Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 CrAccepted-AOC | ₹2.8 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹2.9 Cr+₹6.9 L (2.48%)Rejected-Finance | ₹2.9 Cr+₹6.9 L (2.48%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹3.6 Cr+₹79.0 L (28.2%)Rejected-Finance | ₹3.6 Cr+₹79.0 L (28.2%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹3.8 Cr+₹97.7 L (34.9%)Rejected-Finance GURDWARA LINE SHOWROOM NO 6 DESHMESH MARKET SRI VIJAYA PURAM 744101 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | ₹3.8 Cr+₹97.7 L (34.9%) | L4 | Rejected-Finance Not being lowest |
| Sl No | Description | Qty | Unit | Kailash Engineering Company L3 | SALCON ENGINEERS AND FABRICATORS L4 | KCM BUILDERS & CONSTRUCTIONS (INDIA) PVT.LTD L1 | PRASHANTH ERECTOR AND BUILDERS PVT LTD L2 |
|---|---|---|---|---|---|---|---|
| 1.00GENERAL SUMMARY NOTE: Schedule ‘A’ Part - I to IX are prepriced by MES under Ser No. 2.00 to 10.00. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. | |||||||
| 2.00 | Lumpsum price worked out by the contractor for “BUILDINGS/STRUCTURES” as listed under Schedule ‘A’ Part - I , inserted by MES. | 1 | Lump sum | 1,87,71,346 ₹1,87,71,346 | 1,90,98,346 ₹1,90,98,346 | 1,18,20,000 ₹1,18,20,000 Lowest | 1,54,87,600 ₹1,54,87,600 |
| 3.00 | Lumpsum price worked out by the contractor for “BUILDING WORK ADDITION AND ALTERATION” as listed in Schedule ‘A’ Part - IA, inserted by MES. | 1 | Lump sum | 11,11,725 ₹11,11,725 Lowest | 11,81,562 ₹11,81,562 | 12,41,350 ₹12,41,350 | 11,90,000 ₹11,90,000 |
| 4.00 | Lumpsum price worked out by the contractor for “EXCAVATION & EARTHWORK INCLUDING SITE CLEARANCE AND LAND DEVELOPMENT” as listed in Schedule ‘A’ Part - II , inserted by MES. | 1 | Lump sum | 7,29,120.6 ₹7,29,120.6 | 7,31,411 ₹7,31,411 | 11,02,575 ₹11,02,575 | 6,80,000 ₹6,80,000 Lowest |
| 5.00 | Lumpsum price worked out by the tenderer for "LIST OF WORKS AND PRICES INTERNAL ELECTRIC SUPPLY" as listed in Schedule ‘A’ Part-III, inserted by MES. | 1 | Lump sum | 10,73,497 ₹10,73,497 | 11,84,990 ₹11,84,990 | 9,05,000 ₹9,05,000 Lowest | 9,40,000 ₹9,40,000 |
| 6.00 | Lumpsum price worked out by the tenderer for "AIR CONDITION AND REFRIGERATION " as listed in Schedule ‘A’ Part- IV, inserted by MES. | 1 | Lump sum | 13,38,171 ₹13,38,171 | 13,98,316 ₹13,98,316 | 13,85,000 ₹13,85,000 | 12,00,000 ₹12,00,000 Lowest |
| 7.00 | Lumpsum price worked out by the tenderer for "DOMESTIC COOLING APPLIANCE STANDBY PURPOSE" as listed in Schedule ‘A’ Part- V, inserted by MES. | 1 | Lump sum | 11,81,256 ₹11,81,256 | 11,95,900 ₹11,95,900 | 11,50,000 ₹11,50,000 | 8,80,000 ₹8,80,000 Lowest |
| 8.00 | Lumpsum price worked out by the tenderer for "CHEMICAL EARTHING" as listed in Schedule ‘A’ Part- VI, inserted by MES. | 1 | Lump sum | 2,10,500 ₹2,10,500 | 2,12,698 ₹2,12,698 | 75,000 ₹75,000 Lowest | 84,000 ₹84,000 |
| 9.00 | Lumpsum price worked out by the tenderer for "AREA DRAINAGE" as listed in Schedule ‘A’ Part- VII, inserted by MES. | 1 | Lump sum | 42,47,890 ₹42,47,890 | 43,17,805 ₹43,17,805 | 48,99,650 ₹48,99,650 | 33,80,000 ₹33,80,000 Lowest |
| 10.00 | Lumpsum price worked out by the tenderer for "EXTERNAL ELECTRIC SUPPLY" as listed in Schedule ‘A’ Part- VIII, inserted by MES. | 1 | Lump sum | 24,95,150 ₹24,95,150 | 24,98,560 ₹24,98,560 | 12,25,150 ₹12,25,150 Lowest | 13,20,000 ₹13,20,000 |
Tender Value
₹3.3 Cr
EMD Value
₹4.0 L
Closing Date
20 Oct 2025, 6:00 pmClosed
CHIEF ENGINEER A and N Zone
HQ CE A and N Zone MES Brichgunj Junglighat post Sri Vijaya Puram
PROVN OF LIGHTING AND SUB STN INCL LAND DEVP FOR INSTALLATION OF DVOR AND TACAN AT INS BAAZ
2025_MES_729783_1
801234/R/E8
Open Tender
Civil Works
Lump-sum
550 days
CAMPBELL BAY
Please refer Tender documents.
9 documents required · 9 mandatory
₹2,000
GE I CAMPBELL BAY
₹4.0 L
Yes
9 Dec 2025
8 Sept 2025
23 Oct 2025
8 Sept 2025
20 Oct 2025
6 Oct 2025
Amount
GENERAL SUMMARY NOTE: Schedule ‘A’ Part - I to IX are prepriced by MES under Ser No. 2.00 to 10.00. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for “BUILDINGS/STRUCTURES” as listed under Schedule ‘A’ Part - I , inserted by MES.
Lumpsum price worked out by the contractor for “BUILDING WORK ADDITION AND ALTERATION” as listed in Schedule ‘A’ Part - IA, inserted by MES.
Lumpsum price worked out by the contractor for “EXCAVATION & EARTHWORK INCLUDING SITE CLEARANCE AND LAND DEVELOPMENT” as listed in Schedule ‘A’ Part - II , inserted by MES.
Lumpsum price worked out by the tenderer for "LIST OF WORKS AND PRICES INTERNAL ELECTRIC SUPPLY" as listed in Schedule ‘A’ Part-III, inserted by MES.
Lumpsum price worked out by the tenderer for "AIR CONDITION AND REFRIGERATION " as listed in Schedule ‘A’ Part- IV, inserted by MES.
Lumpsum price worked out by the tenderer for "DOMESTIC COOLING APPLIANCE STANDBY PURPOSE" as listed in Schedule ‘A’ Part- V, inserted by MES.
Lumpsum price worked out by the tenderer for "CHEMICAL EARTHING" as listed in Schedule ‘A’ Part- VI, inserted by MES.
Lumpsum price worked out by the tenderer for "AREA DRAINAGE" as listed in Schedule ‘A’ Part- VII, inserted by MES.
Lumpsum price worked out by the tenderer for "EXTERNAL ELECTRIC SUPPLY" as listed in Schedule ‘A’ Part- VIII, inserted by MES.
Lumpsum price worked out by the tenderer for "FENCING AND GATE" as listed in Schedule ‘A’ Part- IX, inserted by MES.
Subtotal
NOTE: Schedule ‘A’ Part - X (miscellaneous) are not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-6.
INTERNAL ELECTRIC SUPPLY S&F VTPN MCCB DB 4 Way 415V, 3-Ph, 50hz, 250 Amps rating IP-54 protection, double door, With provision for 160 Amps MCCB as incomer and SP/TP MCB's as outgoing all as specified and as directed.
S&F VTPN MCCB DB 6 Way 415V, 3-Ph, 50hz, 250 Amps rating IP-54 protection, double door, With provision for 160 Amps MCCB as incomer and SP/TP MCB's as outgoing all as specified and as directed.
BUILDING WORK ADDITION AND ALTERATION M&L for 5mm thick Rubber Mats of size minimum 2.0x2.0 metres for equipment and operator consoles as per specification and drawing complete all as specified and as directed by Engineer-In- Charge
AIR CONDITION AND REFRIGERATION Supply install testing and commissioning of Voltage Stabilizer for automatic correction and operation single phase natural air cooled and designed for input variation of between 170 to 250 V with output stabilizer at 230V with necessary +/- 2.5% and of capacity 4 KVA complete.
Supply install, testing and commissioning Voltage Stabilizer for automatic correction and operation single phase natural air cooled and designed for input variation between 170 to 250 V with output stabilizer at 230V with necessary +/- 2.5% and of capacity 5 KVA complete.
CHEMICAL EARTHING Material & labour and testing of tripode earthing (3 Nos earthing interconected to one set) maintenance free earthing solution comprising with the following:- (a)Supply & fixing maint free earthing, after digging bore of suitable size, and UL certified manitenance free earthing system having a set of copper bounded earth rode of 03 meter length, 18/17.2 mm internal dia with wall thickness of 2 mm made of high tensile low steel circular rod, molecularly bonded with 99% electrolytic grade copper on outer surface (minimum copper bonding thickness- 250 microns) with exothermically jointed copper bar of 200 x25x6mm for long lasting and connected. Earth copper bonded rod and exothermically jointed busbar shoulder be CPRI tested on 25KA fault current complete all as specified and directed by Engr-in-Charge for complete connection- Qty 03 Nos. (b) earth copper bonded electrode should be tested by CPRI. (c) Current carrying of earth copper bonded electrode shall be of 25 KA/Sec. (d)Supply and filling of carbon waste, eco friendly earth enhancing compound of RHOS, tested by NABL accredated lab in compliance of IEC-62561-7 and having passed leaching, sulpher corrosion resistivity tests as per IEC-62561-7 and international standard for earth enhancement compound in compliance to IEC-62561-7 with a restivity <0.12 ohm-m, 25Kg- Qty 03 Nos.
(e) Earthing enhancing compound shall be free from corrosion, it shall be carbon based material and shall be free from bentonite and other hazard substance. The product does not dissolve/deteriorate or leach out of time. It shall be highly conductive and improve earth absorbing power and humidity retention capability. It shall be ecofriendly and chemically inert to sub soil. (f) Supply and fixing plastic/ FRP earth pit of size 247mm x 338mm complying IEC-62561-5 - Qty 3 Nos. Note : (i) One testing after completion of job, if desired earth resistance is not found i.e below 01 ohm, the earth shall be re-done at no extra cost to the government. Any additional work and material required to achieve the required result is included in the cost. (ii) Rate included for testing, commissioning including checking of earth continuity and earth result complete all as specified and directed. (iii) Vendors are bound to provide earthing result upto 1 ohm with grid of three earthings. (iv) Earth strip beyond 7.5 Mtr is deemed to be included in quoted rate. (v) earth work is deemed to be included in the quoted rate. Make ; JMV LPS Ltd/Ennov/Advence earthing Solution (AES).
EXTERNAL ELECTRIC SUPPLY Supply, install, testing and commissioning of LT cubical outdoor type panel made out of CRCA sheet 3.00 mm thick totally enclosed CPRI approved/ type tested with front and rear opening, hinged doors with projected and raised platform of suitable size weather proof along with lugs, cable glands of various sizes for cables, danger notice plate, stickering of switch gear about load termination, cable connector for connecting multi cables locted in cable chamber terminated from the switchgear the nuts/ bolts etc used are to be made of rust proof material as per IS:8623 with aluminum bus bar of 250 A with insulators sutable for three phase and neutral complete & powder coating with epoxy powder coated mat finish of SIEMENTS GREY structural RAL7032 shade colour, built industrial type locking arrangement on front and back and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on suitable size & thickness of angle iron frame ( proper mounting shall be done) duly painted and embedded in necessary required quantity of PCC 1:3:6 type C1, 30cm below ground level and 30cm above ground level and consisting the following provisions:- (a) MCCB 4 pole 250 Amps,35kA with thermal magnetic release -01Nos(incoming) (b) MCCB 4 pole 100 Amps, 16KA -02Nos (Outgoing -01 +01 Spare)
Supply, install, testing and commissioning of LT cubical outdoor type panel made out of CRCA sheet 3.00 mm thick totally enclosed CPRI approved/ type tested with front and rear opening, hinged doors with projected and raised platform of suitable size weather proof along with lugs, cable glands of various sizes for cables, danger notice plate, stickering of switch gear about load termination, cable connector for connecting multi cables located in cable chamber terminated from the switchgear danger notice bolts and the nuts/ bolts etc used are to be made of rust proof material incl as per IS:8623 with aluminium bus with insulators suitable for three phase and neutral complete & powder coating with epoxy powder coated mat finish of SIEMENTS GREY structural RAL7032 shade colour, built industrial type locking arrangement on front and back and pre wired with PVC insulated multi standed copper conductor for controls and monitors, PVC sleeved aluminum strip for connecting MCCBs, Panel mounted on suitable size & thickness of angle iron frame(proper mounting shall be done) duly painted and embedded in necessary required quantity of PCC 1:3:6 type C1, 45cm below ground level and 30cm above ground level and consisting the following provisions:- (a) MCCB 4 pole 100Amps,16kA with thermal magnetic release -01Nos(incoming) (b) MCCB 4 pole 63 Amps,16kA -03 Nos(Outgoing -05 +01 Spare)
Supply and install, testing and commissioning of LT cubical outdoor type panel made out of CRCA sheet 3.00 mm thick totally enclosed CPRI approved/ type tested with front and rear opening, hinged doors with projected and raised platform of suitable size weather proof along with lugs, cable glands of various sizes for cables, danger notice plate, stickering of switch gear about load termination, cable connector for connecting multi cables located in cable chamber terminated from the switchgear danger notice bolts and the nuts/ bolts etc used are to be made of rust proof material incl as per IS:8623 with aluminium bus bar of 125 A with insulators suitable for three phase and neutral complete & powder coating with epoxy powder coated mat finish of SIEMENTS GREY structural RAL 7032 shade colour, built industrial type locking arrangement on front and back and pre wired with PVC insulted multi standed copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on suitable size & thickness of angle iron frame (proper mounting shall be done) duly painted and embedded in necessary required quantity of PCC 1:3:6 type C1, 30cm below ground level and 30cm above ground level and consisting the following provisions:- (a) MCCB 4 pole 63Amps,16kA with thermal magnetic release -01Nos(incoming) (b)MCCB 4 pole 40 Amps,16kA -03Nos(Outgoing -02+01 No spare)
M & L cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling for laying of cable pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
Supply and laying HDPE DWC pipe of size 120mm (OD) x 103mm (ID) along with connected accessories like couplers, bends end caps etc for LT/HT cable protection complete confirming to IS-14930 Part II with IP 67 protection all as specified and as directed by Engineer-in Charge.
Disconnection / taking out & shiftingt of existing DG sets from foundatation / original position alongwith all electrical connections & kept it in safe position without any damage by mechanically properly . After bldg work completed the DG Set repositioned in same location & connect the DG set with all Electrical cables as per original fitted aong with T&P required for shiting complete all as specified and as directed by Engr-in-Charge.
Disconnection / taking out & shiftingt of existing DG Panel board from foundatation / original position alongwith all electrical connections & kept it in safe position without any damage by mechanically properly . After bldg work completed the DG Panel board shall be repositioned in same location & connect the DG panale Board with all Electrical cables as per original fitted aong with T&P required for shiting complete all as specified and as directed by E-in-Charge.
PRASHANTH ERECTOR AND BUILDERS PVT LTD (BID ID -3449418)
Kailash Engineering Company (BID ID -3449836)
SALCON ENGINEERS AND FABRICATORS (BID ID -3454823)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.49 MB
801234PrepricedSch08Sep25.pdf
Additional Documents • 0.37 MB
801234DrgsDVORandTACAN.pdf
Additional Documents • 21.37 MB
801234TenderPagesuptoSplCond.pdf
Tender Documents • 1.20 MB
801234PS08Sep25.pdf
Additional Documents • 1.17 MB
801234DrgsDVORandTACAN16APR2025REV.pdf
Additional Documents • 14.81 MB
BOQ_817020.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .