| 1 | L1₹9.2 CrAdmitted-Finance | ₹9.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹9.5 Cr+₹28.4 L (3.07%)Admitted-Finance INFINITY THINK TANK TOWER II 10TH FLOOR PLOT NO A3 BLOCK G SECTOR V SALT LAKE CITY KOLKATA 700091 WB | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹9.5 Cr+₹28.4 L (3.07%) | L2 | Admitted-Finance |
| 3 | L3₹9.8 Cr+₹57.7 L (6.24%)Admitted-Finance 3RD T N TOWER A T ROAD PALTAN BAZAR KAMRUP METROPOLITAN KAMRUP ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | ₹9.8 Cr+₹57.7 L (6.24%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | techno power enterprises private limited L2 | RAUSHEENA UDYOG LIMITED L3 | M/S. EASTERN TRADERS L1 |
|---|---|---|---|---|---|---|
| 1.00A. Supply of Materials for Construction of 33 KV Line | ||||||
| 1.01 | ACSR Mink 6/1/3.66 mm | 37.2 | Km | 83,708.8 ₹31,13,967.36 | 86,236.8 ₹32,08,008.96 | 81,254.9 ₹30,22,682.28 Lowest |
| 1.02 | Steel tubular pole SP 45 (Half-Galvanised) | 144 | No | 26,521.11 ₹38,19,039.84 | 27,436 ₹39,50,784 | 25,636.65 ₹36,91,677.6 Lowest |
| 1.03 | 70 KM Ball & Socket (B&S) Type 11 kV Disc Insulator, complete | 1,116 | No | 1,114.62 ₹12,43,915.92 | 1,166.2 ₹13,01,479.2 | 1,065.25 ₹11,88,819 Lowest |
| 1.04 | Hardware fittings for B&S Disc Insulator, complete | 396 | No | 447.74 ₹1,77,305.04 | 459.3 ₹1,81,882.8 | 436.44 ₹1,72,830.24 Lowest |
| 1.05 | 33 kV Pin Insulator, complete with GI pin | 252 | No | 906.9 ₹2,28,538.8 | 939.5 ₹2,36,754 | 875.42 ₹2,20,605.84 Lowest |
| 1.06 | MS Channel 100x50x6 mm for X-arm, 27.6 kg per channel | 3,974.4 | Kg | 153.89 ₹6,11,620.42 | 160.6 ₹6,38,288.64 | 147.46 ₹5,86,065.02 Lowest |
| 1.07 | 3.5 Mtr length weighing 12.25 kg for disgonal member | 1,476 | Kg | 152.24 ₹2,24,706.24 | 157.1 ₹2,31,879.6 | 147.46 ₹2,17,650.96 Lowest |
| 1.08 | 2.5 Mtr length weighing 8.75 kg for horizontal member | 1,056 | Kg | 151.03 ₹1,59,487.68 | 154.6 ₹1,63,257.6 | 147.46 ₹1,55,717.76 Lowest |
| 1.09 | Guard Bracket | 540 | Kg | 155.47 ₹83,953.8 | 163.9 ₹88,506 | 147.46 ₹79,628.4 Lowest |
Tender Value
Refer Docs
EMD Value
₹9.5 L
Closing Date
25 Mar 2025, 11:00 amClosed
Chief Engineer (D and R)
Office of Chief Engineer (D and R)
Construction of 33 kV Line from Sangsangnyu to Tobu and 33/11 kV, 2.5 MVA Sub-station at Tobu under Mon.
2025_DP_750_1
NO. CEL/DnR/D1/73/LoA-Plan 2024-25/3034
Open Tender
Electrical Works
Turn-key
365 days
Nagaland
Refer Tender Documents
3 documents required · 3 mandatory
₹25,000
Chief Engineer (D and R)
₹9.5 L
25 Mar 2025
14 Mar 2025
25 Mar 2025
14 Mar 2025
25 Mar 2025
17 Mar 2025
Amount
A. Supply of Materials for Construction of 33 KV Line
ACSR Mink 6/1/3.66 mm
Steel tubular pole SP 45 (Half-Galvanised)
70 KM Ball & Socket (B&S) Type 11 kV Disc Insulator, complete
Hardware fittings for B&S Disc Insulator, complete
33 kV Pin Insulator, complete with GI pin
MS Channel 100x50x6 mm for X-arm, 27.6 kg per channel
3.5 Mtr length weighing 12.25 kg for disgonal member
2.5 Mtr length weighing 8.75 kg for horizontal member
Guard Bracket
Stay set 19 mm dia. 1.6 Mtr length with stay rod and bow plate
GI Stay wire 7/10 SWG weighing 43.4 kg per 100 mtr coil. 12 mtr per stay
Danger plate for 33 kv
MS Double Clamp 4.5" (115 mm) dia (top)
MS Single Clamp 4.5" (115 mm) dia (top)
MS Single Clamp 5.5" (140 mm) dia (middle)
GI Nuts & Bolts 5/8" x 3" (16x75 mm)
GI Nuts & Bolts 5/8" x 3" (16x200 mm)
GI Washers 5/8" x 3" (18 mm dia for 16 mm bolts)
B. Supply of Materials for Construction of 2.5 MVA Sub-Station
Structure for 33KV and 11KV bay
GI Steel Tubular Pole SP 76 (33KV bay- 4 nos, 11KV bay 6 nos )
GI MS Channel 100x50x6mm for cross arm and support of equipment - 2.2 M Long weighing 20.24 kg each (Galvanised)
GI M.S Angle 50x50x6x5000 mm each weighing 22.5 Kg (Galvanised)
Pole Double Clamp of G.I flat 50x6 mm
GI Nuts & Bolts with washer ( Assorted sizes including through bolt)
33KV SIDE EQUIPMENT
33KV VCB
33 kV SF6 circuit breaker, 3-Ph (out-door type ) complete
CURRENT TRANSFORMER (METERING AND PROTECTION)
INCOMING
Supply of 33kv, single pole, single phase,outdoor type with ratio 400-200A/1-1A, 15 VA burden, class accuracy 0.5 Line CT for metering , The CTs will be complete with bimetallic terminal for connecting ACSR wires, wheather proof
33kv, single pole, single phase,outdoor type with ratio 200-100A/1-1A, 15 VA burden, class accuracy 0.5 Transformer CT for metering and TRF differential protection complete with bimetallic terminals, weather proof secondary terminals, including all accessories.
POTENTIAL TRANSFORMER
Supply of outdoor, single pole Potential transformer with voltage ratio(33/√3 kV)/(110V/√3), output 100 VA burden with class accuracy 0.5. The PT should be complete with bimetallic connectors for connecting it to overhead conductor , whether proof second
33 KV ISOLATOR
Isolator suitable for a system voltage of 33 KV, rated current of 400 A and fault withstand of 16 KA for 1 sec and shall be manual operated, single break type, triple pole, outdoor type, pole mounted suitable for horizontal mounting with EARTH SWITCH
Isolator suitable for a system voltage of 33 KV, rated current of 400 A and fault withstand of 16 KA for 1 sec and shall be manual operated, single break type, triple pole, outdoor type,pole mounted suitable for horizontal mounting WITHOUT EARTH SWITCH
33KV, 400A, 3-ph, Gang switch (Rocking Type Air Break Isolator) along with support insulators operating mechanism, Base Channel down Pipe, terminal connectors and other accessories complete as per IS : 9921 (Pt. I to IV) or its latest amendment and TS Vol II - for 33/0.4KV Station Transformer
33 KV Drop Out fuse of rated current 100 A/ 200 A/400A, complete with fuse carrier assembly, fuse base & tube and mounting arrangement as per IS:9385 (Part-I to III) as amended from time to time and tech spec Vol-II. For 33/0.4 KVStation Transformer
LIGHTNING ARRESTOR
30kV, 10 kA single pole, class2,station type, heavy duty, Lightning Arrestor complete with suitable bimetallic connectors. for ACSR wire connections, parallel groove clamps, weather proof secondary terminals, with-out counter, including all accessories.
DISCHARGE ROD
Supply of discharge rod with clamp having screw type arrangment for fixing tightly on conductor(ASCR) for panther with boalt nut and saddle for earthwire. The operating rod fixed with clamp shall be made of telestone fiber glass tube suitable for 33/11 KV
11KV SIDE EQUIPMENT
11 KV VCB
11 KV VCB 3-ph, with Indoor Panel consisting of Vacuum Circuit breaker, CT, PT, Voltmeter, Ammeter, MW Meter, KwH meter, pf Meter, Frequency Meter, indication lamp, Breaker Control Switch, OC/EF Relays (numerical) , Master trip relay (numerical), Annunciation Windows with Annunciation Relays, Push-Button for Alarm Accept/Reset/Lamp Test, Mimic Diagram etc. & other components as per Technical Specifications. The breaker should be supplied with mandatory/recommended spares such as VI, Trip Coil , indicating lamps etc. ABB/SCHNEIDER/CROMPTON/TOSHIBA Make
11 KV CURRENT TRANSFORMER (METERING AND DIFF PROTECTION)
Supply of 11kv, single pole, single phase,outdoor type with ratio 500-400A/5-5A, 15 VA burden,PS class accuracy 0.5 Transformer CT for metering and differnetial protection. The CTs will be complete with bimetallic terminal for connecting ACSR wires, whe
Supply of 11kv, single pole, single phase,outdoor type with ratio 600-300A/1-1A, 15 VA burden,PS class accuracy 0.5 Neutral CT for protection. The CTs will be complete with bimetallic terminal for connecting ACSR wires, whe
Supply of 11kv, single pole, single phase,outdoor type with ratio 200-100/1A, 15 VA burden, class accuracy 0.5 Line CT for metering, The CTs will be complete with bimetallic terminal for connecting ACSR wires, whether proof secondary terminals,
POTENTIAL TRANSFORMER
Supply of outdoor, single pole Potential transformer with voltage ratio(11/√3 kV)/ (110V/√3), output 100 VA burden with class accuracy 0.5. The PT should be complete with bimetallic connectors for connecting it to overhead conduct0r
11 KV ISOLATOR
The isolator shall be suitable for a system voltage of 11 KV, rated current of 800 A and fault withstand of 16 KA for 1 sec and shall be manual operated, single break type, triple pole, outdoor type,pole mounted suitable for horizontal mounting WITHOUT EARTH SWITCH
Isolator (3-phase) suitable for a system voltage of 11 KV, rated current of 800 A and fault withstand of 16 KA for 1 sec and shall be manual operated, single break type, triple pole, outdoor type,pole mounted suitable for horizontal mounting WITH EARTH SWITCH (for Line)
LIGHTNING ARRESTOR
9kV, 10 kA single pole, class 2, station type, heavy duty, Lightning Arrestor complete with suitable bimetallic connectors for ACSR wire connections, parallel groove clamps, weather proof secondary terminals, with-out counter, including all accessories.
Supply & fixing of 33 KV Pin/Post Insulators with Pin
Supply & fixing of 11 KV Pin/Post insulators with Pin
Supplying and Fixing Disc Insulators (Polymer) 70 KN BS type
Supply & fixing of Steel Fabricated items, additional requirement.
Control & Relay Panels
33 KV Control & Relay Panels
Indoor Relay and Control Panel (consisting of OC/EF numeric relay, Voltmeter, Ammeter, MW Meter, KwH meter, pf Meter, Frequency Meter, indication lamp, Breaker Control Switch, Master trip relay, Annunciation Windows with Annunciation Relays, Push-Button for Alarm Accept/Reset/Lamp Test, Mimic Diagram, static TVM etc. The C/R Panel should be supplied with mandatory/recommended spares such as Control Switches, indicating lamps, HRC fuses etc. - For Feeders Incomer) Breakers
Indoor Control and Relay Panel (consisting of OC/EF numeric relay, Differential relay, Voltmeter, Ammeter, MW Meter, KwH meter, pf Meter, Frequency Meter, indication lamp, Breaker Control Switch, Master trip relay, Annunciation Windows with Annunciation Relays, Push-Button for Alarm Accept/Reset/Lamp Test, Mimic Diagram, static TVM etc. The C/R Panel should be supplied with mandatory/recommended spares such as Control Switches, indicating lamps, HRC fuses etc. - for Transformers HV Incomer Breakers
11 KV Control & Relay Panels
Indoor Control and Relay Panel (consisting of OC/EF numeric relay, Differential relay, Voltmeter, Ammeter, MW Meter, KwH meter, pf Meter, Frequency Meter, indication lamp, Breaker Control Switch, Master trip relay, Annunciation Windows with Annunciation Relays, Push-Button for Alarm Accept/Reset/Lamp Test, Mimic Diagram, static TVM etc. The C/R Panel should be supplied with mandatory/recommended spares such as Control Switches, indicating lamps, HRC fuses etc. - For Transformers LV incomer Breakers
Indoor Control and Relay Panel (consisting of OC/EF numeric relay, Voltmeter, Ammeter, MW Meter, KwH meter, pf Meter, Frequency Meter, indication lamp, Breaker Control Switch, Master trip relay, Annunciation Windows with Annunciation Relays, Push-Button for Alarm Accept/Reset/Lamp Test, Mimic Diagram, static TVM etc. The C/R Panel should be supplied with mandatory/recommended spares such as Control Switches, indicating lamps, HRC fuses etc. - For Outfoing Feeders and Bus Coupler Breakers.
OVERHEAD CONDUCTOR
PANTHER ACSR Conductor
40mm dia GI pipe
80mm dia GI pipe
Copper Control Cables
Supply of 5 C X 2.5 mm sq.
Supply of 10 C X 2.5 mm sq.
Supply of 12 C X 2.5 mm sq.
HT Power Cables
Supply of 33 KV 1 x C 400 sqmm XLPE Al.(for connecting Power Transformer Primary and from Incomer 33KV feeder to Bus)
Supply of 11 KV 1 x C 300 sqmm XLPE Al.(for Connecting Secondary of Power Transformer to 11KV Bus to Outgoing Feeder)
Supply of 11 KV 3C X185 sq. mm. XLPE Al. (For DT)
LT XLPE Armoured Aluminium Power Cable of following sizes, 1.1KV
PVC insulated AL armoured Power cables 2 xC, 25 sqmm
PVC insulated AL armoured Power 3½ xC, 35 sqmm
PVC insulated AL armoured Power 3½ x C, 70 sqmm
PVC insulated AL armoured Power 3.5C X 95 SQ.MM
PVC insulated AL armoured Power 3.5C X 120 SQ.MM
LT XLPE Unarmoured Copper Power Cable of following sizes, 1.1KV
PVC Insulated CU unarmoured Power cables1C x 25 SQ.MM.
PVC Insulated CU unarmoured Power cables1C x 70 SQ.MM.
Termination Kit
Supply of 33 KV Termination Kit for 1 C X 400 mm sq. XLPE cable( for connecting 33kV Auto recloser to Power Transformer Primary and for Incomer 33KV feeder to Bus)
Supply of 11 KV Termination Kit for 1 C X 630 mm sq. XLPE cable ( for Connecting Secondary of Power Transformer to 11kV Incomer Auto Reclosers and for Autorecloser to outgoing feeder - 4 outgoing 11KV Feeders).
Supply of 11 KV Termination Kit for 1 C X 185 mm sq. XLPE cable ( for DTs etc).
Earthing & Lightning Protection
Supply of 3.0 mtr 40mm dia GI Pipe Earthing
Supply of Copper Plate Earthing for Transformer Neutral (600x600x3.15)
Supply of Earthing Strip
75X6mm GI Strip
50X10mm GI Strip
50X6mm GI Strip
25X3mm GI Strip
50X6mm Copper Strip
Supply of CT & PT Jnc Box (12 way)
Lightining spike
Down conductor for Lightining spike (25x3mm GI Strip)
Control Room Auxiiaries
24V, 65AH, Lead Acid type Battery Set at 10 Hr Discharge Rate consisting of 11 Nos., each of 2.2V Cell having float level indicators, terminal connectors along with suitable wooden rack, required quantity of acid, distilled water & all other accessories and connectors required for installation, testing & commissioning as per technical specifications.
Transistorised Battery Charger Set with full wave rectification, 1-ph, 200/240V, 50Hz Input Voltage for charging 24V, 65AH Battery along with required cable, connectors etc. for conection with 24 V 64AH Battery Set & 220V AC Source and 24V DCDB
415 Volt LTAC Panel as per specification with 250A TPN MCCB as incomer ,2x 100A MCCB,2x32A TP ,5x16A TP, 4x16A DP,1x32A DP MCB.
24V DCDB as per TS & the Electrical Layout
Supply, of following Transformers
33/11KV, 2.5 MVA Oil Type Transformer
33/0.433KV, 25 KVA, oil type Station transformer
Description of Work / Item(s)
Amount
A. Erection, Installation & Comissioning of Materials for Construction of 33 KV Lines
ACSR Mink 6/1/3.66 mm
Steel tubular pole SP 45 (Half-Galvanised)
70 KM Ball & Socket (B&S) Type 11 kV Disc Insulator, complete
Hardware fittings for B&S Disc Insulator, complete
33 kV Pin Insulator, complete with GI pin
MS Channel 100x50x6 mm for X-arm, 27.6 kg per channel
3.5 Mtr length weighing 12.25 kg for disgonal member
2.5 Mtr length weighing 8.75 kg for horizontal member
Guard Bracket
Stay set 19 mm dia. 1.6 Mtr length with stay rod and bow plate
GI Stay wire 7/10 SWG weighing 43.4 kg per 100 mtr coil. 12 mtr per stay
Danger plate for 33 kv
MS Double Clamp 4.5" (115 mm) dia (top)
MS Single Clamp 4.5" (115 mm) dia (top)
MS Single Clamp 5.5" (140 mm) dia (middle)
GI Nuts & Bolts 5/8" x 3" (16x75 mm)
GI Nuts & Bolts 5/8" x 3" (16x200 mm)
GI Washers 5/8" x 3" (18 mm dia for 16 mm bolts)
CIVIL WORKS
Job- PCC 1:3:6 Grouting of Poles (2ftx2ftx4 ft) per pole - 0.45 Cum)
Job-Grouting for Stay
B. Erection, Installation & Comissioning of Materials for Construction of 2.5 MVA Sub-Station
Structure for 33KV and 11KV bay
GI Steel Tubular Pole SP 76 (33KV bay- 4 nos, 11KV bay 6 nos )
GI MS Channel 100x50x6mm for cross arm and support of equipment - 2.2 M Long weighing 20.24 kg each (Galvanised)
GI M.S Angle 50x50x6x5000 mm each weighing 22.5 Kg (Galvanised)
Pole Double Clamp of G.I flat 50x6 mm
GI Nuts & Bolts with washer ( Assorted sizes including through bolt)
33KV SIDE EQUIPMENT
33KV VCB
33 kV SF6 circuit breaker, 3-Ph (out-door type ) complete
CURRENT TRANSFORMER (METERING AND PROTECTION)
INCOMING
Supply of 33kv, single pole, single phase,outdoor type with ratio 400-200A/1-1A, 15 VA burden, class accuracy 0.5 Line CT for metering , The CTs will be complete with bimetallic terminal for connecting ACSR wires, wheather proof
33kv, single pole, single phase,outdoor type with ratio 200-100A/1-1A, 15 VA burden, class accuracy 0.5 Transformer CT for metering and TRF differential protection complete with bimetallic terminals, weather proof secondary terminals, including all accessories.
POTENTIAL TRANSFORMER
Supply of outdoor, single pole Potential transformer with voltage ratio(33/√3 kV)/(110V/√3), output 100 VA burden with class accuracy 0.5. The PT should be complete with bimetallic connectors for connecting it to overhead conductor , whether proof second
33 KV ISOLATOR
Isolator suitable for a system voltage of 33 KV, rated current of 400 A and fault withstand of 16 KA for 1 sec and shall be manual operated, single break type, triple pole, outdoor type, pole mounted suitable for horizontal mounting with EARTH SWITCH
Isolator suitable for a system voltage of 33 KV, rated current of 400 A and fault withstand of 16 KA for 1 sec and shall be manual operated, single break type, triple pole, outdoor type,pole mounted suitable for horizontal mounting WITHOUT EARTH SWITCH
33KV, 400A, 3-ph, Gang switch (Rocking Type Air Break Isolator) along with support insulators operating mechanism, Base Channel down Pipe, terminal connectors and other accessories complete as per IS : 9921 (Pt. I to IV) or its latest amendment and TS Vol II - for 33/0.4KV Station Transformer
33 KV Drop Out fuse of rated current 100 A/ 200 A/400A, complete with fuse carrier assembly, fuse base & tube and mounting arrangement as per IS:9385 (Part-I to III) as amended from time to time and tech spec Vol-II. For 33/0.4 KVStation Transformer
LIGHTNING ARRESTOR
30kV, 10 kA single pole, class2,station type, heavy duty, Lightning Arrestor complete with suitable bimetallic connectors. for ACSR wire connections, parallel groove clamps, weather proof secondary terminals, with-out counter, including all accessories.
DISCHARGE ROD
Supply of discharge rod with clamp having screw type arrangment for fixing tightly on conductor(ASCR) for panther with boalt nut and saddle for earthwire. The operating rod fixed with clamp shall be made of telestone fiber glass tube suitable for 33/11 KV
11KV SIDE EQUIPMENT
11 KV VCB
11 KV VCB 3-ph, with Indoor Panel consisting of Vacuum Circuit breaker, CT, PT, Voltmeter, Ammeter, MW Meter, KwH meter, pf Meter, Frequency Meter, indication lamp, Breaker Control Switch, OC/EF Relays (numerical) , Master trip relay (numerical), Annunciation Windows with Annunciation Relays, Push-Button for Alarm Accept/Reset/Lamp Test, Mimic Diagram etc. & other components as per Technical Specifications. The breaker should be supplied with mandatory/recommended spares such as VI, Trip Coil , indicating lamps etc. ABB/SCHNEIDER/CROMPTON/TOSHIBA Make
11 KV CURRENT TRANSFORMER (METERING AND DIFF PROTECTION)
Supply of 11kv, single pole, single phase,outdoor type with ratio 500-400A/5-5A, 15 VA burden,PS class accuracy 0.5 Transformer CT for metering and differnetial protection. The CTs will be complete with bimetallic terminal for connecting ACSR wires, whe
Supply of 11kv, single pole, single phase,outdoor type with ratio 600-300A/1-1A, 15 VA burden,PS class accuracy 0.5 Neutral CT for protection. The CTs will be complete with bimetallic terminal for connecting ACSR wires, whe
Supply of 11kv, single pole, single phase,outdoor type with ratio 200-100/1A, 15 VA burden, class accuracy 0.5 Line CT for metering, The CTs will be complete with bimetallic terminal for connecting ACSR wires, whether proof secondary terminals,
POTENTIAL TRANSFORMER
Supply of outdoor, single pole Potential transformer with voltage ratio(11/√3 kV)/ (110V/√3), output 100 VA burden with class accuracy 0.5. The PT should be complete with bimetallic connectors for connecting it to overhead conduct0r
11 KV ISOLATOR
The isolator shall be suitable for a system voltage of 11 KV, rated current of 800 A and fault withstand of 16 KA for 1 sec and shall be manual operated, single break type, triple pole, outdoor type,pole mounted suitable for horizontal mounting WITHOUT EARTH SWITCH
Isolator (3-phase) suitable for a system voltage of 11 KV, rated current of 800 A and fault withstand of 16 KA for 1 sec and shall be manual operated, single break type, triple pole, outdoor type,pole mounted suitable for horizontal mounting WITH EARTH SWITCH (for Line)
LIGHTNING ARRESTOR
9kV, 10 kA single pole, class 2, station type, heavy duty, Lightning Arrestor complete with suitable bimetallic connectors for ACSR wire connections, parallel groove clamps, weather proof secondary terminals, with-out counter, including all accessories.
Supply & fixing of 33 KV Pin/Post Insulators with Pin
Supply & fixing of 11 KV Pin/Post insulators with Pin
Supplying and Fixing Disc Insulators (Polymer) 70 KN BS type
Supply & fixing of Steel Fabricated items, additional requirement.
Control & Relay Panels
33 KV Control & Relay Panels
Indoor Relay and Control Panel (consisting of OC/EF numeric relay, Voltmeter, Ammeter, MW Meter, KwH meter, pf Meter, Frequency Meter, indication lamp, Breaker Control Switch, Master trip relay, Annunciation Windows with Annunciation Relays, Push-Button for Alarm Accept/Reset/Lamp Test, Mimic Diagram, static TVM etc. The C/R Panel should be supplied with mandatory/recommended spares such as Control Switches, indicating lamps, HRC fuses etc. - For Feeders Incomer) Breakers
Indoor Control and Relay Panel (consisting of OC/EF numeric relay, Differential relay, Voltmeter, Ammeter, MW Meter, KwH meter, pf Meter, Frequency Meter, indication lamp, Breaker Control Switch, Master trip relay, Annunciation Windows with Annunciation Relays, Push-Button for Alarm Accept/Reset/Lamp Test, Mimic Diagram, static TVM etc. The C/R Panel should be supplied with mandatory/recommended spares such as Control Switches, indicating lamps, HRC fuses etc. - for Transformers HV Incomer Breakers
11 KV Control & Relay Panels
Indoor Control and Relay Panel (consisting of OC/EF numeric relay, Differential relay, Voltmeter, Ammeter, MW Meter, KwH meter, pf Meter, Frequency Meter, indication lamp, Breaker Control Switch, Master trip relay, Annunciation Windows with Annunciation Relays, Push-Button for Alarm Accept/Reset/Lamp Test, Mimic Diagram, static TVM etc. The C/R Panel should be supplied with mandatory/recommended spares such as Control Switches, indicating lamps, HRC fuses etc. - For Transformers LV incomer Breakers
Indoor Control and Relay Panel (consisting of OC/EF numeric relay, Voltmeter, Ammeter, MW Meter, KwH meter, pf Meter, Frequency Meter, indication lamp, Breaker Control Switch, Master trip relay, Annunciation Windows with Annunciation Relays, Push-Button for Alarm Accept/Reset/Lamp Test, Mimic Diagram, static TVM etc. The C/R Panel should be supplied with mandatory/recommended spares such as Control Switches, indicating lamps, HRC fuses etc. - For Outfoing Feeders and Bus Coupler Breakers.
OVERHEAD CONDUCTOR
PANTHER ACSR Conductor
40mm dia GI pipe
80mm dia GI pipe
Copper Control Cables
Supply of 5 C X 2.5 mm sq.
Supply of 10 C X 2.5 mm sq.
Supply of 12 C X 2.5 mm sq.
HT Power Cables
Supply of 33 KV 1 x C 400 sqmm XLPE Al.(for connecting Power Transformer Primary and from Incomer 33KV feeder to Bus)
Supply of 11 KV 1 x C 300 sqmm XLPE Al.(for Connecting Secondary of Power Transformer to 11KV Bus to Outgoing Feeder)
Supply of 11 KV 3C X185 sq. mm. XLPE Al. (For DT)
LT XLPE Armoured Aluminium Power Cable of following sizes, 1.1KV
PVC insulated AL armoured Power cables 2 xC, 25 sqmm
PVC insulated AL armoured Power 3½ xC, 35 sqmm
PVC insulated AL armoured Power 3½ x C, 70 sqmm
PVC insulated AL armoured Power 3.5C X 95 SQ.MM
PVC insulated AL armoured Power 3.5C X 120 SQ.MM
LT XLPE Unarmoured Copper Power Cable of following sizes, 1.1KV
PVC Insulated CU unarmoured Power cables1C x 25 SQ.MM.
PVC Insulated CU unarmoured Power cables1C x 70 SQ.MM.
Termination Kit
Supply of 33 KV Termination Kit for 1 C X 400 mm sq. XLPE cable( for connecting 33kV Auto recloser to Power Transformer Primary and for Incomer 33KV feeder to Bus)
Supply of 11 KV Termination Kit for 1 C X 630 mm sq. XLPE cable ( for Connecting Secondary of Power Transformer to 11kV Incomer Auto Reclosers and for Autorecloser to outgoing feeder - 4 outgoing 11KV Feeders).
Supply of 11 KV Termination Kit for 1 C X 185 mm sq. XLPE cable ( for DTs etc).
Earthing & Lightning Protection
Supply of 3.0 mtr 40mm dia GI Pipe Earthing
Supply of Copper Plate Earthing for Transformer Neutral (600x600x3.15)
Supply of Earthing Strip
75X6mm GI Strip
50X10mm GI Strip
50X6mm GI Strip
25X3mm GI Strip
50X6mm Copper Strip
Supply of CT & PT Jnc Box (12 way)
Lightining spike
Down conductor for Lightining spike (25x3mm GI Strip)
Control Room Auxiiaries
24V, 65AH, Lead Acid type Battery Set at 10 Hr Discharge Rate consisting of 11 Nos., each of 2.2V Cell having float level indicators, terminal connectors along with suitable wooden rack, required quantity of acid, distilled water & all other accessories and connectors required for installation, testing & commissioning as per technical specifications.
Transistorised Battery Charger Set with full wave rectification, 1-ph, 200/240V, 50Hz Input Voltage for charging 24V, 65AH Battery along with required cable, connectors etc. for conection with 24 V 64AH Battery Set & 220V AC Source and 24V DCDB
415 Volt LTAC Panel as per specification with 250A TPN MCCB as incomer ,2x 100A MCCB,2x32A TP ,5x16A TP, 4x16A DP,1x32A DP MCB.
24V DCDB as per TS & the Electrical Layout
Supply, of following Transformers
33/11KV, 2.5 MVA Oil Type Transformer
33/0.433KV, 25 KVA, oil type Station transformer
Civil Works
Cement Concrete footing
Cable trench
Antiweed treatment
Control room
Fencing
Site levelling
Approach road
Drainage
Description of Work / Item(s)
Amount
Taxes Applicable on Supply and Erection, Dismatling, Installation, Civil works & Commissioning of Materials
Total GST on Supply of Materials (BoQ1)
Total GST on Erection, Installation, Civil works & Commissioning (BoQ2)
Total Labour Cess on Erection, Installation, Civil works & Commissioning (BoQ2)
Description of Work / Item(s)
Amount
TOTAL SCHEDULE NO. 1
Ex-works supply of materials (BoQ1)
TOTAL SCHEDULE NO. 2
Erection, Installation & Commissioning (BoQ2)
TOTAL SCHEDULE NO. 3
Taxes (GST & Labour Cess) (BoQ3)
techno power enterprises private limited (BID ID -3027)
RAUSHEENA UDYOG LIMITED (BID ID -3031)
techno power enterprises private limited (BID ID -3027)
RAUSHEENA UDYOG LIMITED (BID ID -3031)
techno power enterprises private limited (BID ID -3027)
RAUSHEENA UDYOG LIMITED (BID ID -3031)
techno power enterprises private limited (BID ID -3027)
RAUSHEENA UDYOG LIMITED (BID ID -3031)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .