Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹1.1 L 3 Y OUR PRICE BID OPENED ON 02 03 2024 4 C ORRIGENDUM I DATED ON 24 02 2024 5 |
Tender Value
₹13.5 Cr
EMD Value
₹13.5 L
Closing Date
20 Jul 2023, 11:00 amClosed
Civil and Interior, Electrical, Painting, plumbing work, Solar panel system, Rain Water Harvesting, Lifts, Horticulture etc
NSL/CEO/SIDBI-PKL/NIT/2023/587
NSL/CEO/SIDBI-PKL/NIT/2023/587
Open Tender-Domestic
Civil Works General
Panchkula, Haryana
₹11,800
₹13.5 L
28 Nov 2023
5 Jul 2023
20 Jul 2023
20 Jul 2023
4 Aug 2023
ABSTRACT OF COST
S.N. DESCRIPTION OF ITEM DSR AMOUNT (IN LACS) MR AMOUNT (IN LACS)
1 EXTERIOR SITE WORK 1,02,95,745.14 62,34,105.05
2 BHK Civil, Electrical, Plumbing works including Solar
2 Panels, Lifts, SS Railings, Flooring of common lobby area, 3,90,99,071.31 2,05,07,338.47
Waterproofing of Terrace area
3 BHK Civil, Electrical, Plumbing works including Solar
3 Panels, Lifts, SS Railings, Flooring of common lobby area, 1,93,88,453.14 92,88,102.70
Waterproofing of Terrace area
6 FIRE FIGHTING WORK 84,60,079.55 0.00
8 RAIN WATER HARVESTING 15,21,000.00
7 MULTIPLYING FACTOR FOR 18 % GST 1.0633
8 Total Rs including 18 % GST 90452645.14 3,83,04,971.29
10 GRAND TOTAL Rs with GST 135089301.59
10 GRAND TOTAL Rs with GST 135089301.59
Digitally signed by SANJAY
Sl No DSR No Description of Item Location Unit Quantity DSR rate Amount(Rs) Market Rate Amount(Rs)
Sub-Head : Site works
Demolishing brick work manually/ by mechanical means including stacking of
1 15.7 serviceable material and disposal of unserviceable material within 50 metres lead West side boundary wall
as per direction of Engineer-in-charge..
15.7.4 In cement mortar (One side Boundary wall) Cum 62.55 1,698.45 1,06,238.05
Dismantling old plaster or skirting raking out joints and cleaning the surface for
2 15.56 Boundary Wall plaster Both Side Sqm 768.30 45.05 34,611.92
plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Demolishing R.C.C. work by mechanical means and stockpiling at designated
locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking Plinth, top beam of sagged
serviceable and unserviceable material separately including cutting reinforcement Bounday wall
Demolishing cement concrete manually/ by mechanical means including disposal
4 15.2 CC flooring of the campus 0.00
of material within 50 metres lead as per direction of Engineer - in - charge.
15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) Cum 850.00 2,007.10 17,06,035.00
Dismantling tile work in floors and roofs laid in cement mortar including stacking
material within 50 metres lead.
15.23.2 For thickness of tiles above 25 mm and up to 40 mm Sqm 50.00 93.40 4,670.00
Dismantling stone slab flooring laid in cement mortar including stacking of
serviceable material and disposal of unserviceable material within 50 metres lead
Dismantling asbestos cement pressure pipes including excavation and refilling
Sewage and Waste Water Drain
7 15.47 trenches after taking out the pipes manually/ by mechanical means and stacking
the pipes within 50 metres lead as per direction of Engineer-in-charge :
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste
materials by mechanical means, including loading, transporting, unloading to
approved municipal dumping ground or as approved by Engineer-in-charge,
beyond 50 m initial lead, for all leads including all lifts involved.
Excavating trenches of required width for pipes, cables, etc including excavation
for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including
getting out the excavated soil, and then returning the soil as required, in layers not
exceeding 20 cm in depth, including consolidating each deposited layer by
ramming, watering, etc. and disposing of surplus excavated soil as directed, within
a lead of 50 m :
2.10.1 All kinds of soil
2.10.1.3 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm metre 195.00 651.55 1,27,052.25
Earth work in excavation by mechanical means (Hydraulic excavator) / manual
means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on
plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including
getting out the excavated soil and disposal of surplus excavated soil as directed,
within a lead of 50
2.8.1 All kinds of soil cum 120.00 286.85 34,422.00
Filling available excavated earth (excluding rock) in trenches, plinth, sides of
11 2.25 foundations etc. in layers not exceeding 20cm in depth, consolidating each cum 100.00 253.95 25,395.00
deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Extention of Bounday wall+ new
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation
12 6.4 boundary wall+other
7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
mislaneous works
6.4.1 Cement mortar 1:4 (1 cement : 4 coarse sand) Cum 75.20 8,512.10 6,40,109.92
Providing and laying factory made chamfered edge Cement Concrete paver
blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required
strength, thickness & size/ shape, made by table vibratory method using PU mould,
laid in required colour & pattern over 50mm thick compacted bed of sand,
13 16.91.2 compacting and proper embedding/laying of inter locking paver blocks into the Along the existing CC Road
sand bedding layer through vibratory compaction by using plate vibrator, filling the
joints with sand and cutting of paver blocks as per required size and pattern,
finishing and sweeping extra sand. complete all asper direction of Engineer-in-
80 mm thick C.C. paver block of M-30 grade with approved colour design and
Digitally signed by SANJAY
Providing and laying at or near ground level factory made kerb stone of M-25
grade cement concrete in position to the required line, level and curvature,
jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints
with or without grooves (thickness of joints except at sharp curve shall not to more
At the sides of paver blocks
14 16.69 than 5mm), including making drainage opening wherever required complete etc. Cum 4.00 8,613.55 34,454.20
along the boundary wall
as per direction of Engineer-in-charge (length of finished kerb edging shall be
measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-
Providing and laying at or near ground level factory made kerb stone of M-25
grade cement concrete in position to the required line, level and curvature,
jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints
with or without grooves (thickness of joints except at sharp curve shall not to more
1 16.69 than 5mm), including making drainage opening wherever required complete etc. Cum 15.00 8,613.55 1,29,203.25
as per direction of Engineer-in-charge (length of finished kerb edging shall be
measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-
15 16.3 Supplying and stacking at site.
Supplying and stacking of well decayed cattle manure at site including
16 2.26 royalty and carriage upto 5 k.m.lead complete (Cattle manure measured in CUM 164 247.5 40,590.00
stacks will reduced by 8% for Payment).
Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marry
palmar, Cherry Blossom etc. well developed with fresh & healthy bushy in
full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of the
officer-in-charge.
Providing and stacking winter seasonal seedlings/cuttings at site of work well
18 10.1 developed and healthy free from disease in per tray and each tray having 100 Nos
plants as per direction of the officer-in-charge.
10.1.22 Nasturtium Each 70 500 35,000.00
SITC for Bollards: LED150, Warm White, PSU 220-240V
SITC for Light poles with fixtures : Light fixture IP65 post top lantern with symmetric
MR light distribution and limited upward with suitable mounting pole - 3 m High , rust No 25.00 20,000.00 5,00,000.00
resistant, stainless steel complete
MR SITC for Landscape/ tree uplighter: Description: Led,12-Watt COB Garden Spike No 15.00 1,700.00 25,500.00
MR Supply and installation of Wall Uplighter for highlighting the External Boundary wall No 15.00 2,200.00 33,000.00
Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10
metrenheight, backing filled with a grout of average 12 mm thick cement mortar
1:3 (1cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1
white cement : 2 stone dust) with an admixture of pigment matching the stone
shade :(To be secured to the backing and the sides by means of cramps and pins
shall be paid for separately) :
Red sand stone - exposed face fine dressed with rough backing.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or
more (thickness to be specified by the manufacturer), of 1st quality conforming to
IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Tiles in UG Water Tank+ Fire
Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse Fighting tank
sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints
with white cement and matching pigments etc., complete.
Digitally signed by SANJAY
Providing and applying integral crystalline slurry of hydrophilic in nature for
waterproofing treatment to the RCC structures like retaining walls of the basement,
water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels
/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts
integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts
integral crystalline slurry : 1 part water) for horizontal surfaces and applying the
same from negative (internal) side with the help of synthetic fiber brush. The
material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by
reducing permeability of concrete by more than 90% compared with control
concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative
side. The crystalline slurry shall be capable of self-healing of cracks up to a width of
0.50mm. The work shall be carried out all complete as per specification and the
direction of the engineer-in-charge. The product performance shall carry
guarantee for 10 years against any leakage.
22.23.1 For vertical surface two coats @ 0.70 kg per sqm sqm 150.00 406.25 60,937.50
22.23.2 For horizontal surface one coat @1.10 kg per sqm. sqm 50.00 311.05 15,552.50
Providing and laying flamed finish Granite stone flooring in required design and
patterns, in linear as well as curvilinear portions of the building all complete as per
the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick
5 11.55 base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with Steps & common area
cement slurry and pointing with white cement slurry admixed with pigment of
matching shade including rubbing, curing and polishing etc. all complete as
specified and as directed by the Engineer-in-Charge :
Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or
6 MR SITC of Advnace light arrestor with foundation and all required items needed Nos. 2.00 2,200.00 4,400.00
Cleaning of drinking water Ug Tank along with Fire fighting tank with non harardous
chemicals and biocleners
8 MR One time repair of existing motors, pipes in water, drain, fire system Quotation 1job 1.00 2,00,000.00 2,00,000.00
9 MR Shifting of DG set, Reassembling , repair and Testing of existing Dg set Quotation 1job 1.00 2,00,000.00 2,00,000.00
10 MR SHIFTING OF DG SYSTEM INCLUDING CABLES AND PANEL COST Quotation 1job 1.00 2,00,000.00 2,00,000.00
11 MR SHIFTING OF ELECTRICITY METERS Quotation 1job 1.00 5,00,000.00 5,00,000.00
Supply,installation, testing and commitioning of Water Softener system for both
13 MR NEW MAIN GATES (SS or in MS) for old gate and new gate proposed 2 Gates kg 700.00 841.48 5,89,038.51
14 MR Boom Barrier
Boom Length in 2.75 mtr. LED Type Boom, LED Connectivity
Options., Automatic Barrier Feature:
Barriers Hydraulic barrier (Right /Left Version)with boom
Opening/ Closing Time – 4-5 Sec. Fully.
Automatic with use cycles 100% with push button, Four J
hooks, Foundation plate. Round Boom. Push Button.
BARRIER MODEL 630 STD
Power supply (Vac / Hz) 230 {+6%/ -10%} / 50
Absorbed power (W) 220
Absorbed current (A) 1
Type of oil FAAC HP OIL
Oil quantity (Lt) ~ 1.8 , Barrier weight – 73 Kg
Winding heat protection (°C) 120
Anti-crushing system standard by-pass valves
Type of slow-down Electronic
Operating ambient temperature (°C) -20 / +55
Hood protective treatment Catachresis AISI 316 L
Protection class IP 44
Body Dimensions 390,290, 200,94
Photocell (Safety Beam Sensor) nos 2.00 2,63,813.72 5,27,627.45
SITC of above items
Supply and instalation of SIDBI Logo of appropriate size as per architect/ engineer
in charge over the top of Fascade visi
Digitally signed by SANJAY
Providing and fixing double scaffolding system (cup lock type) on the exterior side
of building/structure, up to 25 metre height, above ground level, including
additional rows of scaffolding in stepped manner as per requirement of site, made
with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical
tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps
and staircase system in the scaffolding for working platform etc. and maintaining it
in a serviceable condition for execution of work of cleaning and/ or pointing and/
or applying chemical and removing it thereafter.
The scaffolding system shall be stiffened with bracings, runners, connecting with the
building etc, wherever required, if feasible, for inspection of work at required
locations with essential safety features for the workmen etc., complete as per
directions and approval of Engineer-in-charge.
Note :- (1) The elevational area of the scaffolding shall be measured for payment
(2) The payment will be made once only for execution of all items for such works. Sqm 450.00 285.00 1,28,250.00
Chipping of unsound/weak concrete material from slabs, beams,
columns etc. with manual Chisel and/ or by standard power driven percussion
type or of approved make including tapering of all edges, making square
shoulders of cavities including cleaning the exposed concrete surface and
reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all
complete as per direction of Engineer-In-Charge
26.28.2 50mm average thickness Sqm 3,600.00 211.55 7,61,580.00
Providing and injecting approved grout in proportion recommended by the
manufacturer into cracks/honey-comb area of concrete/ masonry by suitable
2 26.35 gun/pump at required pressure including cutting of nipples after curing etc.
complete as per directions of Engineer-in- Charge. (The payment shall be made on
the basis of actual weight of approved grout injected.)
26.35.3 Epoxy injection grout in concrete/RCC work of approved make KG 1,000.00 793.25 7,93,250.00
Providing, erecting, maintaining and removing temporary protective screens made
3 26.36 out of specified fabric with all necessary fixing arrangement to ensure that it
remains in position for the work duration as required by the Engineer-in-charge.
Cleaning of exposed concrete surface of sticking material including loose and
4 26.37 foreign material by sand blasting with coarse sand followedby and including sqm 500.00 370.15 1,85,075.00
cleaning with oil free air blast as per direction of Engineer in charge.
Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design
mix concrete having the specified minimum characteristic compressive strength
[with ordinary portland cement, coarse sand and graded stone aggregate of 10
mm maximum size in proportion as per design criteria] including the cost of
centering and shuttering at edges and corners etc. as directed by Engineerin-
Charge Note: Rates shall include the providing necessary ground wires etc.
The levelling gauges, if used, shall be paid for separately. Payment
under this item shall be made only after proper wet curing has been done and
surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal
26.38.2 50mm thick in Grade M 25 with cement content not less than 330 kg per cum sqm 417.00 1,073.45 4,47,628.65
Providing and inserting 12mm dia galvanised steel injection nipple in honey comb
area and along crack line including drilling of holes of required diametre (20mm to
30mm) up to depth from 30mm to 80mm at required spacing and making the hole
& crack dust free by blowing compressed air, sealing the distance between
injection nipple with adhesive chemical of approved make and allow it to cure
complete as per direction of Engineer-In-Charge.
Providing and fixing hard drawn steel wire fabric of size 75 x25 mm
mesh or other suitable size wire mesh to be fixed & firmly anchored
7 26.40 to the concrete surface by means of "L" shaped mild steel shear key welded with sqm 417.00 820.80 3,42,273.60
existing reinforcement including the cost of materials, labour, tool & plants as
approved by Engineer-in-charge.
Digitally signed by SANJAY
Providing and laying non-pressure NP2 class (light duty) R.C.C.
pipes with collars jointed with stiff mixture of cement mortar in the
proportion of 1:2 (1 cement : 2 fine sand) including testing of joints
etc. complete :
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom
and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside
cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand)
finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1
cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and
making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size) finished with a floating coat of neat
cement, all complete as per standard design :
0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation)
560 mm internal diameter conforming to I.S. 12592, total weight of cover and
frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering,
shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at
the external surface shall be paid for separately) :
19.9.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 15.00 11,886.45 1,78,296.75
11 19.9.1.2 With Sewer bricks conforming to IS : 4885 each 20.00 11,666.90 2,33,338.00
Preparation of complete set of shop drawings including finishing, MEP services,
details, design calcualtions etc. and any other details as and when desired by
Engineer In charge /client. A qualified professsional for the purpose shall be
appointed after due appproval from Engineer In Charge.
Repair and maintenance of mislaneous items on site unearthed during the
restoration and revitalization process.
Digitally signed by SANJAY
SUMMARY OF 2 BHK Block (28 Flats) Works
DESCRIPTION OF ITEM DSR AMOUNT NSDR AMOUNT REMARKS
2 ELECTRICAL WORKS 5892449.00 3507627.58
3 PLUMBING WORKS 1415254.31 91009.26
INCLUDING SOLAR PANELS,
LIFTS, SS RAILINGS,
GRAND TOTOL FOR 28 FLATS 2 BHK 59606409.78 FLOORING OF COMMON
WATERPROOFING OF
PER 2 BHK FLAT COST 2128800.35
SUMMARY OF 3 BHK Block (8 Flats) Works
DESCRIPTION OF ITEM DSR AMOUNT NSDR AMOUNT REMARKS
2 ELECTRICAL WORKS 3127663.00 1763338.34
3 PLUMBING WORKS 661843.14 91014.43
INCLUDING SOLAR PANELS,
GRAND TOTOL FOR 8 FLATS 3 BHK 28676555.84 LIFTS, SS RAILINGS,
FLOORING OF COMMON
WATERPROOFING OF
PER 3 BHK FLAT COST 3584569.48
Sl No DSR No Description of Item Unit Quantity DSR Rate (Rs) Amount(Rs) MarketRate (Rs) Amount(Rs)
Demolishing brick work manually/ by mechanical means including
1 15.7 stacking of serviceable material and disposal of unserviceable material
within 50 metres lead as per direction of Engineer-in-charge..
15.7.4 In cement mortar opening kitchen wall Cum 40.57 1,698.45 68,910.00
Dismantling doors, windows and clerestory windows (steel or wood)
2 15.12 shutter including chowkhats, architrave, holdfasts etc. complete and
stacking within 50 metres lead :
15.12.1 Of area 3 sq. metres and below No. 252.00 302.70 76,280.00
Dismantling tile work in floors and roofs laid in cement mortar including
stacking material within 50 metres lead
3 15.23.1 15.23.1 For thickness of tiles 10 mm to 25 mm 1680 60.50 1,01,640.00
Dismantling old plaster or skirting raking out joints and cleaning the
4 15.56 surface for plaster including disposal of rubbish to the dumping ground Sqm 3,438.00 45.05 1,54,882.00
within 50 metres lead.
Dismantling of cement concrete platform along with curtain walls and
5 15.55 base concrete etc. including stacking of useful materials near the site
and disposal of unserviceable materials within 50 metres lead :
Removing dry or oil bound distemper, water proofing cement paint
6 13.91 and the like by scrapping, sand papering and preparing the surface Sqm 6,050.00 20.85 1,26,143.00
smooth including necessary repairs to scratches etc. complete.
Dismantling C.I. pipes including excavation and refilling trenches after
taking out the pipes, manually/ by mechanical means breaking lead
7 15.45 caulked joints, melting of lead and making into blocks including
stacking of pipes & lead at site within 50 metre lead as per direction of
Engineer-in-charge:
Dismantling asbestos cement pressure pipes including excavation and
refilling trenches after taking out the pipes manually/ by mechanical
means and stacking the pipes within 50 metres lead as per direction of
Engineer-in-charge :
Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China)
9 15.52 including stacking of useful materials near the site and disposal of No. 56.00 744.60 41,698.00
unserviceable materials within 50 metres lead.
Disposal of building rubbish / malba / similar unserviceable, dismantled
or waste materials by mechanical means, including loading,
10 15.60 transporting, unloading to approved municipal dumping ground or as Cum 1,000.00 219.35 2,19,350.00
approved by Engineer-in-charge, beyond 50 m initial lead, for all leads
including all lifts involved.
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating
coat of neat cement.(External)
Extra for plastering exterior walls of height more than 10 m from ground
level for every additional height of 3 m or part thereof.
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5
sq.meters and under, including cutting the patch in proper shape,
14 14.1 raking out joints and preparing and plastering the surface of the walls
complete, including disposal of rubbish to the dumping ground, all
complete as per direction of Engineer-in-Charge
With cement mortar 1:4 (1cement: 4 coarse sand)with chiken mesh/
Digitally signed by SANJAY
Extra for providing and mixing water proofing material in cement
plaster work in proportion recommended by the manufacturers.
Providing and laying vitrified floor tiles in different sizes (thickness to be
specified by the manufacturer) with water absorption less than
0.08%and conforming to IS : 15622 , of approved make, in all colours
15 11.41 and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4
coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including
grouting the joints with white cement and matching pigments etc.,
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300
mm or more (thickness to be specified by the manufacturer), of 1st
quality conforming to IS : 15622, of approved make, in all colours,
16 11.40 shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm Sqm 252.00 1,225.10 3,08,725.00
thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey
cement slurry @ 3.3kg/sqm including pointing the joints with white
cement and matching pigments etc., complete.
13.6 20 mm cement plaster of mix :
Providing and laying water proofing treatment in sunken portion of
WCs, bathroom etc., by applying cement slurry mixed with water
proofing cement compound consisting of applying : a) First layer of
slurry of cement @ 0.488 kg /sqm mixed with water proofing cement
compound @ 0.253 kg/sqm. This
17 22.5 layer will be allowed to air cure for 4 hours. b) Second layer of slurry of SQM 252 516.6 1,30,183.00
cement @ 0.242 kg/ sqm mixed with water proofing cement
compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4
hours followed with water curing for 48 hours. The rate includes
preparation of surface, treatment and sealing of all joints, corners,
junctions of pipes and masonry with polymer mixed slurry.
FOAM CONCRETE FILLING UNDER TOILETS AND PANTRY:- Filling and
compacting Foam Concrete for raising level of toilets and pantry and
18 finishing in a coat of lean concrete screeding with waterproofing CUM 75.6 5,524.91 4,17,683.00
compound complete in all respects to take Tile Flooring as per flooring
specifications.
TILE DADO :- Providing and fixing Ist quality ceramic glazed wall tiles
conforming to IS: 15622 (thickness to be specified by the
manufacturer), of approved make, in all colours, shades except
burgundy, bottle green, black of any size as approved by Engineer-in-
Charge, in skirting, risers of steps and dados, over 12 mm thick bed of
cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey
cement slurry @ 3.3kg per sqm, including pointing in white cement
mixed with pigment of matching shade complete.
Providing and fixing 18 mm thick gang saw cut, mirror polished,
premoulded and prepolished, machine cut for kitchen platforms,
vanity counters, window sills, facias and similar locations of required size,
approved shade, colour and texture laid over 20 mm thick base
cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white
cement, mixed with matching pigment, epoxy touch ups, including
rubbing, curing, moulding and polishing to edges to give high gloss
finish etc. complete at all levels
8.2.2 Granite stone slab colour black, Cherry/Ruby red Sqm 112.00 4,425.35 4,95,639.00
Providing edge moulding to 18 mm thick marble stone counters,
21 8.3 Vanitiesetc., including machine polishing to edge to give high gloss
finish etc. complete as per design approved by Engineer-in-Charge.
8.3.2 Granite work metre meter 112.00 418.85 46,911.00
Digitally signed by SANJAY
Providing and laying Polished Granite stone flooring in required design
and patterns, in linear as well as curvilinear portions of the building all
complete as per the architectural drawings with 18 mm thick stone slab
over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4
coarse sand) laid and jointed with cement slurry and pointing with
white cement slurry admixed with pigment of matching shade
including rubbing, curing and polishing etc. all complete as specified
and as directed by the Engineer-in-Charge
Polished Granite stone slab colour of Black, Cherry/Ruby
Red or equivalent
Three track three panels sliding window with fly proof SS wire mesh (Two
nos. glazed & one no. wire mesh panels) made of (small series) frame
23 9.147D.2 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 Sqm 336.00 10,030.30 33,70,181.00
mm and single glazing bead of appropriate dimension (Area of
window up to 1.75 sqm).
Casement window single panel with S.S. friction hinges (300 x 19 x 1.9
mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both
having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing
bead of appropriate dimension. (Area of window up to 0.75 sqm.)
Providing and applying white cement based putty of average
thickness 1 mm, of approved brand and manufacturer, over the
plastered wall surface to prepare the surface even and smooth
complete. (Internal Walls)
Applying priming coats with primer of approved brand and
manufacture, having low VOC (Volatile Organic Compound ) content.
With water thinnable cement primer on wall surface
having VOC content less than 50 grams/litre
Wall painting with premium acrylic emulsion paint of interior grade,
having VOC (Volatile Organic Compound ) content less than 50
grams/ litre. of approved brand and manufacture, including applying
additional coats wherever required to achieve even shade and colour.
Providing and applying white cement based putty of average
thickness 1 mm, of approved brand and manufacturer, over the
plastered wall surface to prepare the surface even and smooth
Applying priming coats with primer of approved brand and
manufacture, having low VOC (Volatile Organic Compound ) content.
Finishing walls with Acrylic Smooth exterior paint of required shade :
New work (Two or more coat applied @ 1.67 ltr/10 sqm
over and including priming coat of exterior primer applied
14.14.1 Red/ white sand stone slabs 30 to 50 mm thick. Sqm 126.00 1,099.15 1,38,493.00
Providing and fixing stainless steel ( Grade 304) railing made of Hollow
tubes, channels, plates etc., including welding, grinding, buffing,
polishing and making curvature (wherever required) and fitting the
same with necessary stainless steel nuts and bolts complete, i/c fixing
the railing with necessary accessories & stainless steel dash fasteners ,
stainless steel bolts etc., of required size, on the top of the floor or the
side of waist slab with suitable arrangement as per approval of
Engineer-incharge, (for payment purpose only weight of stainless steel
members shall be considered excluding fixing accessories such as nuts,
bolts, fasteners etc.).
Digitally signed by SANJAY
Providing and laying in situ seven course water proofing treatment with
APP (Atactic Polypropylene) modified Polymeric membrane over roof
consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th &
6th courses of bonding material @ 1.20 kg/sqm, which shall consist of
blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th
layers of roofing membrane APP modified Polymeric membrane 2.0
mm thick of 3.00 Kg/sqm weight consisting of five layers prefabricated
with centre core as 100 micron HMHDPE film sandwiched on both sides
with polymeric mix and the polymeric mix is protected on both side
with 20 micron HMHDPE film.
7th, the top most layer shall be finished with brick tiles of class
designation 10 grouted with cement mortar 1:3 (1 cement : 3 fine sand)
mixed with 2% integral water proofing compound by weight of cement Sqm 450.00 732.75 3,29,738.00
over a 12 mm layer of cement mortar 1:3 ( 1 cement : 3 fine sand) and
finished neat (item of laying brick tiles shall be paid for separately).
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate) finished with a floating coat of neat cement,
including cement slurry, but excluding the cost of nosing of steps etc.
11.3.1 40 mm thick with 20 mm nominal size stone aggregate sqm 450.00 545.00 245250
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20
mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and
initial emittance > 0.75 on waterproof and sloped surface of terrace,
laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement :
4 coarse sand) and grouting the joints with mix of white cement &
marble powder in ratio of 1:1, including rubbing and polishing of the
surface upto 3 cuts complete, including providing skirting upto 150 mm
height along the parapet walls in the same manner.
Providing and fixing double scaffolding system (cup lock type) on the
exterior side of building/structure, up to 25 metre height, above ground
level, including additional rows of scaffolding in stepped manner as per
requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre
35 24.2 centre to centre, horizontal & vertical tubes joint with cup & lock system
with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in
the scaffolding for working platform etc. and maintaining it in a
serviceable condition for execution of work of cleaning and/ or
pointing and/ or applying chemical and removing it thereafter.
The scaffolding system shall be stiffened with bracings, runners,
connecting with the building etc, wherever required, if feasible, for
inspection of work at required locations with essential safety features
for the workmen etc., complete as per directions and approval of
Engineer-in-charge.
Note :- (1) The elevational area of the scaffolding shall be measured
for payment purpose.
(2) The payment will be made once only for execution of all items for
Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to
a height of 5 m above floor level, over first class kail wood strips 25x6
mm with 10 mm gap in between and reinforced with rabbit wire mesh
fixed to wooden frame (frame work to be paidseparately):
Extra for sunk or raised mouldings in the plaster of Paris (Gypsum
anhydrous) ceiling.
Providing wood work in frames of doors, windows, clerestory windows
and other frames, wrought framed and fixed in position with hold fast
lugs or with dash fasteners of required dia & length (hold fast lugs or
dash fastener shall be paid for separately). Second class teak wood
Digitally signed by SANJAY
Providing and fixing ISI marked flush door shutters conforming to IS :
2202 (Part I) decorative type, core of block board construction with
frame of 1st class hard
39 9.20.1 wood and well matched teak three ply veneering with vertical grains Sqm 262.50 3,086.10 8,10,101.00
or crossbands and face veneers on both faces of shutters.35 mm thick
Fixing with hinges of required size and necessary screws
(Note: Hinges and necessary screws hall be paid separately
SITC Stainless steel SS-304 kitchen sink - with drain board 510 x 1040 mm
bowl depth 250 mm
Providing and fixing bright /matt finished Stainless Steel handles of
approved quality & make with necessary screws etc all complete.
Providing and fixing bright finished brass 100 mm mortice latch with one
dead bolt and a pair of lever handles of approved quality with
necessary screws etc. complete.
Providing and fixing modular kitchen units for the kitchen platform and
top wall units to be fabricated by using HDHMR board of thickness 18
mm for making cabinets of required sizes to match with the sizes SS
kitchen jali units and size of the SS sink as per following details:-
Front , bottom , top , sides and shelf partitions of the modular cabinets
shall be of 18 mm thick HDHMR boards of M/s Green panel Industries or
approved equivalent and back portion shall be of 8 mm thick HDHMR
board or approved equivalent with necessary fittings , screws , pasting
materials, finishing all exposed cut surfaces with self adhesive PVC tape
in matching shade as that of laminate . The shutters and the pull out
units shall be fixed 50 mm above the kitchen floor level . All the inner
portions of the cabinets shall be finished with 0.8 mm thick laminate of
white colour and approve make .. The front face of the cabinet shall
be finished with1 .0 mm ultra gloss laminate shade 21162 MR+ & 21069
MR+ Merino make The fittings like handles , telescopic channels , SS
baskets , auto closing hinges shall be paid separately under respective
items below. Quoted rates shall be inclusive of labour , materials ,
wastage , scaffolding , fixing arrangements of top and bottom units
with necessary dash fasteners , repairing the damages, shifting the
debris out of colony , CP , taxes etc all as required for the execution of
the work . Note :-Only front elevation area shall be measured for
payment purpose,
Top wall units of depth 300 mm approx. with shelves Sqm 105.00 18,000.00 18,90,000.00
Providing and fixing stainless steel baskets and other fittings, accessories
43 MR of modular kitchen of M/s Hettich or approved equivalent make as per each 224.00 3,000.00 6,72,000.00
below mentioned details :-
Complete Dismantling of internal wiring, switch boards change of
internal Wiring along with Switchboards, fans lights and etc
#REF! MR Dismantling of Water Tank over the roof with proper disposal of parts each 4.00 10,000.00 40,000.00
Providing and placing on terrace (at all floor levels) polyethylene
water storage tank, IS : 12701 marked, with cover and suitable locking
arrangement and making necessary holes for inlet, outlet and overflow
pipes but without fittings and the base support for tank.
Complete dismantling of lifts along with disposal of old machine parts
as per Engineer incharge
Digitally signed by SANJAY
TV Cabinet Unit- in 18 mm HDHMR ply of size 1500mm x 1200 mm having
setup box holder, size 1200 mm x 200 mm placed 100 mm from bottom
#REF! MR of TV unit. All side with 2mm laminate of approved colour and provision Sqm 74.20 11,472.00 8,51,222.40
of 6/16 Amp socket at top, TV cable with switch plate. Two numbers of
n6/16 Amp socket with control switch above set up box
Low side Airconditioning works including chasing, Copper piping,
insulation of copper pipe, and repairing of chased area with cement
and mortar wherever required to match existing plastered surface.
#REF! MR Specified brand for insulation Superlon with wall thickness of minimum rmt 800.00 1,050.00 8,40,000.00
13mm. SPecified brand for copper piping. Only One (1) length
between indoor and outdoor unit shall be measured for payment.
Low side Airconditioning works including chasing, laying of drain pipe,
sealing of all joints, and repairing of chased area with cement and
mortar wherever required. For drain piping Supreme UPVC pipes of
10KGF to be used. Of 25mm Diameter.
Interconnecting cable for AC units between indoor & Outdoor untis
#REF! MR SITC Of chimney for kitchen. nos. 28.00 12,000.00 3,35,999.89
#REF! MR SITC of wardrobe as per design and detail. nos. 56.00 80,000.00 44,80,000.00
#REF! MR SITC of 20L gyeser nos. 56.00 12,000.00 6,71,999.79
#REF! MR SITC of 3L gyeser nos. 28.00 5,000.23 1,40,006.39
CEILING PELMETS :- Providing and fixed pelmet of overall size
150mmx150mm and made hardwood framings hung from ceiling
#REF! MR @1000mm centre to centre with 2 nos of 6mm thk. Commercial ply on rmt 28.00 1,425.14 39,903.91
vertical & 12mm thk. Commercial ply on horizontal surface (straight &
curved). Inclusive of finishing in Paint.
#REF! MR SITC of concealed door closer Nos. 28.00 6,241.99 1,74,775.68
#REF! MR SITC of Curtain Rod m 28.00 643.77 18,025.43
SITC of SS-304 Steel Safety Main door, with inetrnal SS-304 Mosquito
Mesh, with heavy duty interlock
1 SOLAR PANELS
Supply, Installation, Testing and Commissioning of on grid Solar
of Rates & Delhi
Photovoltaic Power Plant conforming to MNRE specifications as
amended, consisting of Mono/ Poly Crystalline silicon solar cells, net
metering facility, necessary protections, earthing, mounted on
(Item for Solar
Aluminium/ GI structure of suitable strength with following components
complete as required:-
a)Solar Photo voltaic Module of capacity 330W por above,
manufactured in India, conforming to IS 14286/ IEC61215, IS/ IEC61730 -
Part - 1, IS/IEC61730 - Part - 2. Solar Photo voltaic Module conversion
efficiency shall not be less than 16.5%. PV modules used in solar power
plants / systems must be warranted for their output peak watt capacity
,which should not be less than 90% at the end of 10 years and 80% at
the end of 25 years.
b)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range
and 400 V AC, three phase, 4 wire, 50 Hz+/- 2.5Hz, output voltage
suitable to generate AC Power with efficiency not less than 97%, total
harmonic distortion less than 3% and suitable for ambient temperature
from 0 to 50 degree C. The PCU shall adjust the voltage and frequency
level to suit the Grid Voltage Frequency.
c) Data Monitoring System complete with accessories.
d) Fixing of Array junction box & Main junction box with IP65 protection
and termination arrangement for incoming and out going cable along
with glands, lugs and other accessories etc. as required.
e) Lightning and surge voltage protection.
Digitally signed by SANJAY
f) Connections & Interconnections by supplying & fixing required size
XLPE insulated copper conductor 1.1kV grade armoured power and
control cables between solar modules, main power cable to grid kWp 20.00 76,325.00 15,26,500.00
supply PCU unit along with supplying & fixing of necessary channel/
conduit lugs and other accessories etc. as required.
WIRING IN STEEL
DSR NO/MR Sub Head 1 : WIRING IN STEEL AND PVC CONDUIT
Wiring for light point/ fan point/ exhaust fan point/ call bell
point with 1.5 sq.mm FRLS PVC insulated copper conductor
single core cable in surface / recessed medium class PVC conduit, with
modular switch, modular plate, suitable GI box and earthing the
point with 1.5 sq.mm FRLS PVC insulated copper conductor
single core cable etc. as required.
Wiring for group controlled (looped) light point/fan point/exhaust fan
point/ call bell point (without independent switch etc.) with 1.5 sq. mm
2 1.55 FRLS PVC insulated copper conductor single core cable in surface/
recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC
insulated copper conductor single core cable etc. as required.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface /
recessed medium class PVC conduit, 2 way modular switch, modular
suitable GI box and earthing the point with 1.5 sq.mm FRLS
PVC insulated copper conductor single core cable etc. as
Wiring for circuit/ submain wiring alongwith earth wire with the following
4 1.14 sizes of FRLS PVC insulated copper conductor, single core cable in
surface/ recessed medium class PVC conduit conduit as required.
Supplying and drawing following pair 0.5 mm dia FRLS PVC
insulated annealed copper conductor, unarmored telephone
cable in the existing surface/ recessed steel/ PVC conduit as
Supplying and drawing co-axial TV cable, 0.7 mm
solid copper conductor PE insulated, shielded with fine tinned copper
braid and protected with PVC sheath in the existing surface/ recessed
steel/ PVC conduit as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the
existing surface/ recessed Steel/ PVC conduit as required.
Digitally signed by SANJAY
Supplying and fixing of following sizes of medium class PVC
conduit along with accessories in surface/recess including
cutting the wall and making good the same in case of recessed
conduit as required.
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated
9 annealed copper conductor, armored telephone cable as required
similar to Skytone or equivalent.
Supplying and fixing two module stepped type electronic fan
10 1.25 regulator on the existing modular plate switch box including 168.0 Each 369.00 61,992.00 0.00
connections but excluding modular plate etc. as required.
Supplying and fixing following modular switch/ socket on the existing
11 1.24 modular plate & switch box including connections but excluding
modular plate etc. as required.
c 1.24.6 Telephone socket outlet 84.0 Each 148.00 12,432.00 0.00
d 1.24.7 TV antenna socket outlet 84.0 Each 148.00 12,432.00 0.00
RJ 45 Socket For Internet Similar to Legrand Cat Ref. 673155 or
Supplying and fixing following size/ modules, GI box alongwith modular
base & cover plate for modular switches in recess etc. as required.
Supplying and fixing suitable size GI box with modular plate
and cover in front on surface or in recess, including providing and fixing
3 pin 5/6 A modular socket outlet and 5/6 A modular switch,
connections etc. as required.
Supplying and fixing suitable size GI box with modular plate
and cover in front on surface or in recess, including providing
and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and
15/16 A modular switch, connections etc. as required.
Supplying & fixing suitable size GI box wih modular plate and cover in
front on surface or in recess including providing and fixing 25 A modular
socket outlet and 25 A modular SP MCB, “C” curve including
connections, painting etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V,
complete as required.
Installation, testing and commissioning of ceiling fan, including wiring
17 1.44 the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS 168.0 Each 213.00 35,784.00 0.00
PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making
good the damage, connection, testing,commissioning etc. as required.
Extra for fixing the louvers/ shutters complete with frame for a exhaust
fan of all sizes.
Digitally signed by SANJAY
Supply, installation, testing & commissioning of following size Telephone
KG Krone Box with hing door and mounting accessories as required.
Supply Installation testing and commissioning of Pach panel for internet
of following port with all additional accessories as required.
Supply Installation Testing & Commissioning of 2U Wall Mountable
24 MR powder coted Rack with 3x5A Power Manager, 1 position fan, min 2 7.0 Each 5,400.00 0.00 37,800.00
nos of shelf, Front Glass door with Lock & key at respective floor.
25 MR Supply, installation, testing & commissioning of TV Splitter Box. 28.0 Each 860.00 0.00 24,080.00
Sub Head 2 : DBs & MCBs
Supplying and fixing following way, single pole and neutral, sheet steel,
MCB distribution board, 240 V, on surface/ recess, complete with tinned
1 2.3 copper bus bar, neutral bus bar, earth bar, din bar, interconnections,
powder painted including earthing etc. as required. (But without
MCB/RCCB/Isolator)
Supplying and fixing 240/415 V, 10 kA, “C” curve, miniature circuit
breaker suitable for inductive load of following poles in the existing
MCB DB complete with connections, testing and commissioning etc. as
b 2.10.3 5 to 32 Amp. Double pole 28.0 Each 656.00 18,368.00
Providing and fixing M.V. danger notice plate of 200 mm X 150
mm, made of mild steel, at least 2 mm thick, and vitreous
enameled white on both sides, and with inscription in single red colour
on front side as required.
Sub Head 3 : Surface/Recess Luminaire
Supplying installation testing and commissioning Recess/Surface Mount
Downlighter Mollis Recess Downlighter 15W LED complete in all respect.
4 MR (RA-9) Supplying of 1200mm sweep ceiling fan (BLDC) 168.0 Each 3,214.63 5,40,057.10
Supplying installation testing and commissioning of 450mm sweep 1500
RPM heavy Duty Exhaust Fan .
6 MR Supplying installation testing and commissioning of 20W LED TUB LIGHT 84.0 Each 1,190.52 1,00,003.34
Sub Head 1 : Earthing
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including
accessories, and providing masonry enclosure with cover plate having
locking arrangement and watering pipe of 2.7 meter long etc. with
charcoal/ coke and salt as required.
Digitally signed by SANJAY
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including
accessories, and providing masonry enclosure with cover plate having
2 5.2 locking arrangement and watering pipe etc. with charcoal/coke and 16.0 Each 6,855.00 1,09,680.00 0.00
salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter
below ground as strip earth electrode, including connection/
3 5.9 terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing 30.0 Meter 144.00 4,320.00 0.00
shall be done by overlapping and with 2 sets of G.I. nut bolt & spring
washer spaced at 50 mm)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from
4 5.11 earth electrode including connection with G.I. nut, bolt, spring, washer 500.0 Meter 706.00 3,53,000.00 0.00
excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in
recess for connections etc. as required.
Sub Head 2 : Panel, Cable & End Termination
BUILDING L.T PANEL
The Main LT Panel shall use all draw out type breakers suitable for 415 V
AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. The panel shall have
AMF facility to achieve electrical interlocking, synchronizing,
buscoupler switching, auto operation of incommer and bus coupler,
auto start of D.G. Sets, auto D.G. running by pre set timing, auto
changeover etc and having following incomming and outgoing Air
Circuit Breakers, FSU's as per the drawing and specification.interlocking,
buscoupler switching, auto operation of incommer and bus coupler,
1 MR auto start of D.G. Sets, auto D.G. running by pre set timing, auto 1.0 Set 3,25,000.07 3,25,000.07
changeover etc and having following incomming and outgoing Air
Circuit Breakers, FSU's as per the drawing and specification.Each
incoming breaker will have microprocessor based releases and all
outgoing breaker will have minimum electrostatic releases or mention
as mention in BOQ. The Panel will be made as per detailed
specifications & drawings forming part of this document. Fault level of
panel shall be 35 MVA.
2 Nos. 160 Amp FP MCCB
1 Nos. 200 Amp TPN busbars of aluminium alloy as per SLD.
AUTO OPERATION OF INCOMER / BUSCOUPLER ACB's.
Load Management through PLC
Contactor for Load Management System
Buscoupler switching.
4 Nos. 63 Amp TP MCB
30 Nos. 40Amp DP MCB
2 sets of multifunction meter with parameter
current,voltage,KWH,KVAH,Power factor on incoming from transformers.
2 Sets of phase indicating lights (RYB) with protection fuses (one set for
each incoming breaker).
2 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming
2 Sets auto trip indicating lamp .
Note: All outgoings should have ammeter and RYB indications with
backup MCB as indicated in single line diagrams.
30 Nos. Single Phase Energy Meter
Digitally signed by SANJAY
UNDER GROUND CABLES
Supply of 3.5core and 4 core 1.1 KV LT power cable with
solid/stranded compacted aluminium conductor, XLPE insulated colour
7 coaded, Laid up, PVC inner shethed armoured with single layer of
galvenized round wire or flat strip and over all ST-2 Grade PVC shethed
conforming to IS 7098 (part-1) and ISI marked.
Laying of one number PVC insulated and PVC sheathed / XLPE power
cable of 1.1 kV grade of following size direct in ground including
8 7.3 excavation and refilling the trench etc. as required, but excluding sand
cushioning and protective covering.
b 7.3.2 Above 35 sq. mm and upto 95 sq. mm 250.0 Meter 217.00 54,250.00 0.00
Laying of one number PVC insulated and PVC sheathed / XLPE power
9 cable of 1.1 kV grade of following size in the existing RCC/ HUME/
METAL pipe as required.
b 7.5.2 Above 35 sq. mm and upto 95 sq. mm 100.0 Meter 57.00 5,700.00 0.00
Laying of one number PVC insulated and PVC sheathed / XLPE power
10 7.6 cable of 1.1 kV grade of following size in the existing masonry open
duct as required.
b 7.6.2 Above 35 sq. mm and upto 95 sq. mm 100.0 Meter 45.00 4,500.00 0.00
Laying and fixing of one number PVC insulated and PVC sheathed /
11 7.8 XLPE power cable of 1.1 kV grade of following size on cable tray as
a 7.6.3 Upto 35 sq. mm (clamped with 1mm thick saddle) 330.0 Meter 63.00 20,790.00 0.00
Above 35 sq. mm and upto 95 sq. mm (clamped with 25 x 3mm MS flat
END TERMINATION
Supplying and making cable end terminations with brass compression
gland and aluminium lugs for folowing sizes of 3.5 Core and 4 Core
12 PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1
KV grade, complete as required.
1 Providing and fixing white glazed earthen wate (European type) W.C.
PWD SOR 2022 Pan 580mm dia,(10 ltr) C.I. Flushing Cistern complete with G.I. Pull each 56.00 3,850.00 2,15,600.00
SI.No.(4+8+6) chain,M.S.Bracket of Engineer-in-Charge.(Standered size)
2 Providing & fixing white vitreous china wash basin with C.I. brackets
painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber
plug, 32mm C.P. brass waste of standerd pattern including cutting &
making good the walls wherever required.
a)White Vitreous China Wash basin size 630x450 mm with a pair of 15
mm C.P. brass pillar taps
Digitally signed by SANJAY
3 Providing and fixing white vitreous china flat back half stall urinal of size
580*380*350mm with white PVC automatic flushing cistern, with fittings,
standard size C.P. brass flush pipe, spreaders with unions and clamps
(all in D.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet
grating and other couplings in C.P. brass including painting of fittings
and cutting and making good the walls and floors wherever required:
Range of single half stall urinals with 5 litre PV.C. automatic flushing
17.5.1 cistern.
4 Providing and fixing P.V.C. waste pipe for sink or wash basin including
17.28 P.V.C. waste fittings complete.
17.28.1 Semi rigid pipe
5 Providing and fixing 600x450mm bevelled edge mirror of superior glass
(of approved quality) complete with 6mm thick hard board ground
fixed to wooden cleats with C.P. brass screws and washers complete.
6 Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per I.S.
13983 with C.I. brackets and stainless steel plug 40 mm including
painting of fittings and brackets, cutting and making good the walls
17.10 wherever required :
17.10.1 Kitchen sink with drain board
7 17.70 Providing and fixing PTMT Bottle Trap for Wash basin and sink
Bottle trap 38 mm single piece moulded with height of 270 mm,
effective length of tail pipe 260 mm from the centre of the waste
coupling, 77 mm breadth with 25 mm minimum water seal, weighing
17.70.2 not less than 263 gms
8 Providing and fixing PTMT towel rail complete with brackets fixed to
wooden cleats with CP brass screws with concealed fittings
17.73 arrangement of approved quality and colour.
600 mm long towel rail with total length of 645 mm, width 78 mm and
effective height of 88 mm, weighing not less than 190 gms. each 56.00 521.18 29,186.08
CP Brass fittings
9 Providing and fixing unplasticised PVC connection pipe with brass
18.21.2 45 cm length
10 Providing and fixing C.P. brass bib cock of approved quality
18.49 conforming to IS:8931
11 Providing and fixing C.P. brass long body bib cock of approved quality
conforming to IS standards and weighing not less than 690 gms.
12 Providing and fixing C.P. brass angle valve for basin mixer and gyser
18.53 points of approved quality conforming to IS:8931
13 18.22 Providing and fixing C.P. brass shower rose with 15 or 20mm inlet
Digitally signed by SANJAY
14 Providing and fixing C.P. brass stop cock (concealed) of standard
design and of approved make conforming to IS:8931:
18.52.1 15mm nominal bore each 4.00 516.32 2,065.28
1 Providing and fixing unplasticised-PVC pipe clips of approved design to
unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs,
screwed with MS screws of required length including cutting brick work
and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making
good the wall etc. complete.
2 Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand
: 10 graded stone aggregate 20mm nominal size) around P.V.C Soil
DSR no.19.2.1 and waste pipe including bed concrete as per standard
design(embedded in the flooring / ground)
3 Providing and fixing on wall face unplasticised-Rigid PVC rain water
pipes conforming to IS: 13592 Type A including jointing with seal ring
conforming to IS: 5382 leaving 10mm gap for thermal expansion.
4 Providing and fixing on wall face unplasticised PVC moulded
fittings/accessories for unplasticised Rigid PVC rain water pipes
conforming to IS:13592 Type A including jointing with seal ring
12.42 conforming to IS:5382 leaving 10mm gap for thermal expansion.
12.42.5.2 Bend 87.5 degree
12.42.6 Shoe (Plain)
5 Providing and fixing to the inlet mouth of rain water pipe cast iron
grating 15 cm diameter and weighing not less than 440 grams. Each 14.00 41.58 582.12
6 Providing and fixing unplasticised-PVC pipe clips of approved design to
unplasticised-PVC rain water pipes by means of 50x50x50 mm hard
wood plugs, screwed with MS screws of required length including
cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse
sand) and making good the wall etc. complete.
7 Making khurras 45x45 cm with average minimum thickness of 5 cm
cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400
micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse Each 14.00 231.44 3,240.16
sand) and a coat of neat cement,punning,rounding the edges and
making and finishing the outlet complete.
III INTERNAL WATER SUPPLY
1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m
spacing. This includes jointing of pipes & fittings with one step CPVC
solvent cement and the cost of cutting chases and making good the
same including testiang of joints complete as per direction of Engineer
Digitally signed by SANJAY
Concealed work including cutting chases and making good the walls
18.8.3 25mm dia nominal outer dia pipes Rm. 350.00 543.49 1,90,221.50
18.9.6 50mm dia nominal outer dia pipes Rm. 80.00 704.78 56,382.40
2 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step
CPVC solvent cement and testing of joints complete as per direction of
Engineer in Charge.
Internal work-Exposed on wall
18.7.2 20 mm nominal outer dia Pipes Metre 350.00 282.23 98,780.50
3 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m
spacing. This includes jointing of pipes & fittings with one step CPVC
solvent cement and the cost of cutting chases and making good the
same including testing of joints complete as per direction of Engineer in
Concealed work, including cutting chases and making good the walls
18.8.2 20 mm nominal outer dia Pipes Metre 180.00 446.00 80,280.00
4 Providing and fixing gun metal gate valve with wheel of approved
18.17 quality.
18.17.1 25mm dia nominal bore Each 11.00 462.15 5,083.65
17.17.4 50mm dia nominal bore Each 6.00 762.43 4,574.58
5 18.16 Providing and fixing brass stop cock of approved quality.
6 Providing and placing on terrace (at all floor levels)polyethylene water
storage tank ISI : 12701 marked indicating the BIS License No. with
cover and suitable locking arrangement and making necessary holes
for inlet, outlet and over flow pipes but without fitting and base support
for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI
18.48 license].
Capcity in Per Liters 25,000.00 8.42 2,10,500.00
TOTAL[III] 14,15,254.31
1 Providing and fixing in floor and wall face Ringfit UPVC Conventional
system for soil and waste water pipes conforming to Type B including
jointing with seal ring. (i) Double socketed pipes.
2 Providing & fixing UPVC Floor trap of self cleansing design with CP Jali
NSR complete in all respects.
P-Trap type Floor Trap 110 x 90 mm Nos. 20.00 270.09 5,401.77
3 NSR Providing and fixing terminal guard.
4 Providing and fixing on wall face unplasticised - PVC moulded
fittings/accessories for unplasticised Rigid PVC pipes including jointing
NSR with seal ring leaving 10 mm gap for thermal expansion.
Digitally signed by SANJAY
Single tee with door
5 Providing and fixing C.P. brass Two-way angle valve for EWC points &
for fixing Ablution Health Fauct of approved quality conforming to15
NSR mm nominal bore Each 10.00 1,270.22 12,702.22
6 NSR Providing and fixing clean out plug
7 Providing and fixing on wall face unplasticised-Rigid PVC pipes
conforming to IS: 13592 Type A including jointing with seal ring
NSR conforming to IS: 5382 leaving 10mm gap for thermal expansion.
160mm dia Under floor Metre 10.00 1,130.08 11,300.82
8 Providing and fixing pvc Inlet fitting with 2 inlets 80 mm size fabricated
from 110 mm dia PVC pipes(approx. length=150mm to 300mm) and
fixed to PVC trap with joint and set in cement concrete as per standard
NSR drawing complete. Each 20.00 750.00 15,000.00
TOTAL [IV] 91,009.26
TOTAL INTERNAL WATER SUPPLY & SANITATION WORKS [I+II+III+IV+V] 15,06,263.57
Digitally signed by SANJAY
Sl No DSR No Description of Item Unit Quantity DSR Rate Amount(Rs) Market Rate (Rs) Amount(Rs)
Demolishing brick work manually/ by mechanical means
including stacking of serviceable material and disposal of
unserviceable material within 50 metres lead as per direction of
Engineer-in-charge..
15.7.4 In cement mortar opening kitchen wall Cum 10.00 1,698.45 16,985.00
Dismantling doors, windows and clerestory windows (steel or
2 15.12 wood) shutter including chowkhats, architrave, holdfasts etc.
complete and stacking within 50 metres lead :
15.12.1 Of area 3 sq. metres and below No. 120.00 302.70 36,324.00
Dismantling old plaster or skirting raking out joints and cleaning
3 15.56 the surface for plaster including disposal of rubbish to the
dumping ground within 50 metres lead.
Outer plaster Sqm 980.00 45.05 44,149.00
inner plaster Sqm 100.00 45.05 4,505.00
Dismantling tile work in floors and roofs laid in cement mortar
including stacking material within 50 metres lead
4 15.23.1 15.23.1 For thickness of tiles 10 mm to 25 mm 760.00 60.50 45,980.00
Dismantling of cement concrete platform along with curtain
walls and base concrete etc. including stacking of useful
materials near the site and disposal of unserviceable materials
within 50 metres lead :
Removing dry or oil bound distemper, water proofing cement
paint and the like by scrapping, sand papering and preparing
the surface smooth including necessary repairs to scratches
for internal walls Sqm 940.80 20.85 19,616.00
for External ceiling Sqm 960.00 20.85 20,016.00
Dismantling C.I. pipes including excavation and refilling
trenches after taking out the pipes, manually/ by mechanical
7 15.45 means breaking lead caulked joints, melting of lead and
making into blocks including stacking of pipes & lead at site
within 50 metre lead as per direction of Engineer-in-charge:
Dismantling asbestos cement pressure pipes including
excavation and refilling trenches after taking out the pipes
manually/ by mechanical means and stacking the pipes within
50 metres lead as per direction of Engineer-in-charge :
Dismantling of flushing cistern of all types (C.I./PVC/Vitreous
9 15.52 China) including stacking of useful materials near the site and No. 24.00 744.60 17,870.00
disposal of unserviceable materials within 50 metres lead.
Digitally signed by SANJAY
Disposal of building rubbish / malba / similar unserviceable,
dismantled or waste materials by mechanical means, including
#REF! 15.60 loading, transporting, unloading to approved municipal Cum 200.00 219.35 43,870.00
dumping ground or as approved by Engineer-in-charge,
beyond 50 m initial lead, for all leads including all lifts involved.
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a
floating coat of neat cement.(External)
Extra for plastering exterior walls of height more than 10 m from
ground level for every additional height of 3 m or part thereof.
Repairs to plaster of thickness 12 mm to 20 mm in patches of
area 2.5 sq.meters and under, including cutting the patch in
proper shape, raking out joints and preparing and plastering
the surface of the walls complete, including disposal of rubbish
to the dumping ground, all complete as per direction of
Engineer-in-Charge
With cement mortar 1:4 (1cement: 4 coarse sand) with chiken
mesh/ fiber mesh
Extra for providing and mixing water proofing material in of 50kg
15 13.21 cement plaster work in proportion recommended by the cement 600.00 60 36,000.00
manufacturers. used in
Providing and laying vitrified floor tiles in different sizes
(thickness to be specified by the manufacturer) with water
absorption less than 0.08%and conforming to IS : 15622 , of
16 11.41 approved make, in all colours and shades, laid on 20mm thick
cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey
cement slurry @ 3.3kg/sqm including grouting the joints with
white cement and matching pigments etc., complete.
Providing and laying rectified Glazed Ceramic floor tiles of size
300x300 mm or more (thickness to be specified by the
manufacturer), of 1st quality conforming to IS : 15622, of
approved make, in all colours, shades, except White, Ivory,
Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4
(1 Cement : 4 Coarse sand), jointing with grey cement slurry @
3.3kg/sqm including pointing the joints with white cement and
matching pigments etc., complete.
18 13.6 20 mm cement plaster of mix : (for external walls)
19 15 mm cement plaster of mix: (for internal walls)
1:4 (1 cement: 4 coarse sand) Sqm 50.00 354.50 17,725.00
Digitally signed by SANJAY
Providing and laying water proofing treatment in sunken
portion of WCs, bathroom etc., by applying cement slurry
mixed with water proofing cement compound consisting of
applying : a) First layer of slurry of cement @ 0.488 kg /sqm
mixed with water proofing cement compound @ 0.253 kg/sqm.
20 22.5 layer will be allowed to air cure for 4 hours. b) Second layer of SQM 216 516.6 1,11,586.00
slurry of cement @ 0.242 kg/ sqm mixed with water proofing
cement compound @ 0.126 kg/ sqm. This layer will be allowed
to air cure for 4 hours followed with water curing for 48 hours.
The rate includes preparation of surface, treatment and sealing
of all joints, corners, junctions of pipes and masonry with
polymer mixed slurry.
FOAM CONCRETE FILLING UNDER TOILETS AND PANTRY:- Filling
and compacting Foam Concrete for raising level of toilets and
21 pantry and finishing in a coat of lean concrete screeding with CUM 64.8 5,525.00 358020
waterproofing compound complete in all respects to take Tile
Flooring as per flooring specifications.
TILE DADO :- Providing and fixing Ist quality ceramic glazed
wall tiles conforming to IS: 15622 (thickness to be specified by
the manufacturer), of approved make, in all colours, shades
except burgundy, bottle green, black of any size as approved
22 8.31 by Engineer-in-Charge, in skirting, risers of steps and dados, sqm 620 1063.45 6,59,339.00
over 12 mm thick bed of cement mortar 1:3 (1 cement : 3
coarse sand) and jointing with grey cement slurry @ 3.3kg per
sqm, including pointing in white cement mixed with pigment of
matching shade complete.
Providing and fixing 18 mm thick gang saw cut, mirror polished,
premoulded and prepolished, machine cut for kitchen
platforms, vanity counters, window sills, facias and similar
locations of required size, approved shade, colour and texture
23 8.2 laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 Sqm
coarse sand), joints treated with white cement, mixed with
matching pigment, epoxy touch ups, including rubbing, curing,
moulding and polishing to edges to give high gloss finish etc.
complete at all levels
8.2.2 Granite stone slab colour black, Cherry/Ruby red Sqm 96.00 4,425.35 4,24,834.00
Providing edge moulding to 18 mm thick marble stone
counters, Vanitiesetc., including machine polishing to edge to
give high gloss finish etc. complete as per design approved by
Engineer-in-Charge.
8.3.2 Granite work metre meter 96.00 418.85 40,210.00
Digitally signed by SANJAY
Providing and laying Polished Granite stone flooring in required
design and patterns, in linear as well as curvilinear portions of
the building all complete as per the architectural drawings
with 18 mm thick stone slab over 20 mm (average) thick base
25 11.56 of cement mortar 1:4 (1 cement : 4 coarse sand) laid and
jointed with cement slurry and pointing with white cement slurry
admixed with pigment of matching shade including rubbing,
curing and polishing etc. all complete as specified and as
directed by the Engineer-in-Charge
Polished Granite stone slab colour of Black, Cherry/Ruby
Red or equivalent
Three track three panels sliding window with fly proof SS wire
mesh (Two nos. glazed & one no. wire mesh panels) made of
26 9.147D.2 (small series) frame 92 x 44 mm & sash 32 x 60 mm both having Sqm 288.00 10,030.30 28,88,726.00
wall thickness of 1.9 ± 0.2 mm and single glazing bead of
appropriate dimension (Area of window upto 1.75 sqm).
Casement window single panel with S.S. friction hinges (300 x 19
x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x
27 9.147A.1 68 mm both having wall thickness of 1.9 ± 0.2 mm and single Sqm 120.00 10,443.75 12,53,250.00
glass pane glazing bead of appropriate dimension. (Area of
window upto 0.75 sqm.)
Providing and applying white cement based putty of average
thickness 1 mm, of approved brand and manufacturer, over
the plastered wall surface to prepare the surface even and
smooth complete.
Applying priming coats with primer of approved brand and
29 13.85 manufacture, having low VOC (Volatile Organic Compound )
With water thinnable cement primer on wall surface
having VOC content less than 50 grams/litre
Wall painting with premium acrylic emulsion paint of interior
grade, having VOC (Volatile Organic Compound ) content less
31 13.83 than 50 grams/ litre. of approved brand and manufacture,
including applying additional coats wherever required to
achieve even shade and colour.
Providing and applying white cement based putty of average
thickness 1 mm, of approved brand and manufacturer, over
the plastered wall surface to prepare the surface even and
smooth complete.
Finishing walls with Acrylic Smooth exterior paint of required
New work (Two or more coat applied @ 1.67 ltr/10 sqm
34 13.46.1 over and including priming coat of exterior primer applied Sqm 960.00 166.85 1,60,176.00
35 14.14.1 Red/ white sand stone slabs 30 to 50 mm thick. Sqm 50.40 1,099.15 55,397.00
Digitally signed by SANJAY
Providing and fixing stainless steel ( Grade 304) railing made of
Hollow tubes, channels, plates etc., including welding,
grinding, buffing, polishing and making curvature (wherever
required) and fitting the same with necessary stainless steel nuts
and bolts complete, i/c fixing the railing with necessary
36 10.28 accessories & stainless steel dash fasteners , stainless steel bolts Kg 3,375.00 612.25 20,66,344.00
etc., of required size, on the top of the floor or the side of waist
slab with suitable arrangement as per approval of Engineer-in
charge, (for payment purpose only weight of stainless steel
members shall be considered excluding fixing accessories such
as nuts, bolts, fasteners etc.).
Providing and laying in situ seven course water proofing
treatment with APP (Atactic Polypropylene) modified Polymeric
membrane over roof consisting of first coat of bitumen primer
@ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material
@ 1.20 kg/sqm, which shall consist of blown type bitumen of
14.88 grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing
membrane APP modified Polymeric membrane 2.0 mm thick of
3.00 Kg/sqm weight consisting of five layers prefabricated with
centre core as 100 micron HMHDPE film sandwiched on both
sides with polymeric mix and the polymeric mix is protected on
both side with 20 micron HMHDPE film.
7th, the top most layer shall be finished with brick tiles of class
designation 10 grouted with cement mortar 1:3 (1 cement : 3
fine sand) mixed with 2% integral water proofing compound by
weight of cement over a 12 mm layer of cement mortar 1:3 ( 1
cement : 3 fine sand) and finished neat (item of laying brick
tiles shall be paid for separately).
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate) finished with a floating coat of neat
cement, including cement slurry, but excluding the cost of
nosing of steps etc. complete.
11.3.1 40 mm thick with 20 mm nominal size stone aggregate sqm 260.00 545.00 1,41,700.00
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300
mm x 20 mm) with SRI (solar refractive index) > 78, solar
reflection > 0.70 and initial emittance > 0.75 on waterproof and
sloped surface of terrace, laid on 20 mm thick cement sand
39 12.55 mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and Sqm 250.00 1,444.90 3,61,225.00
grouting the joints with mix of white cement & marble powder
in ratio of 1:1, including rubbing and polishing of the surface
upto 3 cuts complete, including providing skirting upto 150 mm
height along the parapet walls in the same manner.
Digitally signed by SANJAY
Providing and fixing double scaffolding system (cup lock type)
on the exterior side of building/structure, upto 25 metre height,
above ground level, including additional rows of scaffolding in
stepped manner as per requirement of site, made with 40mm
dia M.S. tube, placed 1.5 metre centre to centre, horizontal &
40 24.2 vertical tubes joint with cup & lock system with M.S. Tubes, M.S.
tube challis, M.S. clamps and staircase system in the
scaffolding for working platform etc. and maintaining it in a
serviceable condition for execution of work of cleaning and/
or pointing and/ or applying chemical and removing it
The scaffolding system shall be stiffened with bracings, runners,
connecting with the building etc, wherever required, if feasible,
for inspection of work at required locations with essential safety
features for the workmen etc., complete as per directions and
approval of Engineer-in-charge.
Note :- (1) The elevational area of the scaffolding shall be
measured for payment purpose.
(2) The payment will be made once only for execution of all
items for such works.
Size of Tile 800x800 mm
Providing 10 mm thick plaster of Paris (gypsum anhydrous)
ceiling up to a height of 5 m above floor level, over first class
41 12.31 kail wood strips 25x6 mm with 10 mm gap in between and
reinforced with rabbit wire mesh fixed to wooden frame (frame
work to be paid separately):
Extra for sunk or raised mouldings in the plaster of Paris
(Gypsum anhydrous) ceiling.
Providing wood work in frames of doors, windows, clerestory
windows and other frames, wrought framed and fixed in
43 position with hold fast lugs or with dash fasteners of required cum 4.00 1,31,576.95 5,26,308.00
dia & length (hold fast lugs or dash fastener shall be paid for
separately). Second class teak wood
Providing and fixing ISI marked flush door shutters conforming
to IS : 2202 (Part I) decorative type, core of block board
construction with frame of 1st class hard wood and well
44 9.20.1 matched teak three ply veneering with vertical grains or cross Sqm 56.00 3,086.10 1,72,822.00
bands and face veneers on both faces of shutters. 35 mm thick
Fixing with hinges of required size and necessary screws (Note:
Hinges and necessary screws hall be paid separately
SITC Stainless steel SS-304 kitchen sink - with drain board 510 x
1040 mm bowl depth 270 mm (min)
Providing and fixing bright /matt finished Stainless Steel handles
of approved quality & make with necessary screws etc all
Digitally signed by SANJAY
Providing and fixing bright finished brass 100 mm mortice latch
with one dead bolt and a pair of lever handles of approved
quality with necessary screws etc. complete.
Providing and fixing modular kitchen units for the kitchen
platform and top wall units to be fabricated by using HDHMR
48 MR board of thickness 18 mm for making cabinets of required sizes
to match with the sizes SS kitchen jali units and size of the SS sink
as per following details:-
Front , bottom , top , sides and shelf partitions of the modular
cabinets shall be of 18 mm thick HDHMR boards of M/s Green
panel Industries or approved equivalent and back portion shall
be of 8 mm thick HDHMR board or approved equivalent with
necessary fittings , screws , pasting materials, finishing all
exposed cut surfaces with self adhesive PVC tape in matching
shade as that of laminate . The shutters and the pull out units
shall be fixed 50 mm above the kitchen floor level . All the inner
portions of the cabinets shall be finished with 0.8 mm thick
laminate of white colour and approve make .. The front face of
the cabinet shall be finished with1 .0 mm ultra gloss laminate
shade 21162 MR+ & 21069 MR+ Merino make The fittings like
handles , telescopic channels , SS baskets , auto closing hinges
shall be paid separately under respective items below. Quoted
rates shall be inclusive of labour , materials , wastage ,
scaffolding , fixing arrangements of top and bottom units with
necessary dash fasteners , repairing the damages, shifting the
debris out of colony , CP , taxes etc all as required for the
execution of the work . Note :-Only front elevation area shall
be measured for payment purpose,
Top wall units of depth 300 mm approx. with shelves Sqm 40.00 18,000.00 7,20,000.00
Providing and fixing stainless steel baskets and other fittings,
50 MR accessories of modular kitchen of M/s Hettich or approved each 96.00 3,000.00 2,88,000.00
equivalent make as per below mentioned details :-
Supply and instalation of heavy duty SS 304 external grade
Cloth Hanger/Dryer for Balony, celing mounted with with UV
Protected Nylon Rope and Individual Drop Down Railer syetem
upto 12ft length
Complete Electrical works including Dismantling of internal
52 MR wiring, switch boards change of internal Wiring along with 8.00 5,310.00 42,480.00
Switchboards, fans lights and etc
Dismantling of Water Tank over the roof with proper disposal of
Digitally signed by SANJAY
Providing and placing on terrace (at all floor levels)
polyethylene water storage tank, IS : 12701 marked, with cover
54 18.48 and suitable locking arrangement and making necessary holes per litre 20,000.00 9.70 1,94,000.00
for inlet, outlet and overflow pipes but without fittings and the
base support for tank.
Complete dismantling of lifts along with disposal of old
machine parts as per Engineer incharge
TV Cabinet Unit- in 18 mm HDHMR ply of size 1500mm x 1200
mm having setup box holder, size 1200 mm x 200 mm placed
100 mm from bottom of TV unit. All side with 2mm laminate of
approved colour and provision of 6/16 Amp socket at top, TV
cable with switch plate. Two numbers of n6/16 Amp socket with
control switch above set up box
Low side Airconditioning works including chasing, Copper
piping, insulation of copper pipe, and repairing of chased area
with cement and mortar wherever required to match existing
plastered surface. Specified brand for insulation Superlon with
wall thickness of minimum 13mm. SPecified brand for copper
piping. Only One (1) length between indoor and outdoor unit
shall be measured for payment.
Low side Airconditioning works including chasing, laying of
drain pipe, sealing of all joints, and repairing of chased area
#REF! MR with cement and mortar wherever required. For drain piping rmt 600.00 391.00 2,34,600.00
Supreme UPVC pipes of 10KGF to be used. Of 25mm Diameter.
Interconnecting cable for AC units between indoor & Outdoor
#REF! MR SITC Of chimney for kitchen. nos. 8.00 12,000.00 95,999.97
#REF! MR SITC of wardrobe as per design and detail. nos. 24.00 80,000.00 19,20,000.00
#REF! MR SITC of 20L gyeser nos. 24.00 12,000.00 2,87,999.91
#REF! MR SITC of 3L gyeser nos. 8.00 5,000.23 40,001.83
SITC of Inetrior Items Like, Pelmets,Curtain rods, Door Closeer,
CEILING PELMETS :- Providing and fixed pelmet of overall size
150mmx150mm and made hardwood framings hung from
ceiling @1000mm centre to centre with 2 nos of 6mm thk.
Commercial ply on vertical & 12mm thk. Commercial ply on
horizontal surface (straight & curved). Inclusive of finishing in
#REF! MR SITC of concealed door closer Nos. 8.00 6,241.99 49,935.91
#REF! MR SITC of Curtain Rod m 8.00 643.30 5,146.41
SITC of SS-304 Steel Safety Main door, with inetrnal SS-304
Mosquito Mesh, with heavy duty interlock
1 SOLAR PANELS
Digitally signed by SANJAY
Schedule of Supply, Installation, Testing and Commissioning of on grid Solar
Rates & Delhi Photovoltaic Power Plant conforming to MNRE specifications as
Analysis of amended, consisting of Mono/ Poly Crystalline silicon solar
Rates (E&M) cells, net metering facility, necessary protections, earthing,
(Item for Solar mounted on Aluminium/ GI structure of suitable strength with
Photovoltaic following components complete as required:-
a)Solar Photo voltaic Module of capacity 330W por above,
manufactured in India, conforming to IS 14286/ IEC61215, IS/
IEC61730 - Part - 1, IS/IEC61730 - Part - 2. Solar Photo voltaic
Module conversion efficiency shall not be less than 16.5%. PV
modules used in solar power plants / systems must be
warranted for their output peak watt capacity ,which should
not be less than 90% at the end of 10 years and 80% at the end
b)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage
range and 400 V AC, three phase, 4 wire, 50 Hz+/- 2.5Hz, output
voltage suitable to generate AC Power with efficiency not less
than 97%, total harmonic distortion less than 3% and suitable for
ambient temperature from 0 to 50 degree C. The PCU shall
adjust the voltage and frequency level to suit the Grid Voltage
c) Data Monitoring System complete with accessories.
d) Fixing of Array junction box & Main junction box with IP65
protection and termination arrangement for incoming and out
going cable along with glands, lugs and other accessories etc.
e) Lightning and surge voltage protection.
f) Connections & Interconnections by supplying & fixing
required size XLPE insulated copper conductor 1.1kV grade
armoured power and control cables between solar modules,
main power cable to grid supply PCU unit along with supplying
& fixing of necessary channel/ conduit lugs and other
accessories etc. as required.
Sub Head 1 : WIRING IN STEEL AND PVC CONDUIT
Digitally signed by SANJAY
Wiring for light point/ fan point/ exhaust fan point/ call bell
point with 1.5 sq.mm FRLS PVC insulated copper conductor
single core cable in surface / recessed medium PVC conduit
modular switch, modular plate, suitable GI box and earthing
point with 1.5 sq.mm FRLS PVC insulated copper conductor
single core cable etc. as required.
Wiring for group controlled (looped) light point/fan
point/exhaust fan point/ call bell point (without independent
switch etc.) with 1.5 sq. mm FRLS PVC insulated copper
2 1.55 conductor single core cable in surface/ recessed medium PVC
conduit conduit, and earthing the point with 1.5 sq. mm FRLS
PVC insulated copper conductor single core cable etc. as
Wiring for twin control light point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface /
recessed medium PVC conduit conduit, 2 way modular switch,
suitable GI box and earthing the point with 1.5 sq.mm FRLS
PVC insulated copper conductor single core cable etc. as
Wiring for circuit/ submain wiring alongwith earth wire with the
following sizes of FRLS PVC insulated copper conductor, single
core cable in surface/ recessed medium PVC conduit conduit
Supplying and drawing following pair 0.5 mm dia FRLS PVC
insulated annealed copper conductor, unarmored telephone
cable in the existing surface/ recessed steel/ PVC conduit as
Digitally signed by SANJAY
Supplying and drawing co-axial TV cable, 0.7 mm
solid copper conductor PE insulated, shielded with fine tinned
copper braid and protected with PVC sheath in the existing
surface/ recessed steel/ PVC conduit as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the
existing surface/ recessed Steel/ PVC conduit as required.
Supplying and fixing of following sizes of medium class PVC
conduit along with accessories in surface/recess including
8 1.21 cutting the wall and making good the same in case of
conduit as required.
Supplying and drawing following pair 0.5 mm dia FRLS PVC
9 insulated annealed copper conductor, armored telephone
cable as required similar to Skytone or equivalent.
Supplying and fixing two module stepped type electronic fan
10 1.25 regulator on the existing modular plate switch box including 48.0 Each 369.00 17,712.00 0.00
connections but excluding modular plate etc. as required.
Supplying and fixing following modular switch/ socket on the
11 1.24 existing modular plate & switch box including connections but
excluding modular plate etc. as required.
c 1.24.6 Telephone socket outlet 32.0 Each 148.00 4,736.00 0.00
d 1.24.7 TV antenna socket outlet 32.0 Each 148.00 4,736.00 0.00
RJ 45 Socket For Internet Similar to Legrand Cat Ref. 673155 or
Supplying and fixing following size/ modules, GI box alongwith
12 1.27 modular base & cover plate for modular switches in recess etc.
Digitally signed by SANJAY
Supplying and fixing suitable size GI box with modular plate
and cover in front on surface or in recess, including providing
and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular
switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate
and cover in front on surface or in recess, including providing
and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and
15/16 A modular switch, connections etc. as required.
Supplying & fixing suitable size GI box wih modular plate and
cover in front on surface or in recess including providing and
fixing 25 A modular socket outlet and 25 A modular SP MCB,
“C” curve including connections, painting etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase,
230 V, complete as required.
Installation, testing and commissioning of ceiling fan, including
wiring the down rods of standard length (upto 30 cm) with 1.5
sq. mm FRLS PVC insulated, copper conductor, single core
cable etc. as required.
Installation of exhaust fan in the existing opening, including
19 1.50 making good the damage, connection, testing,commissioning
etc. as required.
Extra for fixing the louvers/ shutters complete with frame for a
exhaust fan of all sizes.
Supply, installation, testing & commissioning of following size
22 Telephone KG Krone Box with hing door and mounting
accessories as required.
Supply Installation testing and commissioning of Pach panel for
23 internet of following port with all additional accessories as
Supply Installation Testing & Commissioning of 2U Wall
Mountable powder coted Rack with 3x5A Power Manager, 1
position fan, min 2 nos of shelf, Front Glass door with Lock & key
at respective floor.
Digitally signed by SANJAY
Supply, installation, testing & commissioning of TV Splitter Box.
Sub Head 2 : DBs & MCBs
Supplying and fixing following way, single pole and neutral,
sheet steel, MCB distribution board, 240 V, on surface/ recess,
1 2.3 complete with tinned copper bus bar, neutral bus bar, earth
bar, din bar, interconnections, powder painted including
earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing of following ways surface/ recess
mounting, vertical type, 415 V, TPN MCB distribution board of
sheet steel, dust protected, duly powder painted, inclusive of
2 2.5 200 A tinned copper bus bar, common neutral link, earth bar,
din bar for mounting MCBs (but without MCBs and incomer ) as
required . (Note : Vertical type MCB TPDB is normally used
where 3 phase outlets are required.)
Supplying and fixing following rating, four pole, 415 V, isolator
3 in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
Supplying and fixing 240/415 V, 10 kA, “C” curve, miniature
circuit breaker suitable for inductive load of following poles in
the existing MCB DB complete with connections, testing and
commissioning etc. as required.
Providing and fixing M.V. danger notice plate of 200 mm X 150
mm, made of mild steel, at least 2 mm thick, and vitreous
enameled white on both sides, and with inscription in single red
colour on front side as required.
Sub Head 3 : Surface/Recess Luminaire
Supplying installation testing and commissioning Recess Mount
1 MR (RA-6) Downlighter Mollis Recess Downlighter 15W LED complete in all 200.0 Each 2,134.00 4,26,800.00
Digitally signed by SANJAY
4 MR (RA-9) Supplying of 1200mm sweep ceiling fan 48.0 Each 3,214.63 1,54,302.03
Supplying installation testing and commissioning of 450mm
sweep 1500 RPM heavy Duty Exhaust Fan .
Supplying installation testing and commissioning of 20W LED
Sub Head 1 : Earthing
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick
including accessories, and providing masonry enclosure with
cover plate having locking arrangement and watering pipe of
2.7 meter long etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia
2 5.2 including accessories, and providing masonry enclosure with 16.0 Each 6,855.00 1,09,680.00 0.00
cover plate having locking arrangement and watering pipe
etc. with charcoal/coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter
below ground as strip earth electrode, including connection/
3 5.9 terminating with G.I. nut, bolt, spring, washer etc. as required. 30.0 Meter 144.00 4,320.00 0.00
(Jointing shall be done by overlapping and with 2 sets of G.I.
nut bolt & spring washer spaced at 50 mm)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I.
4 5.11 pipe from earth electrode including connection with G.I. nut, 500.0 Meter 706.00 3,53,000.00 0.00
bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in
recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in
9 5.15 recess for connections etc. as required. 210.0 Meter 244.00 51,240.00 0.00
Sub Head 2 : Panel, Cable & End Termination
BUILDING L.T PANEL
Digitally signed by SANJAY
The Main LT Panel shall use all draw out type breakers suitable
for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. The
panel shall have AMF facility to achieve electrical
interlocking, synchronizing, buscoupler switching, auto
operation of incommer and bus coupler, auto start of D.G.
Sets, auto D.G. running by pre set timing, auto changeover etc
and having following incomming and outgoing Air Circuit
Breakers, FSU's as per the drawing and
specification.interlocking, buscoupler switching, auto
operation of incommer and bus coupler, auto start of D.G.
Sets, auto D.G. running by pre set timing, auto changeover etc
and having following incomming and outgoing Air Circuit
Breakers, FSU's as per the drawing and specification.Each
incoming breaker will have microprocessor based releases and
all outgoing breaker will have minimum electrostatic releases
or mention as mention in BOQ. The Panel will be made as per
detailed specifications & drawings forming part of this
document. Fault level of panel shall be 35 MVA.
2 Nos. 160 Amp FP MCCB
1 Nos. 200 Amp TPN busbars of aluminium alloy as per SLD.
AUTO OPERATION OF INCOMER / BUSCOUPLER ACB's.
Load Management through PLC
Contactor for Load Management System
Buscoupler switching.
8 Nos. 63 Amp TP MCB
4 Nos. 40Amp DP MCB
2 sets of multifunction meter with parameter
current,voltage,KWH,KVAH,Power factor on incoming from
2 Sets of phase indicating lights (RYB) with protection fuses (one
set for each incoming breaker).
2 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each
incoming breaker).
2 Sets auto trip indicating lamp .
Note: All outgoings should have ammeter and RYB indications
with backup MCB as indicated in single line diagrams.
8 Nos. 3 Phase Energy Meter
UNDER GROUND CABLES
Digitally signed by SANJAY
Supply of 3.5core and 4 core 1.1 KV LT power cable with
solid/stranded compacted aluminium conductor, XLPE
insulated colour coaded, Laid up, PVC inner shethed armoured
7 with single layer of galvenized round wire or flat strip and over
all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and
Laying of one number PVC insulated and PVC sheathed / XLPE
8 7.3 power cable of 1.1 kV grade of following size direct in ground
including excavation and refilling the trench etc. as required,
but excluding sand cushioning and protective covering.
b 7.3.2 Above 35 sq. mm and upto 95 sq. mm 250.0 Meter 217.00 54,250.00 0.00
Laying of one number PVC insulated and PVC sheathed / XLPE
9 power cable of 1.1 kV grade of following size in the existing
RCC/ HUME/ METAL pipe as required.
b 7.5.2 Above 35 sq. mm and upto 95 sq. mm 100.0 Meter 57.00 5,700.00 0.00
Laying of one number PVC insulated and PVC sheathed / XLPE
10 7.6 power cable of 1.1 kV grade of following size in the existing
masonry open duct as required.
b 7.6.2 Above 35 sq. mm and upto 95 sq. mm 100.0 Meter 45.00 4,500.00 0.00
Laying and fixing of one number PVC insulated and PVC
11 7.8 sheathed / XLPE power cable of 1.1 kV grade of following size
on cable tray as required.
a 7.6.3 Upto 35 sq. mm (clamped with 1mm thick saddle) 170.0 Meter 63.00 10,710.00 0.00
Above 35 sq. mm and upto 95 sq. mm (clamped with 25 x 3mm
END TERMINATION
Supplying and making cable end terminations with brass
12 compression gland and aluminium lugs for folowing sizes of 3.5
Core and 4 Core PVC insulated PVC sheathed/XLPE aluminium
conductor cable of 1.1 KV grade, complete as required.
Unit Quantity DSR Rate Amount(Rs) Market Rate (Rs) Amount(Rs)
Digitally signed by SANJAY
1 Providing and fixing white glazed earthen wate (European
PWD SOR type) W.C. Pan 580mm dia,(10 ltr) C.I. Flushing Cistern complete
2022 with G.I. Pull chain,M.S.Bracket of Engineer-in-
SI.No.(4+8+6) Charge.(Standered size) each 24.00 3,850.00 92,400.00
2 Providing & fixing white vitreous china wash basin with C.I.
brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass
chain with rubber plug, 32mm C.P. brass waste of standerd
pattern including cutting & making good the walls wherever
17.70 required.
a)White Vitreous China Wash basin size 630x450 mm with a pair
17.7.1 of 15 mm C.P. brass pillar taps each 24.00 1,974.99 47,399.76
3 Providing and fixing white vitreous china flat back half stall
urinal of size 580*380*350mm with white PVC automatic flushing
cistern, with fittings, standard size C.P. brass flush pipe,
spreaders with unions and clamps (all in D.P. brass) with waste
fitting as per IS : 2556, C.I. trap with outlet grating and other
couplings in C.P. brass including painting of fittings and cutting
and making good the walls and floors wherever required:
Range of single half stall urinals with 5 litre PV.C. automatic
17.5.1 flushing cistern. each 0.00 8,792.65 0.00
4 Providing and fixing P.V.C. waste pipe for sink or wash basin
17.28 including P.V.C. waste fittings complete.
17.28.1 Semi rigid pipe
5 Providing and fixing 600x450mm bevelled edge mirror of
superior glass (of approved quality) complete with 6mm thick
hard board ground fixed to wooden cleats with C.P. brass
17.31 screws and washers complete. each 24.00 1,225.06 29,401.44
6 Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink
as per I.S. 13983 with C.I. brackets and stainless steel plug 40
mm including painting of fittings and brackets, cutting and
17.10 making good the walls wherever required :
17.10.1 Kitchen sink with drain board
7 Providing and fixing PTMT Bottle Trap for Wash basin and sink
Bottle trap 38 mm single piece moulded with height of 270 mm,
effective length of tail pipe 260 mm from the centre of the
waste coupling, 77 mm breadth with 25 mm minimum water
seal, weighing not less than 263 gms
Digitally signed by SANJAY
8 Providing and fixing PTMT towel rail complete with brackets
fixed to wooden cleats with CP brass screws with concealed
fittings arrangement of approved quality and colour.
600 mm long towel rail with total length of 645 mm, width 78
mm and effective height of 88 mm, weighing not less than 190
CP Brass fittings
9 Providing and fixing unplasticised PVC connection pipe with
18.21 brass unions
18.21.2 45 cm length
10 Providing and fixing C.P. brass bib cock of approved quality
18.49 conforming to IS:8931
11 Providing and fixing C.P. brass long body bib cock of approved
quality conforming to IS standards and weighing not less than
12 Providing and fixing C.P. brass angle valve for basin mixer and
gyser points of approved quality conforming to IS:8931
13 Providing and fixing C.P. brass shower rose with 15 or 20mm inlet
14 Providing and fixing C.P. brass stop cock (concealed) of
standard design and of approved make conforming to IS:8931:
II RAIN WATER SUPPLY
1 Providing and fixing unplasticised-PVC pipe clips of approved
design to unplasticised-PVC pipes by means of 50x50x50 mm
hard wood plugs, screwed with MS screws of required length
including cutting brick work and fixing in cement mortar 1:4 (1
cement : 4 coarse sand) and making good the wall etc.
12.43 complete.
2 Providing and laying cement concrete 1:5:10(1 cement : 5
coarse sand : 10 graded stone aggregate 20mm nominal size)
around P.V.C Soil and waste pipe including bed concrete as
DSR no.19.2.1 per standard design(embedded in the flooring / ground)
Digitally signed by SANJAY
3 Providing and fixing on wall face unplasticised-Rigid PVC rain
water pipes conforming to IS: 13592 Type A including jointing
with seal ring conforming to IS: 5382 leaving 10mm gap for
12.41 thermal expansion.
4 Providing and fixing on wall face unplasticised PVC moulded
fittings/accessories for unplasticised Rigid PVC rain water pipes
conforming to IS:13592 Type A including jointing with seal ring
conforming to IS:5382 leaving 10mm gap for thermal expansion.
12.42.5.2 Bend 87.5 degree
12.42.6 Shoe (Plain)
5 Providing and fixing to the inlet mouth of rain water pipe cast
iron grating 15 cm diameter and weighing not less than 440
6 Providing and fixing unplasticised-PVC pipe clips of approved
design to unplasticised-PVC rain water pipes by means of
50x50x50 mm hard wood plugs, screwed with MS screws of
required length including cutting brick work and fixing in
cement mortar 1:4 (1 cement : 4 coarse sand) and making
12.43 good the wall etc. complete.
7 Making khurras 45x45 cm with average minimum thickness of 5
cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate of 20 mm nominal size) over PVC
sheet 1m x 1 m x 400 micron, finished with 12 mm cement
plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat
cement,punning,rounding the edges and making and finishing
the outlet complete.
III INTERNAL WATER SUPPLY
1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)
pipes, having thermal stability for hot & cold water supply
including all CPVC plain & brass threaded fittings i/c fixing the
pipe with clamps at 1.00m spacing. This includes jointing of
pipes & fittings with one step CPVC solvent cement and the
cost of cutting chases and making good the same including
testiang of joints complete as per direction of Engineer in
Concealed work including cutting chases and making good
18.8.3 25mm dia nominal outer dia pipes Rm. 125.00 543.49 67,936.25
Digitally signed by SANJAY
18.9.6 50mm dia nominal outer dia pipes Rm. 15.00 704.78 10,571.70
2 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)
pipes, having thermal stability for hot & cold water supply,
including all CPVC plain & brass threaded fittings, including
fixing the pipe with clamps at 1.00 m spacing. This includes
jointing of pipes & fittings with one step CPVC solvent cement
and testing of joints complete as per direction of Engineer in
Internal work-Exposed on wall
18.7.2 20 mm nominal outer dia Pipes Metre 150.00 282.23 42,334.50
3 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)
pipes, having thermal stability for hot & cold water supply,
including all CPVC plain & brass threaded fittings, i/c fixing the
pipe with clamps at 1.00 m spacing. This includes jointing of
pipes & fittings with one step CPVC solvent cement and the
cost of cutting chases and making good the same including
testing of joints complete as per direction of Engineer in
Concealed work, including cutting chases and making good
18.8.2 20 mm nominal outer dia Pipes Metre 150.00 446.00 66,900.00
4 Providing and fixing gun metal gate valve with wheel of
18.17 approved quality.
18.17.1 25mm dia nominal bore Each 11.00 462.15 5,083.65
17.17.4 50mm dia nominal bore Each 6.00 762.43 4,574.58
5 18.16 Providing and fixing brass stop cock of approved quality.
6 Providing and placing on terrace (at all floor
levels)polyethylene water storage tank ISI : 12701 marked
indicating the BIS License No. with cover and suitable locking
arrangement and making necessary holes for inlet, outlet and
over flow pipes but without fitting and base support for
tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid
18.48 ISI license].
Capcity in Per Liters 6,000.00 8.42 50,520.00
TOTAL[III] 6,61,843.14
NON SCHEDULED ITEMS
IV SANITARY INSTALLATIONS & C.P FITTINGS
1 Providing and fixing in floor and wall face Ringfit UPVC
Conventional system for soil and waste water pipes conforming
to Type B including jointing with seal ring. (i) Double socketed
Digitally signed by SANJAY
2 Providing & fixing UPVC Floor trap of self cleansing design with
NSR CP Jali complete in all respects.
P-Trap type Floor Trap 110 x 90 mm Nos. 20.00 270.09 5,401.77
3 NSR Providing and fixing terminal guard.
4 Providing and fixing on wall face unplasticised - PVC moulded
fittings/accessories for unplasticised Rigid PVC pipes including
jointing with seal ring leaving 10 mm gap for thermal expansion.
Single tee with door
5 Providing and fixing C.P. brass Two-way angle valve for EWC
points & for fixing Ablution Health Fauct of approved quality
NSR conforming to15 mm nominal bore Each 10.00 1,270.00 12,700.00
6 NSR Providing and fixing clean out plug
7 Providing and fixing on wall face unplasticised-Rigid PVC pipes
conforming to IS: 13592 Type A including jointing with seal ring
conforming to IS: 5382 leaving 10mm gap for thermal
NSR expansion.
160mm dia Under floor Metre 10.00 1,130.08 11,300.82
8 Providing and fixing pvc Inlet fitting with 2 inlets 80 mm size
fabricated from 110 mm dia PVC pipes(approx. length=150mm
to 300mm) and fixed to PVC trap with joint and set in cement
concrete as per standard drawing complete.
TOTAL [IV] 91,014.43
TOTAL INTERNAL WATER SUPPLY & SANITATION WORKS [I+II+III+IV+V] 7,52,857.57
Digitally signed by SANJAY
Sr. No. Specifications Unit Quantity Rate Amount
A Design, manufacture, supply, installation, testing, commissioning,
1 Designation of Lifts Gearless Machine Room Lift
2 No. of Elevator 02
3 Type and Capacity 8 Passenger
4 Speed 1.0 m/s or more
6 Location of Machine Room Top of Shaft
7 Total Travel 21 mts (Approx)
8 Serving 07 Floors
9 No. of Stops 7
10 Wll Size 2000 mm (W) X 2034 mm (D)
11 Power Supply 415 V Three Phase 50 Cycles AC
12 Auxiliary Single Phase 220V 50 Cycles AC
13 Car Size 1600 mm (W) X 1500 mm (D)
14 Pit Depth 1600 mm
15 Head Room 6000 mm
16 CAR ENCLOSURE
Car Ceiling SS Hairline Finish or as approved
Car Panels SS Honeycomb Finish or as approved
Car Flooring PVC or as approved
Car Illumination LED
17 No. Of Entrance One location Front
Centre Opening Power Door in
18 Car Entrance Powder Coated
19 Door Safety Full Height Infra-red safety curtains
Centre Opening Power Door in
20 Landing Entrance Powder Coated
21 Clear Opening 1000mm (W) X 2000 (H)
22 Control Full Collective Simplex
KDS 90 Full Height COP- Surface
Mounted Buttons-White LED
KDS 90 LCI- Surface Mounted Buttons-
17 The lift to have following minimum specifications/ features and/or as
a OEM Motor / Machine
b 2 Hr Fire rated (min) landing doors (Approved and certified by an
c 24/7 Connected Services (IOT Services) / Elevator 24/7 Real time data
d L.W.D ( Load Weighing Device )
e Car Door Mechanical Lock as standard (Safety Feature).
f Daily Automatic Brake Testing (Safety Feature).
g Automatic Phase Reversal
h Automatic Rescue Device (Safety Feature)
i Direction & Position Indicator In Car
j Emergency Alarm
k 2 Phase Fireman Drive
l Hands Free Press & Speak Intercom
m Full height infra red safety curtains
p Signal Fixtures In Stainless Steel Finish
q Emergency Light With Rechargeable Battery
r Adjustable Guide Shoes
s Micro Movement LED Based Buttons.
t +10% to -10% Volt. Fluct. Withstand Capacity NOS 2 25,03,840.35 50,07,680.69
Sr. No. Specifications Unit Quantity Rate Amount
A Design, manufacture, supply, installation, testing, commissioning,
1 Designation of Lifts Gearless Machine Room Lift
2 No. of Elevator 01
3 Type and Capacity 8 Passenger
4 Speed 1.0 m/s or more
6 Location of Machine Room Top of Shaft
7 Total Travel 12 mts (Approx)
8 Serving 03 Floors
9 No. of Stops 3
10 Wll Size 2000 mm (W) X 2034 mm (D)
11 Power Supply 415 V Three Phase 50 Cycles AC
12 Auxiliary Single Phase 220V 50 Cycles AC
13 Car Size 1600 mm (W) X 1500 mm (D)
14 Pit Depth 1600 mm
15 Head Room 6000 mm
16 CAR ENCLOSURE
Car Ceiling SS Hairline Finish or as approved
Car Panels SS Honeycomb Finish or as approved
Car Flooring PVC or as approved
Car Illumination LED
17 No. Of Entrance One location Front
Centre Opening Power Door in
18 Car Entrance Powder Coated
19 Door Safety Full Height Infra-red safety curtains
Centre Opening Power Door in
20 Landing Entrance Powder Coated
21 Clear Opening 1000mm (W) X 2000 (H)
22 Control Full Collective Simplex
KDS 90 Full Height COP- Surface
Mounted Buttons-White LED
KDS 90 LCI- Surface Mounted Buttons-
17 The lift to have following minimum specifications/ features and/or as
a OEM Motor / Machine
b 2 Hr Fire rated (min) landing doors (Approved and certified by an
c 24/7 Connected Services (IOT Services) / Elevator 24/7 Real time data
d L.W.D ( Load Weighing Device )
e Car Door Mechanical Lock as standard (Safety Feature).
f Daily Automatic Brake Testing (Safety Feature).
g Automatic Phase Reversal
h Automatic Rescue Device (Safety Feature)
i Direction & Position Indicator In Car
j Emergency Alarm
k 2 Phase Fireman Drive
l Hands Free Press & Speak Intercom
m Full height infra red safety curtains
p Signal Fixtures In Stainless Steel Finish
q Emergency Light With Rechargeable Battery
r Adjustable Guide Shoes
s Micro Movement LED Based Buttons.
t +10% to -10% Volt. Fluct. Withstand Capacity NOS 1 28,16,820.39 28,16,820.39
S. No. DSR Code Description Unit Qty DSR Rate Amount Market Rate Amount
Surface dressing of the ground including removing vegetation and
1 2.28 inequalities not exceeding 15 cm deep and disposal of rubbish, lead
up to 50 m and lift up to 1.5 m.
2.28.1 All kinds of soil SQM 112.5 28.15 3,166.88
Earth work in excavation by mechanical means (Hydraulic
excavator)/manual means over areas (exceeding 30 cm in depth,
2 2.6.1 1.5 m in width as well as 10 sqm on plan) including getting out and Cum 187.5 205.45 38,521.88
disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as
directed by Engineer-in-charge.- All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth,
sides of foundations etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead
up to 50 m and lift upto 1.5 m.
Disposal of surplus earth by mechanical transport including loading,
unloading for a lead upto 10 Km.
Providing and laying in position cement concrete of specified grade
4.1 excluding the cost of centering and shuttering - All work up to plinth
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone
aggregate 40 mm nominal size)
Providing and laying in position ready mixed or site batched design
mixcement concrete for reinforced cement concrete work; using
coarseaggregate and fine aggregate derived from natural sources,
PortlandPozzolana / Ordinary Portland /Portland Slag cement,
admixtures inrecommended proportions as per IS: 9103 to
accelerate / retard settingof concrete, to improve durability and
workability without impairingstrength; including pumping of
concrete to site of laying, curing, carriagefor all leads; but
excluding the cost of centering, shuttering, finishingand
reinforcement as per direction of the engineer-in-charge; for
thefollowing grades of concrete.
Note : Extra cement up to 10% of the minimum specified cement
contentin design mix shall be payable separately. In case the
cement contentin design mix is more than 110% of the specified
minimum cementcontent, the contractor shall have discretion to
either re-design the mixor bear the cost of extra cement
5.33.1 All works upto plinth level
Concrete of M25 grade with minimum cementcontent of 330 kg
Steel reinforcement for R.C.C. work including straightening, cutting,
5 5.22 bending, placing in position and binding all complete upto plinth
5.22.6 Thermo-Mechanically Treated bars KG 20439.10125 89.65 18,32,365.43
Centering and shuttering including strutting, propping etc. and
removal of form for :
a 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete SQM 134.45 307.95 41,403.88
Walls (any thickness) including attached pilasters, butteresses, plinth
and string courses etc.
Providing and fixing 1st quality ceramic glazed floor tiles conforming
to IS : 15622 (thickness to be specified by the manufacturer ) of
approved make in all colours, shades except burgundy, bottle
green, black of any size as approved by Engineer-in-Charge in
skirting, risers of steps and dados over 12 mm thick bed of cement
Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement
slurry @ 3.3kg per sqm including pointing in white cement mixed with
pigment of matching shade complete.
Providing and mixing integral crystalline admixture for water
proofing treatment to RCC structures like basement raft, retaining
walls, reservior, sewage & water treatment plant, tunnels / subway
and bridge deck etc. at the time of transporting of concrete into
the drum of the ready-mix truck, using integral crystalline admixture
@ 0.80% (minimum) to the weight of cement content per cubic
meter of concrete) or higher as recommended by the
manufacturer’s specification in reinforced cement concrete at site
of work. The material shall meet the requirements as specified in ACI-
212-3R- 2010 i.e. by reducing permeability of concrete by more than
90%, compared with control concrete as per DIN 1048 and resistant
to 16 bar hydrostatic pressure. The crystalline admixture shall be
capable of self-healing of cracks up to a width of 0.50mm. The work
shall be carried out all complete as per specification and the
direction of the Engineer-in-charge. The product performance shall
carry guarantee for 10 years against any leakage.
Supplying, installation, testing and commissioning of Electric driven
1 1 Main Fire Pump suitable for automatic operation and consisting of
following, complete in all respects, as required:
(a) Horizontal type, multistage, centrifugal, split casing pump of cast
iron body & bronze impeller with stainless steel shaft, mechanical
seal conforming to IS 1520.
(b) Suitable HP Squirrel cage induction motor, TEFC, synchronous
speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz,
AC supply with IP 55 protection for enclosure, horizontal foot
mounted type with Class-'F' insulation, conforming to IS-325.
(c) M.S. fabricated Common base plate, coupling, coupling guard,
foundation bolts etc. as required.
(d) Suitable cement concrete foundation duly plastered with anti
vibration pads.
Supplying, installation, testing and commissioning of diesel engine
driven main fire pump suitable for automatic operation and
consisting of following, complete in all respects, as required : (Diesel
Horizontal type, multistage, centrifugal pump of cast of iron body
and bronze impeller with stainless steel shaft, mechanical seal
conforming to IS 1520.
Suitable HP, 1500 RPM water cooled with radiator, diesel engine
conforming to relevant IS standard complete with auto starting
mechanism, 12 /24 volts electric starting equipment, diesel tank,
exhaust pipe extended upto 10 m outside pump house duly
insulated with 50 mm thick glass wool with 1.0 mm thick aluminium
sheet cladding, residential silencer, instruments and protection as
per standard specification, stop solenoid for auto stop in the event
of fault with audio indications, painted with post office red colour
etc. as required.
M.S fabricated, common base plate, coupling, coupling guard,
foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti
vibration pads.
Supplying, installation, testing and commissioning of electric driven
3 3 pressurisation pump suitable for automatic operation and consisting
of following, complete in all respects, as required : (Jockey Pump)
Horizontal type, multistage, centrifugal pump of cast iron body and
bronze impeller with stainless steel shaft, mechanical seal
conforming to IS : 1520.
Suitable HP squirell cage induction motor TEFC type suitable for
operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of
protection for enclosure, horizontal foot mounted type with Class-'F'
insulation, conforming to IS : 325.
M.S.fabricated Common base plate, coupling, coupling guard,
foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti
vibration pads.
Fabrication, supply, Insallation testing & commissioning of Electrical
control panel of cubical construction, floor mounted type,
fabricated out of 2mm thick CRCA sheet, compartmentalised with
hinged lockable doors, dust and vermin proof, powder coated of
approved shade after 7 tank treatment process, cable alley,
interconnection with suitable size copper conductor cable/solid
copper strip, having switchgears and accessories, mountings and
internal wiring, earth terminals, numbering etc. complete in all
respect, suitable for main fire pump, pressurisation pump & diesel
pump set complete as per CPWD specification with following in
coming and Outgoings, suitable for operation on 415V, 3 phase,
50Hz Ac Supply with enclosure protection class IP 42 as required :
4.1 5.1 Incomings
250A, 50kA 4 Pole MCCB, Ics=100% Icu rating
Digital Voltmeter 0-500V with selector switch
Digital Ammeter (0-250 A) with selector swtich & CTs
LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps
Set of Copper Bus Bar 300A
( Note : All outgoing feeders for pumps should have digital Ammeter
with selector switches, and LED type ON, OFF, trip indicating lamps)
125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta
starter suitable for 60 HP pump with overload protection, current
sensing type single phase preventor complete with all acceessories
and internal wiring required for automatic operation, selector switch
for local/remote, auto/manual/OFF operation.
63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic
Star/Delta starter with overload protection, current sensing type
single phase preventor complete with all acceessories and internal
wiring required for automatic operation, selector switch for
local/remote, auto/manual/OFF operation.
Diesel Engine Control
Control for diesel engine comprising -
Automatic/Manual selctor switch & 3 attempt starting device, timers
and relays as required, push buttons, start/stop in manual mode
Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp
and Engine on indication
Battery charger suitbale for 12V/24 V DC with boost and trickle
selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter
All standard relays and accessories for automatic operation of
System Controller
Designing, Supply, Installation, Testing and commissioning of system
controller to control operation of main electric fire pump, diesel
pump, Pressurization pump, Terrace pump in sequence as per
specification consisting of relays, timers. Sensors, annunciation
window for fault indication, complete as per specification
Providing laying, testing & commissioning of 'C' class heavy duty MS
Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges,
tapers, nuts bolts, gaskets etc. in ground including welding,
excavation & providing cement concrete blocks as supports,
anticorrosive treatment with coaltar/asphalt tape as per IS 10221,
refilling the trench etc. of following sizes complete as required.
Supplying and fixing Single headed external yard hydrant valve with
1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling
and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with
blank Gunmetal/Stainless Steel cap and chain as required :
6.1 10.1 Single headed Gunmetal Set 7.00 7,646.00 53,522.00
Supplying, fixing, testing and commissioning of butterfly valve of PN
1.6 rating with bronze/gunmetal seat duly ISI marked complete with
nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes
Supplying, fixing, testing & commissioning of double flanged sluice
valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat,
ISI marked complete with nuts, bolts, washers, gaskets and
conforming to IS 780 of following sizes as required :
Supplying and fixing orifice plate made out of 6 mm thick stainless
steel (Grade 304) with orifice of required size to be fitted between
9 13 flange & landing valve of external and internal hydrants to reduce Each 0.00 0.00
pressure at the outlet to the level of 3.5 kg/cm2 complete as
Providing, installation, testing and commissioning of non-return valve
10 14 of following sizes confirming to IS: 5312 complete with rubber gasket,
GI bolts, nuts, washers etc.as required :
Providing, installation, testing and commissioning of stainless steel Y-
11 15 strainer fabricated out of 1.6 mm thick stainless steel, Grade 304,
sheet with 3 mm dia holes with stainless steel flange.
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm
12 16 dia male and female couplings duly bound with GI wire, rivets etc.
conforming to IS 636 (type-A) as required :
Supplying and fixing first-aid Hose Reel with MS construction spray
13 17 painted in post office red, conforming to IS 884 complete with the
following as required.
20 mm nominal internal dia water hose thermoplastic (Textile
reinforced) type -2 as per IS: 12585
20 mm nominal internal dia gun metal globe valve & nozzle.
Drum and brackets for fixing the equipmets on wall. Connections
from riser with 25 mm dia stop gun metal valve & M.S. Pipe and
Supplying & fixing 63 mm dia gun metal short branch pipe with 20
mm nominal internal diameter size nozzle conforming to IS 903
suitable for instantaneous connection to interconnect hose pipe
coupling as required :
Supplying and fixing of fire brigade connection of cast iron body
with gun metal male instantaneous inlet couplings complete with
cap and chain as reqd. for suitable dia MS pipe connection
conforming to IS 904 as required :
Providing and fixing ISI Marked of approved make Fire Extinguishers
complete with all accessories as per manufacturer's specifications.
MR CO2 gas nozzle type - 6.5 Litre capacity (IS:15683). Nos 40.00 9,153.00 3,66,120.00 0.00
BOQ OF MATERIALS FOR CCTV INSTALLATION
S No. Item Type Complete Technical Specification UNIT QTY RATE AMOUNT
Bullet CCTV OUTDOOR IP IR 4MP,
1/2.8" progressive scan CMOS
High quality imaging with 4 MP resolution
Excellent low-light performance with powered-by-DarkFighter technology
Audio visual alarm: The white flashing light and audible warning can be
triggered by certain events
25× optical zoom and 16× digital zoom provide close up views over
expansive areas
Expansive night view with up to 200 m IR distance
Focuses on human and vehicle targets classification based on deep
Face capture: Up to 5 faces captured at the same time
Up to 40-ch IP camera inputs
H.265+/H.265/H.264+/H.264 video formats
Up to 2-ch@8 MP or 4-ch@4 MP or 8-ch@1080p decoding capacity
2 NVR-8Ch 1 HDMI and 1 VGA interfaces: both interfaces support independent video NO 1.00 1,28,443.91 128443.9114
2 SATA interfaces for HDD connection (up to 10 TB capacity per HDD)
Up to 80 Mbps incoming bandwidth
Plug-and-play with 8 power over Ethernet (PoE) interfaces
2TB WD Purple Surveillance Internal Hard Drive HDD - SATA 6 Gb/s, 256 MB
6CORE OFC CABLE ARMOURED OS2
No. of Cores- 6 Core
Cable Type-Armoured
Cable Length-2Km
Mode Type-Single Mode
Jacket Material-LSZH
Operating Temperature--40 deg C to +70 deg C
Storage Temperature--40 deg C to +60 deg C
Bend Radius-Short term : 20D,Long Term : 10D
Jacket Thickness-1.8 +- 0.2 mm
5 Power Cable CABLE,CU,3CX1.5SQMM,ARMOURED,1.1KV,XLPE M 750.00 194.55 145910.2186
Media Converter FO/Ethernet
Standards and ProtocolsIEEE 802.3i, IEEE 802.3u
Basic FunctionAdopts WDM technology
Half/Full-Duplex transfer mode for FX port
Extends fiber distance up to 20km
Ports1 100M SC/UPC port
1 10/100M RJ45 port (Auto MDI/MDIX)
Wave Length1310nm Tx/1550nm Rx
Network Media 10BASE-TUTP category 3, 4, 5 cable (maximum 100m)
EIA/TIA-568 100Ω STP (maximum 100m)
Network Media 100BASE-TUTP category 5, 5e cable (maximum 100m)
6 Media Converter EIA/TIA-568 100Ω STP (maximum 100m) NO 2.00 5,310.32 10620.63549
Network Media 100BASE-FXSingle-mode Fiber
LED IndicatorsPWR, Link/Act
Dimensions (W*D*H)3.7*2.9*1.1 in. (94.5*73.0*27.0 mm)
Power SupplyExternal Power Adapter
Max Power Consumption2.41W
Safety & Emission FCC, CE, RoHS
Package Contents• Media Converter MC112CS
• Power Adapter
• Installation Guide
Environment Operating Temperature: 0℃~40℃ (32℉~104℉)
Storage Temperature: -40℃~70℃ (-40℉~158℉)
Operating Humidity: 10%~90% non-condensing
Storage Humidity: 5%~90% non-condensing
Digitally signed by SANJAY
8-Port Gigabit VPN Router
7 Router Port Configurable:1 port configurable (LAN/WAN) NO 2.00 20,060.60 40121.20387
Connectivity Technology: rj-45, USB
Number of Ports:8
8 Ethernet Switch NO 2.00 21,240.00 42480
Connector Type:Ethernet
LIU 6 PORT Rack Mount - Loaded
PATCH CORD SINGLE MODE DUPLEX 3M SC,
PIGTAIL SINGLE MODE (SC)
TERMINATION BOX 2WAY MODEL (Economy)
14 OutDoor N/W Rack IP 66 Outdoor Wall Rack 6U X 550mm W X 500 mm with PDU & FAN, IP66 NO 3.00 7,500.09 22500.26589
TOTAL 754425.06
Digitally signed by SANJAY
Sl No DSR No Description of Item Location Unit Quantity DSR rate Amount(Rs) Market Rate Amount(Rs)
Sub-Head : Rain Water Harvesting works
SITC of Rainwater Harvesting System as per Below mentioned procedure : Pit
excavation of 4x2x2 including boring of 300 dia of desired depth using UPVC
CM/RMS pipe 150 mm dia with MS/PVC Bail Plug and MS/PVC End Cap, including
preparation of base structure, Splitting of Stone Aggregate 20mm nominal Size/
Boulders 150mm, Jamuna sand layer 100 mm thick, including Installation/laying of
Non-Woven Geotextiles 400 GSM in Double layer, Installation of Modular cross
waves layer (Recycled Polypropylene made) Laying of Spacers on top Layer for
making monolithic/interlocking structure, Wrapping & Welding of Non-Woven
Geotextiles, Providing and laying Jamuna sand layer 50mm thick on top of
Geotextile, Refilling of Earth Excavation of Earth for Filter & Filter` Chamber up to
required depth Providing and laying CC 1: 5: 10 & 1: 2: 4 as base for fixing of pure
rain filters Installation of pure rain filters FRP Based, Construction of brick masonry silt
chamber Interconnection of UPVC Pipe with storm water drain and silt chamber,
filter, cross wave structure, testing of
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT Tech interior.pdf
Tender Document
BoQ.pdf
Tender Document
Forms.pdf
Tender Document
SCC.pdf
Tender Document
GCC upto amend4.pdf
Tender Document
Instruction to Bidder for online Bid Submission.pdf
Tender Document
INTEGRITY PACT SIDBI PANCHKULA_001.pdf
Tender Document
Approved make list.pdf
Tender Document
Layout.pdf
Tender Document
corrigendum-1813-Corrigendum-III.pdf
pdf • 0.56 MB
corrigendum-1812-Corrigendum-II.pdf
pdf • 0.56 MB
corrigendum-1757-587 Corrigendum-I.pdf
pdf • 0.16 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .