Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 LAccepted-AOC MAIN SHEETLA MATA ROAD GURGAON SHOP NO 5 MAIN SHEETLA MATA ROAD NEAR FEDEX COURIER GURGAON 122001 | GURGAON | GURUGRAM | HARYANA | 122001 | L1 | Accepted-AOC L1 |
Tender Value
₹2.1 L
EMD Value
₹4,200
Closing Date
17 Feb 2020, 5:00 pmClosed
Raja Nagender Singh
XEN(E) Gurugram
Special repair renovation of high dependency unit in existing B.K. hospital at Faridabad. (pdg. internal E.I. only)
2020_HRY_117830_1
Special repair renovation of high dependency unit
Open Tender
Electrical Works
Works
60 days
XEN(E) Gurugram
Refer DNIT
2 documents required · 2 mandatory
₹1,000
Executive Engineer,Electrical Division
₹4,200
3 May 2020
11 Feb 2020
18 Feb 2020
11 Feb 2020
17 Feb 2020
11 Feb 2020
Amount
Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suiteble size of rag bolts with cement concrete ,duly painted with three coats of approved paint including one coat of red oxide. Size 40 mm x 40 mm x 6 mm.
Supply and erection of 3 mm thick mild steel sheet duly welded on existing M.S. angle iron frame for fixing the main switches etc. as required, duly painted with three coats of approved paint including one coat of red oxide.
Suply and erection of sheet steel enclosure 2 pole / 3 pole with earth plug and socket suitable for incorporating single pole / triple pole MCB on wall / on existing pedestal complete with necessary connections etc. S.P.N. enclosure for single pole MCB 20 amp.
Supply and erection of miniature circuit breaker/ isolator 240/415 V in the existing distribution board including making necessary connection.Miniature circuit breakers of 9 KA breaking capacity.SP MCB of 9 KA breaking capacity 6 amp. to 32 amp.
Erection only of 1x40 watts or 2x40 watts 1220 mm long /1x20 watts or 2x20 watts ,610 mm long fluorescent tube fitting directly on wall including necessary connections with 0.75 sqmm ( 24 / 0.20 mm ) PVC copper flexible cable for connecting the tube with the adjecent point.
Erection of ceiling fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to the site of work.
Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. Heavy gauge welded conduit pipe 20 mm dia 1.60 mm thickness on surface.
Heavy gauge welded conduit pipe 25 mm dia 1.60 mm thickness on surface.
Supply and erection of under ground cable, loose in existing pipe or trenches complete with necessary connections . 50 Sq. mm 3.5 Core Ard. Cable .
Supply and erection of suitable compression type brass cable glands for underground Cable. 25 Sqmm to 50 Sqmm Cable 2 to 4 Core.
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe.Cable size 1.5 sq.mm(3/ 0.81 mm)
Cable size 2.5 sq.mm(3/ 1.05 mm)
Cable size 4.0 sq.mm(7/ 0.85 mm)
Cable size 6.0 sq.mm(7/ 1.05 mm)
Supply & erection of PVC conduit pipe ISI marked(Medium) recessed in wall/ ceiling etc. including cost of PVC bends, inspection boxe and all other material required to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of work.25 mm dia
Suply and erection of moulded case circuit breaker single pole/ 4 pole on wall/ on existing pedestal including bounding to earth and making necessary connection equired to complete the job the job in all respect up to the entire satisfaction of the Engineer -in - Charge of the work.4 pole MCCB 100 amp.
4 pole MCCB 300 amp to 400 amp.
Wiring for light point/ fan point/ exhaust fan point/ call bell point and 5 amp. plug point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed MS conduit with modular switch and socket, modular inner and outer plate, suitable GI box etc. with all labour, material, chasing, refelling of walls complete in all respect upto entire satisfaction of Engineer in Charge .Light Point/Exhaust fan PointShort Point
Medium Point .
Long Point .
Fan Point Point Medium Point .
Long Point .
3 pin 5 amp. plug point including earthing the 3rd. pin etc.Short point.
3 pin 15 amp. plug point with 4 sq mm PVC insulated copper conductor cable including earthing the 3rd. pin etc. Long point
Supply and erection of Double door sheet steel superline/ Powerline Vertical distribution boards suitable for TP/ FP veritcal MCCBs upto 125 amp as incomer (but without cost of MCCB) complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. (load line)12 way load line
Supply and erection of 1 no. 16 way moduler box made of G.I. sheet with inner & outer plate including cost and fixing of 3 nos. sockets and 3 nos. switches of 10 amp and 1 no. multi socket and switch of 16/20 amp, M.S. box duly recessed in wall, cost of necessary cement and sand mixture making necessary connection complete in all respect upto the entire satisfaction of Engineer-in-charge of work. (for computer point )
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .