000 ₹7.0 L | 23,000 ₹7.4 L | 24,000 ₹7.7 L | 25,000 ₹8 L | 22,000 ₹7.0 L |
| 1.09 | Supply of 33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm | 48 | Nos | 650 ₹31,200 | 550 ₹26,400 | 450 ₹21,600 | 550 ₹26,400 | 900 ₹43,200 |
Tender Value
₹5,000
EMD Value
₹7.2 L
Closing Date
18 Nov 2025, 2:00 pmClosed
Chief Enginner Distrbution Wing Ladakh
PDD Choglamsar
same as above
2025_PDNRE_17940_1
e-NIT No. 147 of ED Leh of 2025-26 dated 10-11-2025
Open Tender
Electrical Works
365 days
Leh
Please refer Tender documents.
6 documents required · 6 mandatory
₹5,000
Payable To Executive Engineer EDD Leh
₹7.2 L
9 Dec 2025
10 Nov 2025
19 Nov 2025
10 Nov 2025
18 Nov 2025
11 Nov 2025
Amount
DT ( Supply Part )
Supply of 250KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
Supply of 100KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
Supply of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
Supply of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp,Vertical Type
Supply of 11 kV Horn Gap Fuse Set 3 Phase 200A
Supply of 185mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 100kva DTs
Supply of 120mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 63kva DTs
Supply of 9 Mtr. Long Pole,ST-410 SP33)
Supply of 33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply of GI Channel/Angle/Flat of sizes including clamps
Supply of Galvinized Nuts and Bolts.
Supply of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Supply of 33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply of LT Distribution Box for 250 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 120Amp and suitable MCCBs for outgoing circuits with terminal extensions
Supply of LT Distribution Box for 100 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 120Amp and suitable MCCBs for outgoing circuits with terminal extensions
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Supply of Danger Plates with Clamps
Supply of GI Barbed Wire for Anti Climbing
Supply of 3-Ø, 4-Wire Trivector Meter with CT(LTCT AMR compatible)
Supply of Cement bottoming 1:2:4 mix as per REC standards .5cum/pole
Supply of Painting of Poles Red Oxide
Supply of Painting of Poles Aluminium Paint
Supply of Sundry items like aluminium lugs, Jumpers, binding Tape,
Transformer Fencing
Installation/Testing /Commissioning Part of Substation.
250KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
100KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
185mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 100kva DTs
120mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 63kva DTs
9 Mtr. Long Pole,ST-410 SP33)
3kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
LT Distribution Box for 250 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 120Amp and suitable MCCBs for outgoing circuits with terminal extensions
LT Distribution Box for 100 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 120Amp and suitable MCCBs for outgoing circuits with terminal extensions
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
3-Ø, 4-Wire Trivector Meter with CT(LTCT AMR compatible)
Cement bottoming 1:2:4 mix as per REC standards .5cum/pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry items like aluminium lugs, Jumpers, binding Tape,
Transformer Fencing
HT Line Supply Part
9 Mtr. Long Pole( ST-410 SP33)
GI V cross-arm with top Bracket including clamp(14.631 kg)
GI Channel X-Arm 1600mm long including clamps and braces (75x40x6mm) GI Channel (weight per channel = 11.42kg, back clamp for cantilever 50x8mm, 365mm long = 1.15kg Total weight = 12.57kg/Channel +Clamp) GI Angle 65x65x6mm, 1760mm long including clamps and braces in kgs (weight = 10.21kg, Guy clamp for cantilever 50x8mm, 300mm long = 0.9kg, Total weight = 11.11kg) Total weight = 23.68Kg
GI Channel including clamps,fish plate and braces(80 KG)
30 mm² ACSR Conductor
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative,(Double Disc on a Frame)creepage distance 320mm
Galvinized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards .45cum /pole
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp,Vertical Type
HT Line Installation/Testing /Commissioning Part
9 Mtr. Long Pole( ST-410 SP33)
GI V cross-arm with top Bracket including clamp(14.631 kg)
GI Channel X-Arm 1600mm long including clamps and braces (75x40x6mm) GI Channel (weight per channel = 11.42kg, back clamp for cantilever 50x8mm, 365mm long = 1.15kg Total weight = 12.57kg/Channel +Clamp) GI Angle 65x65x6mm, 1760mm long including clamps and braces in kgs (weight = 10.21kg, Guy clamp for cantilever 50x8mm, 300mm long = 0.9kg, Total weight = 11.11kg) Total weight = 23.68Kg
GI Channel including clamps,fish plate and braces(80 KG)
30 mm² ACSR Conductor
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative,(Double Disc on a Frame) creepage distance 320mm
Galvinized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards .45cum /pole
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp,Vertical Type
LT Line Supply Part
8 Mtr. Long Pole,ST-410 SP15)
GI Channel X ARM (75X40X6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8Kg, 1 No. clamp=0.83Kg = total weight = 8.83 kg)
120sqmm LT AB Cable (3x120+1x16+70sqmm) XLPE unarmoured FRLS Type
SMDP Box
35sqmm 1 Core Cable 1.1KV Grade XLPE unarmoured RRLS Type
IPC Connector
Tension Clamps
Suspension Clamps
Suspension hook (eye hook)
30mm² ACSR Conductor
Galvinized Nuts and Bolts.
16kN Polymer Shackle Insulators
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
LT Line Installation/Testing /Commissioning Part
8 Mtr. Long Pole,ST-410 SP15)
GI Channel X ARM (75X40X6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8Kg, 1 No. clamp=0.83Kg = total weight = 8.83 kg)
120sqmm LT AB Cable (3x120+1x16+70sqmm) XLPE unarmoured FRLS Type
SMDP Box
35sqmm 1 Core Cable 1.1KV Grade XLPE unarmoured RRLS Type
IPC Connector
Tension Clamps
Suspension Clamps
Suspension hook (eye hook)
30mm² ACSR Conductor
Galvinized Nuts and Bolts.
16kN Polymer Shackle Insulators
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
M/S VEENA CONSTRUCTION COMPANY (BID ID -174264)
M/s S. F. ENTERPRISES (BID ID -174296)
HIMALAYAN RENEWABLE ENERGY AND CONSTRUCTION FIRM (HRECF) (BID ID -174290)
M/S CHHEIRPON ENTERPRISES (BID ID -174293)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.07 MB
Tendernotice_2.pdf
PDF • 1.13 MB
Tendernotice_3.pdf
PDF • 0.98 MB
Tendernotice_4.pdf
PDF • 0.35 MB
Tendernotice_5.pdf
PDF • 7.20 MB
Tendernotice_6.pdf
PDF • 1.37 MB
BOQ_43456.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid