The Executive Engineer PWD,ECD
New office Complex Building(5th Floor) Bhabani Bhawan Alipore, Kolkata 700027
Replacement of old HPSV type street light fittings and MH type flood lights to LED light fittings at the compound of West Bengal Board for Technicians Studio.
2026_WBPWD_5014370_1
WBPWD/EE-ECD/e-NIQ-10/2026-27
Open Tender
ELECTRICAL WORKS ORG
60 days
Alipore
please refer tender documents
5 documents required · 5 mandatory
₹17,238
O/O The Executive Engineer PWD ECD
21 May 2026
21 May 2026
12 Jun 2026
21 May 2026
10 Jun 2026
3 Jun 2026
21 May 2026 - 1 Jun 2026
1 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Disconnection & dismantling existing old fittings and clearing/removing from the site and deposit the same to the authority as directed by EIC. (considering 1 no semi-skilled & 1 no helper for 1 day) | 1 | Item | 1.25 | ₹1.25 | text01 |
Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body finish with corrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driver efficiency >80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 50o C and working RH 10% - 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L,N,E as per IEC 61000-4-5. The driver rated output wattage should be 10% to 15% higher than lamp rating and at least 2 driver for 200W & above and Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 , P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, under voltage and over voltage protection, high efficiency lens with type II/III distribution as required with UV stabilized optical lens, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends. CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect and LED Chips of SMD mid to high-power (2.5 to 4 watt for 200 watt and above, as per required (LM- 80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (System lumen efficacy ≥135 lm/Watt) (Make: Signify / Crompton / Wipro) | - | - | - | - | text02 | |
150 watt | 55 | Nos | 1.25 | ₹68.75 | text03 | |
Supplying, installation, Testing & Commissioning of Flood light LED fixture powder coated pressure die cast aluminum body finish with corrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driverefficiency >80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 50o C and working RH 10% - 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L,N,E as per IEC 61000-4-5. The driver rated output wattage should be 10% to 15% higher than lamp rating and at least 2 driver for 200W & above and Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 , P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, under voltage and over voltage protection, high efficiency lens with type II/III distribution as required with UV stabilized optical lens, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends. CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect and LED Chips of SMD mid to high-power (2.5 to 4 watt for 200 watt and above, as per required (LM- 80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (System lumen efficacy ≥135 lm/Watt.) (Make: Signify / Crompton / Wipro) | - | - | - | - | text04 | |
150 Watt | 26 | Nos | 1.25 | ₹32.5 | text05 | |
| 4 | Fixing only Street/Flood Light Fitting on wall/ceiling by screws etc with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure. | 81 | Nos. | 1.25 | ₹101.25 | text06 |
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Gloster/Finolex/Havells/Polycab/RR Kabel) of the following sizes with polythene pipe(19mm dia 3mm thick) and GI fish wire and making necy. connection as required | - | - | - | - | text07 | |
i) 3x22/0.3(1.5sqmm) | 240 | Mtr | 1.25 | ₹300 | text08 | |
| 6 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works | - | - | - | - | text09 |
i) 20mm size | 200 | Mtr | 1.25 | ₹250 | text10 |