Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAdmitted-Finance | ₹1.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.0 Cr+₹50.0 L (33.1%)Admitted-Finance | ₹2.0 Cr+₹50.0 L (33.1%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Saurabh Enterprises L1 | R S ELECTRICAL L2 |
|---|---|---|---|---|---|
| 1.00 | Supply , Installation, Testing & Commissioning of LED Street Light fitting with mandatory driver set having die cast aluminium body and lenses suitable for 45 watt and (Conforming to IP 65/IP66 protection and IS -16103-2012 with amendments, if any or equivalent), as per direction of engineer-in- charge | 190 | each | 5,000 ₹9,50,000 | 2,400 ₹4,56,000 Lowest |
| 2.00 | Supply , Installation, Testing & Commissioning of LED Street Light fitting with mandatory driver set having die cast aluminium body and lenses suitable for 90 watt and (Conforming to IP 65/IP66 protection and IS -16103-2012 with amendments,if any or equivalent), as per direction of engineer-in- charge | 8 | each | 6,000 ₹48,000 | 4,200 ₹33,600 Lowest |
| 3.00 | Supply , Installation, Testing & Commissioning of integral well glass luminaire compressed of dia cast canopy gear box housing and glass driver surge with heat resistance glass of LED well glass fitting 35 to 40 watt, 110 Lm/watt to 125 Lm/watt or Luminous should not be less than 4200 as per direction of engineer in charge (Conforming to IS -16103-2012 with amendments,if any or equivalent) | 754 | each | 2,464 ₹18,57,856 Lowest | 4,100 ₹30,91,400 |
| 4.00 | Supplying and fixing of 32 mm dia X 2.00 meters long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.(conforming to IS-1239 part 1 (2004) or equivalent) | 199 | each | 500 ₹99,500 Lowest | 900 ₹1,79,100 |
| 5.00 | Supply , Installation, Testing & Commissioning of loop in loop out box made of PVC sheet 200x 150x100 mm having suitable size 2 nos. terminals and 1 no. SP MCB 5A detachable gland plate, interconnection etc. are required (Conforming to relevant BIS/IS standard or equivalent) | 409 | each | 500 ₹2,04,500 Lowest | 1,500 ₹6,13,500 |
| 6.00Supply of PVC insulated PVC sheathed cable of 1.1KV grade armoured Underground aluminum conductor cable as reqd confirming to IS –7098 part I with up to date amendments) of the following size. | |||||
| 6.01 | 2x6 sqmm | 931 | Mtr. | 150 ₹1,39,650 | 110 ₹1,02,410 Lowest |
| 6.02 | 2x10 sqmm | 7,700 | Mtr. | 220 ₹16,94,000 | 140 ₹10,78,000 Lowest |
| 6.03 | 4x10 sqmm | 210 | Mtr. | 220 ₹46,200 | 180 ₹37,800 Lowest |
| 6.04 | 4x16 sqmm | 1,066 | Mtr. | 230 ₹2,45,180 | 200 ₹2,13,200 Lowest |
Tender Value
₹2.4 Cr
EMD Value
₹4.8 L
Closing Date
9 Dec 2022, 2:00 pmClosed
AGM EM
TC 3V Vibhuti Khand Lucknow
Improvement of Electrical Installation and lighting arrangement by replacement with LED lights at FSD Chandari under DO Kanpur
2022_FCI_724438_1
EM/16/2022-23
Open Tender
Electrical Works
Item Rate
180 days
FSD Chandari kanpur
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹4.8 L
24 Apr 2023
19 Nov 2022
10 Dec 2022
19 Nov 2022
9 Dec 2022
19 Nov 2022
Amount
Supply , Installation, Testing & Commissioning of LED Street Light fitting with mandatory driver set having die cast aluminium body and lenses suitable for 45 watt and (Conforming to IP 65/IP66 protection and IS -16103-2012 with amendments, if any or equivalent), as per direction of engineer-in- charge
Supply , Installation, Testing & Commissioning of LED Street Light fitting with mandatory driver set having die cast aluminium body and lenses suitable for 90 watt and (Conforming to IP 65/IP66 protection and IS -16103-2012 with amendments,if any or equivalent), as per direction of engineer-in- charge
Supply , Installation, Testing & Commissioning of integral well glass luminaire compressed of dia cast canopy gear box housing and glass driver surge with heat resistance glass of LED well glass fitting 35 to 40 watt, 110 Lm/watt to 125 Lm/watt or Luminous should not be less than 4200 as per direction of engineer in charge (Conforming to IS -16103-2012 with amendments,if any or equivalent)
Supplying and fixing of 32 mm dia X 2.00 meters long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.(conforming to IS-1239 part 1 (2004) or equivalent)
Supply , Installation, Testing & Commissioning of loop in loop out box made of PVC sheet 200x 150x100 mm having suitable size 2 nos. terminals and 1 no. SP MCB 5A detachable gland plate, interconnection etc. are required (Conforming to relevant BIS/IS standard or equivalent)
Supply of PVC insulated PVC sheathed cable of 1.1KV grade armoured Underground aluminum conductor cable as reqd confirming to IS –7098 part I with up to date amendments) of the following size.
2x6 sqmm
2x10 sqmm
4x10 sqmm
4x16 sqmm
3.5 x 35 sqmm
Dismantling and refixing of steel conduit along with all accessories in surface/recess including painting etc. in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.(conforming to IS-9537 Part 3 or equivalent with upto date amendments)25 mm
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. (conforming to relevant BIS/IS codes)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.(conforming to IS-694-2010 or equivalent with upto date amendments)
3x2.5sqmm
3x1.5sqmm
5x1.5sqmm
Supplying of 18 to 22 watt LED tube fitting as per direction of engineer-In-Charge (conforming to IS-16103 part 2 (2012) with upto date amendments or equivalent)
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. (conforming to IS 14772 (2000) with upto date amendments or equivalent)200mm x 150mm x 75 mm deep
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc as required .(conforming to IS 3854:1997 with upto date amendments or equivalent)5/6 Amp Switch
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 kv grade as required.(conforming to IS 12943 (1990) with upto date amendments or equivalent)
2 X 6 sqmm (19mm)
2 X 10 sqmm (19mm)
4 X 10 sq. mm (25mm)
4 X 16 sq. mm (28mm)
3.5 x 35 sqmm (32mm)
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.(conforming to IS 13032, IS 8623 with upto date amendments or equivalent)
Earthing with G.I. earth pipe 4.5-meter-long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (Conforming to relevant BIS/IS standard or equivalent)
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.(Conforming to relevant BIS/IS standard or equivalent)
Supplying and fixing Combined Unit Box with 16A Switch & 6pin 16A Socket including connections, painting etc. as required. (conforming to IS 3854:1997 & IS 1293:2019 with upto date amendments or equivalent)
Supplying and fixing of light class G.I. pipe of 50 mm dia.(nominal) 3metres length along the pole for protection of underground cable as required conforming to IS-1239 Part-1(2004) or equivalent with upto date amendments.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal)
Supply of PVC sheathed L.T. ABC Cable of 1.1 KV Grade Al Conductor cable as reqd as per IS-14255 3X70 + 1X16 + 1X50 sqmm
Supply of accessories for erection of ABC Cable(Conforming to relevant BIS/IS standard or equivalent)
Supply of ABC clamp
Supply of ABC hook
Supply of Suspension Clamp
Supply of Ded Clamp
Supply of PG connector
Supply of PG Clamp
Erection of ABC Cable on existing poles including fixing accessories as reqd.
S/I/T/C of weather proof 3 phase SMC MOULDED SERVICE CONNECTION BOARDS / Busbar box for AB Cables with pole mounting arrangement, with cable entry from bottom or sides and Busbar for high fault currents(Conforming to relevant BIS/IS standard or equivalent)
Supplying , installation , testing and commissioning of cubical type,inverted V shaped top, outdoor feeder pillar panel with size (1.0x1.0x.4 Mtr) suitable for operation at 415 (+/-) 6% Volts,50Hz,3 Phase 4 Wire system made out from CRCA sheet steel 2.0 mm and covers shall be cold rolled sheet thickness not less than 1.6mm fabricated factory finished followed-42 by powder coated painting & provided with gaskit etc. to make dust & vermin proof degree of IP ,Weather Proof, hinged type openable door , loaking arrangement , detachable gland plate , connection , interconnections with suitable size (150 Amp capacity) 4 strip high conductivity electrical aluminium (ALU) busbar codifies in red,yellow,blue and black colour and PVC insulated copper conductor cable 1100Volt grade for internal wiring including providing and fixing digital type Ampere meter, Voltmeter, Indication LED lamp, ,Labeling comprise white letters on black background including foundation works etc. as required (Conforming to relevant BIS/IS standard or equivalent) with following:- 1) 4P MCCB 100Amps,36KA-01No 2) 4P MCCB 63 Amps.25KA-04 Nos 3) MCB DP 32 Amps -02 Nos 4) TPN MCB 32Amp-02 Nos 5) 4 strip AL Busbar 150Amp- 01 Set
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required conforming to relevant BIS/IS codes. Group A
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (Conforming to relevant BIS/IS standard or equivalent)
6 Module (200mmX75mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(Conforming to relevant BIS/IS standard or equivalent)
5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Supply of steel Tubular pole 8.5 to 9.00 mt 410/SP.-29(Conforming to IS 2713 (PART I TO III) : 1980 or equivalent with upto date amendments )
Erection of metallic pole of following length in cement concrete 1:3:6(1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.Above 8.0 metre and upto 10.0 metre
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.
Upto 35 sq. mm
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Dismantling of overhead lines comprising of copper/ aluminium overhead conductor, G.I. wire, cross arms, insulators etc. as required.
Credit of old dismantled / scrap items
Aluminium Scrap ( i.e., Cables etc.)(L.S.)
Iron Scrap (Steel tubular poles, dismantled iron conduits etc.)(L.S.)
Copper Scrap (old wires, HPSV ballast etc.)(L.S.)
R S ELECTRICAL
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.72 MB
FSDChandariImprovementMTFFinal.pdf
Tender Documents • 1.48 MB
BOQ_761913.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .